Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Biomimetics (Basel) ; 9(4)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38667205

RESUMO

Solvent evaporation within an adhesive layer is a crucial step during a bonding process. The aim of this current research was to test whether the use of different air temperatures (20 °C, 40 °C, and 60 °C) for solvent evaporation improves the performance of four adhesive systems to dentin. Sixty non-carious human molar teeth were randomly prepared for micro-tensile bond strength (µTBS) tests. Four different adhesive systems, Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE), were applied following the manufacturer's instructions. Three groups based on the air-drying temperature were used: solvent evaporation was performed with either of warm (40 °C), (60 °C), and cold air as control group (20 °C) for 10 s at a distance of 5 cm. In all bonded surfaces, three resin composite (Reflectys, Itena Clinical, Paris, France) layers of 2 mm thickness were built up. The resin-dentin samples were kept in distilled water at 37 °C for 24 h and 6 months, respectively, before µTBS testing. Failure analysis, scanning electron microscopy of resin-dentin bonded interface, and solvent evaporation rate were tested as secondary variables. All analyses were conducted using a significance level of α = 0.05. Bond strength (BS) values were similar among all the adhesive systems used (p > 0.05). Also, the aging factor did not affect the BS (p > 0.05). Only the factor of temperature used for solvent evaporation resulted in a statistically significant effect (p < 0.05), with the temperature of 60 °C being the highest value (p < 0.05). A failure mode evaluation revealed mostly adhesive or mixed modes of failures in all the different temperatures of air used for the solvent evaporation of each adhesive system. The thickness of the adhesive layer and the creation of resin tags varied amongst the temperatures evaluated. For all adhesive systems tested, the use of 40 °C or 60 °C air for solvent evaporation led to an increased mass loss. Warmer temperatures for solvent evaporation contributed positively to bonding performance, enhancing both the quality of the adhesive layer and its interaction with the dentin tissue. Optimizing solvent evaporation with warmer air temperatures (40 °C and 60 °C) significantly improved µTBS, offering a practical means to enhance the quality and longevity of adhesive restorations in esthetic dentistry.

2.
Bioengineering (Basel) ; 11(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38534487

RESUMO

The present in vitro study focuses on the filling ability of three different bioceramic cements with or without the addition of a bioceramic sealer in an open apex model on the marginal apical adaptation, tubule infiltrations, and void distributions as well as the interface between the cement and the sealer materials. To this end, sixty mandibular premolars were used. MTA-Biorep (BR), Biodentine (BD), and Well-Root Putty (WR) were used to obturate the open apex model with or without the addition of a bioceramic sealer, namely TotalFill® BC sealer™ (TF). A digital optical microscope and scanning electron microscope (SEM) were used to investigate the cement-dentin interface, marginal apical adaptation, and the material infiltration into the dentinal tubules. Micro-computed X-ray tomography and digital optical microscopy were used to investigate the cement-sealer interface. The results were analyzed by using the Kruskal-Wallis test. No significant difference was found between the groups for the marginal apical adaptation quality (p > 0.05). Good adaptation of the dentin-cement interface was found for all tested groups and the sealer was placed between the cement material and dentinal walls. All the groups demonstrated some infiltrations into the dentinal tubules at the coronal part except for the BR group. A good internal interface was found between the cement and the sealer with the presence of voids at the external interface. A larger number of voids were found in the case of the BD-TF group compared to each of the other two groups (p < 0.05). Within the limitations of the present in vitro study, all the groups demonstrated good marginal apical adaptation. The use of a sealer in an open apex does not guarantee good filling and, in addition, creates voids at the external interfaces with the dental walls when the premixed sealer is used with powder-liquid cement systems. The use of a premixed bioceramic cement could offer fewer complications than when a powder-liquid cement system is used.

