Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(6): 064505, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35777998

RESUMO

We describe a liquid-cryogen free cryostat with ultra-low vibration levels, which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3-10 mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.

2.
Rev Sci Instrum ; 92(5): 054502, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243344

RESUMO

We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a Michelson interferometer. The system achieved noise levels of ∼200prad/Hz between 0.2 and 30 Hz and ∼10prad/Hz above 100 Hz. Such a system can be applied to a broad range of fields from the study of rotational seismic motion and elastogravity signals to gravitational wave observation and tests of gravity.

3.
Phys Rev Lett ; 122(23): 231301, 2019 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-31298907

RESUMO

We analyzed a 6.7-yr span of data from a rotating torsion-pendulum containing ≈10^{23} polarized electrons to search for the "wind" arising from ultralight, axionlike dark matter with masses between 10^{-23} and 10^{-18} eV/c^{2}. Over much of this range we set a 95% confidence limit F_{a}/C_{e}>2×10^{15} eV on the axionlike decay constant.

4.
Rev Sci Instrum ; 84(9): 095007, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24089858

RESUMO

We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/√Hz sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressing common-mode noise sources. The condensing lens reduces optical aberrations, increases intensity, and improves image quality. To further improve the stability of the device at low frequencies the body of the autocollimator is designed to reduce temperature variations and their effects. A new data processing technique was developed in order to suppress the effects of imperfections in the CCD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA