Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 80(1): 16-25, 2024 Jan 20.
Artigo em Japonês | MEDLINE | ID: mdl-37940546

RESUMO

PURPOSE: The purpose of this study was to optimize radiopharmaceutical dosage in single-photon emission computed tomography (SPECT) nuclear medicine. Therefore, we examined a variable dose (VD) method using body weight as an index in resting myocardial scintigraphy using a 99mTechnetium (99mTc) preparation. METHODS: In this study, we compared the VD method with the fixed dose (FD) method without a variable by body weight. There were 50 patients using the VD method and 50 patients using the FD method. For the VD method, we set the target average count (counts/pixel) per SPECT view. Using the myocardial average count of the FD method, and the estimated intracorporeal radioactivity at the start of the examination, the dose of the VD method, which varies appropriately depending on the body weight, was calculated. RESULTS: The VD method had less variation in myocardial counting and was closer to the target count than the FD method, and the median dosage decreased. CONCLUSION: The VD method suggested the possibility of obtaining a count independent of physique and stable image quality, reducing medical and occupational radiation exposure in resting myocardial blood flow scintigraphy.


Assuntos
Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Cintilografia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Peso Corporal , Tecnécio
2.
Diagnostics (Basel) ; 13(18)2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37761370

RESUMO

Although interventional radiology (IVR) is preferred over surgical procedures because it is less invasive, it results in increased radiation exposure due to long fluoroscopy times and the need for frequent imaging. Nurses engaged in cardiac IVR receive the highest lens radiation doses among medical workers, after physicians. Hence, it is important to measure the lens exposure of IVR nurses accurately. Very few studies have evaluated IVR nurse lens doses using direct dosimeters. This study was conducted using direct eye dosimeters to determine the occupational eye dose of nurses engaged in cardiac IVR, and to identify simple and accurate methods to evaluate the lens dose received by nurses. Over 6 months, in a catheterization laboratory, we measured the occupational dose to the eyes (3 mm dose equivalent) and neck (0.07 mm dose equivalent) of nurses on the right and left sides. We investigated the relationship between lens and neck doses, and found a significant correlation. Hence, it may be possible to estimate the lens dose from the neck badge dose. We also evaluated the appropriate position (left or right) of eye dosimeters for IVR nurses. Although there was little difference between the mean doses to the right and left eyes, that to the right eye was slightly higher. In addition, we investigated whether it is possible to estimate doses received by IVR nurses from patient dose parameters. There were significant correlations between the measured doses to the neck and lens, and the patient dose parameters (fluoroscopy time and air kerma), implying that these parameters could be used to estimate the lens dose. However, it may be difficult to determine the lens dose of IVR nurses accurately from neck badges or patient dose parameters because of variation in the behaviors of nurses and the procedure type. Therefore, neck doses and patient dose parameters do not correlate well with the radiation eye doses of individual IVR nurses measured by personal eye dosimeters. For IVR nurses with higher eye doses, more accurate measurement of the radiation doses is required. We recommend that a lens dosimeter be worn near the eyes to measure the lens dose to IVR nurses accurately, especially those exposed to relatively high doses.

3.
Bioengineering (Basel) ; 10(2)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36829753

RESUMO

Mobile radiography allows for the diagnostic imaging of patients who cannot move to the X-ray examination room. Therefore, mobile X-ray equipment is useful for patients who have difficulty with movement. However, staff are exposed to scattered radiation from the patient, and they can receive potentially harmful radiation doses during radiography. We estimated occupational exposure during mobile radiography using phantom measurements. Scattered radiation distribution during mobile radiography was investigated using a radiation survey meter. The efficacy of radiation-reducing methods for mobile radiography was also evaluated. The dose decreased as the distance from the X-ray center increased. When the distance was more than 150 cm, the dose decreased to less than 1 µSv. It is extremely important for radiological technologists (RTs) to maintain a sufficient distance from the patient to reduce radiation exposure. The spatial dose at eye-lens height increases when the bed height is high, and when the RT is short in stature and abdominal imaging is performed. Maintaining sufficient distance from the patient is also particularly effective in limiting radiation exposure of the eye lens. Our results suggest that the doses of radiation received by staff during mobile radiography are not significant when appropriate radiation protection is used. To reduce exposure, it is important to maintain a sufficient distance from the patient. Therefore, RTs should bear this is mind during mobile radiography.

