Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 218
Filtrar
1.
Eur J Radiol ; 175: 111454, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38598964

RESUMO

OBJECTIVES: To evaluate the additional diagnostic benefit of diffusion weighted imaging (DWI) and contrast enhanced (CE) images during MR enterography (MRE) of Crohn's disease. METHODS: Datasets from 73 patients (mean age 32; 40 male) (28 new-diagnosis, 45 relapsed) were read independently by two radiologists selected from a pool of 13. Radiologists interpreted datasets using three sequential sequence blocks: (1) T2 weighted and steady state free precession gradient echo (SSFP) images alone (T2^); (2) T2 weighted and SSFP images with DWI (T2 + DWI^) and; (3) T2 weighted images, SSFP, DWI and post-contrast enhanced (CE) T1 images (T2 + DWI + CE^), documenting presence, location, and activity of small bowel disease. For each sequence block, sensitivity and specificity (readers combined) was calculated against an outcome-based construct reference standard. RESULTS: 59/73 patients had small bowel disease. Per-patient sensitivity for disease detection was essentially identical (80 % [95 % CI 72, 86], 81 % [73,87], and 79 % [71,86] for T2^, T2 + DWI^and T2 + DWI + CE^respectively). Specificity was identical (82 % [64 to 92]). Per patient sensitivity for disease extent was 56 % (47,65), 56 % (47,65) and 52 % (43 to 61) respectively, and specificity was 82 % (64 to 92) for all blocks. Sensitivity for active disease was 97 % (90,99), 97 % (90,99) and 98 % (92,99), and specificity was also comparable between all sequence combination reads. Results were consistent across segments and newly diagnosed/relapse patients. CONCLUSION: There is no additional diagnostic benefit of adding either DWI or CE to T2 FSE and SSFP sequences for evaluating small bowel Crohn's disease, suggesting MRE protocols can be simplified safely.

2.
Eur Radiol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488970

RESUMO

BACKGROUND: The Paris classification categorises colorectal polyp morphology. Interobserver agreement for Paris classification has been assessed at optical colonoscopy (OC) but not CT colonography (CTC). We aimed to determine the following: (1) interobserver agreement for the Paris classification using CTC between radiologists; (2) if radiologist experience influenced classification, gross polyp morphology, or polyp size; and (3) the extent to which radiologist classifications agreed with (a) colonoscopy and (b) a combined reference standard. METHODS: Following ethical approval for this non-randomised prospective cohort study, seven radiologists from three hospitals classified 52 colonic polyps using the Paris system. We calculated interobserver agreement using Fleiss kappa and mean pairwise agreement (MPA). Absolute agreement was calculated between radiologists; between CTC and OC; and between CTC and a combined reference standard using all available imaging, colonoscopic, and histopathological data. RESULTS: Overall interobserver agreement between the seven readers was fair (Fleiss kappa 0.33; 95% CI 0.30-0.37; MPA 49.7%). Readers with < 1500 CTC experience had higher interobserver agreement (0.42 (95% CI 0.35-0.48) vs. 0.33 (95% CI 0.25-0.42)) and MPA (69.2% vs 50.6%) than readers with ≥ 1500 experience. There was substantial overall agreement for flat vs protuberant polyps (0.62 (95% CI 0.56-0.68)) with a MPA of 87.9%. Agreement between CTC and OC classifications was only 44%, and CTC agreement with the combined reference standard was 56%. CONCLUSION: Radiologist agreement when using the Paris classification at CT colonography is low, and radiologist classification agrees poorly with colonoscopy. Using the full Paris classification in routine CTC reporting is of questionable value. CLINICAL RELEVANCE STATEMENT: Interobserver agreement for radiologists using the Paris classification to categorise colorectal polyp morphology is only fair; routine use of the full Paris classification at CT colonography is questionable. KEY POINTS: • Overall interobserver agreement for the Paris classification at CT colonography (CTC) was only fair, and lower than for colonoscopy. • Agreement was higher for radiologists with < 1500 CTC experience and for larger polyps. There was substantial agreement when classifying polyps as protuberant vs flat. • Agreement between CTC and colonoscopic polyp classification was low (44%).

