Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Phys Med Biol ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38604190

RESUMO

Objective Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels. Method The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different size extension rings to mimic a small- and medium-sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error (RMSE), structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image. Results DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25-83% in the small phantom and by 50-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR. Conclusion DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose, which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.

2.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386967

RESUMO

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Obesidade , Ferro
3.
J Cardiovasc Comput Tomogr ; 18(1): 50-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38314547

RESUMO

BACKGROUND: Computed tomography aortic valve calcium (AVC) score has accepted value for diagnosing and predicting outcomes in aortic stenosis (AS). Multi-energy CT (MECT) allows virtual non-contrast (VNC) reconstructions from contrast scans. We aim to compare the VNC-AVC score to the true non-contrast (TNC)-AVC score for assessing AS severity. METHODS: We prospectively included patients undergoing a MECT for transcatheter aortic valve replacement (TAVR) planning. TNC-AVC was acquired before contrast, and VNC-AVC was derived from a retrospectively gated contrast-enhanced scan. The Agatston scoring method was used for quantification, and linear regression analysis to derive adjusted-VNC values. RESULTS: Among 109 patients (55% female) included, 43% had concordant severe and 14% concordant moderate AS. TNC scan median dose-length product was 116 â€‹mGy∗cm. The median TNC-AVC was 2,107 AU (1,093-3,372), while VNC-AVC was 1,835 AU (1293-2,972) after applying the coefficient (1.46) and constant (743) terms. A strong correlation was demonstrated between methods (r â€‹= â€‹0.93; p â€‹< â€‹0.001). Using accepted thresholds (>1,300 AU for women and >2,000 AU for men), 65% (n â€‹= â€‹71) of patients had severe AS by TNC-AVC and 67% (n â€‹= â€‹73) by adjusted-VNC-AVC. After estimating thresholds for adjusted-VNC (>1,564 AU for women and >2,375 AU for men), 56% (n â€‹= â€‹61) had severe AS, demonstrating substantial agreement with TNC-AVC (κ â€‹= â€‹0.77). CONCLUSIONS: MECT-derived VNC-AVC showed a strong correlation with TNC-AVC. After adjustment, VNC-AVC demonstrated substantial agreement with TNC-AVC, potentially eliminating the requirement for an additional scan and enabling reductions in both radiation exposure and acquisition time.


Assuntos
Estenose da Valva Aórtica , Tomografia Computadorizada por Raios X , Masculino , Humanos , Feminino , Estudos Retrospectivos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Cálcio
4.
medRxiv ; 2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38106064

RESUMO

Objective: Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels. Approach: The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different sized extension rings to mimic a small and medium sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error (RMSE), structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image. Main Results: DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25-83% in the small phantom and by 50-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR with a non-anatomical physics phantom. Significance: DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.

5.
Quant Imaging Med Surg ; 13(2): 924-934, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36819257

RESUMO

Background: To determine the spectral accuracy in detector-based dual-energy CT (DECT) at 100 kVp and wide (8 cm) collimation width for dose levels and object sizes relevant to pediatric imaging. Methods: A spectral CT phantom containing tissue-equivalent materials and iodine inserts of varying concentrations was scanned on the latest generation detector-based DECT system. Two 3D-printed extension rings were used to mimic varying pediatric patient sizes. Scans were performed at 100 and 120 kVp, 4 and 8 cm collimation widths, and progressively reduced radiation dose levels, down to 0.9 mGy CTDIvol. Virtual mono-energetic, iodine density, effective atomic number, and electron density results were quantified and compared to their expected values for all acquisition settings and phantom sizes. Results: DECT scans at 100 kVp provided highly accurate spectral results; however, a size dependence was observed for iodine quantification. For the medium phantom configuration (15 cm diameter), measurement errors in iodine density, effective atomic number, and electron density (ED) were below 0.3 mg/mL, 0.2 and 1.8 %EDwater, respectively. The average accuracy was slightly different from scans at 120 kVp; however, not statistically significant for all configurations. Collimation width had no substantial impact. Spectral results were accurate and reliable for radiation exposures down to 0.9 mGy CTDIvol. Conclusions: Detector-based DECT at 100 kVp can provide on-demand or retrospective spectral information with high accuracy even at extremely low doses, thereby making it an attractive solution for pediatric imaging.

