Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Optica ; 10(7): 880-887, 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37841216

RESUMO

X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phase-contrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues. We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against known-material phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart. We believe that the simplicity of the setup we are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.

2.
Opt Express ; 30(24): 43209-43222, 2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36523024

RESUMO

Cycloidal computed tomography provides high-resolution images within relatively short scan times by combining beam modulation with dedicated under-sampling. However, implementing the technique relies on accurate knowledge of the sample's motion, particularly in the case of continuous scans, which is often unavailable due to hardware or software limitations. We have developed an easy-to-implement position tracking technique using a sharp edge, which can provide reliable information about the trajectory of the sample and thus improve the reconstruction process. Furthermore, this approach also enables the development of other innovative sampling schemes, which may otherwise be difficult to implement.

3.
Sci Rep ; 12(1): 893, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35042961

RESUMO

In x-ray computed tomography (CT), the achievable image resolution is typically limited by several pre-fixed characteristics of the x-ray source and detector. Structuring the x-ray beam using a mask with alternating opaque and transmitting septa can overcome this limit. However, the use of a mask imposes an undersampling problem: to obtain complete datasets, significant lateral sample stepping is needed in addition to the sample rotation, resulting in high x-ray doses and long acquisition times. Cycloidal CT, an alternative scanning scheme by which the sample is rotated and translated simultaneously, can provide high aperture-driven resolution without sample stepping, resulting in a lower radiation dose and faster scans. However, cycloidal sinograms are incomplete and must be restored before tomographic images can be computed. In this work, we demonstrate that high-quality images can be reconstructed by applying the recently proposed Mixed Scale Dense (MS-D) convolutional neural network (CNN) to this task. We also propose a novel training approach by which training data are acquired as part of each scan, thus removing the need for large sets of pre-existing reference data, the acquisition of which is often not practicable or possible. We present results for both simulated datasets and real-world data, showing that the combination of cycloidal CT and machine learning-based data recovery can lead to accurate high-resolution images at a limited dose.

4.
Acta Biomater ; 141: 290-299, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35051630

RESUMO

Tissue engineering (TE) aims to generate bioengineered constructs which can offer a surgical treatment for many conditions involving tissue or organ loss. Construct generation must be guided by suitable assessment tools. However, most current tools (e.g. histology) are destructive, which restricts evaluation to a single-2D anatomical plane, and has no potential for assessing constructs prior to or following their implantation. An alternative can be provided by laboratory-based x-ray phase contrast computed tomography (PC-CT), which enables the extraction of 3D density maps of an organ's anatomy. In this work, we developed a semi-automated image processing pipeline dedicated to the analysis of PC-CT slices of oesophageal constructs. Visual and quantitative (density and morphological) information is extracted on a volumetric basis, enabling a comprehensive evaluation of the regenerated constructs. We believe the presented tools can enable the successful regeneration of patient-specific oesophagus, and bring comparable benefit to a wide range of TE applications. STATEMENT OF SIGNIFICANCE: Phase contrast computed tomography (PC-CT) is an imaging modality which generates high resolution volumetric density maps of biological tissue. In this work, we demonstrate the use of PC-CT as a new tool for guiding the progression of an oesophageal tissue engineering (TE) protocol. Specifically, we developed a semi-automated image-processing pipeline which analyses the oesophageal PC-CT slices, extracting visual and quantitative (density and morphological) information. This information was proven key for performing a comprehensive evaluation of the regenerated constructs, and cannot be obtained through existing assessment tools primarily due to their destructive nature (e.g. histology). This work paves the way for using PC-CT in a wide range of TE applications which can be pivotal for unlocking the potential of this field.