3.
Cells ; 13(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38334632

RESUMO

Melanoma frequently harbors genetic alterations in key molecules leading to the aberrant activation of PI3K and its downstream pathways. Although the role of PI3K/AKT/mTOR in melanoma progression and drug resistance is well documented, targeting the PI3K/AKT/mTOR pathway showed less efficiency in clinical trials than might have been expected, since the suppression of the PI3K/mTOR signaling pathway-induced feedback loops is mostly associated with the activation of compensatory pathways such as MAPK/MEK/ERK. Consequently, the development of intrinsic and acquired resistance can occur. As a solid tumor, melanoma is notorious for its heterogeneity. This can be expressed in the form of genetically divergent subpopulations including a small fraction of cancer stem-like cells (CSCs) and non-cancer stem cells (non-CSCs) that make the most of the tumor mass. Like other CSCs, melanoma stem-like cells (MSCs) are characterized by their unique cell surface proteins/stemness markers and aberrant signaling pathways. In addition to its function as a robust marker for stemness properties, CD133 is crucial for the maintenance of stemness properties and drug resistance. Herein, the role of CD133-dependent activation of PI3K/mTOR in the regulation of melanoma progression, drug resistance, and recurrence is reviewed.


Assuntos
Melanoma , Sirolimo , Humanos , Sirolimo/farmacologia , Fosfatidilinositol 3-Quinases/metabolismo , Fosfatidilinositol 3-Quinase/metabolismo , Proteínas Proto-Oncogênicas c-akt/metabolismo , Melanoma/patologia , Transdução de Sinais , Serina-Treonina Quinases TOR/metabolismo , Resistencia a Medicamentos Antineoplásicos
4.
Cancers (Basel) ; 16(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38275910

RESUMO

Melanoma is the third most common type of skin cancer, characterized by its heterogeneity and propensity to metastasize to distant organs. Melanoma is a heterogeneous tumor, composed of genetically divergent subpopulations, including a small fraction of melanoma-initiating cancer stem-like cells (CSCs) and many non-cancer stem cells (non-CSCs). CSCs are characterized by their unique surface proteins associated with aberrant signaling pathways with a causal or consequential relationship with tumor progression, drug resistance, and recurrence. Melanomas also harbor significant alterations in functional genes (BRAF, CDKN2A, NRAS, TP53, and NF1). Of these, the most common are the BRAF and NRAS oncogenes, with 50% of melanomas demonstrating the BRAF mutation (BRAFV600E). While the successful targeting of BRAFV600E does improve overall survival, the long-term efficacy of available therapeutic options is limited due to adverse side effects and reduced clinical efficacy. Additionally, drug resistance develops rapidly via mechanisms involving fast feedback re-activation of MAPK signaling pathways. This article updates information relevant to the mechanisms of melanoma progression and resistance and particularly the mechanistic role of CSCs in melanoma progression, drug resistance, and recurrence.

5.
Polymers (Basel) ; 15(19)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37835974

RESUMO

One of the major goals of adhesive dentistry is to improve the interaction of the already-existing adhesives with different substrates by using different application techniques. Thus, the objective of the present in vitro study was to assess the bond performance of four adhesive systems, Prime&Bond Universal (PBU), Clearfil SE Bond (CSE), OptiBond Universal (OBU), and OptiBond FL (OBFL), to dentin using various application modes: passive application (PA), active application (AA), Compo-Vibes modified application (CVM), and Compo-Vibes application (CV). Eighty extracted human molars were allocated into four groups based on the application modalities tested. The micro-tensile bond strength as well as fracture mode were tested in accordance with ISO/TS 11.405 after 24 h and 6 months of aging. Adhesive contact angle (CA) and scanning electron microscope analysis were also performed (n = 3). Statistical tests were performed with α = 0.05. After 24 h, a significant difference with a higher bond strength value was found for PBU in the AA modality and for CSE in the CVM modality (p < 0.05). However, no significant difference was shown between the techniques used among the other adhesives (OBFL and OBU). Moreover, at 24 h, only the PA demonstrated significant differences between the tested materials (p < 0.05). After 6 months, CSE, PBU, and OBU demonstrated significant differences between the techniques (p < 0.05), with a higher bond strength for CSE in AA and CVM modalities, for PBU in AA modality, and for OBU in AA and PA modalities. No significant differences were found between the techniques used among the OBFL (p > 0.05). In addition, only the CVM technique demonstrated significant differences between the tested materials after 6 months. CV and CVM showed a decreased value after aging for CSE and PBU, respectively. However, all the modalities decreased for OBU and OBFL after aging. All the adhesives showed marked resin infiltration into dentinal tubules in AA among all the modalities tested. Both universal adhesive systems (OBU and PBU) demonstrated statistically lower CA when compared to the other systems (CSE and OBFL) (p < 0.05) when applied in the PA mode. Concerning the AA mode, only CSE and OBFL were tested. The AA demonstrated lower CA values compared to the same adhesives in PA (p < 0.05). It could be concluded that the bond strength could be influenced by both materials and application techniques. It seems that the AA technique could be recommended as a gold standard for the application of an adhesive system to dentin. Plus, the CV and CVM modalities after 6 months of aging were considered stable for PBU and CSE, respectively. Consequently, the performance of these adhesive systems might vary when applied to other modalities. Future studies are needed to test this hypothesis.

6.
J Funct Biomater ; 14(10)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37888187

RESUMO

The goal of this article was to assess the effect of modified triple-layer application (MTLA) in conjunction with the active bonding technique on the bond strength of four adhesive systems to dentinal substrate. The adhesives tested were Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE). The adhesives were applied according to the following strategies: single active application (A) and triple adhesive layer application including Active-Passive-Passive (APP); AAP; and AAA. The micro-tensile bond strength test was evaluated following 24 h or 6 months of storage. The composite-dentin interface morphology was investigated using scanning electron microscopy. The data were statistically analyzed with a significance level of α = 0.05. At 24 h of aging, all of the factors tested were not significant (p > 0.05) for CSE. For OBFL, OBU, and PBU, statistically higher values were observed for the A technique (p < 0.05). Plus, there were no significant variances between the APP, AAP, and AAA techniques (p > 0.05) for OBFL and PBU. However, for OBU, there were no significant differences between the A and AAA techniques (p > 0.05). After 6 months of aging, the A technique showed statistically higher values when compared to the other techniques (p < 0.01), except for OBFL, where the A and AAA techniques showed promising outcomes. When comparing the bond strength values of 24 h and 6 months, only for PBU, all of the techniques used resulted in bond strength stability over time (p > 0.05). Thicker adhesive layers were observed when MTLA was applied. Only the OBFL adhesive showed the formation of resin tags in all of the modalities tested. The bonding performances of the different application techniques used were material-dependent.

7.
Bioengineering (Basel) ; 10(7)2023 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-37508845

RESUMO

A void-free obturation during root canal treatment on primary teeth is currently very difficult to attain. In this study, the pulpectomy filling abilities of Bio-C Pulpecto (Angelus, Basil, Londrina, Paraná, Brazil) and of zinc oxide eugenol, or "ZOE" (DenPro, Prevest, New York, NY, USA), were compared using several in vitro techniques. Therefore, 30 primary anterior teeth were used in the present in vitro study. Analysis of variance (ANOVA), including a multiple comparison procedure (Holm-Sidak method, Dunn's Method, or Tukey test), was used. On micro-CT, Bio-C Pulpecto exhibited higher void percentages than did ZOE (10.3 ± 3.8%, and 3.5 ± 1.3%), respectively (p < 0.05). With digital microscopy, higher total void percentages were found in the BC (13.2 ± 26.7%) group compared to the ZOE (2.7 ± 2.8%) group (p < 0.05). With the CLSM, mean tubular penetration depths were higher for Bio-C Pulpecto than for ZOE in all canal thirds (p < 0.05). SEM images demonstrated no tags into dentinal tubules in either group throughout the three thirds. Moreover, higher statistically significant flowability was found for Bio-C (2.657 ± 0.06 mm) compared to ZOE (1.8 ± 0.13 mm) (p < 0.05). The findings of this study indicate that neither ZOE nor Bio-C Pulpecto appears to meet the criteria for an ideal root canal filling paste for primary teeth. This study laid the groundwork for future research by determining how micro-CT, digital microscopy, SEM, and CLSM contribute to our understanding of the filling process of primary teeth. More thorough research on the mechanism of root canal obturation on primary teeth is required to achieve a long-term successful root canal therapy in young children.

8.
Bioengineering (Basel) ; 10(6)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37370631

RESUMO

This prospective study aimed to evaluate the success rate of partial pulpotomy using mineral trioxide aggregate (MTA), in permanent molars with symptomatic irreversible pulpitis. Moreover, this study aimed to investigate the effect of carious lesion depth and activity and bleeding time on the outcome of partial pulpotomy. Forty permanent molars with deep and extremely deep carious lesions clinically diagnosed with symptomatic irreversible pulpitis were included. The status of the carious lesion was evaluated clinically and radiographically to determine its activity (rapidly or slowly progressing) and depth (deep or extremely deep). A partial pulpotomy was performed and MTA was used. Clinical and radiographic analysis were performed at 3, 6 and 12 months. Chi-square analysis and Fisher's exact test were used. Scanning electron microscope and energy dispersive X-rays were used to investigate the crystalline structures and their chemical composition onto MTA surfaces after immersion in several conditions. The partial pulpotomy was 88.9% successful, with no significant difference in outcome between deep and extremely deep carious lesions (p = 0.22) or between rapidly and slowly progressing lesions (p = 0.18). Nevertheless, all failed cases were associated with rapidly progressing lesions and extremely deep lesions. All failures occurred when the bleeding time was more than 3 min (p = 0.10). Different crystalline structures were detected on MTA surfaces, with higher calcium percentages in PBS conditions. Within the limitations of the present study, favorable results demonstrated that MTA might be recommended as a suitable agent for partial pulpotomy in permanent molars with irreversible pulpitis. The depth and activity of the carious lesion as well as the bleeding time are important factors in the success of partial pulpotomy treatment. The prolonged bleeding time and the extremely deep rapidly progressing caries could be related with the failure cases in partial pulpotomy treatment of irreversible pulpitis.

9.
Cancers (Basel) ; 15(12)2023 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-37370757

RESUMO

The role of the tumor microenvironment in tumor growth and therapy has recently attracted more attention in research and drug development. The ability of the microenvironment to trigger tumor maintenance, progression, and resistance is the main cause for treatment failure and tumor relapse. Accumulated evidence indicates that the maintenance and progression of tumor cells is determined by components of the microenvironment, which include stromal cells (endothelial cells, fibroblasts, mesenchymal stem cells, and immune cells), extracellular matrix (ECM), and soluble molecules (chemokines, cytokines, growth factors, and extracellular vesicles). As a solid tumor, melanoma is not only a tumor mass of monolithic tumor cells, but it also contains supporting stroma, ECM, and soluble molecules. Melanoma cells are continuously in interaction with the components of the microenvironment. In the present review, we focus on the role of the tumor microenvironment components in the modulation of tumor progression and treatment resistance as well as the impact of the tumor microenvironment as a therapeutic target in melanoma.

10.
J Funct Biomater ; 14(5)2023 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-37233396

RESUMO

Any excess solvent from dental adhesive systems must be eliminated prior to material photopolymerization. For this purpose, numerous approaches have been proposed, including the use of a warm air stream. This study aimed to investigate the effect of different temperatures of warm air blowing used for solvent evaporation on the bond strength of resin-based materials to dental and nondental substrates. Two different reviewers screened the literature in diverse electronic databases. In vitro studies recording the effect of warm air blowing to evaporate solvents of adhesive systems on the bond strength of resin-based materials to direct and indirect substrates were included. A total of 6626 articles were retrieved from all databases. From this, 28 articles were included in the qualitative analysis, and 27 remained for the quantitative analysis. The results of the meta-analysis for etch-and-rinse adhesives revealed that the use of warm air for solvent evaporation was statistically significantly higher (p = 0.005). For self-etch adhesives and silane-based materials, this effect was observed too (p < 0.001). The use of a warm air stream for solvent evaporation enhanced the bonding performance of alcohol-/water-based adhesive systems for dentin. This effect seems to be similar when a silane coupling agent is submitted to a heat treatment before the cementation of a glass-based ceramic.

