Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Psychiatry ; 50: 34-39, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29398565

RESUMO

Postoperative cognitive impairment is among the most common medical complications associated with surgical interventions - particularly in elderly patients. In our aging society, it is an urgent medical need to determine preoperative individual risk prediction to allow more accurate cost-benefit decisions prior to elective surgeries. So far, risk prediction is mainly based on clinical parameters. However, these parameters only give a rough estimate of the individual risk. At present, there are no molecular or neuroimaging biomarkers available to improve risk prediction and little is known about the etiology and pathophysiology of this clinical condition. In this short review, we summarize the current state of knowledge and briefly present the recently started BioCog project (Biomarker Development for Postoperative Cognitive Impairment in the Elderly), which is funded by the European Union. It is the goal of this research and development (R&D) project, which involves academic and industry partners throughout Europe, to deliver a multivariate algorithm based on clinical assessments as well as molecular and neuroimaging biomarkers to overcome the currently unsatisfying situation.


Assuntos
Disfunção Cognitiva/etiologia , Neuroimagem , Complicações Pós-Operatórias/diagnóstico , Biomarcadores , Disfunção Cognitiva/diagnóstico , Europa (Continente) , União Europeia , Humanos , Medição de Risco , Fatores de Risco
2.
Eur J Anaesthesiol ; 24(11): 920-6, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17588273

RESUMO

BACKGROUND AND OBJECTIVES: Target-controlled infusion, via the calculated effect compartment concentrations, may help anaesthesiologists to titrate anaesthetic depth and to shorten recovery from anaesthesia. METHODS: In this prospective, randomized clinical study, we compared the performance of six inexperienced anaesthesiologists with <1 yr of training when using target- or manually controlled infusion of propofol, combined with manual dosing of fentanyl. Ninety-two premedicated ASA I-III patients undergoing minor elective urological or gynaecological surgery were assigned to the manual- or target-controlled infusion group. Bispectral index was recorded in a blinded manner. Subjective assessment of anaesthetic depth on a 10 point numerical scale (1 = very deep anaesthesia, 10 = awake) was asked at regular intervals and the correlation with the blinded bispectral index was analysed using the prediction probability, PK. The propofol concentration profile was calculated post hoc. RESULTS: Propofol administration was similar in both groups with no significant difference for the administered amount and concentrations of propofol. Recovery times were also not different. In both groups, a large percentage of the bispectral index data points recorded during surgery showed bispectral index values below the recommended value of 40, but in the target-controlled infusion group there were significantly less bispectral index values above the recommended upper limit of 60 (2.5% vs. 5.1%). CONCLUSIONS: A target-controlled infusion system does not help inexperienced anaesthesiologists to assess anaesthetic depth or to shorten recovery times, but may reduce episodes of overly light anaesthesia and thus help to prevent awareness.


Assuntos
Anestesia Intravenosa , Anestésicos Intravenosos/administração & dosagem , Eletroencefalografia/efeitos dos fármacos , Propofol/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestésicos Inalatórios , Conscientização/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Estado de Consciência/efeitos dos fármacos , Feminino , Fentanila/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Humanos , Infusões Intravenosas , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Óxido Nitroso
3.
World J Urol ; 25(2): 185-91, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17171563

RESUMO

Fast-track surgery describes innovative treatment concepts ensuring a faster convalescence phase. The aim of this study was to allow hospital discharge 3 days after surgery without additional complications in patients receiving LRPE for localized prostate cancer. Twenty-five patients each were randomized in the study groups to verify if a fast-track regimen could be transferred into clinical routine. The perioperative data, early complications, hospital stay as well as readmission rate were analyzed. The mean postoperative stay was 3.6 days in the fast-track group versus 6.7 days in the conventional group. The overall complications were significantly less in the fast-track procedure. The readmission rate was low and not significant. Patients receiving an LRPE benefit from a suitable fast-track concept. The postoperative hospital stay could be shortened nearly by half with a significantly decreased overall complication rate. Thus, fast-track concepts might contribute to saving resources in the long term. However, more evidence based on larger prospective trials is needed to achieve optimal quality of life for patients perioperatively.


