Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Lasers Surg Med ; 53(5): 713-721, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33169857

RESUMO

BACKGROUND AND OBJECTIVES: In photothermal therapy, cancerous tissue is treated by the heat generated from absorbed light energy. For effective photothermal therapy, the parameters affecting the induced temperature should be determined before the treatment by modeling the increase in temperature via numerical simulations. However, accurate simulations can only be achieved when utilizing the accurate optical, thermal, and physiological properties of the treated tissue. Here, we propose a multi-wavelength photo-magnetic imaging (PMI) technique that provides quantitative and spatially resolved tissue optical absorption maps at any wavelength within the near-infrared (NIR) window to assist accurate photothermal therapy planning. STUDY DESIGN/MATERIALS AND METHODS: The study was conducted using our recently developed multi-wavelength PMI system, which operates at four laser wavelengths (760, 808, 860, and 980 nm). An agar tissue-simulating phantom containing water, lipid, and ink was illuminated using these wavelengths, and the slight internal laser-induced temperature rise was measured using magnetic resonance thermometry (MRT). The phantom optical absorption was recovered at the used wavelengths using our dedicated PMI image reconstruction algorithm. These absorption maps were then used to resolve the concentration of the tissue chromophores, and thus deduce its optical absorption spectrum in the NIR region based on the Beer-Lambert law. RESULTS: The optical absorption of the phantom was successfully recovered at the used four wavelengths with an average error of ~1.9%. The recovered absorption coefficient was then used to simulate temperature variations inside the phantom. A comparison between the modeled temperature maps and the MRT measured ones showed that these maps are in a good agreement with an average pseudo R2 statistic of 0.992. These absorption values were used to successfully recover the concentration of the used chromophores. Finally, these concentrations are used to accurately calculate the total absorption spectrum of the phantom in the NIR spectral window with an average error as low as ~2.3%. CONCLUSIONS: Multi-wavelength PMI demonstrated a great ability to assess the distribution of tissue chromophores, thus providing its total absorption at any wavelength within the NIR spectral range. Therefore, applications of photothermal therapy applied at NIR wavelengths can benefit from the absorption spectrum recovered by PMI to determine important parameters such as laser power as well as the laser exposure time needed to attain a specific increase in temperature prior to treatment. Lasers Surg. Med. 00:00-00, 2020. © 2020 Wiley Periodicals LLC.


Assuntos
Terapia Fototérmica , Termometria , Temperatura Alta , Lasers , Imagens de Fantasmas
2.
Biomed Opt Express ; 11(8): 4244-4254, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32923039

RESUMO

Photo-magnetic imaging (PMI) is an emerging optical imaging modality that showed great performance on providing absorption maps with high resolution and quantitative accuracy. As a multi-modality technology, PMI warms up the imaged object using a near infrared laser while temperature variation is measured using magnetic resonance imaging. By probing tissue at multiple wavelengths, concentration of the main tissue chromophores such as oxy- and deoxy-hemoglobin, lipid, and water are obtained then used to derive functional parameters such as total hemoglobin concentration and relative oxygen saturation. In this paper, we present a multi-wavelength PMI system that was custom-built to host five different laser wavelengths. After recovering the high-resolution absorption maps, a least-squared minimization process was used to resolve the different chromophore concentration. The performance of the system was experimentally tested on a phantom with two different dyes. Their concentrations were successfully assessed with high spatial resolution and average accuracy of nearly 80%.