Assuntos
Engenharia Tecidual , Tomografia Computadorizada por Raios X , Humanos , Processamento de Imagem Assistida por Computador , Microscopia de Contraste de Fase , Engenharia Tecidual/métodos , Tomografia Computadorizada por Raios X/métodos , Raios X
5.
IEEE Trans Med Imaging ; 41(5): 1188-1195, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34941505

RESUMO

The assessment of margin involvement is a fundamental task in breast conserving surgery to prevent recurrences and reoperations. It is usually performed through histology, which makes the process time consuming and can prevent the complete volumetric analysis of large specimens. X-ray phase contrast tomography combines high resolution, sufficient penetration depth and high soft tissue contrast, and can therefore provide a potential solution to this problem. In this work, we used a high-resolution implementation of the edge illumination X-ray phase contrast tomography based on "pixel-skipping" X-ray masks and sample dithering, to provide high definition virtual slices of breast specimens. The scanner was originally designed for intra-operative applications in which short scanning times were prioritised over spatial resolution; however, thanks to the versatility of edge illumination, high-resolution capabilities can be obtained with the same system simply by swapping x-ray masks without this imposing a reduction in the available field of view. This makes possible an improved visibility of fine tissue strands, enabling a direct comparison of selected CT slices with histology, and providing a tool to identify suspect features in large specimens before slicing. Combined with our previous results on fast specimen scanning, this works paves the way for the design of a multi-resolution EI scanner providing intra-operative capabilities as well as serving as a digital pathology system.


Assuntos
Técnicas Histológicas , Iluminação , Microscopia de Contraste de Fase/métodos , Radiografia , Raios X
6.
Med Phys ; 48(10): 5884-5896, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34387879

RESUMO

PURPOSE: In this work, an analytical model describing the noise in the retrieved three contrast channels, transmission, refraction, and ultra small-angle scattering, obtained with edge illumination X-ray phase-based imaging system is presented and compared to experimental data. METHODS: In EI, images acquired at different displacements of the presample mask (i.e., different illumination levels referred to as points on the "illumination curve"), followed by pixel-wise curve fitting, are exploited to quantitatively retrieve the three contrast channels. Therefore, the noise in the final image will depend on the error associated with the fitting process. We use a model based on the derivation of the standard error on fitted parameters, which relies on the calculation of the covariance matrix, to estimate the noise and the cross-channel correlation as a function of the position of the sampling points. In particular, we investigated the most common cases of 3 and 5 sampling points. In addition, simulations have been used to better understand the role of the integration time for each sampling point. Finally, the model is validated by comparison with the experimental data acquired with an edge illumination setup based on a tungsten rotating anode X-ray source and a photon counting detector. RESULTS: We found a good match between the predictions of the model and the experimental data. In particular, for the investigated cases, an arrangement of the sampling points leading to minimum noise and cross-channel correlation can be found. Simulations revealed that, given a fixed overall scanning time, its distribution into the smallest possible number of sampling points needed for phase retrieval leads to minimum noise thanks to higher statistics per point. CONCLUSIONS: This work presents an analytical model describing the noise in the various contrast channels retrieved in edge illumination as a function of the illumination curve sampling. In particular, an optimal sampling scheme leading to minimum noise has been determined for the case where 3 or 5 sampling points are used, which represent two of the most common acquisition schemes. In addition, the correlation between noise in the different channels and the role of the number of points and exposure time have been also investigated. In general, our results suggest a series of procedures that should be followed in order to optimize the experimental acquisitions.


Assuntos
Iluminação , Fótons , Imagens de Fantasmas , Radiografia , Raios X
7.
Med Phys ; 48(10): 6524-6530, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34169514

RESUMO

PURPOSE: Cycloidal computed tomography is a novel imaging concept which combines a highly structured x-ray beam, offset lateral under-sampling, and mathematical data recovery to obtain high-resolution images efficiently and flexibly, even with relatively large source focal spots and detector pixels. The method reduces scanning time and, potentially, delivered dose compared to other sampling schemes. This study aims to present and discuss several implementation strategies for cycloidal computed tomography (CT) in order to increase its ease of use and facilitate uptake within the imaging community. METHODS: The different implementation strategies presented are step-and-shoot, continuous unidirectional, continuous back-and-forth, and continuous pixel-wise scanning. In step-and-shoot scans the sample remains stationary while frames are acquired, whereas in all other cases the sample moves through the scanner continuously. The difference between the continuous approaches is the trajectory by which the sample moves within the field of view. RESULTS: All four implementation strategies are compatible with a standard table-top x-ray setup. With the experimental setup applied here, step-and-shoot acquisitions yield the best spatial resolution (around 30 µm), but are the most time-consuming (1.4 h). Continuous unidirectional and back-and-forth images have resolution between 30 and 40 µm, and are faster (35 min). Continuous pixel-wise images are equally time-efficient, although technical challenges caused a small loss in image quality with a resolution of about 50 µm. CONCLUSION: The authors show that cycloidal CT can be implemented in a variety of ways with high quality results. They believe this posits cycloidal CT as a powerful imaging alternative to more time-consuming and less flexible methods in the field.