4.
Eur Radiol ; 34(1): 455-464, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37526665

RESUMO

OBJECTIVES: The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS: We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS: The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Íleo/diagnóstico por imagem , Íleo/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
5.
Eur Radiol ; 34(4): 2524-2533, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37696974

RESUMO

OBJECTIVES: Prognostic and diagnostic models must work in their intended clinical setting, proven via "external evaluation", preferably by authors uninvolved with model development. By systematic review, we determined the proportion of models published in high-impact radiological journals that are evaluated subsequently. METHODS: We hand-searched three radiological journals for multivariable diagnostic/prognostic models 2013-2015 inclusive, developed using regression. We assessed completeness of data presentation to allow subsequent external evaluation. We then searched literature to August 2022 to identify external evaluations of these index models. RESULTS: We identified 98 index studies (73 prognostic; 25 diagnostic) describing 145 models. Only 15 (15%) index studies presented an evaluation (two external). No model was updated. Only 20 (20%) studies presented a model equation. Just 7 (15%) studies developing Cox models presented a risk table, and just 4 (9%) presented the baseline hazard. Two (4%) studies developing non-Cox models presented the intercept. Just 20 (20%) articles presented a Kaplan-Meier curve of the final model. The 98 index studies attracted 4224 citations (including 559 self-citations), median 28 per study. We identified just six (6%) subsequent external evaluations of an index model, five of which were external evaluations by researchers uninvolved with model development, and from a different institution. CONCLUSIONS: Very few prognostic or diagnostic models published in radiological literature are evaluated externally, suggesting wasted research effort and resources. Authors' published models should present data sufficient to allow external evaluation by others. To achieve clinical utility, researchers should concentrate on model evaluation and updating rather than continual redevelopment. CLINICAL RELEVANCE STATEMENT: The large majority of prognostic and diagnostic models published in high-impact radiological journals are never evaluated. It would be more efficient for researchers to evaluate existing models rather than practice continual redevelopment. KEY POINTS: • Systematic review of highly cited radiological literature identified few diagnostic or prognostic models that were evaluated subsequently by researchers uninvolved with the original model. • Published radiological models frequently omit important information necessary for others to perform an external evaluation: Only 20% of studies presented a model equation or nomogram. • A large proportion of research citing published models focuses on redevelopment and ignores evaluation and updating, which would be a more efficient use of research resources.


Assuntos
Publicações Periódicas como Assunto , Humanos , Prognóstico , Modelos de Riscos Proporcionais , Radiografia , Nomogramas
6.
Adv Sci (Weinh) ; 11(10): e2306246, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38145968

RESUMO

Protein-based biomaterial use is expanding within medicine, together with the demand to visualize their placement and behavior in vivo. However, current medical imaging techniques struggle to differentiate between protein-based implants and surrounding tissue. Here a fast, simple, and translational solution for tracking transplanted protein-based scaffolds is presented using X-ray CT-facilitating long-term, non-invasive, and high-resolution imaging. X-ray visible scaffolds are engineered by selectively iodinating tyrosine residues under mild conditions using readily available reagents. To illustrate translatability, a clinically approved hernia repair mesh (based on decellularized porcine dermis) is labeled, preserving morphological and mechanical properties. In a mouse model of mesh implantation, implants retain marked X-ray contrast up to 3 months, together with an unchanged degradation rate and inflammatory response. The technique's compatibility is demonstrated with a range of therapeutically relevant protein formats including bovine, porcine, and jellyfish collagen, as well as silk sutures, enabling a wide range of surgical and regenerative medicine uses. This solution tackles the challenge of visualizing implanted protein-based biomaterials, which conventional imaging methods fail to differentiate from endogenous tissue. This will address previously unanswered questions regarding the accuracy of implantation, degradation rate, migration, and structural integrity, thereby accelerating optimization and safe translation of therapeutic biomaterials.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Camundongos , Animais , Bovinos , Suínos , Alicerces Teciduais/química , Engenharia Tecidual/métodos , Raios X , Halogenação , Materiais Biocompatíveis/química
7.
Eur Radiol ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37938387