4.
Phys Med Biol ; 59(17): N163-9, 2014 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-25138915

RESUMO

The combined use of a torso-pelvic RF array coil and endorectal RF coil is the current state-of-the-art in prostate MRI. The endorectal coil provides high detection sensitivity to acquire high-spatial resolution images and spectroscopic data, while the torso-pelvic coil provides large coverage to assess pelvic lymph nodes and pelvic bones for metastatic disease. However, the use of an endorectal coil is an invasive procedure that presents difficulties for both patients and technicians. In this study, we propose a novel non-invasive RF coil design that can provide both image signal to noise ratio and field of view coverage comparable to the combined torso-pelvic and endorectal coil configuration. A prototype coil was constructed and tested using a pelvic phantom. The results demonstrate that this new design is a viable alternative for prostate MRI.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Neoplasias da Próstata/patologia , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Metástase Neoplásica , Imagens de Fantasmas , Ondas de Rádio , Sensibilidade e Especificidade
5.
Proc SPIE Int Soc Opt Eng ; 89372014 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-25767691

RESUMO

Multi-modality imaging leverages the competitive advantage of different imaging systems to improve the overall resolution and quantitative accuracy. Our new technique, Photo-Magnetic Imaging (PMI) is one of these true multi-modality imaging approaches, which can provide quantitative optical absorption map at MRI spatial resolution. PMI uses laser light to illuminate tissue and elevate its temperature while utilizing MR thermometry to measure the laser-induced temperature variation with high spatial resolution. The high-resolution temperature maps are later converted to tissue absorption maps by a finite element based inverse solver that is based on modeling of photon migration and heat diffusion in tissue. Previously, we have demonstrated the feasibility of PMI with phantom studies. Recently, we have managed to reduce the laser power under ANSI limit for maximum skin exposure therefore, we have well positioned PMI for in vivo imaging. Currently we are expanding our system by adding multi-wavelength imaging capability. This will allow us not only to resolve spatial distribution of tissue chromophores but also exogenous contrast agents. Although we test PMIs feasibility with animal studies, our future goal is to use PMI for breast cancer imaging due to its high translational potential.

6.
Phys Med Biol ; 56(21): 6809-22, 2011 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-21971137

RESUMO

Despite its high sensitivity, the variable specificity of magnetic resonance imaging (MRI) in breast cancer diagnosis can lead to unnecessary biopsies and over-treatment. Scintimammography (SMM) could potentially supplement MRI to improve the diagnostic specificity. The synergistic combination of MRI and SMM (MRSMM) could result in both high sensitivity from MRI and high specificity from SMM. Development of such a dual-modality system requires the integration of a radio frequency (RF) coil and radiation detector in a strong magnetic field without significant mutual interference. In this study, we developed and tested a unilateral breast array coil specialized for MRSMM imaging. The electromagnetic field, specific absorption ratio and RF coil parameters with cadmium-zinc-telluride detectors encapsulated in specialized RF and gamma-ray shielding mounted within the RF coil were investigated through simulation and experimental measurements. Simultaneous MR and SMM images of a breast phantom were also acquired using the integrated MRSMM system. This work, we feel, represents an important step toward the fabrication of a working MRSMM system.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Imageamento por Ressonância Magnética/instrumentação , Mamografia/instrumentação , Neoplasias da Mama/diagnóstico por imagem , Cádmio , Cobre/química , Campos Eletromagnéticos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Imagens de Fantasmas , Telúrio , Zinco
7.
Phys Med Biol ; 56(4): N63-9, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21258141

RESUMO

In this study, we investigated the in vivo application of an integrated small-animal magnetic resonance (MR) and gamma-ray imaging system that consists of a semiconductor-based radiation detector, a parallel-hole collimator, and a specialized radiofrequency coil. Gadodiamide and (99m)Tc sestimibi agents were injected simultaneously into a mouse, and simultaneous dynamic contrast-enhanced MR and scintigraphic images of the kidneys were acquired. The time curves of both the MR signal intensity and radioactivity indicate a rapid uptake of the agents followed by a more gradual excretion, consistent with the previously reported literature. Our results demonstrate the feasibility of measuring multiple biological processes at the same time using both MR contrast agents and radiotracers.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Cintilografia/métodos , Animais , Feminino , Rim/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos BALB C , Tecnécio Tc 99m Sestamibi
8.
Phys Med Biol ; 55(9): 2589-600, 2010 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-20393229

