1.
Lab Chip ; 20(16): 2911-2926, 2020 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-32662810

RESUMO

HepaChip microplate (HepaChip-MP) is a microfluidic platform comprised of 24 independent culture chambers with continuous, unidirectional perfusion. In the HepaChip-MP, an automated dielectrophoresis process selectively assembles viable cells into elongated micro tissues. Freshly isolated primary human hepatocytes (PHH) and primary human liver endothelial cells (HuLEC) were successfully assembled as cocultures aiming to mimic the liver sinusoid. Minimal quantities of primary human cells are required to establish micro tissues in the HepaChip-MP. Metabolic function including induction of CYP enzymes in PHH was successfully measured demonstrating a high degree of metabolic activity of cells in HepaChip-MP cultures and sufficient sensitivity of LC-MS analysis even for the relatively small number of cells per chamber. Further, parallelization realized in HepaChip-MP enabled the acquisition of dose-response toxicity data of diclofenac with a single device. Several unique technical features should enable a widespread application of this in vitro model. We have demonstrated fully automated preparation of cell cultures in HepaChip-MP using a pipetting robot. The tubeless unidirectional perfusion system based on gravity-driven flow can be operated within a standard incubator system. Overall, the system readily integrates in workflows common in cell culture labs. Further research will be directed towards optimization of media composition to further extend culture lifetime and study oxygen gradients and their effect on zonation within the sinusoid-like microorgans. In summary, we have established a novel parallelized and scalable microfluidic in vitro liver model showing hepatocyte function and anticipate future in-depth studies of liver biology and applications in pre-clinical drug development.


Assuntos
Células Endoteliais , Fígado , Técnicas de Cultura de Células , Técnicas de Cocultura , Hepatócitos , Humanos
2.
Biomicrofluidics ; 9(3): 034111, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26180568

RESUMO

Aptamers are promising cell targeting ligands for several applications such as for the diagnosis, therapy, and drug delivery. Especially, in the field of regenerative medicine, stem cell specific aptamers have an enormous potential. Using the combinatorial chemistry process SELEX (Systematic Evolution of Ligands by Exponential enrichment), aptamers are selected from a huge oligonucleotide library consisting of approximately 10(15) different oligonucleotides. Here, we developed a microfluidic chip system that can be used for the selection of cell specific aptamers. The major drawbacks of common cell-SELEX methods are the inefficient elimination of the unspecifically bound oligonucleotides from the cell surface and the unspecific binding/uptake of oligonucleotides by dead cells. To overcome these obstacles, a microfluidic device, which enables the simultaneous performance of dielectrophoresis and electrophoresis in the same device, was designed. Using this system, viable cells can be selectively assembled by dielectrophoresis between the electrodes and then incubated with the oligonucleotides. To reduce the rate of unspecifically bound sequences, electrophoretic fields can be applied in order to draw loosely bound oligonucleotides away from the cells. Furthermore, by increasing the flow rate in the chip during the iterative rounds of SELEX, the selection pressure can be improved and aptamers with higher affinities and specificities can be obtained. This new microfluidic device has a tremendous capability to improve the cell-SELEX procedure and to select highly specific aptamers.

3.
Biomed Microdevices ; 13(3): 493-501, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21347825

RESUMO

In order to study possible toxic side effects of potential drug compounds in vitro a reliable test system is needed. Predicting liver toxicity presents a major challenge of particular importance as liver cells grown in a cell culture suffer from a rapid loss of their liver specific functions. Therefore we are developing a new microfluidic test system for liver toxicity. This test system is based on an organ-like liver 3D co-culture of hepatocytes and endothelial cells. We devised a microfluidic chip featuring cell culture chambers with integrated electrodes for the assembly of liver sinusoids by dielectrophoresis. Fluid channels enable an organ-like perfusion with culture media and test compounds. Different chamber designs were studied and optimized with regard to dielectrophoretic force distribution, hydrodynamic flow profile, and cell trapping rate using numeric simulations. Based on simulation results a microchip was injection-moulded from COP. This chip allowed the assembly of viable hepatocytes and endothelial cells in a sinusoid-like fashion.