RESUMO

OBJECTIVES: To identify imaging, clinical, and laboratory variables potentially prognostic for surgical management of small bowel obstruction. METHODS: Two researchers systematically reviewed indexed literature 2001-2021 inclusive for imaging, clinical, and laboratory variables potentially predictive of surgical management of small bowl obstruction and/or ischaemia at surgery, where performed. Risk of bias was assessed. Contingency tables for variables reported in at least 5 studies were extracted and meta-analysed to identify strong evidence of association with clinical outcomes, across studies. RESULTS: Thirty-one studies were ultimately included, reporting 4638 patients (44 to 313 per study). 11 (35%) studies raised no risk of bias concerns. CT was the modality reported most (29 studies, 94%). Meta-analysis of 21 predictors identified 5 strongly associated with surgical intervention, 3 derived from CT (peritoneal free fluid, odds ratio [OR] 3.24, 95%CI 2.45 to 4.29; high grade obstruction, OR 3.58, 95%CI 2.46 to 5.20; mesenteric inflammation, OR 2.61, 95%CI 1.94 to 3.50; abdominal distension, OR 2.43, 95%CI 1.34 to 4.42; peritonism, OR 3.97, 95%CI 2.67 to 5.90) and one with conservative management (previous abdominopelvic surgery, OR 0.58, 95%CI 0.40 to 0.85). Meta-analysis of 10 predictors identified 3 strongly associated with ischaemia at surgery, 2 derived from CT (peritoneal free fluid, OR 3.49, 95%CI 2.28 to 5.35; bowel thickening, OR 3.26 95%CI 1.91 to 5.55; white cell count, OR 4.76, 95%CI 2.71 to 8.36). CONCLUSIONS: Systematic review of patients with small bowel obstruction identified four imaging, three clinical, and one laboratory predictors associated strongly with surgical intervention and/or ischaemia at surgery. CLINICAL RELEVANCE STATEMENT: Via systematic review and meta-analysis, we identified imaging, clinical, and laboratory predictors strongly associated with surgical management of small bowel obstruction and/or ischaemia. Multivariable model development to guide management should incorporate these since they display strong evidence of potential utility. KEY POINTS: • While multivariable models incorporating clinical, laboratory, and imaging factors could predict surgical management of small bowel obstruction, none are used widely. • Via systematic review and meta-analysis we identified imaging, clinical, and laboratory variables strongly associated with surgical management and/or ischaemia at surgery. • Development of multivariable models to guide management should incorporate these predictors, notably CT scanning, since they display strong evidence of potential utility.

8.
Eur Radiol ; 33(3): 2096-2104, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36282308

RESUMO

OBJECTIVES: To quantify reader agreement for the British Society of Thoracic Imaging (BSTI) diagnostic and severity classification for COVID-19 on chest radiographs (CXR), in particular agreement for an indeterminate CXR that could instigate CT imaging, from single and paired images. METHODS: Twenty readers (four groups of five individuals)-consultant chest (CCR), general consultant (GCR), and specialist registrar (RSR) radiologists, and infectious diseases clinicians (IDR)-assigned BSTI categories and severity in addition to modified Covid-Radiographic Assessment of Lung Edema Score (Covid-RALES), to 305 CXRs (129 paired; 2 time points) from 176 guideline-defined COVID-19 patients. Percentage agreement with a consensus of two chest radiologists was calculated for (1) categorisation to those needing CT (indeterminate) versus those that did not (classic/probable, non-COVID-19); (2) severity; and (3) severity change on paired CXRs using the two scoring systems. RESULTS: Agreement with consensus for the indeterminate category was low across all groups (28-37%). Agreement for other BSTI categories was highest for classic/probable for the other three reader groups (66-76%) compared to GCR (49%). Agreement for normal was similar across all radiologists (54-61%) but lower for IDR (31%). Agreement for a severe CXR was lower for GCR (65%), compared to the other three reader groups (84-95%). For all groups, agreement for changes across paired CXRs was modest. CONCLUSION: Agreement for the indeterminate BSTI COVID-19 CXR category is low, and generally moderate for the other BSTI categories and for severity change, suggesting that the test, rather than readers, is limited in utility for both deciding disposition and serial monitoring. KEY POINTS: • Across different reader groups, agreement for COVID-19 diagnostic categorisation on CXR varies widely. • Agreement varies to a degree that may render CXR alone ineffective for triage, especially for indeterminate cases. • Agreement for serial CXR change is moderate, limiting utility in guiding management.