Assuntos
Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Radiografia , Raios X
8.
Sci Rep ; 11(1): 3663, 2021 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-33574584

RESUMO

Margins of wide local excisions in breast conserving surgery are tested through histology, which can delay results by days and lead to second operations. Detection of margin involvement intraoperatively would allow the removal of additional tissue during the same intervention. X-ray phase contrast imaging (XPCI) provides soft tissue sensitivity superior to conventional X-rays: we propose its use to detect margin involvement intraoperatively. We have developed a system that can perform phase-based computed tomography (CT) scans in minutes, used it to image 101 specimens approximately half of which contained neoplastic lesions, and compared results against those of a commercial system. Histological analysis was carried out on all specimens and used as the gold standard. XPCI-CT showed higher sensitivity (83%, 95% CI 69-92%) than conventional specimen imaging (32%, 95% CI 20-49%) for detection of lesions at margin, and comparable specificity (83%, 95% CI 70-92% vs 86%, 95% CI 73-93%). Within the limits of this study, in particular that specimens obtained from surplus tissue typically contain small lesions which makes detection more difficult for both methods, we believe it likely that the observed increase in sensitivity will lead to a comparable reduction in the number of re-operations.


Assuntos
Neoplasias da Mama/cirurgia , Mama/cirurgia , Margens de Excisão , Mastectomia Segmentar , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Microscopia de Contraste de Fase , Radiografia , Tomografia Computadorizada por Raios X
9.
Opt Express ; 28(1): 1-19, 2020 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-32118936

RESUMO

Edge-illumination X-ray phase-contrast tomography (EIXPCT) is an emerging technique that enables practical phase-contrast imaging with laboratory-based X-ray sources. A joint reconstruction method was proposed for reconstructing EIXPCT images, enabling novel flexible data-acquisition designs. However, only limited efforts have been devoted to optimizing data-acquisition designs for use with the joint reconstruction method. In this study, several promising designs are introduced, such as the constant aperture position (CAP) strategy and the alternating aperture position (AAP) strategy covering different angular ranges. In computer-simulation studies, these designs are analyzed and compared. Experimental data are employed to test the designs in real-world applications. All candidate designs are also compared for their implementation complexity. The tradeoff between data-acquisition time and image quality is discussed.

10.
Phys Med Biol ; 65(10): 105007, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-31896094

RESUMO

Edge-illumination x-ray phase-contrast tomography (EIXPCT) is a promising imaging technology where partially opaque masks are utilized with laboratory-based x-ray sources to estimate the distribution of the complex-valued refractive index. EIXPCT resolution is mainly determined by the period of a sample mask, but can be significantly improved by a dithering technique. Here, dithering means that multiple images per tomographic view angle are acquired as the object is moved over sub-pixel distances. Drawbacks of dithering include increased data-acquisition times and radiation doses. Motivated by the flexibility in data-acquisition designs enabled by a recently developed joint reconstruction method, a novel partial-dithering strategy for EIXPCT data-acquisition is proposed. In this strategy, dithering is implemented at only a subset of the tomographic view angles. The strategy can result in spatial resolution comparable to that of the conventional full-dithering strategy, where dithering is performed at every view angle, but the acquisition time is substantially decreased. Here, the effect of dithering parameters on image resolution is explored.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Iluminação , Tomografia Computadorizada por Raios X/instrumentação , Imagens de Fantasmas , Refratometria
11.
Mol Imaging Biol ; 22(3): 539-548, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31250331

RESUMO

PURPOSE: To enable a preliminary assessment of the suitability of edge illumination (EI) x-ray phase contrast (XPC) micro x-ray computed tomography (micro-CT) to preclinical imaging. Specifically, to understand how different acquisition schemes and their combination with dedicated data processing affect contrast-to-noise ratio (CNR) and spatial resolution, while providing control over scan time and radiation dose delivery. PROCEDURES: Deceased mice (n = 3) were scanned with an EI XPC micro-CT setup operated under different settings, leading to scan times between 18 h and 13 min. For the shortest scan, the entrance dose was measured with a calibrated PTW 23344 ion chamber. Different data processing methods were applied, retrieving either separate attenuation and phase images, or hybrid (combined attenuation and phase) images. A quantitative comparison was performed based on CNR and spatial resolution measurements for a soft tissue interface. RESULTS: All phase-based images have led to a higher CNR for the considered soft tissue interface than the attenuation image, independent of scan time. The best relative CNR (a sixfold increase) was observed in one of the hybrid images. Spatial resolution was found to be connected to scan time, with a resolution of approximately 20 µm and 60 µm achieved for the longest and shortest scans, respectively. An entrance dose of approximately 300 mGy was estimated for the scan performed within 13 min. CONCLUSIONS: Despite their preliminary nature, our results suggest that EI XPC bears potential for enhancing the utility of preclinical micro-CT, and, pending further research and development, could ultimately become a valuable technique in this field.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia de Contraste de Fase/métodos , Imagem Corporal Total/métodos , Microtomografia por Raio-X/métodos , Algoritmos , Animais , Camundongos , Doses de Radiação , Razão Sinal-Ruído
12.
Phys Med Biol ; 64(23): 235005, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31569079

RESUMO

A significant number of patients receiving breast-conserving surgery (BCS) for invasive carcinoma and ductal carcinoma in situ (DCIS) may need reoperation following tumor-positive margins from final histopathology tests. All current intraoperative margin assessment modalities have specific limitations. As a first step towards the development of a compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast, we prove that the system's dimensions can be reduced without affecting imaging performance. We analysed the variation in noise and contrast to noise ratio (CNR) with decreasing system length using the edge illumination x-ray phase contrast imaging setup. Two-(planar) and three-(computed tomography (CT)) dimensional imaging acquisitions of custom phantoms and a breast tissue specimen were made. Dedicated phase retrieval algorithms were used to separate refraction and absorption signals. A 'single-shot' retrieval method was also used, to retrieve thickness map images, due to its simple acquisition procedure and reduced acquisition times. Experimental results were compared to numerical simulations where appropriate. The relative contribution of dark noise signal in integrating detectors is significant for low photon count statistics acquisitions. Under constant exposure factors and magnification, a more compact system provides an increase in CNR. Superior CNR results were obtained for refraction and thickness map images when compared to absorption images. Results indicate that the 'single-shot' acquisition method is preferable for a compact CT intraoperative specimen scanner; it allows for shorter acquisition times and its combination of the absorption and refraction signals ultimately leads to a higher contrast. The first CT images of a breast specimen acquired with the compact system provided promising results when compared to those of the longer length system.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Algoritmos , Neoplasias da Mama/cirurgia , Feminino , Humanos , Período Intraoperatório , Margens de Excisão , Mastectomia Segmentar/métodos , Radiografia , Reoperação , Razão Sinal-Ruído , Raios X
13.
Phys Med Biol ; 64(20): 205008, 2019 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-31509810

RESUMO

Iterative tomographic reconstruction has been established as a viable alternative for data analysis in phase-sensitive x-ray imaging based on the edge-illumination principle. However, previously published approaches did not account for drifts of optical elements during a scan, which can lead to artefacts. Up to now, the strategy to reduce these artefacts was to acquire additional intermediate flat field images, which were used to correct the sinograms. Here, we expand the theoretical model to take these effects into account and demonstrate a significant reduction of (ring)-artefacts in the final reconstructions, while allowing for a significant reduction of scan time and dose. We further improve the model by including the capability to reconstruct combined absorption and phase contrast slices, which we experimentally demonstrate to deliver improved contrast to noise ratios compared to previously employed single shot approaches.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Artefatos , Simulação por Computador , Humanos , Iluminação , Raios X
14.
Opt Express ; 25(10): 11984-11996, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28788753

RESUMO

In this paper we present a single-image phase retrieval algorithm for multi-material samples, developed for the edge illumination (EI) X-ray phase contrast imaging method. The theoretical derivation is provided, along with any assumptions made. The algorithm is evaluated quantitatively using both simulated and experimental results from a computed tomography (CT) scan using the EI laboratory implementation. Qualitative CT results are provided for a biological sample containing both bone and soft-tissue. Using a single EI image per projection and knowledge of the complex refractive index, the algorithm can accurately retrieve the interface between a given pair of materials. A composite CT slice can be created by splicing together multiple CT reconstructions, each retrieved for a different pair of materials.