Assuntos
Órgãos Artificiais , Eletroforese/instrumentação , Fígado/citologia , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Cultura de Células , Sobrevivência Celular , Impedância Elétrica , Células Endoteliais/citologia , Desenho de Equipamento , Proteínas da Matriz Extracelular/metabolismo , Hepatócitos/citologia , Humanos , Modelos Teóricos , Perfusão
4.
Electrophoresis ; 32(17): 2366-76, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23361923

RESUMO

This research is part of a program aiming at the development of a fluidic microsystem for in vitro drug testing. For this purpose, primary cells need to be assembled to form cellular aggregates in such a way as to resemble the basic functional units of organs. By providing for in vivo-like cellular contacts, proper extracellular matrix interaction and medium perfusion it is expected that cells will retain their phenotype over prolonged periods of time. In this way, in vitro test systems exhibiting in vivo type predictivity in drug testing are envisioned. Towards this goal a 3-D microstructure micro-milled in a cyclic olefin copolymer (COC) was designed in such a way as to assemble liver cells via insulator-based dielectrophoresis (iDEP) in a sinusoid-type fashion. First, numeric modelling and simulation of dielectrophoretic and hydrodynamic forces acting on cells in this microsystem was performed. In particular, the problem of the discontinuity of the electric field at the interface between the fluid media in the system and the polymer materials it consists of was addressed. It was shown that in certain cases, the material of the microsystem may be neglected altogether without introducing considerable error into the numerical solution. This simplification enabled the simulation of 3-D cell trajectories in complex chip geometries. Secondly, the assembly of HepG2 cells by insulator-based dielectrophoresis in this device is demonstrated. Finally, theoretical results were validated by recording 3-D cell trajectories and the Clausius-Mossotti factor of liver cells was determined by combining results obtained from both simulation and experiment.


Assuntos
Técnicas Citológicas/instrumentação , Técnicas Citológicas/métodos , Eletroforese/instrumentação , Eletroforese/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Modelos Teóricos , Agregação Celular , Simulação por Computador , Cicloparafinas/química , Desenho de Equipamento , Células Hep G2 , Células Endoteliais da Veia Umbilical Humana , Humanos , Hidrodinâmica
5.
Front Neuroeng ; 3: 113, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21151808

RESUMO

Chemical stimulation of cells is inherently cell type selective in contrast to electro-stimulation. The availability of a system for localized application of minute amounts of chemical stimulants could be useful for dose related response studies to test new compounds. It could also bring forward the development of a novel type of neuroprostheses. In an experimental setup microdroplets of an acetylcholine solution were ejected from a fluidic microsystem and applied to the bottom of a nanoporous membrane. The solution traveled through the pores to the top of the membrane on which TE671 cells were cultivated. Calcium imaging was used to visualize cellular response with temporal and spatial resolution. Experimental demonstration of chemical stimulation for both threshold gated stimulation as well as accumulated dose-response was achieved by either employing acetylcholine as chemical stimulant or applying calcein uptake, respectively. Numerical modeling and simulation of transport mechanisms involved were employed to gain a theoretical understanding of the influence of pore size, concentration of stimulant and droplet volume on the spatial-temporal distribution of stimulant and on the cellular response. Diffusion, pressure driven flow and evaporation effects were taken into account. Fast stimulation kinetic is achieved with pores of 0.82 µm diameter, whereas sustained substance delivery is obtained with nanoporous membranes. In all cases threshold concentrations ranging from 0.01 to 0.015 µM acetylcholine independent of pore size were determined.

6.
Electrophoresis ; 31(15): 2655-63, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20665923

RESUMO

We have developed a microfluidic system--microPrep--for subcellular fractionation of cell homogenates based on dielectrophoretic sorting. Separation of mitochondria isolated from a human lymphoblastoid cell line was monitored by fluorescence microscopy and further characterized by western blot analysis. Robust high throughput and continuous long-term operation for up to 60 h of the microPrep chip system with complex biological samples became feasible as a result of a comprehensive set of technical measures: (i) coating of the inner surfaces of the chip with BSA, (ii) application of mechanical actuators to induce periodic flow patterns, (iii) efficient cooling of the device to ensure integrity of organelle, (iv) a wide channel to provide for high fluidic throughput, and (v) integration of a serial arrangement of 10 dielectrophoretic deflector units to enable separation of samples with a high particle load without clogging. Hence, microPrep yields tens of micrograms of enriched and purified mitochondria within hours. Western blots of mitochondria fractions showed that contaminating endoplasmatic reticulum was reduced by a factor 6 when compared with samples prepared by state of the art centrifugation.


Assuntos
Fracionamento Celular/métodos , Eletroforese em Microchip/métodos , Mitocôndrias/química , Proteínas Mitocondriais/análise , Fracionamento Celular/instrumentação , Linhagem Celular Tumoral , Eletroforese em Microchip/instrumentação , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS