Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
2.
Am J Cardiol ; 205: 1-9, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37573632

RESUMO

Transcatheter aortic valve replacement (TAVR) carries a risk of high-grade AV block requiring cardiac implantable electronic device (CIED) implantation, which has been associated with a higher mortality rate. However, the outcomes of TAVR in patients with preexisting CIEDs are not well understood. We conducted a retrospective analysis of consecutive patients who underwent TAVR from December 2014 to December 2019 at our institution. Patients were categorized into 3 groups: preexisting CIED pre-TAVR (group 1), CIED implanted within 30 days after TAVR (group 2), and no CIED implanted (group 3). Cox proportional hazard was conducted to determine the primary end point of all-cause mortality. A total of 366 patients were included, of whom 93 (25.4%), 51 (13.9%), and 222 (60.7%) comprised group 1, 2, and 3, respectively. The median follow-up time was 2.3 years. The all-cause mortality rate was higher in group 1 than group 2 (hazard ratio [HR] 2.60, 95% confidence interval [CI] 1.09 to 6.18, p = 0.03) and group 3 (HR 1.96, 95% CI 1.24 to 3.08, p = 0.004). On the multivariate analysis, there was no statistically significant difference in mortality among the groups (group 1 vs group 2: HR 1.95, 95% CI 0.70 to 5.44, p = 0.20 and group 1 vs group 3: HR 1.27, 95% CI 0.66 to 2.43, p = 0.47). Preoperative hemoglobin ≤12 g/100 ml was an independent predictor of all-cause mortality (HR 1.75, 95% CI 1.10 to 2.80, p = 0.02). Group 1 had a higher 1 year congestive heart failure readmission rate (29%) than group 2 (17.6%) and group 3 (8.1%; p <0.0001). In conclusion, there was no difference in the adjusted long-term survival based on the CIED grouping. However, patients with preexisting CIEDs had higher all-cause mortality and 1-year congestive heart failure readmission rates owing to their higher co-morbidity burden, irrespective of their Society of Thoracic Surgeons score. This can be taken into account for preoperative risk stratification.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco , Insuficiência Cardíaca/complicações , Valva Aórtica/cirurgia
3.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1802-1803, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37480869
7.
Heart Rhythm ; 20(9): 1238-1245, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37211146

RESUMO

BACKGROUND: Freedom from atrial arrhythmia (AA) recurrence ≥30 seconds after pulsed field ablation (PFA) in patients with atrial fibrillation (AF) was reported in PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; ClinialTrials.gov Identifier: NCT04198701). AA burden may be a more clinically meaningful endpoint. OBJECTIVE: The purpose of this study was to determine the influence of monitoring strategies on AA detection and AA burden association with quality of life (QoL) and health care utilization (HCU) after PFA. METHODS: Patients underwent 24-hour Holter monitoring at 6 and 12 months and weekly, and symptomatic transtelephonic monitoring (TTM). AA burden post-blanking was calculated as the greater of (1) percentage of AA on total Holter time; or (2) percentage of weeks with ≥1 TTM with AA out of all weeks with ≥1 TTM. RESULTS: Freedom from all AAs varied by >20% when differing monitoring strategies were used. PFA resulted in zero burden in 69.4% of paroxysmal atrial fibrillation (PAF) and 62.2% of persistent atrial fibrillation (PsAF) patients. Median burden was low (<9%). Most PAF and PsAF patients had ≤1 week of AA detection on TTM (82.6% and 75.4%) and <30 minutes of AA per day of Holter monitoring (96.5% and 89.6%), respectively. Only PAF patients with <10% AA burden averaged a clinically meaningful (>19 point) QoL improvement. PsAF patients experienced clinically meaningful QoL improvements irrespective of burden. Repeat ablations and cardioversions significantly increased with higher AA burden (P <.01). CONCLUSION: The ≥30-second AA endpoint is dependent on the monitoring protocol used. PFA resulted in low AA burden for most patients, which was associated with clinically relevant improvement in QoL and reduced AA-related HCU.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Qualidade de Vida , Resultado do Tratamento , Ablação por Cateter/métodos , Aceitação pelo Paciente de Cuidados de Saúde , Recidiva , Veias Pulmonares/cirurgia
8.
Circulation ; 147(19): 1422-1432, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-36877118