4.
Sensors (Basel) ; 23(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617110

RESUMO

In 2011, the International Commission on Radiological Protection (ICRP) recommended a significant reduction in the lens-equivalent radiation dose limit, thus from an average of 150 to 20 mSv/year over 5 years. In recent years, the occupational dose has been rising with the increased sophistication of interventional radiology (IVR); management of IVR staff radiation doses has become more important, making real-time radiation monitoring of such staff desirable. Recently, the i3 real-time occupational exposure monitoring system (based on RaySafeTM) has replaced the conventional i2 system. Here, we compared the i2 and i3 systems in terms of sensitivity (batch uniformity), tube-voltage dependency, dose linearity, dose-rate dependency, and angle dependency. The sensitivity difference (batch uniformity) was approximately 5%, and the tube-voltage dependency was <±20% between 50 and 110 kV. Dose linearity was good (R2 = 1.00); a slight dose-rate dependency (~20%) was evident at very high dose rates (250 mGy/h). The i3 dosimeter showed better performance for the lower radiation detection limit compared with the i2 system. The horizontal and vertical angle dependencies of i3 were superior to those of i2. Thus, i3 sensitivity was higher over a wider angle range compared with i2, aiding the measurement of scattered radiation. Unlike the i2 sensor, the influence of backscattered radiation (i.e., radiation from an angle of 180°) was negligible. Therefore, the i3 system may be more appropriate in areas affected by backscatter. In the future, i3 will facilitate real-time dosimetry and dose management during IVR and other applications.


Assuntos
Proteção Radiológica , Radiologia Intervencionista , Humanos , Doses de Radiação , Dosímetros de Radiação , Radiometria
5.
Radiol Phys Technol ; 15(1): 54-62, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35067903

RESUMO

Occupational eye dose monitoring during interventional radiology and interventional cardiology is important to avoid radiation-induced cataracts. The aim of this study was to assess the eye dose correlation with neck dose and patient-related quantities for interventional cardiology physicians and nurses. The originality of this study lies in obtaining correlations between the location of the dosimeter and eye dose radiation readings among different procedures and practitioners. The doses were measured for each procedure (18 procedures of coronary angiography and 16 procedures of percutaneous coronary intervention) using an active personal dosimeter. The eye dose for physicians was not correlated with the neck dose. The eye dose for nurses had a good correlation with the neck dose during both coronary angiography (R2 = 0.91) and percutaneous coronary intervention (R2 = 0.93). Kerma-area product values may be used for a rough estimation of the eye dose for physicians during routine coronary angiography procedures (R2 = 0.76). For nurses, the neck dose is a good proxy for the eye dose during coronary angiography and percutaneous coronary intervention procedures.


Assuntos
Cardiologia , Cristalino , Exposição Ocupacional , Proteção Radiológica , Humanos , Exposição Ocupacional/análise , Doses de Radiação , Proteção Radiológica/métodos , Radiologia Intervencionista
6.
J Radiat Res ; 62(3): 414-419, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-33839782

RESUMO

The new recommendation of the International Commission on Radiological Protection for occupational eye dose is an equivalent dose limit to the eye of 20 mSv year-1, averaged over a 5-year period. This recommendation is a drastic reduction from the previous limit of 150 mSv year-1. Hence, it is important to protect physicians' eyes from X-ray radiation. Particularly in interventional radiology (IVR) procedures, many physicians use protective lead (Pb) glasses to reduce their occupational exposure. This study assessed the shielding effects of novel 0.07 mm Pb glasses. The novel glasses (XR-700) have Pb-acrylic lens molded in three dimensions. We studied the novel type of 0.07 mm Pb glasses over a period of seven consecutive months. The eye dose occupational radiation exposure of seven IVR physicians was evaluated during various procedures. All IVR physicians wore eye dosimeters (DOSIRIS™) close to the left side of the left eye. To calculate the shielding effects of the glasses, this same type of eye dosimeter was worn both inside and outside of the Pb lenses. The average shielding effect of the novel glasses across the seven physicians was 61.4%. Our results suggest an improved shielding effect for IVR physicians that use these glasses. No physician complained that the new glasses were uncomfortable; therefore comfort is not a problem. The lightweight glasses were acceptable to IVR physicians, who often must perform long procedures. Thus, the novel glasses are comfortable and reasonably protective. Based on the results of this study, we recommend that IVR physicians use these novel 0.07 mm Pb glasses to reduce their exposure.