Assuntos
Laparoscopia , Tempo de Internação , Assistência Perioperatória/métodos , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Idoso , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
4.
Eur J Anaesthesiol ; 23(11): 931-6, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16824245

RESUMO

BACKGROUND AND OBJECTIVE: Derived parameters of the electroencephalogram and auditory evoked potentials can be used to determine depth of anaesthesia and sedation. However, it is not known whether any parameter can identify the occurrence of awareness in individual patients. We have compared the performance of bispectral index and a new composite index derived from auditory evoked potentials and the electroencephalogram (AAI 1.61) in predicting consciousness, explicit and implicit memory during moderate sedation with propofol. METHODS: Twenty-one patients with spinal anaesthesia received intraoperatively propofol at the age-corrected C(50) for loss of consciousness and were presented test words via headphones. Bispectral index and AAI 1.61 (auditory evoked potentials, AEP-Monitor2) were recorded in parallel as well as the Observer's Assessment of Alertness/Sedation-score. Postoperatively, testing for explicit and implicit memory formation was performed. RESULTS: Bispectral index and AAI 1.61 correlated well with loss of consciousness defined by an Observer's Assessment of Alertness/Sedation-score of 2 (identical P(K) of 0.87), but did not allow a prediction of postoperative explicit or implicit recall. CONCLUSIONS: Both bispectral index and AAI may be indices of depth of sedation rather than indicators of memory formation, which persists during propofol sedation even after loss of consciousness.


Assuntos
Anestésicos Intravenosos , Sedação Consciente , Eletroencefalografia , Potenciais Evocados Auditivos , Monitorização Intraoperatória/instrumentação , Propofol , Estimulação Acústica , Adulto , Idoso , Anestesia Intravenosa , Conscientização , Estado de Consciência , Feminino , Humanos , Masculino , Memória/efeitos dos fármacos , Pessoa de Meia-Idade
5.
Eur J Anaesthesiol ; 23(4): 292-9, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16438755

RESUMO

BACKGROUND AND OBJECTIVE: To measure 'depth of anaesthesia', anaesthesiologists use a combination of observable end-points such as immobility and autonomic stability. Unconsciousness and amnesia are not reliably observable end-points, but correlate with parameters derived from the electroencephalogram. We investigated the association of subjective assessment and electroencephalographic measures of anaesthetic depth in a group of experienced (>4 yr of experience) and a group of inexperienced (<2 yr of experience) anaesthesiologists. METHODS: One hundred ASA I or II patients were assigned to either group. Anaesthesiologists assessed 'anaesthetic depth' using an 11-point numeric and a 5-point verbal scale. Bispectral index and spectral entropy were recorded as electroencephalogram parameters. The association between the subjective assessment and the electroencephalogram parameters was calculated using the prediction probability, PK. RESULTS: Association between subjective assessment and electroencephalographic parameters showed a tendency to a better prediction probability in the experienced group. The difference was significant (P < 0.05) for the bispectral index (PK 0.76 +/- 0.01 for experienced and 0.71 +/- 0.01 for inexperienced anaesthesiologists). In both groups, a large percentage of the data points recorded during surgery showed bispectral index values above the recommended value of 60 (13.2% in the experienced and 34.3% in the inexperienced group) despite a subjective assessment of 'deep' or 'very deep' anaesthetic depth. CONCLUSION: The study demonstrates that the association between subjectively assigned values of anaesthetic depth and electroencephalographic parameters of anaesthetic depth is better for anaesthesiologists with more clinical experience. However, in the 'inexperienced' as well as 'experienced' group a high percentage of bispectral index and entropy values above 60 occurred despite a subjective assessment of adequate anaesthetic depth. Although there was no evidence for explicit memory, this may indicate a risk for memory formation.


Assuntos
Anestesia/métodos , Anestesiologia/métodos , Médicos , Adulto , Humanos , Acontecimentos que Mudam a Vida , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Acta Anaesthesiol Scand ; 50(2): 193-200, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16430541