RESUMO

BACKGROUND: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. METHODS: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. RESULTS: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. CONCLUSIONS: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04198701.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
9.
J Interv Card Electrophysiol ; 66(4): 1015-1028, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35969338

RESUMO

Ablation strategies remain poorly defined for persistent atrial fibrillation (AF) patients with recurrence despite intact pulmonary vein isolation (PVI). As the ability to perform durable PVI improves, the need for advanced mapping to identify extra-PV sources of AF becomes increasingly evident. Multiple mapping technologies attempt to localize these self-sustained triggers and/or drivers responsible for initiating and/or maintaining AF; however, current approaches suffer from technical limitations. Electrographic flow (EGF) mapping is a novel mapping method based on well-established principles of optical flow and fluid dynamics. It enables the full spatiotemporal reconstruction of organized wavefront propagation within the otherwise chaotic and disorganized electrical conduction of AF. Given the novelty of EGF mapping and relative unfamiliarity of most clinical electrophysiologists with the mathematical principles powering the EGF algorithm, this paper provides an in-depth explanation of the technical/mathematical foundations of EGF mapping and demonstrates clinical applications of EGF mapping data and analyses. Starting with a 64-electrode basket catheter, unipolar EGMs are recorded and processed using an algorithm to visualize the electrographic flow and highlight the location of high prevalence AF "source" activity. The AF sources are agnostic to the specific mechanisms of source signal generation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fator de Crescimento Epidérmico , Resultado do Tratamento , Ablação por Cateter/métodos , Algoritmos , Veias Pulmonares/cirurgia , Recidiva
10.
Circ Arrhythm Electrophysiol ; 15(6): e010127, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35649121

RESUMO

BACKGROUND: Phrenic nerve palsy is a well-known complication of cardiac ablation, resulting from the application of direct thermal energy. Emerging pulsed field ablation (PFA) may reduce the risk of phrenic nerve injury but has not been well characterized. METHODS: Accelerometers and continuous pacing were used during PFA deliveries in a porcine model. Acute dose response was established in a first experimental phase with ascending PFA intensity delivered to the phrenic nerve (n=12). In a second phase, nerves were targeted with a single ablation level to observe the effect of repetitive ablations on nerve function (n=4). A third chronic phase characterized assessed histopathology of nerves adjacent to ablated cardiac tissue (n=6). RESULTS: Acutely, we observed a dose-dependent response in phrenic nerve function including reversible stunning (R2=0.965, P<0.001). Furthermore, acute results demonstrated that phrenic nerve function responded to varying levels of PFA and catheter proximity placements, resulting in either: no effect, effect, or stunning. In the chronic study phase, successful isolation of superior vena cava at a dose not predicted to cause phrenic nerve dysfunction was associated with normal phrenic nerve function and normal phrenic nerve histopathology at 4 weeks. CONCLUSIONS: Proximity of the catheter to the phrenic nerve and the PFA dose level were critical for phrenic nerve response. Gross and histopathologic evaluation of phrenic nerves and diaphragms at a chronic time point yielded no injury. These results provide a basis for understanding the susceptibility and recovery of phrenic nerves in response to PFA and a need for appropriate caution in moving beyond animal models.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos dos Nervos Periféricos , Veias Pulmonares , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Suínos , Veia Cava Superior/cirurgia
13.
Pacing Clin Electrophysiol ; 45(4): 491-498, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35174901