Assuntos
Dispositivos de Proteção dos Olhos , Médicos , Proteção Radiológica , Radiologia Intervencionista , Relação Dose-Resposta à Radiação , Óculos , Humanos , Cristalino/efeitos da radiação , Raios X
7.
Diagnostics (Basel) ; 10(10)2020 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-33086733

RESUMO

In recent years, endovascular treatment of aortic aneurysms has attracted considerable attention as a promising alternative to traditional surgery. Hybrid operating room systems (HORSs) are increasingly being used to perform endovascular procedures. The clinical benefits of endovascular treatments using HORSs are very clear, and these procedures are increasing in number. In procedures such as thoracic endovascular aortic repair (TEVAR) and endovascular aortic repair (EVAR), wires and catheters are used to deliver and deploy the stent graft in the thoracic/abdominal aorta under fluoroscopic control, including DSA. Thus, the radiation dose to the patient is an important issue. We determined radiation dose indicators (the dose-area product (DAP) and air karma (AK) parameters) associated with endovascular treatments (EVAR and TEVAR) using a HORS. As a result, the mean ± standard deviation (SD) DAPs of TEVAR and EVAR were 323.7 ± 161.0 and 371.3 ± 186.0 Gy x cm2, respectively. The mean ± SD AKs of TEVAR and EVAR were 0.92 ± 0.44 and 1.11 ± 0.54 Gy, respectively. The mean ± SD fluoroscopy times of TEVAR and EVAR were 13.4 ± 7.1 and 23.2 ± 11.7 min, respectively. Patient radiation dose results in this study of endovascular treatments using HORSs showed no deterministic radiation effects, such as skin injuries. However, radiation exposure during TEVAR and EVAR cannot be ignored. The radiation dose should be evaluated in HORSs during endovascular treatments. Reducing/optimizing the radiation dose to the patient in HORSs is important.

8.
J Radiat Res ; 61(5): 691-696, 2020 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-32657327

RESUMO

Although the clinical value of fluoroscopically guided respiratory endoscopy (bronchoscopy) is clear, there have been very few studies on the radiation dose received by staff during fluoroscopically guided bronchoscopy. The International Commission on Radiological Protection (ICRP) is suggesting reducing the occupational lens dose limit markedly from 150 to 20 mSv/year, averaged over defined periods of five years. The purpose of this study was to clarify the current occupational eye dose of bronchoscopy staff conducting fluoroscopically guided procedures. We measured the occupational eye doses (3-mm-dose equivalent, Hp(3)) of bronchoscopy staff (physicians and nurses) over a 6-month period. The eye doses of eight physicians and three nurses were recorded using a direct eye dosimeter, the DOSIRIS. We also estimated eye doses using personal dosimeters worn at the neck. The mean ± SD radiation eye doses (DOSIRIS) to physicians and nurses were 7.68 ± 5.27 and 2.41 ± 1.94 mSv/6 months, respectively. The new lens dose limit, 20 mSv/year, may be exceeded among bronchoscopy staff, especially physicians. The eye dose of bronchoscopy staff (both physicians and nurses) was underestimated when measured using a neck dosimeter. Hence, the occupational eye dose of bronchoscopy staff should be monitored. To reduce the occupational eye dose, we recommend that staff performing fluoroscopically guided bronchoscopy wear Pb glasses. correct evaluation of the lens dose [Hp(3)] using an eye dosimeter such as the DOSIRIS is necessary for bronchoscopy staff.


Assuntos
Broncoscopia , Olho/efeitos da radiação , Fluoroscopia , Corpo Clínico , Proteção Radiológica , Relação Dose-Resposta à Radiação , Humanos , Pescoço/efeitos da radiação , Enfermeiras e Enfermeiros , Exposição Ocupacional , Médicos , Doses de Radiação , Exposição à Radiação , Radiometria , Raios X
9.
J Radiol Prot ; 39(3): N19-N26, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31167175

RESUMO

Monitoring and protecting of occupational eye doses in interventional radiology (IR) are very important matters. DOSIRIS™ is the useful solution to estimate the 3 mm dose-equivalent (Hp(3)), and it can be worn behind lead glasses. And DOSIRIS™, adjustable according to 3 axes, it is ideally placed as close to the eye and in contact with the skin. So, DOSIRIS™ will be suitable eye lens dosimeter. However, the fundamental characteristics of the DOSIRIS™ in the diagnostic x-ray energy domain (including that of IR x-ray systems) remain unclear. Here, we evaluated the performance of the dosimeter in that energy range. As a result, the DOSIRIS™ has good fundamental characteristics (batch uniformity, dose linearity, energy dependence, and angular dependence) in the diagnostic x-ray energy domain. We conclude that the DOSIRIS™ has satisfactory basic performance for occupational eye dosimetry in diagnostic x-ray energy settings (including IR x-ray systems).