RESUMO

BACKGROUND: The spinal cord is an important site of anaesthetic action because it mediates surgical immobility. During anaesthesia with volatile anaesthetics, it has been shown that the suppression of the spinal H-reflex correlates with surgical immobility. To evaluate whether the H-reflex could also be a possible candidate for monitoring immobility during propofol anaesthesia, this study assessed the concentration-dependent suppression of the H-reflex by propofol. To discriminate different effect sites, the individual concentration response-curves and the t(1/2ke0) of the H-reflex have been compared with those of two EEG parameters. METHODS: In 18 patients, anaesthesia was induced and maintained with propofol infused using a target-controlled infusion pump at stepwise increasing and decreasing plasma concentrations between 0.5 and 4.5 mg/l. The H-reflex of the soleus muscle was recorded at a frequency of 0.1 Hz. Calculated propofol concentrations and H-reflex amplitude were analysed in terms of a pharmacokinetic-pharmacodynamic (PKPD) model with a sigmoid concentration-response function. RESULTS: For slowly increasing propofol concentrations, computer fits of the PKPD model for H-reflex suppression by propofol yielded the following median parameters: EC50 1.1 (0.8-1.7) mg/l, slope parameter 2.4 (2.0-3.7), and a t(1/2ke0) of 6.7 (2.8-7.5, 25-75% quantiles) min. For the bispectral index, the t(1/2ke0) was 2.2 (1.8-3.1) min and for the spectral edge frequency at the 95th percentile of the power spectrum 2.8 (1.9-3.2) min. CONCLUSIONS: Propofol, unlike sevoflurane, suppresses the spinal H-reflex at concentrations far lower than the C50 skin incision. The differences in t(1/2ke0)-values indicate the presence of different effect compartments for effects on the H-reflex and the EEG.


Assuntos
Anestésicos Intravenosos/farmacologia , Reflexo H/efeitos dos fármacos , Propofol/farmacologia , Medula Espinal/efeitos dos fármacos , Análise de Variância , Anestésicos Intravenosos/sangue , Anestésicos Intravenosos/farmacocinética , Relação Dose-Resposta a Droga , Estimulação Elétrica/métodos , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Propofol/sangue , Propofol/farmacocinética , Fatores de Tempo
7.
Br J Anaesth ; 96(1): 118-26, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16317030

RESUMO

BACKGROUND: The immobilizing effects of volatile anaesthetics are primarily mediated at the spinal level. A suppression of recurrent spinal responses (F-waves), which reflect spinal excitability, has been shown for propofol. We have assessed the concentration-dependent F-wave suppression by propofol and related it to the logistic regression curve for suppression of movement to noxious stimuli and the effect on the bispectral index (BIS). The predictive power of drug effects on F-waves and BIS for movement responses to noxious stimuli was tested. METHODS: In 24 patients anaesthesia was induced and maintained with propofol infused by a target controlled infusion pump at stepwise increasing and decreasing plasma concentrations between 0.5 and 4.5 mg litre(-1). The F-waves of the abductor hallucis muscle were recorded at a frequency of 0.2 Hz. BIS values were recorded continuously. Calculated propofol concentrations and F-wave amplitude and persistence were analyzed in terms of a pharmacokinetic-pharmacodynamic (PK/PD) model with a simple sigmoid concentration-response function. Motor responses to tetanic electrical stimulation (50 Hz, 60 mA, 5 s, volar forearm) were tested and the EC(50tetanus) was calculated using logistic regression. RESULTS: For slowly increasing propofol concentrations, computer fits of the PK/PD model for the suppression by propofol yielded a median EC50 of 1.26 (0.4-2.3) and 1.9 (1.0-2.8) mg litre(-1) for the F-wave amplitude and persistence, respectively. These values are far lower than the calculated EC(50) for noxious electrical stimulation of 3.75 mg litre(-1). This difference results in a poor prediction probability of movement to noxious stimuli of 0.59 for the F-wave amplitude. CONCLUSIONS: F-waves are almost completely suppressed at subclinical propofol concentrations and they are therefore not suitable for prediction of motor responses to noxious stimuli under propofol mono-anaesthesia.


Assuntos
Anestésicos Intravenosos/farmacologia , Monitorização Intraoperatória/métodos , Movimento/efeitos dos fármacos , Propofol/farmacologia , Medula Espinal/efeitos dos fármacos , Adulto , Anestésicos Intravenosos/sangue , Relação Dose-Resposta a Droga , Estimulação Elétrica , Eletroencefalografia/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurônios Motores/efeitos dos fármacos , Neurônios Motores/fisiologia , Dor/fisiopatologia , Propofol/sangue , Medula Espinal/fisiopatologia
8.
Br J Anaesth ; 95(6): 789-97, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16199415

