Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
1.
Eur Radiol ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38189979

RESUMO

OBJECTIVES: To investigate intra-patient variability of iodine concentration (IC) between three different dual-energy CT (DECT) platforms and to test different normalization approaches. METHODS: Forty-four patients who underwent portal venous phase abdominal DECT on a dual-source (dsDECT), a rapid kVp switching (rsDECT), and a dual-layer detector platform (dlDECT) during cancer follow-up were retrospectively included. IC in the liver, pancreas, and kidneys and different normalized ICs (NICPV:portal vein; NICAA:abdominal aorta; NICALL:overall iodine load) were compared between the three DECT scanners for each patient. A longitudinal mixed effects analysis was conducted to elucidate the effect of the scanner type, scan order, inter-scan time, and contrast media amount on normalized iodine concentration. RESULTS: Variability of IC was highest in the liver (dsDECT vs. dlDECT 28.96 (14.28-46.87) %, dsDECT vs. rsDECT 29.08 (16.59-62.55) %, rsDECT vs. dlDECT 22.85 (7.52-33.49) %), and lowest in the kidneys (dsDECT vs. dlDECT 15.76 (7.03-26.1) %, dsDECT vs. rsDECT 15.67 (8.86-25.56) %, rsDECT vs. dlDECT 10.92 (4.92-22.79) %). NICALL yielded the best reduction of IC variability throughout all tissues and inter-scanner comparisons, yet did not reduce the variability between dsDECT vs. dlDECT and rsDECT, respectively, in the liver. The scanner type remained a significant determinant for NICALL in the pancreas and the liver (F-values, 12.26 and 23.78; both, p < 0.0001). CONCLUSIONS: We found tissue-specific intra-patient variability of IC across different DECT scanner types. Normalization mitigated variability by reducing physiological fluctuations in iodine distribution. After normalization, the scanner type still had a significant effect on iodine variability in the pancreas and liver. CLINICAL RELEVANCE STATEMENT: Differences in iodine quantification between dual-energy CT scanners can partly be mitigated by normalization, yet remain relevant for specific tissues and inter-scanner comparisons, which should be taken into account at clinical routine imaging. KEY POINTS: • Iodine concentration showed the least variability between scanner types in the kidneys (range 10.92-15.76%) and highest variability in the liver (range 22.85-29.08%). • Normalizing tissue-specific iodine concentrations against the overall iodine load yielded the greatest reduction of variability between scanner types for 2/3 inter-scanner comparisons in the liver and for all (3/3) inter-scanner comparisons in the kidneys and pancreas, respectively. • However, even after normalization, the dual-energy CT scanner type was found to be the factor significantly influencing variability of iodine concentration in the liver and pancreas.

2.
Abdom Radiol (NY) ; 48(6): 2167-2195, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36933024

RESUMO

Infarcts and ischemia of abdominal organs may present with acute abdominal pain, and early diagnosis is crucial to prevent morbidity and mortality. Unfortunately, some of these patients present in poor clinical conditions to the emergency department, and imaging specialists are crucial for optimal outcomes. Although the radiological diagnosis of abdominal infarcts is often straightforward, it is vital to use the appropriate imaging modalities and correct imaging techniques for their detection. Additionally, some non-infarct-related abdominal pathologies may mimic infarcts, cause diagnostic confusion, and result in delayed diagnosis or misdiagnosis. In this article, we aimed to outline the general imaging approach, present cross-sectional imaging findings of infarcts and ischemia in several abdominal organs, including but not limited to, liver, spleen, kidneys, adrenals, omentum, and intestinal segments with relevant vascular anatomy, discuss possible differential diagnoses and emphasize important clinical/radiological clues that may assist radiologists in the diagnostic process.