15.
Opt Lett ; 42(3): 619-622, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28146542

RESUMO

Edge illumination x-ray phase-contrast tomography (EIXPCT) is an emerging x-ray phase-contrast tomography technique for reconstructing the complex-valued x-ray refractive index distribution of an object. Conventional image reconstruction approaches for EIXPCT require multiple images to be acquired at each tomographic view angle. This contributes to prolonged data-acquisition times and elevated radiation doses, which can hinder in vivo applications. In this work, a new "single-shot" method is proposed for joint reconstruction (JR) of the real and imaginary-valued components of the refractive index distribution from a tomographic data set that contains only a single image acquired at each view angle. The proposed method is predicated on a nonlinear formulation of the inverse problem that is solved by using a gradient-based optimization method. The method is validated and investigated using computer-simulated and experimental EIXPCT data sets.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia/métodos , Fenômenos Ópticos , Raios X
16.
Phys Med ; 32(12): 1759-1764, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27836637

RESUMO

PURPOSE: Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has been under development at University College London in recent years, and has shown great potential for both laboratory and synchrotron applications. In this work, we propose a new acquisition and processing scheme. Contrary to existing retrieval methods for EI, which require as input two images acquired in different setup configurations, the proposed approach can retrieve an approximate map of the X-ray phase from a single image, thus significantly simplifying the acquisition procedure and reducing data collection times. METHODS: The retrieval method is analytically derived, based on the assumption of a quasi-homogeneous object, i.e. an object featuring a constant ratio between refractive index and absorption coefficient. The noise properties of the input and retrieved images are also theoretically analyzed under the developed formalism. The method is applied to experimental synchrotron images of a biological object. RESULTS: The experimental results show that the method can provide high-quality images, where the "edge" signal typical of XPCI images is transformed to an "area" contrast that enables an easier interpretation of the sample geometry. Moreover, the retrieved images confirm that the method is highly stable against noise. CONCLUSIONS: We anticipate that the developed approach will become the method of choice for a variety of applications of EI XPCI, thanks to its ability to simplify the acquisition procedure and reduce acquisitions time and dose to the sample. Future work will focus on the adaptation of the method to computed tomography and to polychromatic radiation from X-ray tubes.


Assuntos
Iluminação , Radiografia/instrumentação , Razão Sinal-Ruído , Processamento de Imagem Assistida por Computador , Síncrotrons , Madeira , Raios X
17.
Sci Rep ; 6: 31197, 2016 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-27502296

RESUMO

Edge illumination x-ray phase contrast tomography is a recently developed imaging technique which enables three-dimensional visualisation of low-absorbing materials. Dedicated phase retrieval algorithms can provide separate computed tomography (CT) maps of sample absorption, refraction and scattering properties. In this paper we propose a novel "modified local retrieval" method which is capable of accurately retrieving sample properties in a range of realistic, non-ideal imaging environments. These include system misalignment, defects in the used optical elements and system geometry variations over time due to vibrations or temperature fluctuations. System instabilities were analysed, modelled and incorporated into a simulation study. As a result, an additional modification was introduced to the retrieval procedure to account for changes in the imaging system over time, as well as local variations over the field of view. The performance of the proposed method was evaluated in comparison to a previously used "global retrieval" method by applying both approaches to experimental CT data of a rat's heart acquired in a non-ideal environment. The use of the proposed method resulted in the removal of major artefacts, leading to a significant improvement in image quality. This method will therefore enable acquiring high-resolution, reliable CT data of large samples in realistic settings.

18.
Br J Radiol ; 89(1058): 20150565, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26612467

RESUMO

OBJECTIVE: To demonstrate the feasibility of using X-ray phase-contrast tomography to assess internal organs in a post-mortem piglet model, as a possible non-invasive imaging autopsy technique. METHODS: Tomographic images of a new-born piglet were obtained using a free-space propagation X-ray phase-contrast imaging setup at a synchrotron (European Synchrotron Radiation Facility, Grenoble, France). A monochromatic X-ray beam (52 keV) was used in combination with a detector pixel size of 46 × 46 µm(2). A phase-retrieval algorithm was applied to all projections, which were then reconstructed into tomograms using the filtered-back projection algorithm. Images were assessed for diagnostic quality. RESULTS: Images obtained with the free-space propagation setup presented high soft-tissue contrast and sufficient resolution for resolving organ structure. All of the main body organs (heart, lungs, kidneys, liver and intestines) were easily identified and adequately visualized. In addition, grey/white matter differentiation in the cerebellum while still contained within the skull was shown. CONCLUSION: The feasibility of using X-ray phase-contrast tomography as a post-mortem imaging technique in an animal model has been demonstrated. Future studies will focus on translating this experiment to a laboratory-based setup. ADVANCES IN KNOWLEDGE: Appropriate image processing and analysis enable the simultaneous visualization of both soft- and hard-tissue structures in X-ray phase-contrast images of a complex, thick sample.


Assuntos
Autopsia/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Animais Recém-Nascidos , Estudos de Viabilidade , Interpretação de Imagem Radiográfica Assistida por Computador , Suínos , Tomografia Computadorizada por Raios X/instrumentação
19.
Sci Rep ; 5: 18156, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26657471

RESUMO

Acellular scaffolds obtained via decellularization are a key instrument in regenerative medicine both per se and to drive the development of future-generation synthetic scaffolds that could become available off-the-shelf. In this framework, imaging is key to the understanding of the scaffolds' internal structure as well as their interaction with cells and other organs, including ideally post-implantation. Scaffolds of a wide range of intricate organs (esophagus, lung, liver and small intestine) were imaged with x-ray phase contrast computed tomography (PC-CT). Image quality was sufficiently high to visualize scaffold microarchitecture and to detect major anatomical features, such as the esophageal mucosal-submucosal separation, pulmonary alveoli and intestinal villi. These results are a long-sought step for the field of regenerative medicine; until now, histology and scanning electron microscopy have been the gold standard to study the scaffold structure. However, they are both destructive: hence, they are not suitable for imaging scaffolds prior to transplantation, and have no prospect for post-transplantation use. PC-CT, on the other hand, is non-destructive, 3D and fully quantitative. Importantly, not only do we demonstrate achievement of high image quality at two different synchrotron facilities, but also with commercial x-ray equipment, which makes the method available to any research laboratory.


Assuntos
Esôfago/anatomia & histologia , Intestino Delgado/anatomia & histologia , Fígado/anatomia & histologia , Pulmão/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Animais , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Coelhos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Síncrotrons , Engenharia Tecidual/métodos , Alicerces Teciduais , Tomografia Computadorizada por Raios X/instrumentação
20.
J Synchrotron Radiat ; 22(4): 1072-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26134813

RESUMO

A method is proposed which enables the retrieval of the thickness or of the projected electron density of a sample from a single input image acquired with an edge illumination phase-contrast imaging setup. The method assumes the case of a quasi-homogeneous sample, i.e. a sample with a constant ratio between the real and imaginary parts of its complex refractive index. Compared with current methods based on combining two edge illumination images acquired in different configurations of the setup, this new approach presents advantages in terms of simplicity of acquisition procedure and shorter data collection time, which are very important especially for applications such as computed tomography and dynamical imaging. Furthermore, the fact that phase information is directly extracted, instead of its derivative, can enable a simpler image interpretation and be beneficial for subsequent processing such as segmentation. The method is first theoretically derived and its conditions of applicability defined. Quantitative accuracy in the case of homogeneous objects as well as enhanced image quality for the imaging of complex biological samples are demonstrated through experiments at two synchrotron radiation facilities. The large range of applicability, the robustness against noise and the need for only one input image suggest a high potential for investigations in various research subjects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...