Assuntos
COVID-19 , Humanos , Radiografia Torácica/métodos , Reprodutibilidade dos Testes , Radiografia , Radiologistas , Estudos Retrospectivos
9.
Br J Radiol ; 96(1142): 20211369, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35766953

RESUMO

Mesenteric panniculitis is encountered frequently during abdominopelvic CT scanning, often as an incidental finding. The observation is problematic because an association with malignancy has been raised in the literature. This review will describe the CT appearances and examine the available evidence regarding the significance of this finding.Ultimately, the literature remains unclear regarding how these patients should be managed, if at all.


Assuntos
Neoplasias , Paniculite Peritoneal , Humanos , Paniculite Peritoneal/diagnóstico por imagem , Paniculite Peritoneal/complicações , Neoplasias/complicações , Tomografia Computadorizada por Raios X
10.
Lancet Digit Health ; 4(12): e899-e905, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36427951

RESUMO

Rigorous evaluation of artificial intelligence (AI) systems for image classification is essential before deployment into health-care settings, such as screening programmes, so that adoption is effective and safe. A key step in the evaluation process is the external validation of diagnostic performance using a test set of images. We conducted a rapid literature review on methods to develop test sets, published from 2012 to 2020, in English. Using thematic analysis, we mapped themes and coded the principles using the Population, Intervention, and Comparator or Reference standard, Outcome, and Study design framework. A group of screening and AI experts assessed the evidence-based principles for completeness and provided further considerations. From the final 15 principles recommended here, five affect population, one intervention, two comparator, one reference standard, and one both reference standard and comparator. Finally, four are appliable to outcome and one to study design. Principles from the literature were useful to address biases from AI; however, they did not account for screening specific biases, which we now incorporate. The principles set out here should be used to support the development and use of test sets for studies that assess the accuracy of AI within screening programmes, to ensure they are fit for purpose and minimise bias.


Assuntos
Inteligência Artificial , Diagnóstico por Imagem , Programas de Rastreamento
11.
BMJ Open ; 12(10): e067265, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36192092

RESUMO

INTRODUCTION: Crohn's disease (CD) is characterised by discontinuous, relapsing enteric inflammation. Instituting advanced therapies at an early stage to suppress inflammation aims to prevent future complications such as stricturing or penetrating disease, and subsequent surgical resection. Therapeutics are effective but associated with certain side-effects and relatively expensive. There is therefore an urgent need for robust methods to predict which newly diagnosed patients will develop disabling disease, to identify patients who are most likely to benefit from early, advanced therapies. We aim to determine if magnetic resonance enterography (MRE) features at diagnosis improve prediction of disabling CD within 5 years of diagnosis. METHODS AND ANALYSIS: We describe the protocol for a multicentre, non-randomised, single-arm, prospective study of adult patients with newly diagnosed CD. We will use patients already recruited to the METRIC study and extend their clinical follow-up, as well as a separate group of newly diagnosed patients who were not part of the METRIC trial (MRE within 3 months of diagnosis), to ensure an adequate sample size. Follow-up will extend for at least 4 years. The primary outcome is to evaluate the comparative predictive ability of prognostic models incorporating MRE severity scores (Magnetic resonance Enterography Global Score (MEGS), simplified MAgnetic Resonance Index of Activity (sMaRIA) and Lémann Index) versus models using standard characteristics alone to predict disabling CD (modified Beaugerie definition) within 5 years of new diagnosis. ETHICS AND DISSEMINATION: This study protocol achieved National Health Service Research Ethics Committee (NHS REC), London-Hampstead Research Ethics Committee approval (IRAS 217422). Our findings will be disseminated via conference presentations and peer-reviewed publications. TRIAL REGISTRATION NUMBER: ISRCTN76899103.


