1.
Radiol Phys Technol ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492203

RESUMO

The purpose of this study was to validate an electronic portal imaging device (EPID) based 3-dimensional (3D) dosimetry system for the commissioning of volumetric modulated arc therapy (VMAT) delivery for flattening filter (FF) and flattening filter free (FFF) modalities based on test suites developed according to American Association of Physicists in Medicine Task Group 119 (AAPM TG 119) and pre-treatment patient specific quality assurance (PSQA).With ionisation chamber, multiple-point measurement in various planes becomes extremely difficult and time-consuming, necessitating repeated exposure of the plan. The average agreement between measured and planned doses for TG plans is recommended to be within 3%, and both the ionisation chamber and PerFRACTION™ measurement were well within this prescribed limit. Both point dose differences with the planned dose and gamma passing rates are comparable with TG reported multi-institution results. From our study, we found that no significant differences were found between FF and FFF beams for measurements using PerFRACTION™ and ion chamber. Overall, PerFRACTION™ produces acceptable results to be used for commissioning and validating VMAT and for performing PSQA. The findings support the feasibility of integrating PerFRACTION™ into routine quality assurance procedures for VMAT delivery. Further multi-institutional studies are recommended to establish global baseline values and enhance the understanding of PerFRACTION™'s capabilities in diverse clinical settings.

2.
J Med Phys ; 47(1): 50-56, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35548036

RESUMO

Background: The photon dose calculation model anisotropic analytical algorithm (AAA) available with eclipse integrated treatment planning system (TPS) (Varian) supports telecobalt dose calculation from Version 13.6 onward. Formerly, pencil beam convolution (PBC) was used for modeling telecobalt machines. Eclipse TPS no longer supports PBC dose calculation algorithm in v13.6 and above. The AAA dose calculation model is a three-dimensional PBC/superposition algorithm. Its configuration is based on Monte-Carlo-determined basic physical parameters that are tailored to measured clinical beam data. Aim: The study investigated the feasibility of clinical implementation of AAA in Eclipse TPS for Bhabhatron II. Materials and Methods: The indigenous telecobalt machine, Bhabhatron II, was configured as a generic machine because an inbuilt machine model for the same was not available in Varian Eclipse TPS algorithm library. In such a scenario, it was necessary to evaluate and validate dosimetric parameters of the TPS because improper tailoring would cause errors in dose calculations. Beam data measurements of the machine were carried out which were used for configuration of the algorithm. Result: After successful configuration, a variety of plans created in TPS were executed on the machine and subsequently evaluated. Conclusion: From this study, we concluded that AAA-based dose calculation in TPS is very well suited for accurate dose calculations for telecobalt machine and can be implemented for clinical use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...