1.
Front Bioeng Biotechnol ; 12: 1363186, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38544982

RESUMO

Hydrolytic enzymes play crucial roles in cellular processes, and dysregulation of their activities is implicated in various physiological and pathological conditions. These enzymes cleave substrates such as peptide bonds, phosphodiester bonds, glycosidic bonds, and other esters. Detecting aberrant hydrolase activity is vital for understanding disease mechanisms and developing targeted therapeutic interventions. This study introduces a novel approach to measuring hydrolase activity using giant magnetoresistive (GMR) spin valve sensors. These sensors change resistance in response to magnetic fields, and here, they are functionalized with specific substrates for hydrolases conjugated to magnetic nanoparticles (MNPs). When a hydrolase cleaves its substrate, the tethered magnetic nanoparticle detaches, causing a measurable shift in the sensor's resistance. This design translates hydrolase activity into a real-time, activity-dependent signal. The assay is simple, rapid, and requires no washing steps, making it ideal for point-of-care settings. Unlike fluorescent methods, it avoids issues like autofluorescence and photobleaching, broadening its applicability to diverse biofluids. Furthermore, the sensor array contains 80 individually addressable sensors, allowing for the simultaneous measurement of multiple hydrolases in a single reaction. The versatility of this method is demonstrated with substrates for nucleases, Bcu I and DNase I, and the peptidase, human neutrophil elastase. To demonstrate a clinical application, we show that neutrophil elastase in sputum from cystic fibrosis patients hydrolyze the peptide-GMR substrate, and the cleavage rate strongly correlates with a traditional fluorogenic substrate. This innovative assay addresses challenges associated with traditional enzyme measurement techniques, providing a promising tool for real-time quantification of hydrolase activities in diverse biological contexts.

2.
Front Bioeng Biotechnol ; 11: 1256267, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37790251

RESUMO

Complications posed by preterm birth (delivery before 37 weeks of pregnancy) are a leading cause of newborn morbidity and mortality. The previous discovery and validation of an algorithm that includes maternal serum protein biomarkers, sex hormone-binding globulin (SHBG), and insulin-like growth factor-binding protein 4 (IBP4), with clinical factors to predict preterm birth represents an opportunity for the development of a widely accessible point-of-care assay to guide clinical management. Toward this end, we developed SHBG and IBP4 quantification assays for maternal serum using giant magnetoresistive (GMR) sensors and a self-normalizing dual-binding magnetic immunoassay. The assays have a picomolar limit of detections (LOD) with a relatively broad dynamic range that covers the physiological level of the analytes as they change throughout gestation. Measurement of serum from pregnant donors using the GMR assays was highly concordant with those obtained using a clinical mass spectrometry (MS)-based assay for the same protein markers. The MS assay requires capitally intense equipment and highly trained operators with a few days turnaround time, whereas the GMR assays can be performed in minutes on small, inexpensive instruments with minimal personnel training and microfluidic automation. The potential for high sensitivity, accuracy, and speed of the GMR assays, along with low equipment and personnel requirements, make them good candidates for developing point-of-care tests. Rapid turnaround risk assessment for preterm birth would enable patient testing and counseling at the same clinic visit, thereby increasing the timeliness of recommended interventions.

3.
Lab Chip ; 23(18): 4033-4043, 2023 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-37603416

RESUMO

Sample preparation is essential for nucleic acid assays, affecting their sensitivity and reliability. However, this process often results in a significant loss or dilution of the analyte, which becomes a bottleneck that limits downstream assay performance, particularly for assays that accept a limited input sample volume. To overcome this challenge, we present an evaporative-based sample enrichment method that uses an airjet to concentrate analytes within a small, defined volume by reversing the coffee-ring effect. A small, concentrated sample can then be collected for analysis to increase the initial sample load. The effectiveness of the reported airjet enrichment was quantified using qPCR of λ-DNA, HeLa-S3 RNA, and heat-inactivated SARS-CoV-2 samples. Comparisons between airjet enrichment and conventional evaporative concentration methods demonstrated significant advantages of airjet enrichment, including the ability to concentrate a high percentage of analyte within a 1 µL volume. The enrichment method was then integrated and adapted for various fluid volumes commonly found in nucleic acid sample preparation procedures. Here, airjet enrichment reduced the overall Cq by an average of 9.27 cycles for each analyte, resulting in a 600-fold enrichment from the initial concentration. To perform selective enrichment and prevent salt-based interference in downstream analysis, PEG was added to reduce the co-enrichment of salt. In addition, a preliminary study was conducted to explore the integration of airjet enrichment into ELISA using rabbit IgG as a model antigen. These findings demonstrate how airjet enrichment can be easily integrated into existing laboratory protocols with minimal modification and significantly improve the performance of biosensors.