Assuntos
Abdome Agudo , Abdome , Humanos , Abdome Agudo/diagnóstico por imagem , Abdome Agudo/etiologia , Diagnóstico por Imagem/efeitos adversos , Dor Abdominal , Infarto/diagnóstico por imagem , Isquemia/diagnóstico por imagem , Isquemia/complicações
3.
Ann Surg ; 277(4): e893-e899, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35185121

RESUMO

OBJECTIVE: To compare positron emission tomography (PET)/magnetic resonance imaging (MRI) to the standard of care imaging (SCI) for the diagnosis of peritoneal carcinomatosis (PC) in primary abdominopelvic malignancies. SUMMARY BACKGROUND DATA: Identifying PC impacts prognosis and management of multiple cancer types. METHODS: Adult subjects were prospectively and consecutively enrolled from April 2019 to January 2021. Inclusion criteria were: 1) acquisition of whole-body contrast-enhanced (CE) 18F-fluorodeoxyglucose PET/MRI, 2) pathologically confirmed primary abdominopelvic malignancies. Exclusion criteria were: 1) greater than 4 weeks interval between SCI and PET/MRI, 2) unavailable follow-up. SCI consisted of whole-body CE PET/computed tomography (CT) with diagnostic quality CT, and/or CE-CT of the abdomen and pelvis, and/or CE-MRI of the abdomen±pelvis. If available, pathology or surgical findings served as the reference standard, otherwise, imaging followup was used. When SCI and PET/MRI results disagreed, medical records were checked for management changes. Follow-up data were collected until August 2021. RESULTS: One hundred sixty-four subjects were included, 85 (52%) were female, and the median age was 60 years (interquartile range 50-69). At a subject level, PET/MRI had higher sensitivity (0.97, 95% CI 0.86-1.00) than SCI (0.54, 95% CI 0.37-0.71), P < 0.001, without a difference in specificity, of 0.95 (95% CI 0.90-0.98) for PET/MRI and 0.98 (95% CI 0.93-1.00) for SCI, P » 0.250. PET/MRI and SCI results disagreed in 19 cases. In 5/19 (26%) of the discordant cases, PET/MRI findings consistent with PC missed on SCI led to management changes. CONCLUSION: PET/MRI improves detection of PC compared with SCI which frequently changes management.


Assuntos
Neoplasias Peritoneais , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Neoplasias Peritoneais/diagnóstico por imagem , Padrão de Cuidado , Fluordesoxiglucose F18 , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
4.
Eur Radiol ; 33(2): 1318-1328, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36074261

RESUMO

OBJECTIVES: To assess the impact of dual-energy CT (DECT) utilization in practice by measuring the readers' confidence, the need for additional image requests, and diagnostic performance in renal lesion assessment, compared to single-energy CT (SECT) using contrast-enhanced MRI to establish the reference standard. MATERIALS AND METHODS: Sixty-nine patients (M/F = 47/22) who underwent a dual-phase renal SECT (n = 34) or DECT (n = 35) and had a contrast-enhanced MRI within 180 days were retrospectively collected. Three radiologists assessed images on different sessions (SECT, DECT, and MRI) for (1) likely diagnosis (enhancing/non-enhancing); (2) diagnostic confidence (5-point Likert scale); (3) need for additional imaging test (yes/no); and (4) need for follow-up imaging (yes/no). Diagnostic accuracy was compared using AUC; p value < 0.05 was considered significant. RESULTS: One hundred fifty-six lesions consisting of 18% enhancing (n = 28/156, mean size: 30.37 mm, range: 9.9-94 mm) and 82% non-enhancing (n = 128/156, mean size: 23.91 mm, range: 5.0-94.2 mm) were included. The confidence level was significantly lower for SECT than their MRI (4.50 vs. 4.80, p value < 0.05) but not significantly different for DECT and the corresponding MRI (4.78 vs. 4.78, p > 0.05). There were significantly more requests for additional imaging in the SECT session than the corresponding MRI (20% vs. 4%), which was not significantly different between DECT and their MRI counterpart session (5.7% vs. 4.9%). Inter-reader agreement was almost perfect for DECT and MRI (kappa: 0.8-1) and substantial in SECT sessions (kappa: 0.6-0.8) with comparable diagnostic accuracy between SECT, DECT, and MRI (p value > 0.05). CONCLUSION: Single-phase DECT allows confident and reproducible characterization of renal masses with fewer recommendation for additional and follow-up imaging tests than dual-phase SECT and a performance similar to MRI. KEY POINTS: • DECT utilization leads to similar additional image requests to MRI (5.7% vs. 4.9%, p value > 0.05), whereas single-energy CT utilization leads to significantly higher image requests (20% vs. 4%, p value < 0.05). • DECT and MRI utilization bring highly reproducible results with almost perfect inter-reader agreement (kappa: 0.8-1), better than the inter-reader agreement in SECT utilization (kappa: 0.6-0.8). • Readers' confidence was not significantly altered between DECT and their MRI readout session (p value > 0.05). In contrast, confidence in the diagnosis was significantly lower in the SECT session than their MRI readout (p value < 0.05).


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Doses de Radiação , Imageamento por Ressonância Magnética
6.
Invest Radiol ; 57(1): 52-61, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34162795

RESUMO

MATERIALS AND METHODS: Forty-four patients with clinical contrast-enhanced abdominal examinations on each of the 3 DECT scanner types and a phantom scanned with the same protocols were included in this retrospective study. Qualitative and quantitative assessment was performed on VUE images. Quantitative evaluation included measurement of attenuation and image noise for various tissues and the phantom. Virtual unenhanced image attenuation and noise were compared between scanner types, and intrapatient interscanner reproducibility of virtual unenhanced image attenuation was calculated as the percentage of measurement pairs with an interscanner difference ≤ 10 HU. Image quality, noise, sharpness, and iodine elimination were assessed qualitatively by 2 radiologists. RESULTS: Significant interscanner differences in VUE attenuation and noise were found in all tissues. dlDECT and rsDECT showed significantly higher VUE attenuation than dsDECT in the aorta, portal vein, and kidneys (P < 0.05). Conversely, VUE attenuation in dsDECT was significantly higher than in dlDECT/rsDECT for subcutaneous and retroperitoneal fat (both P < 0.05). A total of 91.9% (385/419) of measurements were reproducible between rsDECT and dlDECT, 70.9% (297/419) between dsDECT and rsDECT, and 66.8% (280/419) between dsDECT and dlDECT. Virtual unenhanced image attenuation in the contrast media-filled phantom cavity was 12.7 ± 4.7 HU in dlDECT, -5.3 ± 4.2 HU in rsDECT, and -4.0 ± 10.7 HU in dsDECT with significant differences between dlDECT and rsDECT/dsDECT, respectively (P < 0.05), between which attenuation was comparable in the unenhanced extraluminal phantom component (P = 0.11-0.62). Qualitatively, dsDECT yielded best iodine elimination, whereas sharpness, image noise, and overall image quality were rated higher in dlDECT and rsDECT. CONCLUSIONS: There are significant interscanner differences in the attenuation measurements and qualitative assessment of VUE images, which should be acknowledged when using these images in patients that are being scanned on different DECT scanner types during imaging follow-up.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Meios de Contraste , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
Insights Imaging ; 12(1): 95, 2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34232414

RESUMO

Tumors of the genital system are common and imaging is of crucial importance for their detection and diagnosis. Several non-neoplastic diseases may mimic these tumors and differential diagnosis may be difficult in certain cases. Misdiagnosing non-neoplastic diseases as tumor may prompt unnecessary medical treatment or surgical interventions. In this article, we aimed to present the imaging characteristics of non-neoplastic diseases of the male and female genital systems that may mimic neoplastic processes. Increasing awareness of the imaging specialists to these entities may have a severe positive impact on the management of these patients.

8.
Abdom Radiol (NY) ; 46(10): 4828-4852, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34047800

RESUMO

The spleen plays an important role in the immunological homeostasis of the body. Several neoplastic and non-neoplastic diseases may affect this organ, and imaging is of fundamental importance for diagnosis. Infectious diseases of the spleen can be encountered in daily radiology practice, and differential diagnosis may sometimes be challenging. Infectious involvement of the spleen can be primary or secondary to a different source outside the spleen. Despite the fact that different infectious diseases may cause similar imaging findings, we believe that differential diagnosis between different causes may also be possible in certain patients with imaging. Early diagnosis may potentially enhance patients' treatment and outcome. In this review, we aimed to increase imaging specialists' awareness of splenic infections by describing the multimodality imaging features of common and atypical infections of the spleen with their differential diagnoses.


Assuntos
Esplenopatias , Diagnóstico Diferencial , Humanos , Imagem Multimodal , Radiografia , Esplenopatias/diagnóstico por imagem
9.
Eur Radiol ; 31(9): 6898-6908, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33744992

RESUMO

OBJECTIVE: To assess the feasibility of a proposed pancreatic protocol CT generated from portal-venous phase (PVP) dual-energy CT (DECT) acquisition and its impact on image quality, lesion conspicuity, and arterial visualization/involvement. METHODS: We included 111 patients (mean age, 66.8 years) who underwent pancreatic protocol DECT (pancreatic phase, PP, and PVP). The original DECT acquisition was used to create two data sets-standard protocol (50 keV PP/65 keV PVP) and proposed protocol (40 keV/65 keV PVP). Three reviewers evaluated the two data sets for image quality, lesion conspicuity, and arterial visualization/involvement using a 5-point scale. The signal-to-noise ratio (SNR) of pancreas and lesion-to-pancreas contrast-to-noise ratio (CNR) was calculated. Qualitative scores, quantitative parameters, and dose-length product (DLP) were compared between standard and proposed protocols. RESULTS: The image quality, SNR of pancreas, and lesion-to-pancreas CNR of the standard and proposed protocol were comparable (p = 0.11-1.00). Lesion conspicuity was comparable between the standard and proposed protocols for pancreatic ductal adenocarcinoma (p = 0.55) and pancreatic cysts (p = 0.28). The visualization of larger arteries and arterial involvement were comparable between the two protocols (p = 0.056-1.00) while the scores were higher for smaller vessels in the standard protocol (p < 0.0001-0.0015). DLP of the proposed protocol (670.4 mGy·cm) showed a projected 42% reduction than the standard protocol (1145.9 mGy·cm) (p < 0.0001). CONCLUSION: Pancreatic protocol CT generated from a single PVP DECT acquisition is feasible and could potentially be an alternative to the standard pancreatic protocol with PP and PVP. KEY POINTS: • The lesion conspicuity for focal pancreatic lesions was comparable between the proposed protocol and standard dual-phase pancreatic protocol CT. • Qualitative and quantitative image assessments were almost comparable between two protocols. • The radiation dose of a proposed protocol showed a projected 42% reduction from the conventional protocol.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Idoso , Carcinoma Ductal Pancreático/diagnóstico por imagem , Meios de Contraste , Estudos de Viabilidade , Humanos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
10.
Radiology ; 297(1): E207-E215, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32391742

RESUMO

Background Angiotensin-converting enzyme 2, a target of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), demonstrates its highest surface expression in the lung, small bowel, and vasculature, suggesting abdominal viscera may be susceptible to injury. Purpose To report abdominal imaging findings in patients with coronavirus disease 2019. Materials and Methods In this retrospective cross-sectional study, patients consecutively admitted to a single quaternary care center from March 27 to April 10, 2020, who tested positive for SARS-CoV-2 were included. Abdominal imaging studies performed in these patients were reviewed, and salient findings were recorded. Medical records were reviewed for clinical data. Univariable analysis and logistic regression were performed. Results A total of 412 patients (average age, 57 years; range, 18 to >90 years; 241 men, 171 women) were evaluated. A total of 224 abdominal imaging studies were performed (radiography, n = 137; US, n = 44; CT, n = 42; MRI, n = 1) in 134 patients (33%). Abdominal imaging was associated with age (odds ratio [OR], 1.03 per year of increase; P = .001) and intensive care unit (ICU) admission (OR, 17.3; P < .001). Bowel-wall abnormalities were seen on 31% of CT images (13 of 42) and were associated with ICU admission (OR, 15.5; P = .01). Bowel findings included pneumatosis or portal venous gas, seen on 20% of CT images obtained in patients in the ICU (four of 20). Surgical correlation (n = 4) revealed unusual yellow discoloration of the bowel (n = 3) and bowel infarction (n = 2). Pathologic findings revealed ischemic enteritis with patchy necrosis and fibrin thrombi in arterioles (n = 2). Right upper quadrant US examinations were mostly performed because of liver laboratory findings (87%, 32 of 37), and 54% (20 of 37) revealed a dilated sludge-filled gallbladder, suggestive of bile stasis. Patients with a cholecystostomy tube placed (n = 4) had negative bacterial cultures. Conclusion Bowel abnormalities and gallbladder bile stasis were common findings on abdominal images of patients with coronavirus disease 2019. Patients who underwent laparotomy often had ischemia, possibly due to small-vessel thrombosis. © RSNA, 2020.


Assuntos
Abdome/diagnóstico por imagem , Infecções por Coronavirus/diagnóstico por imagem , Gastroenteropatias/diagnóstico por imagem , Gastroenteropatias/virologia , Pneumonia Viral/diagnóstico por imagem , Abdome/patologia , Abdome/cirurgia , Abdome/virologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/complicações , Infecções por Coronavirus/patologia , Feminino , Gastroenteropatias/patologia , Gastroenteropatias/cirurgia , Humanos , Laparotomia , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/complicações , Pneumonia Viral/patologia , Estudos Retrospectivos , SARS-CoV-2 , Adulto Jovem
11.
Insights Imaging ; 11(1): 21, 2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-32040641

RESUMO

Despite the success of cross-sectional imaging in evaluating hepatopancreatobiliary system malignancies, several non-malignant disease processes may closely mimic malignancy. Differentiating these benign diseases from malignancy may be difficult, or even impossible, even in the hands of experienced imagers. In this manuscript, we present benign mimics involving the hepatopancreatobiliary system and try to increase awareness of these potential pitfalls.

12.
Abdom Radiol (NY) ; 45(4): 1110-1121, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31570959

RESUMO

Neoplastic diseases affecting the urinary organs are common, and diagnosis by imaging is usually straightforward. However, infectious/inflammatory processes also commonly affect these organs and can be mistaken for a neoplasm. Familiarity with these potential mimickers and awareness of their imaging presentations are key for correct diagnosis. We present the imaging findings of non-neoplastic infectious/inflammatory diseases that can mimic a neoplastic process.


Assuntos
Inflamação/diagnóstico por imagem , Infecções Urinárias/diagnóstico por imagem , Doenças Urológicas/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Infecções Urinárias/microbiologia , Infecções Urinárias/parasitologia , Infecções Urinárias/terapia , Doenças Urológicas/terapia , Neoplasias Urológicas/diagnóstico por imagem
13.
Abdom Radiol (NY) ; 44(9): 2988-3005, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31209544

RESUMO

Unlike nodal lymphoma, primary lymphomas of the intraabdominal organs are uncommon neoplasms whose diagnosis may be challenging in certain clinical circumstances. Despite this difficulty for imaging diagnosis, there are several imaging features on ultrasonography, computed tomography, magnetic resonance imaging, and positron emission tomography that may suggest the correct diagnosis. The scope of this review is to describe and illustrate the imaging features of primary lymphoma of intraabdominal organs providing clues to the diagnosis, together with their pathological correlations.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Linfoma/diagnóstico por imagem , Abdome/diagnóstico por imagem , Trato Gastrointestinal/diagnóstico por imagem , Humanos
14.
Abdom Radiol (NY) ; 42(6): 1734-1743, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28197683

RESUMO

OBJECTIVE: To evaluate whether the Aorta-Lesion-Attenuation-Difference on contrast-enhanced CT can aid in the differentiation of malignant and benign oncocytic renal neoplasms. MATERIALS AND METHODS: Two independent cohorts-an initial (biopsy) dataset and a validation (surgical) dataset-with oncocytomas and chromophobe renal cell carcinomas (chRCC) were included in this IRB-approved retrospective study. A region of interest was placed on the renal mass and abdominal aorta on the same CT image slice to calculate an Aorta-Lesion-Attenuation-Difference (ALAD). ROC curves were plotted for different enhancement phases, and diagnostic performance of ALAD for differentiating chRCC from oncocytomas was calculated. RESULTS: Seventy-nine renal masses (56 oncocytomas, 23 chRCC) were analyzed in the initial (biopsy) dataset. Thirty-six renal masses (16 oncocytomas, 20 chRCC) were reviewed in the validation (surgical) cohort. ALAD showed a statistically significant difference between oncocytomas and chromophobes during the nephrographic phase (p < 0.001), early excretory phase (p < 0.001), and excretory phase (p = 0.029). The area under the ROC curve for the nephrographic phase was 1.00 (95% CI: 1.00-1.00) for the biopsy dataset and showed the narrowest confidence interval. At a threshold value of 25.5 HU, sensitivity was 100 (82.2%-100%) and specificity was 81.5 (61.9%-93.7%). When tested on the validation dataset on measurements made by an independent reader, the AUROC was 0.93 (95% CI: 0.84-1.00) with a sensitivity of 100 (80.0%-100%) and a specificity of 87.5 (60.4%-97.8%). CONCLUSIONS: Nephrographic phase ALAD has potential to differentiate benign and malignant oncocytic renal neoplasms on contrast-enhanced CT if histologic evaluation on biopsy is indeterminate.


Assuntos
Adenoma Oxífilo/diagnóstico por imagem , Adenoma Oxífilo/patologia , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Biópsia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
15.
Abdom Radiol (NY) ; 42(5): 1298-1309, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27933477

RESUMO

OBJECTIVES: To determine to what extent low-energy CT imaging affects attenuation of gastrointestinal tract (GIT) opacified with positive oral contrast media (OCM). Second, to establish optimal OCM concentrations for low-energy diagnostic CT exams. METHODS: One hundred patients (38 men and 62 women; age 62 ± 11 years; BMI 26 ± 5) with positive OCM-enhanced 120-kVp single-energy CT (SECT), and follow-up 100-kVp acquisitions (group A; n = 50), or 40-70-keV reconstructions from rapid kV switching-single-source dual-energy CT (ssDECT) (group B; n = 50) were included. Luminal attenuation from different GIT segments was compared between exams. Standard dose of three OCM and diluted solutions (75%, 50%, and 25% concentrations) were introduced serially in a gastrointestinal phantom and scanned using SECT (120, 100, and 80 kVp) and DECT (80/140 kVp) acquisitions on a ssDECT scanner. Luminal attenuation was obtained on SECT and DECT images (40-70 keV), and compared to 120-kVp scans with standard OCM concentrations. RESULTS: Luminal attenuation was higher on 100-kVp (328 HU) and on 40-60-keV images (410-924 HU) in comparison to 120-kVp scans (298 HU) in groups A and B (p < 0.05). Phantom: There was an inverse correlation between luminal attenuation and X-ray energy, increasing up to 527 HU on low-kVp and 999 HU on low-keV images (p < 0.05). 25% and 50% diluted OCM solutions provided similar or higher attenuation than 120 kVp, at low kVp and keV, respectively. CONCLUSIONS: Low-energy CT imaging increases the attenuation of GIT opacified with positive OCM, permitting reduction of 25%-75% OCM concentration.


Assuntos
Sulfato de Bário/administração & dosagem , Meios de Contraste/administração & dosagem , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
16.
Ultrasound Q ; 33(1): 23-27, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27575843

RESUMO

This study aimed to determine whether active ultrasound surveillance may obviate the need for surgical resection in selected patients with small testicular lesions (STLs). A retrospective 11-year review was conducted of adults who were diagnosed with an STL on scrotal ultrasonography and who either had orchiectomy or sonographic follow-up during a period of at least 3 months. A total of 101 subjects were enrolled. Ultrasound findings, clinical features, histopathology/follow-up imaging were recorded. Logistic regression analysis was performed to select independent risk factors for the diagnosis of malignancy. Seventeen (16.8%) subjects underwent immediate surgery, 8 (7.9%) of 101 underwent surgery after ultrasound follow-up, and 76 (75.3%) of 101 were followed with ultrasound only. The follow-up period ranged from 1 to 7 months in the 8 patients who ultimately underwent surgery after ultrasound follow-up and from 6 to 84 months in the 76 patients followed up with ultrasound only. All 15 malignant cases underwent immediate surgery without follow-up sonography. The frequency of lesions, either benign at surgery or stable on ultrasound, was 85.1% (86 of 101; 95% confidence interval, 77%-91%). Logistic regression analysis showed that lesion size was the only independent risk factor for malignancy in hypoechoic STLs (P < 0.05). Most of the STLs were stable on serial sonograms and likely benign. Active ultrasound surveillance may be an appropriate management strategy in patients with STLs.