Assuntos
Doença de Crohn , Adulto , Doença de Crohn/tratamento farmacológico , Humanos , Inflamação , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Medicina Estatal
12.
Lancet Digit Health ; 4(7): e558-e565, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35750402

RESUMO

Artificial intelligence (AI) could have the potential to accurately classify mammograms according to the presence or absence of radiological signs of breast cancer, replacing or supplementing human readers (radiologists). The UK National Screening Committee's assessments of the use of AI systems to examine screening mammograms continues to focus on maximising benefits and minimising harms to women screened, when deciding whether to recommend the implementation of AI into the Breast Screening Programme in the UK. Maintaining or improving programme specificity is important to minimise anxiety from false positive results. When considering cancer detection, AI test sensitivity alone is not sufficiently informative, and additional information on the spectrum of disease detected and interval cancers is crucial to better understand the benefits and harms of screening. Although large retrospective studies might provide useful evidence by directly comparing test accuracy and spectrum of disease detected between different AI systems and by population subgroup, most retrospective studies are biased due to differential verification (ie, the use of different reference standards to verify the target condition among study participants). Enriched, multiple-reader, multiple-case, test set laboratory studies are also biased due to the laboratory effect (ie, radiologists' performance in retrospective, laboratory, observer studies is substantially different to their performance in a clinical environment). Therefore, assessment of the effect of incorporating any AI system into the breast screening pathway in prospective studies is required as it will provide key evidence for the effect of the interaction of medical staff with AI, and the impact on women's outcomes.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Inteligência Artificial , Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Estudos Retrospectivos , Reino Unido
13.
BMJ Open ; 12(5): e053204, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35501093

RESUMO

INTRODUCTION: Chronic liver disease is a growing cause of morbidity and mortality in the UK. Acute presentation with advanced disease is common and prioritisation of resources to those at highest risk at earlier disease stages is essential to improving patient outcomes. Existing prognostic tools are of limited accuracy and to date no imaging-based tools are used in clinical practice, despite multiple anatomical imaging features that worsen with disease severity.In this paper, we outline our scoping review protocol that aims to provide an overview of existing prognostic factors and models that link anatomical imaging features with clinical endpoints in chronic liver disease. This will provide a summary of the number, type and methods used by existing imaging feature-based prognostic studies and indicate if there are sufficient studies to justify future systematic reviews. METHODS AND ANALYSIS: The protocol was developed in accordance with existing scoping review guidelines. Searches of MEDLINE and Embase will be conducted using titles, abstracts and Medical Subject Headings restricted to publications after 1980 to ensure imaging method relevance on OvidSP. Initial screening will be undertaken by two independent reviewers. Full-text data extraction will be undertaken by three pretrained reviewers who have participated in a group data extraction session to ensure reviewer consensus and reduce inter-rater variability. Where needed, data extraction queries will be resolved by reviewer team discussion. Reporting of results will be based on grouping of related factors and their cumulative frequencies. Prognostic anatomical imaging features and clinical endpoints will be reported using descriptive statistics to summarise the number of studies, study characteristics and the statistical methods used. ETHICS AND DISSEMINATION: Ethical approval is not required as this study is based on previously published work. Findings will be disseminated by peer-reviewed publication and/or conference presentations.


Assuntos
Hepatopatias , Projetos de Pesquisa , Humanos , Hepatopatias/diagnóstico por imagem , Programas de Rastreamento , Literatura de Revisão como Assunto
15.
J Crohns Colitis ; 16(10): 1531-1539, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35481898

RESUMO

BACKGROUND AND AIMS: The simplified magnetic resonance enterography [MRE] index of activity [sMARIA], London, and 'extended' London, scoring systems are widely used in Crohn's disease [CD] to assess disease activity, although validation studies have usually been single-centre, retrospective, and/or used few readers. Here, we evaluated these MRE indices within a prospective, multicentre, multireader, diagnostic accuracy trial. METHODS: A subset of participants [newly diagnosed or suspected of relapse] recruited to the METRIC trial with available terminal ileal [TI] biopsies was included. Using pre-specified thresholds, the sensitivity and specificity of sMARIA, London, and 'extended' London scores for active and severe [sMARIA] TI CD were calculated using different thresholds for the histological activity index [HAI]. RESULTS: We studied 111 patients [median age 29 years, interquartile range 21-41, 75 newly diagnosed, 36 suspected relapse] from seven centres, of whom 22 had no active TI CD [HAI = 0], 39 mild [HAI = 1], 13 moderate [HAI = 2], and 37 severe CD activity [HAI = 3]. In total, 26 radiologists prospectively scored MRE datasets as per their usual clinical practice. Sensitivity and specificity for active disease [HAI >0] were 83% [95% confidence interval 74% to 90%] and 41% [23% to 61%] for sMARIA, 76% [67% to 84%] and 64% [43% to 80%] for the London score, and 81% [72% to 88%] and 41% [23% to 61%] for the 'extended' London score, respectively. The sMARIA had 84% [69-92%] sensitivity and 53% [41-64%] specificity for severe CD. CONCLUSIONS: When tested at their proposed cut-offs in a real-world setting, sMARIA, London, and 'extended' London indices achieve high sensitivity for active TI disease against a histological reference standard, but specificity is low.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Estudos Retrospectivos , Estudos Prospectivos , Imageamento por Ressonância Magnética , Recidiva , Padrões de Referência , Espectroscopia de Ressonância Magnética
16.
Eur Radiol ; 32(9): 6348-6354, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35348860

RESUMO

OBJECTIVES: Systematic review of CT measurements to predict the success or failure of subsequent ventral hernia repair has found limited data available in the indexed literature. To rectify this, we investigated multiple preoperative CT metrics to identify if any were associated with postoperative reherniation. METHODS: Following ethical permission, we identified patients who had undergone ventral hernia repair and had preoperative CT scanning available. Two radiologists made multiple measurements of the hernia and abdominal musculature from these scans, including loss of domain. Patients were divided subsequently into two groups, defined by hernia recurrence at 1-year subsequent to surgery. Hypothesis testing investigated any differences between CT measurements from each group. RESULTS: One hundred eighty-eight patients (95 male) were identified, 34 (18%) whose hernia had recurred by 1-year. Only three of 34 CT measurements were significantly different when patients whose hernia had recurred were compared to those who had not; these significant findings were assumed contingent on multiple testing. In particular, preoperative hernia volume (recurrence 155.3 cc [IQR 355.65] vs. no recurrence 78.2 [IQR 303.52], p = 0.26) nor loss of domain, whether calculated using the Tanaka (recurrence 0.02 [0.04] vs. no recurrence 0.009 [0.04], p = 0.33) or Sabbagh (recurrence 0.019 [0.05] vs. no recurrence 0.009 [0.04], p = 0.25) methods, differed between significantly between groups. CONCLUSIONS: Preoperative CT measurements of ventral hernia morphology, including loss of domain, appear unrelated to postoperative recurrence. It is likely that the importance of such measurements to predict recurrence is outweighed by other patient factors and surgical reconstruction technique. KEY POINTS: • Preoperative CT scanning is often performed for ventral hernia but systematic review revealed little data regarding whether CT variables predict postoperative reherniation. • We found that the large majority of CT measurements, including loss of domain, did not differ significantly between patients whose hernia did and did not recur. • It is likely that the importance of CT measurements to predict recurrence is outweighed by other patient factors and surgical reconstruction technique.