6.
J Comput Assist Tomogr ; 45(1): 24-28, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32168080

RESUMO

OBJECTIVE: The aim of this study was to investigate if Hounsfield unit (HU) values from virtual noncontrast (VNC) images derived from portal venous phase spectral-detector computed tomography can help to differentiate adrenal adenomas and metastases. METHODS: Spectral-detector computed tomography datasets of 33 patients with presence of adrenal lesions and standard of reference for lesion origin by follow-up/prior examinations or dedicated magnetic resonance imaging were included. Conventional and VNC images were reconstructed from the same scan. Region of interest-based image analysis was performed in adrenal lesions and contralateral healthy adrenal tissue. RESULTS: The 33 lesions consisted of 23 adenomas and 10 metastases. Hounsfield unit values of all lesions in VNC images were significantly lower compared with conventional images (18.2 ± 12.6 HU vs 59.6 ± 21.7 HU, P < 0.001). Hounsfield unit values in adenomas were significantly lower in VNC images (11.3 ± 6.5 HU vs 34.1 ± 9.1 HU, P < 0.001). CONCLUSIONS: Virtual noncontrast HU values differed significantly between adrenal adenomas and metastases and can therefore be used for improved characterization of incidental adrenal lesions and definition of adrenal adenomas.


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/secundário , Glândulas Suprarrenais/patologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adenoma/patologia , Neoplasias das Glândulas Suprarrenais/patologia , Glândulas Suprarrenais/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Interface Usuário-Computador
7.
Plast Reconstr Surg ; 147(1): 49-55, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33002983

RESUMO

BACKGROUND: Neck fat distribution plays an important role in aging, yet how fat distribution changes with age is largely unknown. This study used volumetric computed tomography in live patients to characterize neck fat volume and distribution in young and elderly women. METHODS: A retrospective analysis was conducted of head and neck computed tomographic angiographs of 20 young (aged 20 to 35 years) and 20 old (aged 65 to 89 years) women. Fat volume in the supraplatysmal and subplatysmal planes was quantified. Distribution of fat volume was assessed by dividing each supraplatysmal and subplatysmal compartment into upper, middle, and lower thirds. RESULTS: Total supraplatysmal fat volume was greater than subplatysmal in all patients. Young patients had more total supraplatysmal fat than old patients (p < 0.0001). No difference was found between age groups in subplatysmal fat (p > 0.05). No difference was found between upper/middle/lower third supraplatysmal fat volumes in young patients. When comparing supraplatysmal thirds within the elderly population, the middle third fat volume (28.58 ± 20.01 cm3) was greater than both upper (18.93 ± 10.35 cm3) and lower thirds (15.46 ± 11.57 cm3) (p < 0.01). CONCLUSIONS: This study suggests that total supraplatysmal fat volume decreases with age. Older patients had more fat volume in the upper and middle thirds compared with the lower third of the supraplatysmal fat compartment, whereas young patients had more evenly distributed fat. These results suggest that fat deposition and redistribution in the neck occur with age and may be a contributing factor to the obtuse cervicomandibular angle of the elderly.


Assuntos
Adiposidade/fisiologia , Envelhecimento/fisiologia , Gordura Subcutânea/diagnóstico por imagem , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Pescoço , Estudos Retrospectivos , Gordura Subcutânea/irrigação sanguínea , Gordura Subcutânea/fisiologia , Adulto Jovem
8.
Med Phys ; 47(7): e881-e912, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32215937