11.
J Clin Med ; 12(8)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37109310

RESUMO

This paper investigates the influence of cavity configuration and post-endodontic restoration on the fracture resistance, failure mode and stress distribution of premolars by using a method of fracture failure test and finite elements analysis (FEA) coupled to Weibull analysis (WA). One hundred premolars were divided into one control group (Gcontr) (n = 10) and three experimental groups, according to the post-endodontic restoration (n = 30), G1, restored using composite, G2, restored using single fiber post and G3, restored using multifilament fiberglass posts (m-FGP) without post-space preparation. Each experimental group was divided into three subgroups according to the type of coronal cavity configuration (n = 10): G1O, G2O, and G3O with occlusal (O) cavity configuration; G1MO, G2MO, and G3MO with mesio-occlusal (MO); and G1MOD, G2MOD, and G3MOD with mesio-occluso-distal (MOD). After thermomechanical aging, all the specimens were tested under compression load, and failure mode was determined. FEA and WA supplemented destructive tests. Data were statistically analyzed. Irrespective of residual tooth substance, G1 and G2 exhibited lower fracture resistance than Gcontr (p < 0.05), whereas G3 showed no difference compared to Gcontr (p > 0.05). Regarding the type of restoration, no difference was highlighted between G1O and G2O, G1MO and G2MO, or G1MOD and G2MOD (p > 0.05), whereas G3O, G3MO, and G3MOD exhibit higher fracture resistance (p < 0.05) than G1O and G2O, G1MO and G2MO, and G1MOD and G2MOD, respectively. Regarding cavity configuration: in G1 and G2, G1O and G2O exhibited higher fracture resistance than G1MOD and G2MOD, respectively (p < 0.05). In G3, there was no difference among G3O, G3MO and G3MOD (p > 0.05). No difference was found among the different groups and subgroups regarding the failure mode. After aging, premolars restored with multifilament fiberglass posts demonstrated fracture resistance values comparable to those of an intact tooth, irrespective of the different type of cavity configuration.

12.
Materials (Basel) ; 16(8)2023 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-37109947

RESUMO

The aim of the present study was to investigate the influence of the mechanical properties of three different calcium-silicate-based cements on the stress distribution of three different retrograde cavity preparations. Biodentine™ "BD", MTA Biorep "BR", and Well-Root™ PT "WR" were used. The compression strengths of ten cylindrical samples of each material were tested. The porosity of each cement was investigated by using micro-computed X-ray tomography. Finite element analysis (FEA) was used to simulate three retrograde conical cavity preparations with an apical diameter of 1 mm (Tip I), 1.4 mm (Tip II), and 1.8 mm (Tip III) after an apical 3 mm resection. BR demonstrated the lowest compression strength values (17.6 ± 5.5 MPa) and porosity percentages (0.57 ± 0.14%) compared to BD (80 ± 17 MPa-1.22 ± 0.31%) and WR (90 ± 22 MPa-1.93 ± 0.12%) (p < 0.05). FEA demonstrated that the larger cavity preparation demonstrated higher stress distribution in the root whereas stiffer cement demonstrated lower stress in the root but higher stress in the material. We can conclude that a respected root end preparation associated with cement with good stiffness could offer optimal endodontic microsurgery. Further studies are needed to define the adapted cavity diameter and cement stiffness in order to have optimal mechanical resistance with less stress distribution in the root.

13.
Bioengineering (Basel) ; 10(3)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36978753

RESUMO

The objective of the present in vitro work was to investigate the effectiveness and time required for the removal of calcium silicate-based sealer using two rotary retreatment systems. Sixty extracted, single-canal, lower premolars were used. After obturation using the single-cone technique with calcium silicate-based sealer, samples were divided into four groups according to the technique of desobturation: Group 1 (G1): D-Race; Group 2 (G2): D-Race followed by the use of XP-Endo Finisher R; Group 3 (G3): Protaper Universal Retreatment; and Group 4 (G4): Protaper Universal Retreatment followed by the use of XP-Endo Finisher R. Cone beam computed tomography (CBCT) images were used to calculate the remaining filling materials at the middle and apical thirds. Times required to perform each method were recorded. Scanning electron microscopy (SEM) and digital microscopy were used to evaluate the remaining filling materials. Data were statistically analyzed using the t-test and one way ANOVA on ranks tests. No statistically significant difference was found between G1 and G3 after CBCT observations (p > 0.05). Xp-Endo Finisher R significantly increased the ability to remove materials regardless of the initially used retreatment system (p < 0.05). Statistically significant longer time was found in G3 and G4 compared to G1 and G2, respectively (p < 0.05), to reach the full working length. No retreatment system was able to totally remove the calcium silicate-based sealer from the root canal at the middle and apical thirds (p > 0.05). Digital microscopy demonstrated that the residual materials were the remaining sealers on the canal walls. SEM showed the mineral depositions of calcium silicate materials onto the canal walls and into the dentinal tubules. However, that calcium silicate materials provide mineral deposition into the dentinal tubules might indicate that the traditional irrigants could not be sufficient to remove calcium silicate-based materials from the root canal, and other agents should be used to make retreatment considerably easier.

14.
Int J Mol Sci ; 24(6)2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36982421

RESUMO

The antimicrobial protein S100A15 belongs to the S100 family, which is differentially expressed in a variety of normal and pathological tissues. Although the function of S100A15 protein has been discussed in several studies, its induction and regulation in oral mucosa, so far, are largely unknown. In this study, we demonstrate that S100A15 is induced by the stimulation of oral mucosa with gram- or gram+ bacterial pathogens, as well as with the purified membrane components, namely lipopolysaccharides (LPS) and lipoteichoic acid (LTA). The stimulation of the human gingival fibroblast (GF) and the human mouth epidermal carcinoma (KB) cell lines with either gram- or gram+ bacterial pathogens or their purified membrane components (LPS and LTA) results in the activation of NF-κB, apoptosis-regulating kinase1 (ASK1), and MAP kinase signaling pathways including, c-Jun N-terminal kinase (JNK) and p38 together with their physiological substrates AP-1 and ATF-2, respectively. Inhibition of S100A15 by antibodies-mediated Toll-like receptor 4 (TLR4) or Toll-like receptor 2 (TLR2) neutralization reveals the induction of S100A15 protein by LPS/gram- bacterial pathogens to be TLR4- dependent mechanism, whereas induction by LTA/gram+ bacterial pathogens to be TLR2- dependent mechanism. Pre-treatment of GF and KB cells with JNK (SP600125), p38 (SB-203580), or NF-κB (Bay11-7082) specific inhibitors further demonstrates the importance of JNK, p38 and NF-κB pathways in the regulation of gram-/gram+ bacterial pathogen-induced S100A15 expression. Our data provide evidence that S100A15 is induced in cancer and non-cancer oral mucosa-derived cell lines by gram-/gram+ bacterial pathogens and provide insight into the molecular mechanisms by which gram- and gram+ bacterial pathogens induce S100A15 expression in the oral mucosa.


Assuntos
Anti-Infecciosos , NF-kappa B , Humanos , Anti-Infecciosos/farmacologia , Proteínas Quinases JNK Ativadas por Mitógeno/metabolismo , Lipopolissacarídeos/farmacologia , Lipopolissacarídeos/metabolismo , NF-kappa B/metabolismo , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo , Transdução de Sinais , Receptor 2 Toll-Like/metabolismo , Receptor 4 Toll-Like , Receptores Toll-Like
15.
Bioengineering (Basel) ; 10(2)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36829708

RESUMO

Currently, it remains unclear which specific peptides could be appropriate for applications in different fields of dentistry. The aim of this scoping review was to scan the contemporary scientific papers related to the types, uses and applications of peptides in dentistry at the moment. Literature database searches were performed in the following databases: PubMed/MEDLINE, Scopus, Web of Science, Embase, and Scielo. A total of 133 articles involving the use of peptides in dentistry-related applications were included. The studies involved experimental designs in animals, microorganisms, or cells; clinical trials were also identified within this review. Most of the applications of peptides included caries management, implant osseointegration, guided tissue regeneration, vital pulp therapy, antimicrobial activity, enamel remineralization, periodontal therapy, the surface modification of tooth implants, and the modification of other restorative materials such as dental adhesives and denture base resins. The in vitro and in vivo studies included in this review suggested that peptides may have beneficial effects for treating early carious lesions, promoting cell adhesion, enhancing the adhesion strength of dental implants, and in tissue engineering as healthy promotors of the periodontium and antimicrobial agents. The lack of clinical trials should be highlighted, leaving a wide space available for the investigation of peptides in dentistry.

16.
Bioengineering (Basel) ; 10(1)2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36671627

RESUMO

Oral cavities provide an entry point for food and nutrients [...].

17.
Cells ; 12(1)2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36611983

RESUMO

Diverse types of dental adhesives exhibit different cytotoxic outcomes on cells in vitro. Currently, no standard adhesive application technique has so far been decisive for clinicians for better durability of resin-dentin bonds of adhesive systems. The purpose of this study was to systematically review the literature to evaluate the bonding performance of adhesive systems to dentin by using different application modalities. The systematic research strategy was conducted by two reviewers among multiple databases: PubMed, Scopus, Web of Science, Embase, and Scielo. In vitro studies reporting the effects of additional steps for the application of adhesive systems on the bond strength to dentin were selected. Meta-analysis was performed using Review Manager Software version 5.3.5 using the random effects model. The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic review. The electronic research through different databases generated a total of 8318 references. After the examination of titles and abstracts, a total of 106 potentially relevant studies accessed the full-text evaluation phase. After full-text examination, 78 publications were included for the qualitative analysis, and 68 studies were included in the meta-analysis. Regarding the etch-and-rinse adhesive systems, the application modalities that improved the overall bond strength were the application of a hydrophobic resin layer (p = 0.005), an extended application time (p < 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p = 0.05), the agitation technique (p = 0.02), and the active application of the adhesive (p < 0.001). For self-etch adhesive systems, the techniques that improved the overall bond strength were the application of a hydrophobic resin layer (p < 0.001), an extended application time (p = 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p < 0.001), the agitation technique (p = 0.01), and the active application of the adhesive (p < 0.001). The in vitro evidence suggests that the application of adhesive systems using alternative techniques or additional strategies may be beneficial for improving their bond strength to dentin. The application modalities that favored the overall bond strength to dentin were an extended application time, a double-layer application, an application assisted by an electric current, the active application of the adhesive, and the application of a hydrophobic resin layer. Worth mentioning is that some techniques are intended to increase the degree of the conversion of the materials, and therefore, improvements in the biocompatibility of the materials can be expected.


Assuntos
Adesivos , Dentina , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química
18.
J Clin Med ; 11(22)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36431231

RESUMO

The aim of this in vitro study was to investigate the compressive strength and the bulk porosity of a bidirectional (bFRC) and an experimental bidirectional spiral winding reinforced fiber composite (bswFRC). Cylindrical-shape specimens were prepared for each material group and processed for the evaluation of compressive strength after different storage conditions (dry, 1 and 3 months) in distilled water at 37 °C. The specimens were also assessed for the degree of bulk porosity through X-ray tomography. A scanning electron microscope (SEM) was used to determine the fracture mode after a compressive strength test. Data were statistically analyzed using Two-Way Analysis of Variance (ANOVA). A significantly lower compressive strength was obtained in dry conditions, and after 1 month of water immersion, with the specimens created with bFRC compared to those made with bswFRC (p < 0.05). No significant difference (p > 0.05) was found between the two groups after 3 months of water immersion. However, the presence of water jeopardized significantly the compressive strength of bswFRC after water storage. The type of fracture was clearly different between the two groups; bswFRC showed a brutal fracture, whilst bFRC demonstrated a shear fracture. The bswFRC demonstrated higher pore volume density than bFRC. In conclusion, bswFRC is characterized by greater compressive strength compared to bFRC in dry conditions, but water-aging can significantly decrease the mechanical properties of such an innovative FRC. Therefore, both the novel bidirectional spiral winding reinforced fiber composites (bswFRC) and the bidirectional fiber reinforced composites (bFRC) might represent suitable materials for the production of post-and-core systems via CAD/CAM technology. These findings suggest that both FRC materials have the potential to strengthen the endodontically treated teeth.

19.
Bioengineering (Basel) ; 9(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36354535

RESUMO

The purpose of the present study was to evaluate the physicochemical properties and antibacterial activity of three calcium silicate cements. Mineral trioxide aggregate (MTA Biorep "BR"), Biodentine (BD) and Well-Root PT (WR) materials were investigated using scanning electron microscopy (SEM) at 24, 72 and 168 h of immersion in phosphate buffered saline (PBS). The antibacterial activity against Enterococcus faecalis (E. faecalis), the solubility, roughness, pH changes and water contact angle were also analyzed. All results were statistically analyzed using a one-way analysis of variance test. Statistically significant lower pH was detected for BD than WR and BR (p < 0.05). No statistical difference was found among the three materials for the efficacy of kill against E. faecalis (p > 0.05). Good antibacterial activity was observed (kill 50% of bacteria) after 24 h of contact. The wettability and the roughness of BR were higher than for the other cements (p < 0.05). BD was more soluble than WR and BR (p < 0.05). In conclusion, the use of bioceramic cements as retrograde materials may play an important role in controlling bacterial growth and in the development of calcium phosphate surface layer to support healing. Moreover, the premixed cement was easier to use than powder−liquid cement.

20.
Pharmaceutics ; 14(10)2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36297613

RESUMO

Life-threatening diseases challenge immunity with a release of chromogranins. This report focuses on Chromogranin A (CGA) and some of its derived peptides in critically ill patients, with attention paid to their potential to become biomarkers of severity and actors of defense. First, we studied whether circulating CGA may be a biomarker of outcome in non-selected critically ill patients: CGA concentrations were reliably associated with short-term death, systemic inflammation, and multiple organ failure. Additionally, when studying Vasostatin-I, the major N-terminal fragment of CGA, we noted its reliable prognostic value as early as admission if associated with age and lactate. In trauma patients, CGA concentrations heralded the occurrence of care-related infections. This was associated with an in vitro inhibitor impact of Chromofungin on both NF-kappa B- and API-transcriptional activities. Secondly, in life-threatening disease-induced oxidative stress, the multimerization of Vasostatin-I occurs with the loss of its anti-microbial properties ex vivo. In vivo, a 4%-concentration of non-oxidized albumin infusion reversed multimerization with a decrease in care-related infections. Finally, in vitro Catestatin impacted the polymorphonuclear cells-Ca++-dependent, calmodulin-regulated iPLA2 pathway by releasing immunity-related proteins. Furthermore, human Cateslytin, the active domain of Catestatin, helped destroy S. aureus: this prompted the creation of synthetic D-stereoisomer of CGA-derived peptides against superbugs for the protection of implanted devices. In conclusion, CGA consideration in the critically ill is only starting, but it offers interesting perspectives for improved outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...