Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Otol Neurotol ; 36(1): 172-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25076227

RESUMO

HYPOTHESIS: Power reflectance (PR) measurements in ears with superior canal dehiscence (SCD) have a characteristic pattern, the detection of which can assist in diagnosis. BACKGROUND: The aim of this study was to determine whether PR coupled with a novel detection algorithm can perform well as a fast, noninvasive, and easy screening test for SCD. The screening test aimed to determine whether patients with various vestibular and/or auditory symptom(s) should be further considered for more expensive and invasive tests that better define the diagnosis of SCD (and other third-window lesions). METHODS: Power reflectance was measured in patients diagnosed with SCD by high-resolution computed tomography. The study included 40 ears from 32 patients with varying symptoms (e.g., with and without conductive hearing loss, vestibular symptoms, and abnormal auditory sensations). RESULTS: Power reflectance results were compared to previously published norms and showed that SCD is commonly associated with a PR notch near 1 kHz. An analysis algorithm was designed to detect such notches and to quantify their incidence in affected and normal ears. Various notch detection thresholds yielded sensitivities of 80% to 93%, specificities of 69% to 72%, negative predictive values of 84% to 93%, and a positive predictive value of 67%. CONCLUSION: This study shows evidence that PR measurements together with the proposed notch-detecting algorithm can be used to quickly and effectively screen patients for third-window lesions such as SCD in the early stages of a diagnostic workup.


Assuntos
Algoritmos , Técnicas de Diagnóstico Otológico , Doenças do Labirinto/diagnóstico , Canais Semicirculares/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Tomografia Computadorizada por Raios X
2.
Ear Hear ; 33(1): 35-43, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21857516

RESUMO

OBJECTIVE: The goal of the present study was to investigate the clinical utility of measurements of ear-canal reflectance (ECR) in a population of patients with conductive hearing loss in the presence of an intact, healthy tympanic membrane and an aerated middle ear. We also sought to compare the diagnostic accuracy of umbo velocity (VU) measurements and measurements of ECR in the same group of patients. DESIGN: This prospective study comprised 31 adult patients with conductive hearing loss, of which 14 had surgically confirmed stapes fixation due to otosclerosis, 6 had surgically confirmed ossicular discontinuity, and 11 had computed tomography and vestibular evoked myogenic potential confirmed superior semicircular canal dehiscence (SCD). Measurements on all 31 ears included pure-tone audiometry for 0.25 to 8 kHz, ECR for 0.2 to 6 kHz using the Mimosa Acoustics HearID system, and VU for 0.3 to 6 kHz using the HLV-1000 laser Doppler vibrometer (Polytec Inc, Waldbronn, Germany). We analyzed power reflectance |ECR| as well as the absorbance level = 10 × log10(1 - |ECR|). All measurements were made before any surgical intervention. The VU and ECR data were plotted against normative data obtained in a companion study of 58 strictly defined normal ears (). RESULTS: Small increases in |ECR| at low-to-mid frequencies (400-1000 Hz) were observed in cases with stapes fixation, while narrowband decreases were seen for both SCD and ossicular discontinuity. The SCD and ossicular discontinuity differed in that the SCD had smaller decreases at mid-frequency (∼1000 Hz), whereas ossicular discontinuity had larger decreases at lower frequencies (500-800 Hz). SCD tended to have less air-bone gap at high frequencies (1-4 kHz) compared with stapes fixation and ossicular discontinuity. The |ECR| measurements, in conjunction with audiometry, could successfully separate 28 of the 31 cases into the three pathologies. By comparison, VU measurements, in conjunction with audiometry, could successfully separate various pathologies in 29 of 31 cases. CONCLUSIONS: The combination of |ECR| with audiometry showed clinical utility in the differential diagnosis of conductive hearing loss in the presence of an intact tympanic membrane and an aerated middle ear and seems to be of similar sensitivity and specificity to measurements of VU plus audiometry. Additional research is needed to expand upon these promising preliminary results.


Assuntos
Testes de Impedância Acústica/métodos , Testes de Impedância Acústica/normas , Meato Acústico Externo/fisiologia , Perda Auditiva Condutiva/diagnóstico , Membrana Timpânica/fisiologia , Adulto , Idoso , Audiometria de Tons Puros , Feminino , Perda Auditiva Condutiva/patologia , Perda Auditiva Condutiva/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Cuidados Pré-Operatórios , Estudos Prospectivos , Reprodutibilidade dos Testes , Canais Semicirculares/patologia , Sensibilidade e Especificidade , Mobilização do Estribo , Adulto Jovem
3.
Ear Hear ; 33(1): 19-34, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21857517

RESUMO

OBJECTIVE: This study compares measurements of ear-canal reflectance (ECR) to other objective measurements of middle ear function including audiometry, umbo velocity (VU), and tympanometry in a population of strictly defined normal-hearing ears. DESIGN: Data were prospectively gathered from 58 ears of 29 normal-hearing subjects, 16 females and 13 males, aged 22 to 64 yr. Subjects met all of the following criteria to be considered as having normal hearing: (1) no history of significant middle ear disease; (2) no history of otologic surgery; (3) normal tympanic membrane on otoscopy; (4) pure-tone audiometric thresholds of 20 dB HL or better for 0.25 to 8 kHz; (5) air-bone gaps no greater than 15 dB at 0.25 kHz and 10 dB for 0.5 to 4 kHz; (6) normal, type-A peaked tympanograms; and (7) all subjects had two "normal" ears (as defined by these criteria). Measurements included pure-tone audiometry for 0.25 to 8 kHz, standard 226 Hz tympanometry, ECR for 0.2 to 6 kHz at 60 dB SPL using the Mimosa Acoustics HearID system, and umbo velocity (VU) for 0.3 to 6 kHz at 70 to 90 dB SPL using the HLV-1000 laser Doppler vibrometer (Polytec Inc). RESULTS: Mean power reflectance (|ECR|) was near 1.0 at 0.2 to 0.3 kHz, decreased to a broad minimum of 0.3 to 0.4 between 1 and 4 kHz, and then sharply increased to almost 0.8 by 6 kHz. The mean pressure reflectance phase angle (∠ECR) plotted on a linear frequency scale showed a group delay of approximately 0.1 msec for 0.2 to 6 kHz. Small significant differences were observed in |ECR| at the lowest frequencies between right and left ears and between males and females at 4 kHz. |ECR| decreased with age but reached significance only at 1 kHz. Our ECR measurements were generally similar to previous published reports. Highly significant negative correlations were found between |ECR| and VU for frequencies below 1 kHz. Significant correlations were also found between the tympanometrically determined peak total compliance and |ECR| and VU at frequencies below 1 kHz. The results suggest that middle ear compliance contributes significantly to the measured power reflectance and umbo velocity at frequencies below 1 kHz but not at higher frequencies. CONCLUSIONS: This study has established a database of objective measurements of middle ear function (ECR, umbo velocity, tympanometry) in a population of strictly defined normal-hearing ears. These data will promote our understanding of normal middle ear function and will serve as a control for comparison to similar measurements made in pathological ears.


Assuntos
Testes de Impedância Acústica/normas , Meato Acústico Externo/fisiologia , Orelha Média/fisiologia , Audição/fisiologia , Testes de Impedância Acústica/métodos , Adulto , Audiometria de Tons Puros/métodos , Audiometria de Tons Puros/normas , Calibragem/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Caracteres Sexuais , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...