1.
Analyst ; 149(3): 700-706, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38054815

RESUMO

Multimodal imaging and spectroscopy like concurrent scanning transmission X-ray microscopy (STXM) and X-ray fluorescence (XRF) are highly desirable as they allow retrieving complementary information. This paper reports on the design, development, integration and field testing of a novel in situ atomic force microscopy (AFM) instrument for operation under high vacuum in a synchrotron soft X-ray microscopy STXM-XRF end-station. A combination of µXRF and AFM is demonstrated for the first time in the soft X-ray regime, with an outlook for the full XRF-STXM-AFM combination.

2.
J Phys Condens Matter ; 33(36)2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34253693

RESUMO

Specular and off-specular neutron reflectometry have been used in a combined approach to study thin polymer films. Our goal in this work is to illustrate the power of the off-specular scattering technique to probe the properties of the buried interface of immiscible polymer bilayers of deuterated polystyrene and protonated poly(methyl methacrylate) (h-PMMA). The diffuse scattering stemming from these systems is discussed in relation to thermal fluctuations at the polymer/polymer interface, providing a means to extract in-plane correlation lengths from buried interfaces. In addition the onset of hole formation in the top layer is evidenced by the diffuse scattering, not easily detectable by specular reflection alone.

3.
Opt Lett ; 41(1): 29-32, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26696150

RESUMO

The feasibility of an off-axis x-ray reflection zone plate to perform wavelength-dispersive spectroscopy, on-axis point focusing, and two-dimensional imaging is demonstrated by means of one and the same diffractive optical element (DOE) at a synchrotron radiation facility. The resolving power varies between 3×101 and 4×102 in the range of 7.6 keV to 9.0 keV, with its maximum at the design energy of 8.3 keV. This result is verified using an adjustable entrance slit, by which horizontal (H) and vertical (V) focusing to 0.85 µm(H) and 1.29 µm(V) is obtained near the sagittal focal plane of the astigmatic configuration. An angular and axial scan proves an accessible field of view of at least 0.6 arcmin × 0.8 arcmin and a focal depth of ±0.86 mm. Supported by the grating efficiency of around 17.5% and a very short pulse elongation, future precision x-ray fluorescence and absorption studies of transition metals at their K-edge on an ultrashort timescale could benefit from our findings.

4.
Opt Express ; 23(23): 29476-83, 2015 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-26698431

RESUMO

We have developed an electron beam excitation ultra-soft X-ray add-on device for a scanning electron microscope with a reflective zone plate mulichannel spectrometer in order to analyse ultra-light elements such as Li and B. This spectrometer has high (λ/Δλ~100) resolving power in the energy range of 45 eV - 1120 eV. Metallic Li samples were examined and fluorescence spectra successfully measured. Energy resolution of 0.49 eV was measured in the ultra-low energy range using the Al L(2,3) line at 71 eV. High sensitivity of Boron detection was demonstrated on a B(4)C sample with layer thicknesses of 1-50 nm, detecting an amount of metallic Boron as small as ~0.57 fg.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...