Assuntos
Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Dosímetros de Radiação , Desenho de Equipamento , Dispositivos de Proteção dos Olhos , Humanos
10.
Bioorg Med Chem Lett ; 29(9): 1143-1147, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30833109

RESUMO

Selective N-methyl-d-aspartate receptor subunit 2B (NR2B) antagonists show potential as analgesic drugs, and do not cause side effects associated with non-selective N-methyl-d-aspartate (NMDA) antagonists. Using a scaffold-hopping approach, we previously identified isoxazole derivative 4 as a potent selective NR2B antagonist. In this study, further scaffold hopping of isoxazole derivative 4 and optimization of its pharmacokinetic profile led to the discovery of the orally bioavailable compound 6v. In a rat study of analgesia, 6v demonstrated analgesic effects against neuropathic pain.


Assuntos
Analgésicos/síntese química , Analgésicos/farmacologia , Desenho de Fármacos , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Analgésicos/química , Analgésicos/farmacocinética , Animais , Masculino , Estrutura Molecular , Ratos , Ratos Sprague-Dawley , Relação Estrutura-Atividade
11.
Cardiovasc Interv Ther ; 34(4): 364-372, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30725361

RESUMO

Preprocedural computed tomography (CT) imaging appears to provide an advantage in localization of the appropriate septal branch targeted for alcohol septal ablation (ASA). The objective of this study was to compare the clinical backgrounds, procedural characteristics, and outcomes of patients who underwent ASA with preprocedural CT assessment against those without CT assessment. Thirty consecutive patients with obstructive hypertrophic cardiomyopathy who underwent ASA were retrospectively included. Patients who underwent preprocedural CT (CT-guided ASA group, n = 11) were compared with patients who underwent ASA without CT (traditional ASA group, n = 19). The CT-guided ASA group had a significantly lower number of approached target vessels (1 [interquartile range {IQR}, 1-2] vs. 2 [IQR, 2-3], P = 0.036) and non-ablated target vessels (0 [IQR, 0-1] vs. 1 [IQR, 0-2], P = 0.031) than the traditional ASA group. There were no differences between the two groups in total fluoroscopy time, the amount of delivered radiation dose, and the volume of contrast medium used during the procedures. There were also no differences between the two groups in procedural success rate and improvement of left ventricular outflow tract gradient and New York Heart Association functional class at 1 month follow-up. CT had a significant impact on the ASA procedure diminishing the number of target vessels, and could be a reliable assessment modality to build its procedural strategy.


Assuntos
Técnicas de Ablação/métodos , Cardiomiopatia Hipertrófica/cirurgia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Tomografia Computadorizada Multidetectores , Idoso , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Etanol , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos
14.
Sci Rep ; 7(1): 569, 2017 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-28373715

RESUMO

It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.


Assuntos
Cardiologistas , Olho/efeitos da radiação , Exposição Ocupacional , Doses de Radiação , Exposição à Radiação , Radiologia Intervencionista , Humanos , Enfermeiras e Enfermeiros , Exposição Ocupacional/efeitos adversos , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiometria
15.
J Digit Imaging ; 29(1): 38-42, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26264731

RESUMO

As the use of diagnostic X-ray equipment with flat panel detectors (FPDs) has increased, so has the importance of proper management of FPD systems. To ensure quality control (QC) of FPD system, an easy method for evaluating FPD imaging performance for both stationary and moving objects is required. Until now, simple rotatable QC phantoms have not been available for the easy evaluation of the performance (spatial resolution and dynamic range) of FPD in imaging moving objects. We developed a QC phantom for this purpose. It consists of three thicknesses of copper and a rotatable test pattern of piano wires of various diameters. Initial tests confirmed its stable performance. Our moving phantom is very useful for QC of FPD images of moving objects because it enables visual evaluation of image performance (spatial resolution and dynamic range) easily.


Assuntos
Imagens de Fantasmas , Controle de Qualidade , Intensificação de Imagem Radiográfica/instrumentação , Ecrans Intensificadores para Raios X/normas , Movimento (Física) , Intensificação de Imagem Radiográfica/normas
16.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(12): 1215-20, 2015 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-26685833

RESUMO

In recent years, aortic aneurysm treatment with stent graft grafting in the X-ray fluoroscopy is increasing. This is an endovascular therapy, because it is a treatment which includes the risk of radiation damage, having to deal with radiation damage, to know in advance is important. In this study, in order to grasp the trend of exposure stent graft implantation in a hybrid operating room (OR) system, focusing on clinical data (entrance skin dose and fluoroscopy time), was to count the total. In TEVAR and EVAR, fluoroscopy time became 13.40 ± 7.27 minutes, 23.67 ± 11.76 minutes, ESD became 0.87 ± 0.41 mGy, 1.11 ± 0.57 mGy. (fluoroscopy time of EVAR was 2.0 times than TEVAR. DAP of EVAR was 1.2 times than TEVAR.) When using the device, adapted lesions and usage are different. This means that care changes in exposure-related factors. In this study, exposure trends of the stent graft implantation was able to grasp. It can be a helpful way to reduce/optimize the radiation dose in a hybrid OR system.