RESUMO

In x-ray computed tomography (CT), materials with different elemental compositions can have identical CT number values, depending on the mass density of each material and the energy of the detected x-ray beam. Differentiating and classifying different tissue types and contrast agents can thus be extremely challenging. In multienergy CT, one or more additional attenuation measurements are obtained at a second, third or more energy. This allows the differentiation of at least two materials. Commercial dual-energy CT systems (only two energy measurements) are now available either using sequential acquisitions of low- and high-tube potential scans, fast tube-potential switching, beam filtration combined with spiral scanning, dual-source, or dual-layer detector approaches. The use of energy-resolving, photon-counting detectors is now being evaluated on research systems. Irrespective of the technological approach to data acquisition, all commercial multienergy CT systems circa 2020 provide dual-energy data. Material decomposition algorithms are then used to identify specific materials according to their effective atomic number and/or to quantitate mass density. These algorithms are applied to either projection or image data. Since 2006, a number of clinical applications have been developed for commercial release, including those that automatically (a) remove the calcium signal from bony anatomy and/or calcified plaque; (b) create iodine concentration maps from contrast-enhanced CT data and/or quantify absolute iodine concentration; (c) create virtual non-contrast-enhanced images from contrast-enhanced scans; (d) identify perfused blood volume in lung parenchyma or the myocardium; and (e) characterize materials according to their elemental compositions, which can allow in vivo differentiation between uric acid and non-uric acid urinary stones or uric acid (gout) or non-uric acid (calcium pyrophosphate) deposits in articulating joints and surrounding tissues. In this report, the underlying physical principles of multienergy CT are reviewed and each of the current technical approaches are described. In addition, current and evolving clinical applications are introduced. Finally, the impact of multienergy CT technology on patient radiation dose is summarized.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Imagens de Fantasmas , Fótons , Raios X
9.
Med Phys ; 46(11): 5216-5226, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31442300

RESUMO

PURPOSE: Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners incorporating novel design features. We aimed to compare radiation dose estimates from MC simulation to doses measured in physical anthropomorphic phantoms using metal-oxide semiconductor field-effect transistors (MOSFETs) in a 256-slice CT scanner. METHODS: Fifty MOSFETs were placed in organs within tissue-equivalent anthropomorphic adult and pediatric radiographic phantoms, which were scanned using a variety of chest, cardiac, abdomen, brain, and whole-body protocols on a 256-slice system. MC computations were performed on voxelized CT reconstructions of the phantoms using a highly parallel MC tool developed specifically for diagnostic X-ray energies and rapid computation. Doses were compared between MC estimates and physical measurements. RESULTS: The average ratio of MOSFET to MC dose in the in-field region was close to 1 (range, 0.96-1.12; mean ± SD, 1.01 ± 0.04), indicating outstanding agreement between measured and simulated doses. The difference between measured and simulated doses tended to increase with distance from the in-field region. The error in the MC simulations due to the limited number of simulated photons was less than 1%. The errors in the MOSFET dose determinations in the in-field region for a single scan were mainly due to the calibration method and were typically about 6% (8% if the error in the reading of the ionization chamber that was used for the MOSFET calibration was included). CONCLUSIONS: Radiation dose estimation using a highly parallelized MC method is strongly correlated with experimental measurements in physical adult and infant anthropomorphic phantoms for a wide range of scans performed on a 256-slice CT scanner. Incorporation into CT scanners of radiation-dose distribution estimation, employing the scanner's reconstructed images of the patient, may offer the potential for accurate patient-specific CT dosimetry.


Assuntos
Metais/química , Método de Monte Carlo , Óxidos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Transistores Eletrônicos , Adulto , Calibragem , Humanos , Radiometria , Imagem Corporal Total
10.
Phys Med Biol ; 63(2): 025027, 2018 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-29185436

RESUMO

This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital's clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm-1. NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Humanos , Iodo , Razão Sinal-Ruído
11.
JACC Cardiovasc Imaging ; 11(1): 64-74, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28823748

RESUMO

OBJECTIVES: This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy-1cm-1. BACKGROUND: Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. METHODS: Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. RESULTS: k-Factors averaged 0.026 mSv·mGy-1cm-1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy-1cm-1. The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy-1cm-1). CONCLUSIONS: Cardiac k-factors for all scanners and protocols are considerably higher than the k-factor currently used to estimate ED of cardiac CT studies, suggesting that radiation doses from cardiac CT have been significantly and systematically underestimated. Using cardiac-specific factors can more accurately inform the benefit-risk calculus of cardiac-imaging strategies.


Assuntos
Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Tomógrafos Computadorizados , Calcificação Vascular/diagnóstico por imagem , Simulação por Computador , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Valor Preditivo dos Testes
12.
Cardiovasc Diagn Ther ; 7(5): 527-538, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29255694

RESUMO

Non-linear iterative reconstruction (IR) algorithms have been increasingly incorporated into clinical cardiac CT protocols at institutions around the world. Multiple IR algorithms are available commercially from various vendors. IR algorithms decrease image noise and are primarily used to enable lower radiation dose protocols. IR can also be used to improve image quality for imaging of obese patients, coronary atherosclerotic plaques, coronary stents, and myocardial perfusion. In this article, we will review the various applications of IR algorithms in cardiac imaging and evaluate how they have changed practice.

13.
Radiographics ; 37(7): 1955-1974, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29131773

RESUMO

Advances in scanner technology enabling shorter scan times, improvements in spatial and temporal resolution, and more dose-efficient data reconstruction coupled with rapidly growing evidence from clinical trials have established computed tomography (CT) as an important imaging modality in the evaluation of cardiovascular disorders. Multienergy (or spectral or dual-energy) CT is a relatively recent advance in which attenuation data from different energies are used to characterize materials beyond what is possible at conventional CT. Current technologies for multienergy CT are either source based (ie, dual source, rapid kilovoltage switching, dual spin, and split beam) or detector based (ie, dual layer and photon counting), and material-based decomposition occurs in either image or projection space. In addition to conventional diagnostic images, multienergy CT provides image sets such as iodine maps, virtual nonenhanced, effective atomic number, and virtual monoenergy (VM) images as well as data at the elemental level (CT fingerprinting), which can complement and in some areas overcome the limitations posed by conventional CT methods. In myocardial perfusion imaging, iodine maps improve the sensitivity of perfusion defects, and VM images improve the specificity by decreasing artifacts. Iodine maps are also useful in improving the performance of CT in delayed-enhancement imaging. In pulmonary perfusion imaging, iodine maps enhance the sensitivity of detection of both acute and chronic pulmonary emboli. Low-energy (as measured in kiloelectron volts) VM images allow enhancement of vascular contrast, which can either be used to lower contrast dose or salvage a suboptimal contrast-enhanced study. High-energy VM images can be used to decrease or eliminate artifacts such as beam-hardening and metallic artifacts. Virtual nonenhanced images have similar attenuation as true nonenhanced images and help in reducing radiation dose by eliminating the need for the latter in multiphasic vascular studies. Other potential applications of multienergy CT include calcium scoring from virtual nonenhanced images created from coronary CT angiograms and myocardial iron quantification. Online supplemental material is available for this article. ©RSNA, 2017.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador
14.
Med Phys ; 44(12): 6589-6602, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28940306

RESUMO

PURPOSE: Metal-oxide-semiconductor field-effect transistors (MOSFETs) serve as a helpful tool for organ radiation dosimetry and their use has grown in computed tomography (CT). While different approaches have been used for MOSFET calibration, those using the commonly available 100 mm pencil ionization chamber have not incorporated measurements performed throughout its length, and moreover, no previous work has rigorously evaluated the multiple sources of error involved in MOSFET calibration. In this paper, we propose a new MOSFET calibration approach to translate MOSFET voltage measurements into absorbed dose from CT, based on serial measurements performed throughout the length of a 100-mm ionization chamber, and perform an analysis of the errors of MOSFET voltage measurements and four sources of error in calibration. METHODS: MOSFET calibration was performed at two sites, to determine single calibration factors for tube potentials of 80, 100, and 120 kVp, using a 100-mm-long pencil ion chamber and a cylindrical computed tomography dose index (CTDI) phantom of 32 cm diameter. The dose profile along the 100-mm ion chamber axis was sampled in 5 mm intervals by nine MOSFETs in the nine holes of the CTDI phantom. Variance of the absorbed dose was modeled as a sum of the MOSFET voltage measurement variance and the calibration factor variance, the latter being comprised of three main subcomponents: ionization chamber reading variance, MOSFET-to-MOSFET variation and a contribution related to the fact that the average calibration factor of a few MOSFETs was used as an estimate for the average value of all MOSFETs. MOSFET voltage measurement error was estimated based on sets of repeated measurements. The calibration factor overall voltage measurement error was calculated from the above analysis. RESULTS: Calibration factors determined were close to those reported in the literature and by the manufacturer (~3 mV/mGy), ranging from 2.87 to 3.13 mV/mGy. The error σV of a MOSFET voltage measurement was shown to be proportional to the square root of the voltage V: σV=cV where c = 0.11 mV. A main contributor to the error in the calibration factor was the ionization chamber reading error with 5% error. The usage of a single calibration factor for all MOSFETs introduced an additional error of about 5-7%, depending on the number of MOSFETs that were used to determine the single calibration factor. The expected overall error in a high-dose region (~30 mGy) was estimated to be about 8%, compared to 6% when an individual MOSFET calibration was performed. For a low-dose region (~3 mGy), these values were 13% and 12%. CONCLUSIONS: A MOSFET calibration method was developed using a 100-mm pencil ion chamber and a CTDI phantom, accompanied by an absorbed dose error analysis reflecting multiple sources of measurement error. When using a single calibration factor, per tube potential, for different MOSFETs, only a small error was introduced into absorbed dose determinations, thus supporting the use of a single calibration factor for experiments involving many MOSFETs, such as those required to accurately estimate radiation effective dose.


Assuntos
Metais/química , Óxidos/química , Radiometria/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Transistores Eletrônicos , Calibragem , Projetos de Pesquisa
15.
Diagn Interv Radiol ; 23(3): 187-193, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28302592

RESUMO

Spectral detector computed tomography (SDCT) is a novel technology that uses two layers of detectors to simultaneously collect low and high energy data. Spectral data is used to generate conventional polyenergetic images as well as dedicated spectral images including virtual monoenergetic and material composition (iodine-only, virtual unenhanced, effective atomic number) images. This paper provides an overview of SDCT technology and a description of some spectral image types. The potential utility of SDCT for cardiovascular imaging and the impact of this new technology on radiation and contrast dose are discussed through presentation of initial patient studies performed on a SDCT scanner. The value of SDCT for salvaging suboptimal studies including those with poor contrast-enhancement or beam hardening artifacts through retrospective reconstruction of spectral data is discussed. Additionally, examples of specific benefits for the evaluation of aortic disease, imaging before transcatheter aortic valve implantation, evaluation of pulmonary veins pre- and post-pulmonary radiofrequency ablation, evaluation of coronary artery lumen, assessment of myocardial perfusion, detection of pulmonary embolism, and characterization of incidental findings are presented.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/instrumentação , Embolia Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Doenças da Aorta/cirurgia , Ablação por Cateter/métodos , Humanos , Imagem de Perfusão do Miocárdio/métodos , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
16.
Radiographics ; 36(7): 2064-2083, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27768543

RESUMO

Computed tomography is vulnerable to a wide variety of artifacts, including patient- and technique-specific artifacts, some of which are unique to imaging of the heart. Motion is the most common source of artifacts and can be caused by patient, cardiac, or respiratory motion. Cardiac motion artifacts can be reduced by decreasing the heart rate and variability and the duration of data acquisition; adjusting the placement of the data window within a cardiac cycle; performing single-heartbeat scanning; and using multisegment reconstruction, motion-correction algorithms, and electrocardiographic editing. Respiratory motion artifacts can be minimized with proper breath holding and shortened scan duration. Partial volume averaging is caused by the averaging of attenuation values from all tissue contained within a voxel and can be reduced by improving the spatial resolution, using a higher x-ray energy, or displaying images with a wider window width. Beam-hardening artifacts are caused by the polyenergetic nature of the x-ray beam and can be reduced by using x-ray filtration, applying higher-energy x-rays, altering patient position, modifying contrast material protocols, and applying certain reconstruction algorithms. Metal artifacts are complex and have multiple causes, including x-ray scatter, underpenetration, motion, and attenuation values that exceed the typical dynamic range of Hounsfield units. Quantum mottle or noise is caused by insufficient penetration of tissue and can be improved by increasing the tube current or peak tube potential, reconstructing thicker sections, increasing the rotation time, using appropriate patient positioning, and applying iterative reconstruction algorithms. ©RSNA, 2016.


Assuntos
Artefatos , Técnicas de Imagem Cardíaca/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Erros de Diagnóstico/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Medicina Baseada em Evidências , Humanos , Movimento (Física) , Próteses e Implantes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Am J Cardiol ; 118(10): 1480-1485, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27642113

RESUMO

The 2013 American College of Cardiology/American Heart Association cardiovascular prevention guidelines use a new pooled cohort equation (PCE) to predict 10-year risk of atherosclerotic cardiovascular disease (ASCVD) events which form the basis of treatment recommendations. Coronary artery calcium score (CACS) has been proposed as a means to assess atherosclerotic risk. We sought to study the level of agreement in predicted ASCVD risk by CACS and PCE-calculated models and the potential impact on therapy of additional CACS testing. We studied 687 treatment naive, consecutive patients (mean age 53.5 years, 72% men) who had a CACS study at our institution. Clinical and imaging data were recorded. ASCVD risk was calculated using the published PCE-based algorithm. CACS-based risk was categorized by previously published recommendations. Risk stratification comparisons were made and level of agreement calculated. In the cohort, mean ASCVD PCE-calculated risk was 5.3 ± 5.2% and mean CACS was 80 ± 302 Agatston units (AU). Of the intermediate PCE-calculated risk (5% to <7.5%) cohort, 85% had CACS <100 AU. Of the cohort categorized as reasonable to treat per the ASCVD prevention guidelines, 40% had a CACS of 0 AU and an additional 44% had CACS >0 but <100 AU. The level of agreement between the new PCE model of ASCVD risk and demonstrable coronary artery calcium is low. CACS testing may be most beneficial in those with an intermediate risk of ASCVD (PCE-calculated risk of 5% to <7.5%) where, in approximately half of patients, CACS testing significantly refined risk assessment primarily into a very low-risk category.


Assuntos
American Heart Association , Aterosclerose/prevenção & controle , Cálcio/metabolismo , Cardiologia , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Guias de Prática Clínica como Assunto , Adulto , Idoso , Aterosclerose/epidemiologia , Aterosclerose/metabolismo , Vasos Coronários/metabolismo , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade/tendências , Curva ROC , Estudos Retrospectivos , Medição de Risco/métodos , Estados Unidos/epidemiologia , Adulto Jovem
18.
J Cardiovasc Comput Tomogr ; 10(5): 364-74, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27475972

RESUMO

Transcatheter aortic valve replacement (TAVR) is performed frequently in patients with severe, symptomatic aortic stenosis who are at high risk or inoperable for open surgical aortic valve replacement. Computed tomography angiography (CTA) has become the gold standard imaging modality for pre-TAVR cardiac anatomic and vascular access assessment. Traditionally, cardiac CTA has been most frequently used for assessment of coronary artery stenosis, and scanning protocols have generally been tailored for this purpose. Pre-TAVR CTA has different goals than coronary CTA and the high prevalence of chronic kidney disease in the TAVR patient population creates a particular need to optimize protocols for a reduction in iodinated contrast volume. This document reviews details which allow the physician to tailor CTA examinations to maximize image quality and minimize harm, while factoring in multiple patient and scanner variables which must be considered in customizing a pre-TAVR protocol.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Implante de Prótese de Valva Cardíaca , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/instrumentação , Meios de Contraste/administração & dosagem , Angiografia Coronária/efeitos adversos , Angiografia Coronária/instrumentação , Eletrocardiografia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Tomógrafos Computadorizados
19.
J Cardiovasc Comput Tomogr ; 10(3): 265-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26853972

RESUMO

BACKGROUND: Estimates of effective dose (E) for cardiovascular CT are obtained from a scanner-provided dose metric, the dose-length product (DLP), and a conversion factor. These estimates may not adequately represent the risk of a specific scan to obese adults. OBJECTIVE: Our objective was to create dose maps sensitive to patient size and anatomy in the irradiated region from a patient's own CT images and compare measured E (EDoseMap) to doses determined from standard DLP conversion (EDLP) in obese adults. METHODS: 21 obese patients (mean body mass index, 39 kg/m(2)) underwent CT of the pulmonary veins, thoracic aorta, or coronary arteries. DLP values were converted to E. A Monte Carlo tool was used to simulate X-ray photon interaction with virtual phantoms created from each patient's image set. Organ doses were determined from dose maps. EDoseMap was computed as a weighted sum of organ doses multiplied by tissue-weighting factors. RESULTS: EDLP (mean ± SD, 5.7 ± 3.3 mSv) was larger than EDoseMap (3.4 ± 2.4 mSv) (difference = 2.3; P < .001). CONCLUSION: Dose maps derived from patient CT images yielded lower effective doses than DLP conversion methods. Considering over all patient size, organ size, and tissue composition could lead to better dose metrics for obese patients.


Assuntos
Aortografia/métodos , Doenças Cardiovasculares/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Tomografia Computadorizada Multidetectores , Obesidade/complicações , Modelagem Computacional Específica para o Paciente , Flebografia/métodos , Doses de Radiação , Aorta Torácica/diagnóstico por imagem , Índice de Massa Corporal , Doenças Cardiovasculares/complicações , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/instrumentação , Vasos Coronários/diagnóstico por imagem , Humanos , Método de Monte Carlo , Tomografia Computadorizada Multidetectores/instrumentação , Obesidade/diagnóstico , Imagens de Fantasmas , Flebografia/instrumentação , Projetos Piloto , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos
20.
J Cardiovasc Comput Tomogr ; 10(2): 156-61, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26857422

RESUMO

OBJECTIVE: Cardiac resynchronization therapy (CRT) is an important therapeutic strategy in heart failure. However, there is a high incidence of lead implantation failure and suboptimal response, particularly in ischemic cardiomyopathy. This failure rate may partly be secondary to lack of suitable coronary sinus branches for lead implantation. We sought to assess the presence of coronary sinus (CS) tributaries in patients with ischemic and non-ischemic cardiomyopathy. MATERIALS AND METHODS: Multidetector computed tomography (MDCT) was performed in 100 patients: 25 coronary artery bypass graft (CABG) patients with impaired left ventricular ejection fraction (LVEF), 25 CABG patients with preserved LVEF, 25 patients with non-ischemic cardiomyopathy, and 25 controls. The presence of the CS and its tributaries, including the posterior interventricular vein (PIV), posterolateral vein (PLV), left marginal vein (LMV), and the anterior interventricular vein (AIV) was assessed. RESULTS: The CS, PIV, and AIV were demonstrated in all patients, whereas presence of a PLV and LMV was identified in 68% and 48% of CABG patients with impaired LVEF, 96% and 68% of CABG patients with preserved LVEF, 92% and 80% of patients with non-ischemic cardiomyopathy, and 100% and 80% of controls (p = 0.001 and 0.046 for PLV and LMV, respectively). CONCLUSIONS: This is the first report to demonstrate that the posterolateral vein and left middle vein, branches of the coronary sinus, are detectable in a significantly smaller number of CABG patients with impaired LVEF compared to controls, CABG with preserved LVEF, and non-ischemic cardiomyopathy. The absence of CS tributary veins in ischemic cardiomyopathy potentially hinders proper lead implantation and results in suboptimal CRT response.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Seio Coronário/diagnóstico por imagem , Anomalias dos Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Isquemia Miocárdica/diagnóstico por imagem , Flebografia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Ponte de Artéria Coronária , Seio Coronário/anormalidades , Anomalias dos Vasos Coronários/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...