Assuntos
Parede Abdominal , Hérnia Ventral , Parede Abdominal/cirurgia , Estudos de Casos e Controles , Feminino , Hérnia Ventral/diagnóstico por imagem , Hérnia Ventral/cirurgia , Herniorrafia/métodos , Humanos , Masculino , Estudos Retrospectivos , Telas Cirúrgicas , Tomografia Computadorizada por Raios X
17.
Eur Radiol ; 32(8): 5075-5085, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35243523

RESUMO

OBJECTIVES: To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE. METHODS: This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohn's. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting ≤ 1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into "very tolerable," "moderately tolerable," and "not tolerable." RESULTS: Per patient distension quality was similar between agents ("excellent" or "good" in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as "very tolerable" in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%). CONCLUSION: Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. KEY POINTS: • Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol. • Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles. • Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol.


Assuntos
Doença de Crohn , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Adulto , Meios de Contraste/farmacologia , Doença de Crohn/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Manitol/farmacologia , Avaliação de Resultados da Assistência ao Paciente , Polietilenoglicóis , Estudos Prospectivos , Estudos Retrospectivos
18.
Br J Radiol ; 95(1134): 20210995, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35195444

RESUMO

OBJECTIVES: To evaluate interobserver variability for diagnosis of disease presence and extent of small bowel and colonic Crohn's disease using MR enterography (MRE). METHODS: Data from the first 73 consecutive patients (mean age 32, 33F, 28 new diagnosis, 45 suspected relapse) recruited to a multicentre, prospective diagnostic accuracy trial evaluating MRE for small bowel Crohn's disease were each read independently by three (from a pool of 20) radiologists. Radiologists documented presence and segmental location of small bowel Crohn's disease and recorded morphological mural/extramural parameters for involved segments. Per patient percentage agreement for disease presence and extent were calculated against an outcome-based construct reference standard (averaged between pairs of readers). Prevalence-adjusted bias-adjusted κ (PABAK) was calculated. RESULTS: Agreement for small bowel disease presence for new diagnosis/relapsed patients was 68%(κ = 0.36)/ 78% (κ = 0.56) and 43%(κ = 0.14)/ 53% for disease extent (κ = 0.07), respectively. For disease presence, all three radiologists agreed correctly with the reference standard in 41/59 (69%) of patients with small bowel involvement, and in 8/14 (57%) cases of without small bowel disease. Agreement was highest for multisegment disease, greater than 5 cm in length, with mural thickness>6 mm, and increased mural T2 signal. Agreement for colonic disease presence was 61% (κ = 0.21 fair agreement) for new diagnosis/ 60% (κ = 0.20, slight agreement) for relapsed patients. CONCLUSION: There is a reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed Crohn's disease, and patients with suspected relapse, respectively. Agreement is lower for disease extent. ADVANCES IN KNOWLEDGE: There is reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed (68%) Crohn's disease, and patients with suspected relapse (78%). Agreement is lower for disease extent (43% new diagnosis and 53% suspected relapse).


Assuntos
Doença de Crohn , Adulto , Ensaios Clínicos como Assunto , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Estudos Multicêntricos como Assunto , Variações Dependentes do Observador , Estudos Prospectivos , Recidiva
19.
Radiology ; 303(2): 361-370, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35166585