Assuntos
Prótese Vascular , Doses de Radiação , Stents , Idoso , Aneurisma Aórtico/cirurgia , Feminino , Humanos , Masculino , Salas Cirúrgicas
17.
Acta Cardiol ; 70(3): 299-306, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26226703

RESUMO

OBJECTIVE: Although many patients benefit greatly from fluoroscopically guided intervention (IVR) procedures such as percutaneous coronary intervention (PCI), one of the major disadvantages associated with these procedures, such as cardiac IVR, is the increased patient radiation dose. This study compared the entrance surface doses of x-ray equipment for cardiac IVR at the same seven cardiac catheterization laboratories between today and the past to determine the radiation doses of current cardiac IVR x-ray systems. METHODS AND RESULTS: This study was conducted in 2001, 2007, and 2014 at the same seven cardiac catheterization laboratories in and around Sendai City, Japan. The entrance surface doses with cineangiography and fluoroscopy were compared in 2001 (11 x-ray systems), 2007, and 2014 (12 x-ray systems) using a 20-cm-thick acrylic plate and skin dose monitor. The x-ray conditions used in the measurements, including the image receptor field magnification mode and the recording speed for cineangiography and fluoroscopy, were those-normally used in the facilities performing PCI. Although presently, the entrance doses of x-ray equipment used for cardiac IVR tend to be lower than previously (fluoroscopy dose in 2001, 19.3 +/- 6.3 mGy/min; in 2014, 13.2 +/- 6.5 mGy/min), some equipment has a high radiation dose. In addition, the dose differences of the x-ray systems in 2014 were greater than those in the past (fluoroscopy dose in 2001, 3.4-fold; in 2014, 10.5-fold). CONCLUSIONS: In IVR procedures, managing the radiation dose of cardiac IVR x-ray systems is a very important issue. Periodical measurement of the radiation dose of the x-ray equipment used for both cineangiography and fluoroscopy for cardiac IVR is necessary.


Assuntos
Coração/diagnóstico por imagem , Doses de Radiação , Radiologia Intervencionista , Cineangiografia/tendências , Fluoroscopia/tendências , Humanos , Radiologia Intervencionista/instrumentação , Radiologia Intervencionista/tendências
18.
Health Phys ; 104(1): 97-101, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23192093

RESUMO

X-ray equipment should be routinely checked for optimal imaging performance and appropriate radiation dose. Recently, the use of diagnostic x-ray equipment with flat panel detectors (FPDs) has increased instead of image intensifier (II) and/or screen film systems. In addition, it is necessary to maintain the performance of FPD systems. Unfortunately, no simple quality control (QC) phantom is available for easy evaluation of FPD image performance. This manuscript suggests a novel simple and inexpensive QC phantom for radiography and fluoroscopy. The authors made a new QC phantom for FPD systems to evaluate the spatial resolution, low-contrast resolution, and dynamic range on single (one-shot) x-ray exposures. The phantom consists of three copper thicknesses (0.5, 1.5, and 3.0 mm), an aluminum stepwedge (0.1-2.7 mm), and piano wire of various diameters (0.08-0.5 mm). They also performed an initial check of the new phantom using a FPD system (fluoroscopic and radiographic images). The new phantom is simple and inexpensive to make. This simple phantom is very useful for QC of FPD systems because a visual evaluation of image performance in three thicknesses of copper (low, intermediate, and high attenuation) is readily available with a single exposure. This simple method for daily checking of FPD systems (radiography and fluoroscopy) using the phantom constitutes an easy way to routinely check image performance and will be useful for QC.


Assuntos
Intensificação de Imagem Radiográfica/normas , Ecrans Intensificadores para Raios X/normas , Humanos , Imagens de Fantasmas , Controle de Qualidade
19.
AJR Am J Roentgenol ; 200(1): 138-41, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255753

RESUMO

OBJECTIVE: Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. MATERIALS AND METHODS: We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. RESULTS: The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. CONCLUSION: The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.


Assuntos
Exposição Ocupacional , Doses de Radiação , Radiologia Intervencionista , Cateterismo Cardíaco , Cineangiografia , Angiografia Coronária , Dosimetria Fotográfica , Humanos , Recursos Humanos de Enfermagem Hospitalar , Doenças Profissionais/prevenção & controle , Intervenção Coronária Percutânea , Médicos , Lesões por Radiação/prevenção & controle , Proteção Radiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...