RESUMO

BACKGROUND: An important complication of cardiac implantable electronic devices (CIED) implantation is the development of hematoma and device infection. OBJECTIVE: We aimed to evaluate a novel mechanical compression device for hematoma prevention and cosmetic outcomes following CIED implantation. METHODS: An open, prospective, randomized, single-center clinical trial was performed in patients undergoing CIED implantation. Patients were randomized to receive a novel mechanical compression device (PressRite, PR) or to receive the standard of care post device implantation. Skin pliability was measured with a calibrated durometer; the surgical site was evaluated using the Manchester Scar Scale (MSS) by a blinded plastic surgeon and the Patient and Observer Scar Scale (POSAS). Performance of PR was assessed through pressure measurements, standardized scar scales and tolerability. RESULTS: From the total of 114 patients evaluated for enrollment, 105 patients were eligible for analysis. Fifty-one patients were randomized to management group (PR) and 54 to the control group. No patients required early removal or experienced adverse effects from PR application. There were 11 hematomas (14.8% vs. 5.9% in the control and PR group respectively, p = NS). The control group had higher post procedure durometer readings in the surgical site when compared with the PR group (7.50 ± 3.45 vs. 5.37 ± 2.78; p = < .01). There were lower MSS scores in the PR group after 2 weeks (p = .03). CONCLUSION: We have demonstrated the safety of PR application and removal. In addition, PR appears to improve postoperative skin pliability, which could facilitate wound healing.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Hematoma/etiologia , Hematoma/prevenção & controle , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos
15.
Am J Cardiol ; 164: 57-63, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34815061

RESUMO

The incidence of new-onset secondary atrial fibrillation (NOSAF) is as high as 44% in noncardiac critical illness. A systematic review and meta-analysis were performed to evaluate the impact of NOSAF, compared with history of prior atrial fibrillation (AF) and no history of AF in noncardiac critically ill patients. Patients undergoing cardiothoracic surgery were excluded. NOSAF incidence, intensive care unit (ICU)/hospital length of stay (LOS), and mortality outcomes were analyzed. Of 2,360 studies reviewed, 19 studies met inclusion criteria (n = 306,805 patients). NOSAF compared with no history of AF was associated with increased in-hospital mortality (risk ratio [RR] 2.06, 95% confidence interval [CI] 1.76 to 2.41, p <0.001), longer ICU LOS (standardized difference in means [SMD] 0.66, 95% CI 0.41 to 0.91, p <0.001), longer hospital LOS (SMD 0.31, 95% CI 0.07 to 0.56, p = 0.001) and increased risk of long-term (>1 year) mortality (RR 1.76, 95% CI 1.29 to 2.40, p <0.001). NOSAF compared with previous AF was also associated with higher in-hospital mortality (RR 1.29, 95% CI 1.12 to 1.49, p <0.001), longer ICU LOS (SMD 0.37, 95% CI 0.03 to 0.70, p = 0.03) but no difference in-hospital LOS (SMD -0.18, 95% CI -0.66 to 0.31, p = 0.47). In conclusion, NOSAF, in the setting of noncardiac critical illness is associated with increased in-hospital mortality compared with no history of AF and previous AF. NOSAF (vs no history of AF) is also associated with increased long-term mortality.


Assuntos
Fibrilação Atrial/epidemiologia , Estado Terminal/epidemiologia , Mortalidade Hospitalar , Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Humanos
16.
Circ Arrhythm Electrophysiol ; 15(1): e010168, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34964367

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel form of ablation using electrical fields to ablate cardiac tissue. There are only limited data assessing the feasibility and safety of this type of ablation in humans. METHODS: PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; https://www.clinicaltrials.gov; unique identifier: NCT04198701) is a nonrandomized, prospective, multicenter, global, premarket clinical study. The first-in-human pilot phase evaluated the feasibility and efficacy of pulmonary vein isolation using a novel PFA system delivering bipolar, biphasic electrical fields through a circular multielectrode array catheter (PulseSelect; Medtronic, Inc). Thirty-eight patients with paroxysmal or persistent atrial fibrillation were treated in 6 centers in Australia, Canada, the United States, and the Netherlands. The primary outcomes were ability to achieve acute pulmonary vein isolation intraprocedurally and safety at 30 days. RESULTS: Acute electrical isolation was achieved in 100% of pulmonary veins (n=152) in the 38 patients. Skin-to-skin procedure time was 160±91 minutes, left atrial dwell time was 82±35 minutes, and fluoroscopy time was 28±9 minutes. No serious adverse events related to the PFA system occurred in the 30-day follow-up including phrenic nerve injury, esophageal injury, stroke, or death. CONCLUSIONS: In this first-in-human clinical study, 100% pulmonary vein isolation was achieved using only PFA with no PFA system-related serious adverse events. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Austrália , Canadá , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Duração da Cirurgia , Projetos Piloto , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
17.
Comput Cardiol (2010) ; 20222022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37124718

RESUMO

Pulsed field ablation (PFA) has the potential to evolve into an efficient alternative to traditional RF ablation for atrial fibrillation treatment. However, achieving irreversible tissue electroporation is critical to suppressing arrhythmic pathways, raising the need for accurate lesion characterization. To understand the physics behind the tissue response PFA, we propose a quasi-dynamic model that quantifies tissue conductance at end-electroporation and identifies regions that have undergone fully irreversible electroporation (IRE). The model uses several parameters and numerically solves the electrical field diffusion into the tissue by iteratively updating the tissue conductance until equilibrium at end-electroporation. The model yields a steady-state tissue conductance map used to identify the irreversible lesion. We conducted numerical experiments mimicking a lasso catheter featuring nine 3-mm electrodes spaced circumferentially at 3.75 mm and fired sequentially using a 1500 V and 3000 V pulse amplitude. The IRE lesion region has a surface area and volume of 780 mm2 and 1411 mm3, respectively, at 1500 V, and 1178 mm2 and 2760 mm3, respectively, at 3000 V. Lesion discontinuity was observed at 5.0 mm depth with 1500 V, and 7.2 mm depth with 3000 V. This quasi-dynamic model yields tissue conductance maps, predicts irreversible lesion and lesion penumbra at end-electroporation, and confirms larger lesions with higher pulse amplitudes.

19.
Prog Cardiovasc Dis ; 66: 2-9, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34023354

RESUMO

IMPORTANCE: It has been suggested that atrial fibrillation (AF) is the new cardiovascular disease epidemic of the 21st century. Clinical cardiology has largely focused on AF treatment and associated stroke prevention rather than preventing AF itself. To reduce the global consequences and associated costs of AF, it is critical to now embrace prevention as a priority. Proactively addressing the risk factors for AF and the underlying unhealthy lifestyle habits that contribute to them, using research-based counseling approaches, represents a complementary and adjunctive alternative in combatting this disease burden. OBSERVATIONS: Encouraging and sustaining patient involvement to reduce AF incidence and improve outcomes begins with screening to identify risk factors, unhealthy lifestyle habits, and characteristics associated with failed attempts at favorably modifying these causalities. Modulators of and common barriers to achieving risk reduction and lifestyle change include self-efficacy, social support, age, sex, marital and socioeconomic status, education, employment, and psychosocial factors such as depression, isolation, anxiety and chronic life stress. Focused behavioral counseling approaches, including assessing the patient's readiness to change, motivational interviewing and using the 5 A's (assess, advise, agree, assist, arrange), along with employing initial downscaled goals to overcome inertia, are proven methodologies to overcome these common barriers to favorably modifying risk factors and unhealthy lifestyle habits. CONCLUSIONS AND RELEVANCE: To complement and enhance the current armamentarium for the medical management of cardiac arrhythmias, there is an urgent need to proactively address the causative factors triggering new-onset, recurrent and persistent AF. Beyond the counseling skills of highly trained professionals (eg, psychiatrists, psychologists), this narrative review highlights the need for and potential impact on lifestyle modification that non-behavioral scientists, including internal medicine, cardiology, and allied health professionals, can have on the patients they serve.


Assuntos
Técnicas de Ablação , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Estilo de Vida Saudável , Comportamento de Redução do Risco , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Comorbidade , Aconselhamento , Comportamentos Relacionados com a Saúde , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Educação de Pacientes como Assunto , Medição de Risco , Fatores de Risco , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 32(4): 958-969, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33650743

RESUMO

BACKGROUND: Pulsed field ablation (PFA) has been identified as an alternative to thermal-based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model. METHODS: A circular catheter with nine gold electrodes was used for overlapping low- or high-dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4-week survival. Acute and chronic safety data were recorded peri- and post-procedurally. RESULTS: No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA-related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non-thermally generated with only minimal post-delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus. CONCLUSION: PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4-week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non-thermal nature of PFA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Endocárdio , Humanos , Veias Pulmonares/cirurgia , Suínos , Veia Cava Superior
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...