RESUMO

MR imaging of nuclei other than hydrogen has been used to investigate metabolism in humans and animals. However, MRI observable nuclei other than hydrogen are not as abundant and as a result the image SNR is lower. Dual-tuned radio frequency (RF) coils are developed for these studies in which high-resolution structural images are acquired using hydrogen and metabolic information is acquired by exciting the other nucleus. Using a dual-tuned coil, the experimenter avoids the inconvenience of moving the patient out and replacing the RF coil for imaging different nuclei. This also eliminates image registration problems. However, the common scheme of using trap circuits for dual-tuned operation results in increased coil losses as well as problems in obtaining optimal tuning and matching at both frequencies. Here, a new approach is presented using PIN diodes to switch the coil between two resonance frequencies. This design eliminates the need for the trap circuit and associated losses from the self-resistance of the trap circuit inductors. At the operating frequencies we used, the equivalent series resistance of an inductor is higher than that of the PIN diodes. In order to test the efficacy of this new approach, we first built two surface coils of identical geometry, one with the conventional trap circuits and one with the PIN diode switches. We also studied the performances of both coils when the coils are divided into shorter conductors segments by adding more tuning elements. It is known that dividing the coil into shorter conductor segments helps reduce radiation and electric field losses. We explored this effect for both coils at both operating frequencies. Finally, a dual-tuned receive-only phased array was designed and built with the PIN diode circuit to switch between two resonance frequencies. A conventional dual-tuned birdcage coil was designed and built to transmit RF power. A unique feature of this coil is that the RF power is fed through two separate sets of four ports for more uniform 1H and 23Na excitation. We demonstrated that the performance is significantly improved at both frequencies with the PIN diode switched dual-frequency operation compared to an identical coil with a trap circuit.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Eletrodos , Imagens de Fantasmas
9.
Phys Med Biol ; 55(9): 2495-504, 2010 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-20371909

RESUMO

Magnetic resonance (MR)-based multimodality imaging systems, such as single-photon emission tomography (SPECT)/magnetic resonance imaging (MRI) or positron emission tomography (PET)/MRI, face many difficulties because of problems with the compatibility of the nuclear detector system with the MR system. However, several studies have reported on the design considerations of MR-compatible nuclear detectors for combined SPECT/MRI. In this study, we developed a new radiofrequency (RF) coil and gamma-ray radiation shielding assembly to advance the practical implementation of SPECT/MRI in providing high sensitivity while minimizing the interference between the MRI and SPECT systems. The proposed assembly consists of a three-channel receive-only RF coil and gamma-ray radiation shields made of a specialized lead composite powder designed to reduce conductivity and thus minimizing any effect on the magnetic field arising from the induced eddy currents. A conventional birdcage RF coil was also tested for comparison with the proposed RF coil. Quality (Q)-factors were measured using both RF coils without any shielding, with solid lead shielding, and with our composite lead shielding. Signal-to-noise ratios (SNRs) were calculated using 4 T MR images of phantoms both with and without the new gamma-ray radiation shields. The Q-factor and SNR measurements demonstrate the improved MRI performance due to the new RF coil/gamma-ray radiation shield assembly designed for SPECT/MRI, making it a useful addition to multimodality imaging technology not only for animal studies but also for in vivo study of humans.


Assuntos
Raios gama , Imageamento por Ressonância Magnética/instrumentação , Proteção Radiológica/instrumentação , Ondas de Rádio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Animais , Aumento da Imagem , Imagens de Fantasmas
10.
Phys Med Biol ; 55(6): 1563-75, 2010 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-20164533

RESUMO

In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B(0) field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem Corporal Total/métodos , Compostos de Cádmio/química , Campos Eletromagnéticos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Telúrio/química , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Imagem Corporal Total/instrumentação , Zinco/química
11.
Technol Cancer Res Treat ; 9(1): 21-8, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20082527

RESUMO

Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem Corporal Total/métodos , Animais , Compostos de Cádmio/química , Camundongos , Camundongos Nus , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Telúrio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA