Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37477946

RESUMO

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Inteligência Artificial , Estudos de Viabilidade , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Algoritmos , Ablação por Cateter/métodos
2.
Med Devices (Auckl) ; 13: 67-73, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32210643

RESUMO

AIM: To assess the efficacy of the TriGUARD 3™, a novel cerebral embolic protection (CEP) device in reducing cerebral embolization by deflecting embolic debris away from the cerebral circulation using a quantitative in vitro model. METHODS AND RESULTS: This in vitro study assessed the ability of a cerebral embolic protection device to deflect embolic debris, by measuring the percent of particles and air bubbles, 200 µm and 300 µm in size, from entering the cerebral circulation compared to unprotected controls. A 3D printed silicone model of the ascending aorta, the aortic arch with its three major cerebral arteries and the descending aorta was connected to a custom-made simulator that mimics physiological pulsatile flow patterns of the left ventricle. Comparative analyses were used to assess the efficacy of the cerebral embolic protection device to deflect particles and air bubbles away from the major cerebral arteries. The percent of particles and air bubbles entering the major cerebral arteries was significantly lower with cerebral embolic protection compared to unprotected controls (p<0.0001). Cerebral protection resulted in 97.4-100% reduction in air bubble counts, and 97.4-97.8% reduction in particle counts compared to unprotected controls. CONCLUSION: This in vitro study used simulated physiologic flow conditions in an aortic arch model to demonstrate >97% efficacy of the TriGUARD 3 CEP device, in reducing cerebral embolization of particulate and air bubbles of 200 µm to 300 µm in size.

3.
J Clin Psychopharmacol ; 29(5): 444-52, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19745644

RESUMO

The purpose of this study was to characterize the brain activity and associated cortical structures involved in pseudobulbar affect (PBA), a condition characterized by uncontrollable episodes of laughing and/or crying in patients with multiple sclerosis before and after treatment with dextromethorphan/quinidine (DM/Q). Behavioral responses and event-related potentials (ERPs) in response to subjectively significant and neutral verbal stimuli were recorded from 2 groups: 6 multiple sclerosis patients with PBA before (PBA-preTx) and after (PBA-DM/Q) treatment with DM/Q and 6 healthy control (HC) subjects. Statistical nonparametric mapping comparisons of ERP source current density distributions between groups were conducted for subjectively significant and neutral stimuli separately before and after treatment with DM/Q. Treatment with DM/Q had a normalizing effect on the behavioral responses of PBA patients. Event-related potential waveform comparisons of PBA-preTx and PBA-DM/Q with HC, for both neutral and subjectively significant stimuli, revealed effects on early ERP components. Comparisons between PBA-preTx and HC, in response to subjectively significant stimuli, revealed both early and late effects. Source analysis comparisons between PBA-preTx and PBA-DM/Q indicated distinct activations in areas involved in emotional processing and high-level and associative visual processing in response to neutral stimuli and in areas involved in emotional, somatosensory, primary, and premotor processing in response to subjectively significant stimuli. In most cases, stimuli evoked higher current density in PBA-DM/Q compared with the other groups. In conclusion, differences in brain activity were observed before and after medication. Also, DM/Q administration resulted in normalization of behavioral and electrophysiological measures.


Assuntos
Dextrometorfano/administração & dosagem , Potenciais Evocados Auditivos/fisiologia , Esclerose Múltipla/fisiopatologia , Paralisia Pseudobulbar/fisiopatologia , Quinidina/administração & dosagem , Estimulação Acústica/métodos , Adulto , Potenciais Evocados Auditivos/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/tratamento farmacológico , Paralisia Pseudobulbar/tratamento farmacológico , Desempenho Psicomotor/efeitos dos fármacos , Desempenho Psicomotor/fisiologia
4.
J Neurol Sci ; 271(1-2): 137-47, 2008 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-18504049

RESUMO

PURPOSE: To characterize the brain activity and associated cortical structures involved in pseudobulbar affect (PBA), a condition characterized by uncontrollable episodes of emotional lability in patients with multiple sclerosis (MS). METHODS: Behavioral responses and event related potentials (ERP) in response to subjectively significant and neutral verbal stimuli were recorded from 33 subjects in 3 groups: 1) MS patients with PBA (MS+PBA); 2) MS patients without PBA (MS); 3) Healthy control subjects (HC). Statistical non-parametric mapping comparisons of ERP source current density distributions between groups were conducted separately for subjectively significant and for neutral stimuli. RESULTS: Behavioral responses showed more impulsive performance in patients with PBA. As expected, almost all ERP waveform comparisons between the MS groups and controls were significant. Source analysis indicated significantly distinct activation in MS+PBA in the vicinity of the somatosensory and motor areas in response to neutral stimuli, and at pre-motor and supplementary motor areas in response to subjectively significant stimuli. Both subjectively significant and neutral stimuli evoked higher current density in MS+PBA compared to both other groups. CONCLUSIONS: PBA of MS patients involves cortical structures related to sensory-motor and emotional processing, in addition to overactive involvement of motor cortical areas in response to neutral stimuli. SIGNIFICANCE: These results may suggest that a 'disinhibition' of a "gate control"-type mechanism for emotional expression may lead to the lower emotional expression threshold of pseudobulbar affect.


Assuntos
Encéfalo/fisiopatologia , Emoções , Potenciais Evocados/fisiologia , Esclerose Múltipla/patologia , Paralisia Pseudobulbar/patologia , Estimulação Acústica/métodos , Adulto , Análise de Variância , Mapeamento Encefálico , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Paralisia Pseudobulbar/complicações , Tempo de Reação/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...