RESUMO

BACKGROUND: Decreased spinal excitability contributes to the immobilizing effects of halogenated ethers during general anaesthesia. Recurrent spinal responses such as F-waves reflect spinal excitability and are suppressed by volatile anaesthetics. To evaluate whether F-waves are suitable for monitoring immobility, the concentration-dependent effects of sevoflurane on F-waves were compared with effects on the Bispectral Index (BIS). The predictive power of all parameters for movement responses to noxious stimuli was tested. In addition, the effect of the noxious stimulus itself on F-waves was investigated. METHODS: In 28 patients, F-waves were recorded during sevoflurane anaesthesia at a frequency of 0.2 Hz at the lower limb. To insert a laryngeal mask, the sevoflurane concentration was initially increased to approximately 4%, which caused a complete extinction of F-waves. The sevoflurane concentration was then reduced until the F-waves recovered. BIS and spectral edge frequency (SEF(95)) were recorded continuously. The t(1/2ke0) and EC(50) values of the F-wave persistence and amplitude were calculated using a standard pharmacokinetic-pharmacodynamic model. During decreasing sevoflurane concentration motor responses to tetanic electrical stimulation (50 Hz, 60 mA, 5 s, volar forearm) were tested in seven patients and MAC(tetanus) was calculated using logistic regression. RESULTS: Sevoflurane reduces the F-wave amplitude with an EC(50) of 0.79 vol% at a far lower concentration than the calculated MAC(tetanus) (1.5 vol%), whereas the F-wave persistence yields an EC(50) of 1.4 vol%. Spinal and EEG parameters predicted the motor responses to movement better than chance alone, but did not differ significantly from each other. CONCLUSION: F-waves, especially the F-wave amplitude, cannot be used to predict movement to noxious stimuli during sevoflurane anaesthesia because they are almost completely suppressed at subclinical sevoflurane concentrations. Either the particular motoneurone pool (the largest motoneurones) assessed by F-waves is not involved in generating movement to painful stimuli or direct effects on motoneurone excitability are not involved in the suppression of movement to painful stimuli by sevoflurane.


Assuntos
Anestésicos Inalatórios/farmacologia , Éteres Metílicos/farmacologia , Monitorização Intraoperatória/métodos , Movimento/efeitos dos fármacos , Medula Espinal/efeitos dos fármacos , Adulto , Anestésicos Inalatórios/administração & dosagem , Relação Dose-Resposta a Droga , Estimulação Elétrica/métodos , Eletroencefalografia/efeitos dos fármacos , Eletromiografia/métodos , Feminino , Humanos , Éteres Metílicos/administração & dosagem , Pessoa de Meia-Idade , Neurônios Motores/efeitos dos fármacos , Neurônios Motores/fisiologia , Reflexo/efeitos dos fármacos , Sevoflurano , Medula Espinal/fisiopatologia
9.
Histopathology ; 44(2): 116-28, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14764055

RESUMO

AIMS: Umbilical blood vessels are not innervated and regulation of blood flow to the placenta must depend on structural changes and the effect of vasoactive factors. Failure to achieve these adaptations may result in reduced fetoplacental perfusion. The purpose of this study was to determine whether neuronal nitric oxide synthase (nNOS) is expressed in human vascular smooth muscle cells (VSMCs) of the fetoplacental circulation. nNOS has been described as a non-endothelial NOS counterregulating vasoconstriction only in the VSMCs of animal models. Therefore, we investigated nNOS expression in the fetoplacental unit from preeclamptic and healthy pregnancies. METHODS AND RESULTS: We investigated nNOS regulation by immunohistochemistry, Western blotting and reverse transcriptase-polymerase chain reaction analysis. nNOS activity was determined by measuring the conversion of L-3H-arginine to L-3H-citrulline. nNOS expression was revealed only in VSMCs of the human umbilical veins, but not in umbilical arteries. A more direct assessment of nNOS activity showed that a small, but consistent amount of nNOS is present in the denuded media of the umbilical vein. In VSMCs of the umbilical veins during preeclampsia a total loss of nNOS protein expression and a significant decrease in mRNA expression were seen. CONCLUSIONS: Loss of nNOS expression is associated with preeclampsia. It may alter the regulation of blood flow in the fetal and maternal placental vasculature in preeclampsia. However, the impact of NO produced by nNOS on the vascular tone of umbilical veins remains to be elucidated.


Assuntos
Miócitos de Músculo Liso/enzimologia , Óxido Nítrico Sintase/biossíntese , Pré-Eclâmpsia/fisiopatologia , Artérias Umbilicais/enzimologia , Veias Umbilicais/enzimologia , Adulto , Western Blotting , Primers do DNA , Eletroforese em Gel de Poliacrilamida , Feminino , Humanos , Imuno-Histoquímica , Óxido Nítrico Sintase Tipo I , Gravidez , RNA Mensageiro/análise , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Cordão Umbilical/citologia , Cordão Umbilical/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...