RESUMO

Background Most radiologists reporting CT colonography (CTC) do not undergo compulsory performance accreditation, potentially lowering diagnostic sensitivity. Purpose To determine whether 1-day individualized training in CTC reporting improves diagnostic sensitivity of experienced radiologists for 6-mm or larger lesions, the durability of any improvement, and any associated factors. Materials and Methods This prospective, multicenter cluster-randomized controlled trial was performed in National Health Service hospitals in England and Wales between April 2017 and January 2020. CTC services were cluster randomized into intervention (1-day training plus feedback) or control (no training or feedback) arms. Radiologists in the intervention arm attended a 1-day workshop focusing on CTC reporting pitfalls with individualized feedback. Radiologists in the control group received no training. Sensitivity for 6-mm or larger lesions was tested at baseline and 1, 6, and 12 months thereafter via interpretation of 10 CTC scans at each time point. The primary outcome was the mean difference in per-lesion sensitivity between arms at 1 month, analyzed using multilevel regression after adjustment for baseline sensitivity. Secondary outcomes included per-lesion sensitivity at 6- and 12-month follow-up, sensitivity for flat neoplasia, and effect of prior CTC experience. Results A total of 69 hospitals were randomly assigned to the intervention (31 clusters, 80 radiologists) or control (38 clusters, 59 radiologists) arm. Radiologists were experienced (median, 500-999 CTC scans interpreted) and reported CTC scans routinely (median, 151-200 scans per year). One-month sensitivity improved after intervention (66.4% [659 of 992]) compared with sensitivity in the control group (42.4% [278 of 655]; difference = 20.8%; 95% CI: 14.6, 27.0; P < .001). Improvements were maintained at 6 (66.4% [572 of 861] vs 50.5% [283 of 560]; difference = 13.0%; 95% CI: 7.4, 18.5; P < .001) and 12 (63.7% [310 of 487] vs 44.4% [187 of 421]; difference = 16.7%; 95% CI: 10.3, 23.1; P < .001) months. This beneficial effect applied to flat lesions (difference = 22.7%; 95% CI: 15.5, 29.9; P < .001) and was independent of career experience (≥1500 CTC scans: odds ratio = 1.09; 95% CI: 0.88, 1.36; P = .22). Conclusion For radiologists evaluating CT colonography studies, a 1-day training intervention yielded sustained improvement in detection of clinically relevant colorectal neoplasia, independent of previous career experience. Clinical trial registration no. NCT02892721 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Pickhardt in this issue. An earlier incorrect version appeared online and in print. This article was corrected on February 28, 2022.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer , Humanos , Estudos Prospectivos , Medicina Estatal
20.
Eur Radiol ; 31(11): 8597-8605, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34357449

RESUMO

OBJECTIVE: Radiological findings in solitary rectal ulcer syndrome (SRUS) are well described for evacuation proctography (EP) but sparse for magnetic resonance defecography (MRD). In order to rectify this, we describe the spectrum of MRD findings in patients with histologically proven SRUS. MATERIALS AND METHODS: MRD from twenty-eight patients (18 female; 10 males) with histologically confirmed SRUS were identified. MRD employed a 1.5-T magnet and a standardized technique with the rectal lumen filled with gel and imaged sagittally in the supine position, before, during, and after attempted rectal evacuation. A single radiologist observer with 5 years' experience in pelvic floor imaging made the anatomical and functional measurements. RESULTS: Sixteen patients (10 female) demonstrated internal rectal intussusception and 3 patients (11%) demonstrated complete external rectal prolapse. Anterior rectoceles were noted in 12 female patients (43%). Associated anterior and middle compartment weakness (evidenced by excessive descent) was observed in 18 patients (64%). Cystocele was found in 14 patients (50%) and uterine prolapse was noted in 7 patients (25%). Enterocoeles were detected in 5 patients (18%) and peritoneocoele in 5 patients (18%). None had sigmoidocoele. Sixteen patients (57%) demonstrated delayed voiding and 13 patients (46%) incomplete voiding, suggesting defecatory dyssynergia. CONCLUSION: MRD can identify and grade both rectal intussusception and dyssynergia in SRUS, and also depict associated anterior and/or middle compartment descent. Distinction between structural and functional findings has important therapeutic implications. KEY POINTS: MRD can identify and grade both rectal intussusception and dyssynergia in patients with SRUS. MRD is an acceptable substitute to evacuation proctography in assessing anorectal dysfunctions when attempting to avoid ionizing radiation. SRUS influences the pelvic floor globally. MRD depicts associated anterior and/or middle compartment prolapse.


Assuntos
Doenças Retais , Prolapso Retal , Defecografia , Feminino , Humanos , Masculino , Doenças Retais/diagnóstico por imagem , Prolapso Retal/complicações , Prolapso Retal/diagnóstico por imagem , Retocele , Úlcera/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...