Assuntos
COVID-19 , Animais , Coelhos , Reprodutibilidade dos Testes , SARS-CoV-2 , Cloreto de Sódio , RNA
4.
Nucleic Acids Res ; 51(13): 6841-6856, 2023 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-37246713

RESUMO

Horizontal gene transfer is tightly regulated in bacteria. Often only a fraction of cells become donors even when regulation of horizontal transfer is coordinated at the cell population level by quorum sensing. Here, we reveal the widespread 'domain of unknown function' DUF2285 represents an 'extended-turn' variant of the helix-turn-helix domain that participates in both transcriptional activation and antiactivation to initiate or inhibit horizontal gene transfer. Transfer of the integrative and conjugative element ICEMlSymR7A is controlled by the DUF2285-containing transcriptional activator FseA. One side of the DUF2285 domain of FseA has a positively charged surface which is required for DNA binding, while the opposite side makes critical interdomain contacts with the N-terminal FseA DUF6499 domain. The QseM protein is an antiactivator of FseA and is composed of a DUF2285 domain with a negative surface charge. While QseM lacks the DUF6499 domain, it can bind the FseA DUF6499 domain and prevent transcriptional activation by FseA. DUF2285-domain proteins are encoded on mobile elements throughout the proteobacteria, suggesting regulation of gene transfer by DUF2285 domains is a widespread phenomenon. These findings provide a striking example of how antagonistic domain paralogues have evolved to provide robust molecular control over the initiation of horizontal gene transfer.


Assuntos
Conjugação Genética , Proteobactérias , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Transferência Genética Horizontal , Proteobactérias/genética , Percepção de Quorum/genética , Fatores de Transcrição/metabolismo , Ativação Transcricional
5.
Biosens Bioelectron ; 227: 115097, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36858023

RESUMO

Stress is part of everyone's life and is exacerbated by traumatic events such as pandemics, disasters, violence, lifestyle changes, and health disorders. Chronic stress has many detrimental health effects and can even be life-threatening. Long-term stress monitoring outside of a hospital is often accomplished by measuring heart rate variability. While easy to measure, this digital biomarker has low specificity, greatly limiting its utility. To address this shortcoming, we report a non-invasive, wearable biomolecular sensor to monitor cortisol levels in sweat. Cortisol is a neuroendocrine hormone that regulates homeostasis as part of the stress pathway. Cortisol is detected using an electrochemical sensor functionalized with a pseudoknot-assisted aptamer and a flexible microfluidic sweat sampling system. The skin-worn microfluidic sampler provides rapid sweat collection while separating old and new sweat. The conformation-switching aptamer provides high specificity towards cortisol while being regenerable, allowing it to monitor temporal changes continuously. The aptamer was engineered to add a pseudoknot, restricting it to only two states, thus minimizing the background signal and enabling high sensitivity. An electrochemical pH sensor allows pH-corrected amperometric measurements. Device operation was demonstrated invitro with a broad linear dynamic range (1 pM - 1 µM) covering the physiological range and a sub-picomolar (0.2 pM) limit of detection in sweat. Real-time, on-body measurements were collected from human subjects using an induced stress protocol, demonstrating in-situ signal regeneration and the ability to detect dynamic cortisol fluctuations continuously for up to 90 min. The reported device has the potential to improve prognosis and enable personalized treatments.


Assuntos
Hidrocortisona , Microfluídica , Monitorização Fisiológica , Estresse Psicológico , Suor , Dispositivos Eletrônicos Vestíveis , Dispositivos Eletrônicos Vestíveis/normas , Hidrocortisona/análise , Aptâmeros de Nucleotídeos , Suor/química , Eletroquímica , Concentração de Íons de Hidrogênio , Limite de Detecção , Microfluídica/instrumentação , Microfluídica/métodos , Microfluídica/normas , Estresse Psicológico/fisiopatologia , Reprodutibilidade dos Testes , Eletrodos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Humanos , Sensibilidade e Especificidade
6.
Sci Rep ; 12(1): 22520, 2022 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-36581649

RESUMO

Although universal biometrics have been broadly called for, and there are many validated technologies to recognize adults, these technologies have been ineffective in newborns and young children. The present work describes the development and clinical testing of a fingerprint capture system for longitudinal biometric recognition of newborns and young children to support vaccination and clinical follow-up. The reader consists of a high-resolution monochromatic imaging system with an ergonomic industrial design to comfortably support and align infant fingers for imaging without a platen. This imaging approach without a platen, also called free-space imaging, reduces fingerprint distortion and ensures a more consistent finger placement. This system was tested in a newborn ward and immunization clinic at an urban hospital in Baja, California, Mexico, from 2017 to 2019. Nearly five hundred children were enrolled and followed for up to 24 months. With a protocol of imaging all ten fingers, the failure to enroll (FTE) rate was < 1% when acquiring at least two fingers for all ages and < 2% when enrolling at least four fingers. The verification (1:1) true accept rate (TAR) was 77% for newborns enrolled at ≤ 3 days of age and 96% for those enrolled at ≥ 4 days of age, both at a time gap of 15-30 days after enrollment at a false accept rate (FAR) of 0.1%. Using the top-ranked match score, the identification rate (1:many) was 86% for the ≤ 3 days enrollment age and 97% for age ≥ 4 days for a single finger at 15-30 days after enrollment. The enrollment protocol and the frequency of updating will increase for infants compared to adults. However, these data suggest that a high-resolution, free space imaging technique may fill the final gap for universal biometrics across all populations called for by the United Nations Sustainable Development Goal 16.9.


Assuntos
Biometria , Hospitais Urbanos , Lactente , Adulto , Humanos , Recém-Nascido , Criança , Pré-Escolar , Estudos Prospectivos , Atenção à Saúde , Vacinação
7.
ACS Omega ; 7(43): 39097-39106, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36340178

RESUMO

Monitoring the anti-epileptic drug carbamazepine (CBZ) is crucial for proper dosing, optimizing a patient's clinical outcome, and managing their medication regimen. Due to its narrow therapeutic window and concentration-related toxicity, CBZ is prescribed and monitored in a highly personalized manner. We report an electrochemical conformation-changing aptasensor with two assay formats: a 30 min assay for routine monitoring and a 5 min assay for rapid emergency testing. To enable "sample-to-answer" testing, a de novo CBZ aptamer (K d < 12 nM) with conformational switching due to a G-quadruplex motif was labeled with methylene blue and immobilized on a gold electrode. The electrode fabrication and detection conditions were optimized using electrochemical techniques and visualized by atomic force microscopy (AFM). The aptasensor performance, including reproducibility, stability, and interference, was characterized using electrochemical impedance spectroscopy and voltammetry techniques. The aptasensor exhibited a wide dynamic range in buffer (10 nM to 100 µM) with limits of detection of 1.25 and 1.82 nM for the 5 and 30 min assays, respectively. The clinical applicability is demonstrated by detecting CBZ in finger prick blood samples (<50 µL). The proposed assays provide a promising method to enable point-of-care monitoring for timely personalized CBZ dosing.

8.
IEEE Trans Biomed Circuits Syst ; 16(6): 1030-1043, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36191107

RESUMO

This work reports the first CMOS molecular electronics chip. It is configured as a biosensor, where the primary sensing element is a single molecule "molecular wire" consisting of a ∼100 GΩ, 25 nm long alpha-helical peptide integrated into a current monitoring circuit. The engineered peptide contains a central conjugation site for attachment of various probe molecules, such as DNA, proteins, enzymes, or antibodies, which program the biosensor to detect interactions with a specific target molecule. The current through the molecular wire under a dc applied voltage is monitored with millisecond temporal resolution. The detected signals are millisecond-scale, picoampere current pulses generated by each transient probe-target molecular interaction. Implemented in a 0.18 µm CMOS technology, 16k sensors are arrayed with a 20 µm pitch and read out at a 1 kHz frame rate. The resulting biosensor chip provides direct, real-time observation of the single-molecule interaction kinetics, unlike classical biosensors that measure ensemble averages of such events. This molecular electronics chip provides a platform for putting molecular biosensing "on-chip" to bring the power of semiconductor chips to diverse applications in biological research, diagnostics, sequencing, proteomics, drug discovery, and environmental monitoring.