Assuntos
Neoplasias Testiculares/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Orquiectomia/estatística & dados numéricos , Estudos Retrospectivos , Neoplasias Testiculares/cirurgia , Testículo/diagnóstico por imagem , Testículo/cirurgia , Adulto Jovem
17.
Abdom Radiol (NY) ; 42(4): 1096-1112, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27866240

RESUMO

A wide spectrum of extranodal lymphomas in the abdomen and pelvis is commonly encountered by imaging. Diagnosing these lesions generally requires a multimodality approach. This review highlights imaging appearances of extranodal lymphomas in the abdomen and pelvis with emphasis on computed tomography, magnetic resonance imaging, and positron emission tomography-computed tomography along with the relevant differential diagnosis.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Imagem Multimodal , Neoplasias Pélvicas/diagnóstico por imagem , Diagnóstico Diferencial , Humanos
18.
Abdom Radiol (NY) ; 42(4): 1141-1151, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27891551

RESUMO

PURPOSE: Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. METHODS: Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. RESULTS: The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). CONCLUSION: PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Compostos Radiofarmacêuticos
19.
Abdom Radiol (NY) ; 41(12): 2466-2475, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27660280

RESUMO

PURPOSE: The purpose of the study was to assess the diagnostic performance of qualitative and quantitative diffusion-weighted imaging (DWI) in differentiating benign from malignant ovarian and uterine masses. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant retrospective study, with waiver of informed consent. DWI MRIs of 222 women acquired over 1.5 years were evaluated. Reference standard was pathology or follow-up imaging. For qualitative assessment, two radiologists independently reviewed DWI and apparent diffusion coefficient (ADC) images for diffusion restriction. Differences were resolved by consensus. For quantitative assessment, a single reader measured ADC values. Readers were blinded to the reference standard. RESULTS: 222 lesions, 121 ovarian (99 benign and 22 malignant) and 101 uterine (54 benign and 47 malignant), were included. Final diagnosis was established with pathology in 129 (58%) or with imaging follow-up in 93 (42%). Mean (range) follow-up interval was 27 (13-48) months. Qualitative assessment yielded sensitivity (ratio, 95% CI), specificity, PPV and NPV of 100% (22/22, 85-100), 68% (68/99, 58-76), 41% (22/54, 27-54), and 100% (68/68, 94-100) for ovarian and 94% (44/47, 83-98), 91% (49/54, 80-96), 90% (44/49, 78-95) and 94% (49/52, 84-98) for uterine malignancies. ADC (mean ± SD) between benign ovarian [(1.11 ± 0.76) × 10-3 mm2/s] vs. malignant [(0.71 ± 0.26) × 10-3 mm2/s] lesions was significantly different (p < 0.001). ADC cutoff value of 1.55 × 10-3 mm2/s for ovarian lesions resulted in 99.9% confidence for the absence of malignancy. ADC (mean ± SD) of benign uterine [(0.64 ± 0.38) × 10-3 mm2/s] vs. malignant [(0.68 ± 0.19) × 10-3 mm2/s] lesions was not significantly different (P < 0.54). CONCLUSION: Quantitative and qualitative DWI assessment can be used to confidently characterize a subset of ovarian lesions as benign. With uterine lesions, although DWI is useful in differentiating benign from malignant lesions, the technique does not allow for definitive quantitative characterization.


Assuntos
Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Pessoa de Meia-Idade , Neoplasias Ovarianas/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Neoplasias Uterinas/patologia
20.
Radiographics ; 36(4): 1087-105, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27399237

RESUMO

Dual-energy (DE) computed tomography (CT) offers the opportunity to generate material-specific images on the basis of the atomic number Z and the unique mass attenuation coefficient of a particular material at different x-ray energies. Material-specific images provide qualitative and quantitative information about tissue composition and contrast media distribution. The most significant contribution of DE CT-based material characterization comes from the capability to assess iodine distribution through the creation of an image that exclusively shows iodine. These iodine-specific images increase tissue contrast and amplify subtle differences in attenuation between normal and abnormal tissues, improving lesion detection and characterization in the abdomen. In addition, DE CT enables computational removal of iodine influence from a CT image, generating virtual noncontrast images. Several additional materials, including calcium, fat, and uric acid, can be separated, permitting imaging assessment of metabolic imbalances, elemental deficiencies, and abnormal deposition of materials within tissues. The ability to obtain material-specific images from a single, contrast-enhanced CT acquisition can complement the anatomic knowledge with functional information, and may be used to reduce the radiation dose by decreasing the number of phases in a multiphasic CT examination. DE CT also enables generation of energy-specific and virtual monochromatic images. Clinical applications of DE CT leverage both material-specific images and virtual monochromatic images to expand the current role of CT and overcome several limitations of single-energy CT. (©)RSNA, 2016.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Meios de Contraste , Humanos , Doses de Radiação , Sensibilidade e Especificidade , Técnica de Subtração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...