Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38088778

RESUMO

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

2.
Phys Rev E ; 108(2): L023202, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37723759

RESUMO

In inertial confinement fusion (ICF) implosions, the interface between the cryogenic DT fuel and the ablator is unstable to shock acceleration (the Richtmyer-Meshkov instability, RM) and constant acceleration (Rayleigh-Taylor instability, RT). Instability growth at this interface can reduce the final compression, limiting fusion burnup. If the constant acceleration is in the direction of the lighter material (negative Atwood number), the RT instability produces oscillatory motion that can stabilize against RM growth. Theory and simulations suggest this scenario occurred at early times in some ICF experiments on the National Ignition Facility, possibly explaining their favorable performance compared to one-dimensional simulations. This characteristic is being included in newer, lower adiabat designs, seeking to improve compression while minimizing ablator mixing into the fuel.

3.
Rev Sci Instrum ; 93(12): 123902, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586918

RESUMO

This study investigates methods to optimize quasi-monochromatic, ∼10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 1015 W/cm2, optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. We discuss methods to optimize the source to maintain a uniform XRS for ∼10 ns, mitigating cold plasma and higher energy x-ray emission lines.

4.
Rev Sci Instrum ; 93(2): 023505, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35232158

RESUMO

A new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such a system, the Single Line Of Sight camera. The results of this characterization are used to benchmark particle-in-cell simulations of the electrons drifting inside the detector, which are found to well reproduce the experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insights into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory.

5.
Phys Rev Lett ; 129(27): 275001, 2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36638294

RESUMO

We present measurements of ice-ablator mix at stagnation of inertially confined, cryogenically layered capsule implosions. An ice layer thickness scan with layers significantly thinner than used in ignition experiments enables us to investigate mix near the inner ablator interface. Our experiments reveal for the first time that the majority of atomically mixed ablator material is "dark" mix. It is seeded by the ice-ablator interface instability and located in the relatively cooler, denser region of the fuel assembly surrounding the fusion hot spot. The amount of dark mix is an important quantity as it is thought to affect both fusion fuel compression and burn propagation when it turns into hot mix as the burn wave propagates through the initially colder fuel region surrounding an igniting hot spot. We demonstrate a significant reduction in ice-ablator mix in the hot-spot boundary region when we increase the initial ice layer thickness.

6.
Rev Sci Instrum ; 92(5): 053904, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243269

RESUMO

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

7.
Rev Sci Instrum ; 92(5): 053511, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243355

RESUMO

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 µm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 µm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh-Taylor instabilities with a measured resolution of under 3 µm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

8.
Phys Rev Lett ; 125(15): 155003, 2020 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-33095614

RESUMO

The implosion efficiency in inertial confinement fusion depends on the degree of stagnated fuel compression, density uniformity, sphericity, and minimum residual kinetic energy achieved. Compton scattering-mediated 50-200 keV x-ray radiographs of indirect-drive cryogenic implosions at the National Ignition Facility capture the dynamic evolution of the fuel as it goes through peak compression, revealing low-mode 3D nonuniformities and thicker fuel with lower peak density than simulated. By differencing two radiographs taken at different times during the same implosion, we also measure the residual kinetic energy not transferred to the hot spot and quantify its impact on the implosion performance.

9.
Rev Sci Instrum ; 90(1): 013702, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30709218

RESUMO

The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 µm, close to theoretical predictions. Finally, results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration.

10.
Rev Sci Instrum ; 87(11): 11E310, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910309

RESUMO

Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40-200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

11.
Rev Sci Instrum ; 87(11): 11E321, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910418

RESUMO

The high fuel capsule compression required for indirect drive inertial confinement fusion requires careful control of the X-ray drive symmetry throughout the laser pulse. When the outer cone beams strike the hohlraum wall, the plasma ablated off the hohlraum wall expands into the hohlraum and can alter both the outer and inner cone beam propagations and hence the X-ray drive symmetry especially at the final stage of the drive pulse. To quantitatively understand the wall motion, we developed a new experimental technique which visualizes the expansion and stagnation of the hohlraum wall plasma. Details of the experiment and the technique of spectrally selective x-ray imaging are discussed.

12.
Rev Sci Instrum ; 85(11): 11D608, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430184

RESUMO

A monochromatic X-ray backlighter based on Bragg reflection from a spherically bent quartz crystal has been developed for the MAGPIE pulsed power generator at Imperial College (1.4 MA, 240 ns) [I. H. Mitchell et al., Rev. Sci. Instrum. 67, 1533 (2005)]. This instrument has been used to diagnose high energy density physics experiments with 1.865 keV radiation (Silicon He-α) from a laser plasma source driven by a ∼7 J, 1 ns pulse from the Cerberus laser. The design of the diagnostic, its characterisation and performance, and initial results in which the instrument was used to radiograph a shock physics experiment on MAGPIE are discussed.

13.
Rev Sci Instrum ; 85(11): 11D623, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430199

RESUMO

Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., "AXIS: An instrument for imaging Compton radiographs using ARC on the NIF," Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.

14.
Rev Sci Instrum ; 85(11): 11D624, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430200

RESUMO

Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV-200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

15.
Rev Sci Instrum ; 85(11): 11E502, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430344

RESUMO

A suite of laser based diagnostics is used to study interactions of magnetised, supersonic, radiatively cooled plasma flows produced using the Magpie pulse power generator (1.4 MA, 240 ns rise time). Collective optical Thomson scattering measures the time-resolved local flow velocity and temperature across 7-14 spatial positions. The scattering spectrum is recorded from multiple directions, allowing more accurate reconstruction of the flow velocity vectors. The areal electron density is measured using 2D interferometry; optimisation and analysis are discussed. The Faraday rotation diagnostic, operating at 1053 nm, measures the magnetic field distribution in the plasma. Measurements obtained simultaneously by these diagnostics are used to constrain analysis, increasing the accuracy of interpretation.

16.
Phys Rev Lett ; 113(3): 035003, 2014 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-25083650

RESUMO

The interpenetration and interaction of supersonic, magnetized tungsten plasma flows has been directly observed via spatially and temporally resolved measurements of the Thomson scattering ion feature. A novel scattering geometry allows independent measurements of the axial and radial velocity components of the ions. The plasma flows are produced via the pulsed power driven ablation of fine tungsten wires in a cylindrical wire array z pinch. Fits of the data reveal the variations in radial velocity, axial velocity, and temperature of the ion streams as they interpenetrate and interact. A previously unobserved increase in axial velocity is measured near the array axis. This may be the result of v[over →]×B[over →] bending of the ion streams by a toroidal magnetic field, advected to and accumulated about the axis by the streams.

17.
Phys Rev Lett ; 108(14): 145002, 2012 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-22540799

RESUMO

A Thomson scattering diagnostic has been used to measure the parameters of cylindrical wire array Z pinch plasmas during the ablation phase. The scattering operates in the collective regime (α>1) allowing spatially localized measurements of the ion or electron plasma temperatures and of the plasma bulk velocity. The ablation flow is found to accelerate towards the axis reaching peak velocities of 1.2-1.3×10(7) cm/s in aluminium and ∼1×10(7) cm/s in tungsten arrays. Precursor ion temperature measurements made shortly after formation are found to correspond to the kinetic energy of the converging ablation flow.

18.
Phys Rev Lett ; 106(20): 205002, 2011 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-21668237

RESUMO

A new wire array configuration has been used to create thin shell-like implosions in a cylindrical array. The setup introduces a ~5 kA, ~25 ns current prepulse followed by a ~140 ns current-free interval before the application of the main (~1 MA) current pulse. The prepulse volumetrically heats the wires which expand to ~1 mm diameter leaving no dense wire core and without development of instabilities. The main current pulse then ionizes all the array mass resulting in suppression of the ablation phase, an accelerating implosion, and no trailing mass. Rayleigh-Taylor instability growth in the imploding plasma is inferred to be seeded by µm-scale perturbations on the surface of the wires. The absence of wire cores is found to be the critical factor in altering the implosion dynamics.

19.
Phys Rev Lett ; 100(6): 065003, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18352483

RESUMO

A new wire-array configuration has been used to control the modulation of ablated plasma flow for the first time. Cylindrical aluminum coiled arrays, in which each straight wire is replaced with a single helix, were driven by a 1 MA, 240 ns current pulse. Ablated plasma is directed away from the coiled wire cores in a manner that can be understood in terms of Lorentz forces that arise from a complex current path modeled by 3D magnetohydrodynamic simulations. Outside the diameter of the helix, the flow of ablated plasma is axially modulated at the wavelength of the coil.

20.
Phys Rev Lett ; 100(3): 035001, 2008 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-18232988

RESUMO

The first laboratory astrophysics experiments to produce a radiatively cooled plasma jet with dynamically significant angular momentum are discussed. A new configuration of wire array z pinch, the twisted conical wire array, is used to produce convergent plasma flows each rotating about the central axis. Collision of the flows produces a standing shock and jet that each have supersonic azimuthal velocities. By varying the twist angle of the array, the rotation velocity of the system can be controlled, with jet rotation velocities reaching approximately 18% of the propagation velocity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...