Assuntos
Técnicas Biossensoriais , Eletrônica , Análise de Sequência com Séries de Oligonucleotídeos , Semicondutores , DNA/química , Nanotecnologia , Técnicas Biossensoriais/métodos
9.
IEEE Trans Biomed Circuits Syst ; 16(4): 692-702, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35900998

RESUMO

This paper presents an analog front-end (AFE) for fast-scan cyclic voltammetry (FSCV) with analog background subtraction using a pseudo-differential sensing scheme to cancel the large non-faradaic current before seeing the front-end. As a result, the AFE can be compact and low-power compared to conventional FSCV AFEs with dedicated digital back-ends to digitize and subtract the background from subsequent recordings. The reported AFE, fabricated in a 0.18- µ m CMOS process, consists of a class-AB common-mode rejection circuit, a low-input-impedance current conveyor, and a 1st-order current-mode delta-sigma (ΔΣ) modulator with an infinite impulse response quantizer. This AFE achieves an effective dynamic range of 83 dB with a state-of-the-art 39.2 pArms input-referred noise when loaded with a 1 nF input capacitance (26.5 pArms open-circuit) across a 5 kHz bandwidth while consuming an average power of 3.7 µW. This design was tested with carbon-fiber microelectrodes scanned at 300 V/s using flow-injection of dopamine, a key neurotransmitter.


Assuntos
Dopamina , Neurotransmissores , Carbono , Desenho de Equipamento , Microeletrodos
10.
Proc Natl Acad Sci U S A ; 119(5)2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35074874

RESUMO

For nearly 50 years, the vision of using single molecules in circuits has been seen as providing the ultimate miniaturization of electronic chips. An advanced example of such a molecular electronics chip is presented here, with the important distinction that the molecular circuit elements play the role of general-purpose single-molecule sensors. The device consists of a semiconductor chip with a scalable array architecture. Each array element contains a synthetic molecular wire assembled to span nanoelectrodes in a current monitoring circuit. A central conjugation site is used to attach a single probe molecule that defines the target of the sensor. The chip digitizes the resulting picoamp-scale current-versus-time readout from each sensor element of the array at a rate of 1,000 frames per second. This provides detailed electrical signatures of the single-molecule interactions between the probe and targets present in a solution-phase test sample. This platform is used to measure the interaction kinetics of single molecules, without the use of labels, in a massively parallel fashion. To demonstrate broad applicability, examples are shown for probe molecule binding, including DNA oligos, aptamers, antibodies, and antigens, and the activity of enzymes relevant to diagnostics and sequencing, including a CRISPR/Cas enzyme binding a target DNA, and a DNA polymerase enzyme incorporating nucleotides as it copies a DNA template. All of these applications are accomplished with high sensitivity and resolution, on a manufacturable, scalable, all-electronic semiconductor chip device, thereby bringing the power of modern chips to these diverse areas of biosensing.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletrônica/instrumentação , Ensaios Enzimáticos/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , DNA , Desenho de Equipamento/instrumentação , Cinética , Dispositivos Lab-On-A-Chip , Miniaturização/instrumentação , Nanotecnologia/instrumentação , Semicondutores
11.
Anal Bioanal Chem ; 414(10): 3187-3196, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34741182

RESUMO

We present an electrochemical impedimetric-based biosensor for monitoring the variation in human milk oligosaccharide (HMO) composition. 2'-Fucosyllactose (2'FL) is an HMO associated with infant growth, cognitive development, and protection from infectious diarrhea, one of the major causes of infant death worldwide. Due to genetic variation, the milk of some women (non-secretors) contains no or very little 2'FL with potential implications for infant health and development. However, there is currently no technology to analyze the presence and concentration of HMOs in human milk at the point-of-care (POC). The lack of such technology represents a major impediment to advancing human milk research and improving maternal-infant health. Towards this unmet need, we report an impedimetric assay for HMOs with an α-1,2 linkage, the most abundant of which is 2'FL. The sensor uses a lectin for affinity, specifically Ulex europaeus agglutinin I (UEA), with electrochemical readout. In spiked studies, the sensor exhibited a high degree of linearity (R2 = 0.991) over 0.5 to 3.0 µM with a 330-nM detection limit. The sensor performance was clinically validated using banked human milk samples and correctly identified all secretor vs. non-secretor samples. Furthermore, despite the short 35-min assay time and low sample volume (25 µL), the assay was highly correlated with HPLC measurements. This bedside human milk testing assay enables POC, "sample-to-answer" quantitative HMO measurement, and will be a valuable tool to assess milk composition.


Assuntos
Leite Humano , Sistemas Automatizados de Assistência Junto ao Leito , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Lactente , Leite Humano/química , Oligossacarídeos/química
12.
ACS Omega ; 6(42): 27888-27897, 2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34722988

RESUMO

There is a strong and growing need to monitor stress biomarkers in vivo for real-time emotional and wellness assessment. Toward this, we report a reagent-free electrochemical aptasensor with a nanocomposite antifouling layer for sensitive and continuous detection of cortisol in human serum. A thiolated, methylene blue (MB)-tagged conformation-switching aptamer was immobilized over a gold nanowire (AuNW) nanocomposite to capture cortisol and generate a signal proportional to the cortisol concentration. The signal is recorded through differential pulse voltammetry (DPV) and chronoamperometry. The aptasensor exhibited a sensitive response with 0.51 and 0.68 nM detection limits in spiked buffer and undiluted serum samples, respectively. Interference from other structurally similar analogs, namely, epinephrine and cholic acid, was negligible (<10%). The developed nanocomposite-based aptasensor showed excellent stability in undiluted human serum, outperforming several other nanocomposite materials even after prolonged exposure. This work lays the foundation for new biosensor formats such as implantable and wearable sensors.

13.
Data Brief ; 38: 107278, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34401413

RESUMO

We present supplementary data for the published article, "Hitting the diagnostic sweet spot: Point-of-care SARS-CoV-2 salivary antigen testing with an off-the-shelf glucometer" [1]. The assay described is designed to be performed at home or in a clinic without expensive instrumentation or professional training. SARS-CoV-2 is detected by an aptamer-based assay that targets the Nucleocapsid (N) or Spike (S) antigens. Binding of the N or S protein to their respective aptamer results in the competitive release of a complementary antisense-invertase enzyme complex. The released enzyme then catalyzes the conversion of sucrose to glucose that is measured by an off-the-shelf glucometer. The data presented here describe the optimization of the assay parameters and their contribution to developing this aptamer-based assay to detect SARS-CoV-2. The assay performance was checked in a standard buffer, contrived samples, and patient samples validated with well-established scientific methods. The resulting dataset can be used to further develop glucometer-based assays for diagnosing other communicable and non-communicable diseases.

14.
Sensors (Basel) ; 21(11)2021 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-34072374

RESUMO

A plasmonic sensing platform was developed as a noninvasive method to monitor gas-phase biomarkers related to cystic fibrosis (CF). The nanohole array (NHA) sensing platform is based on localized surface plasmon resonance (LSPR) and offers a rapid data acquisition capability. Among the numerous gas-phase biomarkers that can be used to assess the lung health of CF patients, acetaldehyde was selected for this investigation. Previous research with diverse types of sensing platforms, with materials ranging from metal oxides to 2-D materials, detected gas-phase acetaldehyde with the lowest detection limit at the µmol/mol (parts-per-million (ppm)) level. In contrast, this work presents a plasmonic sensing platform that can approach the nmol/mol (parts-per-billion (ppb)) level, which covers the required concentration range needed to monitor the status of lung infection and find pulmonary exacerbations. During the experimental measurements made by a spectrometer and by a smartphone, the sensing examination was initially performed in a dry air background and then with high relative humidity (RH) as an interferent, which is relevant to exhaled breath. At a room temperature of 23.1 °C, the lowest detection limit for the investigated plasmonic sensing platform under dry air and 72% RH conditions are 250 nmol/mol (ppb) and 1000 nmol/mol (ppb), respectively.


Assuntos
Fibrose Cística , Biomarcadores , Testes Respiratórios , Fibrose Cística/diagnóstico , Expiração , Humanos , Ressonância de Plasmônio de Superfície
15.
ACS Sens ; 6(5): 1971-1979, 2021 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-34008963

RESUMO

An electrochemical sensor based on a conformation-changing aptamer is reported to detect soluble KIT, a cancer biomarker, in human serum. The sensor was fabricated with a ferrocene-labeled aptamer (Kd < 5 nM) conjugated to a gold electrode. Quantitative KIT detection was achieved using electrochemical impedance spectroscopy (EIS) and square-wave voltammetry (SWV). EIS was used to optimize experimental parameters such as the aptamer-to-spacer ratio, aptamer immobilization time, pH, and KIT incubation time, and the sensor surface was characterized using voltammetry. The assay specificity was demonstrated using interfering species and exhibited high specificity toward the target protein. The aptasensor showed a wide dynamic range, 10 pg/mL-100 ng/mL in buffer, with a 1.15 pg/mL limit of detection. The sensor also has a linear response to KIT spiked in human serum and successfully detected KIT in cancer-cell-conditioned media. The proposed aptasensor has applications as a continuous or intermittent approach for cancer therapy monitoring and diagnostics (theranostics).


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Neoplasias , Técnicas Eletroquímicas , Humanos , Neoplasias/diagnóstico , Neoplasias/terapia , Medicina de Precisão
16.
Biosens Bioelectron ; 180: 113111, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33743492

RESUMO

Significant barriers to the diagnosis of latent and acute SARS-CoV-2 infection continue to hamper population-based screening efforts required to contain the COVID-19 pandemic in the absence of widely available antiviral therapeutics or vaccines. We report an aptamer-based SARS-CoV-2 salivary antigen assay employing only low-cost reagents ($3.20/test) and an off-the-shelf glucometer. The test was engineered around a glucometer as it is quantitative, easy to use, and the most prevalent piece of diagnostic equipment globally, making the test highly scalable with an infrastructure that is already in place. Furthermore, many glucometers connect to smartphones, providing an opportunity to integrate with contact tracing apps, medical providers, and electronic health records. In clinical testing, the developed assay detected SARS-CoV-2 infection in patient saliva across a range of viral loads - as benchmarked by RT-qPCR - within 1 h, with 100% sensitivity (positive percent agreement) and distinguished infected specimens from off-target antigens in uninfected controls with 100% specificity (negative percent agreement). We propose that this approach provides an inexpensive, rapid, and accurate diagnostic for distributed screening of SARS-CoV-2 infection at scale.


Assuntos
Antígenos Virais/análise , Técnicas Biossensoriais/métodos , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Testes Imediatos , SARS-CoV-2/imunologia , Saliva/virologia , Adulto , Teste para COVID-19 , Proteínas do Nucleocapsídeo de Coronavírus/análise , Feminino , Humanos , Masculino , Fosfoproteínas/análise , SARS-CoV-2/isolamento & purificação , Técnica de Seleção de Aptâmeros , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus/análise
17.
IEEE Trans Biomed Circuits Syst ; 15(1): 143-158, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33577456

RESUMO

Cardiovascular disease (CVD) threatens the lives of many and affects their productivity. Wearable sensors can enable continuous monitoring of hemodynamic parameters to improve the diagnosis and management of CVD. Bio-Impedance (Bio-Z) is an effective non-invasive sensor for arterial pulse wave monitoring based on blood volume changes in the artery due to the deep penetration of its current signal inside the tissue. However, the measured data are significantly affected by the placement of electrodes relative to the artery and the electrode configuration. In this work, we created a Bio-Z simulation platform that models the tissue, arterial pulse wave, and Bio-Z sensing configuration using a 3D circuit model based on a time-varying impedance grid. A new method is proposed to accurately simulate the different tissue types such as blood, fat, muscles, and bones in a 3D circuit model in addition to the pulsatile activity of the arteries through a variable impedance model. This circuit model is simulated in SPICE and can be used to guide design decisions (i.e. electrode placement relative to the artery and electrode configuration) to optimize the monitoring of pulse wave prior to experimentation. We present extensive simulations of the arterial pulse waveform for different sensor locations, electrode sizes, current injection frequencies, and artery depths. These simulations are validated by experimental Bio-Z measurements.


Assuntos
Análise de Onda de Pulso , Pulso Arterial , Impedância Elétrica , Eletrodos , Frequência Cardíaca
18.
Biosens Bioelectron ; 169: 112362, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32911314

RESUMO

Facing unprecedented population-ageing, the management of noncommunicable diseases (NCDs) urgently needs a point-of-care (PoC) testing infrastructure. Magnetic flow cytometers are one such solution for rapid cancer cellular detection in a PoC setting. In this work, we report a giant magnetoresistive spin-valve (GMR SV) biosensor array with a multi-stripe sensor geometry and matched filtering to improve detection accuracy without compromising throughput. The carefully designed sensor geometry generates a characteristic signature when cells labeled with magnetic nanoparticles (MNPs) pass by thus enabling multi-parametric measurement like optical flow cytometers (FCMs). Enumeration and multi-parametric information were successfully measured across two decades of throughput (37 - 2730 cells/min). 10-µm polymer microspheres were used as a biomimetic model where MNPs and MNP-decorated polymer conjugates were flown over the GMR SV sensor array and detected with a signal-to-noise ratio (SNR) as low as 2.5 dB due to the processing gain afforded by the matched filtering. The performance was compared against optical observation, exhibiting a 92% detection efficiency. The system achieved a 95% counting accuracy for biomimetic models and 98% for aptamer-based pancreatic cancer cell detection. This system demonstrates the ability to perform reliable flow cytometry toward PoC diagnostics to benefit NCD control plans.


Assuntos
Técnicas Biossensoriais , Citometria de Fluxo , Fenômenos Magnéticos , Magnetismo , Oligonucleotídeos
19.
Sci Rep ; 10(1): 7941, 2020 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-32409675

RESUMO

Proteases are enzymes that cleave proteins and are crucial to physiological processes such as digestion, blood clotting, and wound healing. Unregulated protease activity is a biomarker of several human diseases. Synthetic peptides that are selectively hydrolyzed by a protease of interest can be used as reporter substrates of unregulated protease activity. We developed an activity-based protease sensor by immobilizing magnetic nanoparticles (MNPs) to the surface of a giant magnetoresistive spin-valve (GMR SV) sensor using peptides. Cleavage of these peptides by a protease releases the magnetic nanoparticles resulting in a time-dependent change in the local magnetic field. Using this approach, we detected a significant release of MNPs after 3.5 minutes incubation using just 4 nM of the cysteine protease, papain. In addition, we show that proteases in healthy human urine do not release the MNPs, however addition of 20 nM of papain to the urine samples resulted in a time-dependent change in magnetoresistance. This study lays the foundation for using GMR SV sensors as a platform for real-time, quantitative detection of protease activity in biological fluids.


Assuntos
Técnicas Biossensoriais/métodos , Ensaios Enzimáticos/métodos , Fenômenos Magnéticos , Peptídeo Hidrolases/metabolismo , Sequência de Aminoácidos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Nanopartículas de Magnetita/química , Papaína/química , Papaína/metabolismo , Peptídeo Hidrolases/química , Peptídeos/química , Peptídeos/metabolismo , Propriedades de Superfície , Fatores de Tempo
20.
IEEE Trans Biomed Circuits Syst ; 13(6): 1254-1263, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31670677

RESUMO

Magnetic biosensing is an emerging technique for ultra-sensitive point-of-care (PoC) biomolecular detection. However, the large baseline-to-signal ratio and sensor-to-sensor mismatch in magnetoresistive (MR) biosensors severely complicates the design of the analog front-end (AFE) due to the high dynamic range (DR) required. The proposed AFE addresses these issues through new architectural and circuit level techniques including fast settling duty-cycle resistors (DCRs) to reduce readout time and a high frequency interference rejection (HFIR) sampling technique embedded in the ADC to relax the DR requirement. The AFE achieves an input-referred noise of 46.4 nT/√Hz, an input-referred baseline of less than 0.235 mT, and a readout time of 11 ms while consuming just 1.39 mW. Implemented in a 0.18 µm CMOS process, this work has state-of-the-art performance with 22.7× faster readout time, >7.8× lower baseline, and 2.3× lower power than previously reported MR sensor AFEs.


Assuntos
Imunoensaio/instrumentação , Magnetismo , Semicondutores , Amplificadores Eletrônicos , Técnicas Biossensoriais , Imunoensaio/métodos , Limite de Detecção , Sistemas Automatizados de Assistência Junto ao Leito , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...