1.
Clin Orthop Relat Res ; 473(12): 3822-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26113111

RESUMO

BACKGROUND: Charnley low-friction torque total hip arthroplasty (THA) remains the gold standard in THA. The main cause for failure is wear of the socket. Highly crosslinked polyethylene (HXLPE) has been associated with reduced wear rates. Also, oxidized zirconium has shown in vitro reduced wear rates. However, to our knowledge, there are no data comparing oxidized zirconium femoral heads with metal heads against HXLPE or ultrahigh-molecular-weight polyethylene (UHMWPE) when 22.25-mm bearings were used, which was the same size that performed so well in Charnley-type THAs. QUESTIONS/PURPOSES: We hypothesized that after a minimal 4-year followup (1) use of HXLPE would result in lower radiographic wear than UHMWPE when articulating with a stainless steel head or with an oxidized zirconium head; (2) use of oxidized zirconium would result in lower radiographic wear than stainless steel when articulating with UHMWPE and HXLPE; and (3) there would be no difference in terms of Merle d'Aubigné scores between the bearing couple combinations. METHODS: One hundred patients were randomized to receive cemented THA with either oxidized zirconium or a stainless steel femoral head. UHMWPE was used in the first 50 patients, whereas HXLPE was used in the next 50 patients. There were 25 patients in each of the four bearing couple combinations. All other parameters were identical in both groups. Complete followup was available in 86 of these patients. Femoral head penetration was measured using a validated computer-assisted method dedicated to all-polyethylene sockets. Clinical results were compared between the groups using the Merle d'Aubigné score. RESULTS: In the UHMWPE series, the median steady-state penetration rate from 1 year onward was 0.03 mm/year (range, 0.003-0.25 mm/year) in the oxidized zirconium group versus 0.11 mm/year (range, 0.03-0.29 mm/year) in the metal group (difference of medians 0.08, p < 0.001). In the HXLPE series, the median steady-state penetration rate from 1 year onward was 0.02 mm/year (range, -0.32 to 0.07 mm/year) in the oxidized zirconium group versus 0.05 mm/year (range, -0.39 to 0.11 mm/year) in the metal group (difference of medians 0.03, p < 0.001). The Merle d'Aubigné scores were no different between the groups with a median of 18 in each of the groups (range, 16-18). CONCLUSIONS: This study demonstrated femoral head penetration was reduced by oxidized zirconium when compared with metal on both UHMWPE and HXLPE. However, apart the metal-UHMWE group, all other groups had a steady-state penetration rate well below the osteolysis threshold with a low difference between groups that might not be clinically important at this point. Longer-term followup is needed to warrant whether wear reduction will generate less occurrence of osteolysis and aseptic loosening. LEVEL OF EVIDENCE: Level II, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Cimentos Ósseos/uso terapêutico , Cabeça do Fêmur/cirurgia , Articulação do Quadril/cirurgia , Prótese de Quadril , Polietilenos/química , Falha de Prótese , Zircônio/química , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Reagentes de Ligações Cruzadas/química , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/fisiopatologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Peso Molecular , Osteólise/etiologia , Osteólise/prevenção & controle , Oxirredução , Paris , Desenho de Prótese , Radiografia , Aço Inoxidável , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
J Pediatr Orthop B ; 20(3): 142-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20539242

RESUMO

Dysplasia epiphysealis hemimelica (DEH) or Trevor's disease is a rare disorder affecting the epiphyses and short bones of the limbs, and characterized by a benign overgrowth of the medial-half of the epiphysis resembling osteochondroma. Upper limb involvement is very rare and most commonly affects the carpal bones. Only five established cases of DEH around the elbow were found in the orthopedic literature. We herein report an additional case of Trevor's disease of the elbow in a child with a symptomatic ulnar nerve compression and its management. To the best of our knowledge, this is the first case of DEH of the elbow presenting with nerve compromise.


Assuntos
Articulação do Cotovelo/anormalidades , Síndromes de Compressão do Nervo Ulnar/patologia , Doenças do Desenvolvimento Ósseo/complicações , Doenças do Desenvolvimento Ósseo/patologia , Doenças do Desenvolvimento Ósseo/cirurgia , Neoplasias Ósseas/complicações , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/cirurgia , Criança , Fêmur/anormalidades , Fêmur/patologia , Fêmur/cirurgia , Humanos , Masculino , Osteocondroma/complicações , Osteocondroma/diagnóstico , Osteocondroma/cirurgia , Recuperação de Função Fisiológica , Tíbia/anormalidades , Tíbia/patologia , Tíbia/cirurgia , Resultado do Tratamento , Síndromes de Compressão do Nervo Ulnar/etiologia , Síndromes de Compressão do Nervo Ulnar/cirurgia