Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38567801

RESUMO

OBJECTIVE: This in-vitro study assessed the influence of two intraoral scanning (IOS) protocols on the accuracy (trueness and precision) of digital scans performed in edentulous arches. METHODS: Twenty-two abutment-level master casts of edentulous arches with at least four implants were scanned repeatedly five times, each with two different scanning protocols. Protocol A (IOS-A) consisted of scanning the edentulous arch before inserting the implant scan bodies, followed by their insertion and its subsequent digital acquisition. Protocol B (IOS-B) consisted of scanning the edentulous arch with the scan bodies inserted from the outset. A reference scan from each edentulous cast was obtained using a laboratory scanner. Trueness and precision were calculated using the spatial fit analysis, cross-arch distance, and virtual Sheffield test. Statistical analysis was performed using generalized estimating equations (GEEs). Statistical significance was set at α = .05. RESULTS: In the spatial fit test, the precision of average 3D distances was 45 µm (±23 µm) with protocol IOS-A and 25 µm (±10 µm) for IOS-B (p < .001), and the trueness of average 3D distances was 44 µm (±24 µm) with protocol IOS-A and 24 µm (±7 µm) for IOS-B (p < .001). Cross-arch distance precision was 59 µm (±53 µm) for IOS-A and 41 µm (±43 µm) for IOS-B (p = .0035), and trueness was 64 µm (±47 µm) for IOS-A and 50 µm (±40 µm) for IOS-B (p = .0021). Virtual Sheffield precision was 286 µm (±198 µm) for IOS-A and 146 µm (±92 µm) for IOS-B (p < .001), and trueness was 228 µm (±171 µm) for IOS-A and 139 µm (±92 µm) for IOS-B (p < .001). CONCLUSIONS: The IOS-B protocol demonstrated significantly superior accuracy. Placement of scan bodies before scanning the edentulous arch is recommended to improve the accuracy of complete-arch intraoral scanning.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38613432

RESUMO

BACKGROUND: For over three decades, digital technologies have been used in Implant Dentistry, beginning with the introduction of planning software for Static Computer-Assisted Implant Surgery (S-CAIS). During this time, this field has witnessed the emergence of diverse methodologies and a proliferation of technological advancements. Today, S-CAIS is a widely adopted procedure for the placement of dental implants in both partially and fully edentulous patients, with Dynamic Computer-Assisted Surgery (D-CAIS) and Robotic-Assisted Implant Surgery (RAIS) rapidly gaining attention among dental professionals. The continuous advancements in this arena are not merely indicative of technological progress; they represent a steadfast dedication to refining precision, enhancing efficiency, and fostering innovation with the goal of optimizing patient outcomes in dental implantology. AIMS: The purpose of the following review is to meticulously examine the spectrum of digital technologies available and to describe their protocols, advantages, and shortcomings as well as to evaluate their accuracy in implant surgery in patients with complete edentulism. MATERIALS AND METHODS: A scoping review was performed following the Joanna Briggs Institute (JBI) protocols, leveraging the population, concept, and context (PCC) framework to construct the research question and determine the inclusion and exclusion criteria. RESULTS: Two hundred and sixty-seven records were identified for screening. After applying all the screening criteria, 41 articles were included for review and qualitative data analysis. DISCUSSION: S-CAIS, D-CAIS, and RAIS were identified as the main technologies for computer assisted implant surgery. Their applications, characteristics, protocols and levels of accuracy were compared and described. CONCLUSION: Taking into consideration the limitations of this study, S-CAIS appears to be the most applied and validated technology in implant surgery for fully edentulous patients followed by D-CAIS and RAIS being these last two promising initiatives in the field. Despite having similar levels of accuracy, the overall comparison showed a slightly higher values in RAIS followed by D-CAIS and S-CAIS.

3.
Int J Periodontics Restorative Dent ; 0(0): 1-27, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38198437

RESUMO

INTRODUCTION: The interforaminal region is considered more favorable for implant placement than the posterior mandible in edentulous patients, mainly because of the interference of the inferior alveolar nerve with implant placement in the severely resorbed posterior mandible. However, complications in the interforaminal region may occur due to the presence of the mandibular incisive nerve. OBJECTIVE: This scoping review aims to describe the mandibular incisive nerve anatomy related to the potential interference in implant therapy. MATERIAL AND METHODS: A comprehensive literature search was conducted in the following databases: MEDLINE (via PubMed), Web of Science, and Scopus. This scoping review was structured according to the Joanna Briggs Institute method. RESULTS: Thirteen studies were included in the review. All the studies were observational cohort anatomical studies, carried out mainly by CBCT and on cadavers. A total of 1471 patients/cadavers were studied. The mandibular incisive nerve was presented in 87-100% of the cases, with an average length of 9.97 mm and an average diameter of 1.97 mm. The mandibular incisive nerve may be damaged during drilling and implant placement, especially using implant lengths larger than 12 mm. CONCLUSIONS: Damage to the mandibular incisive nerve due to implant placement could be present, however, it is necessary to conduct more studies focusing on assessing mandibular incisive nerve damage to understand the clinical relevance of this nerve and its associated morbidities such as neurosensorial alterations. Due to the different anatomical characteristics of this nerve, CBCT analysis is recommended for implant therapy in the anterior mandible to prevent the described complications.

4.
J Esthet Restor Dent ; 36(1): 207-219, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018396

RESUMO

OBJECTIVE: To provide technical and clinical recommendations for implementing a digital workflow in Static Computer-Aided Implant Surgery in the anterior maxilla. CLINICAL CONSIDERATIONS: An optimal 3D implant position is crucial for achieving satisfying results in implant rehabilitation in the esthetic area. Due to its complexity, implant placement in the esthetic zone should be executed with precision and predictability. Static Computer-Aided Implant Surgery requires thorough planning and detailed attention to every step of the digital workflow protocol. CONCLUSIONS: Implant positioning in the esthetic zone using Static Computer-Aided Implant Surgery is a technique-sensitive procedure that requires precise execution of each step. This approach ensures accurate prosthetically driven 3D implant placement and prevents potential errors that could lead to inaccurate positioning. CLINICAL SIGNIFICANCE: The proper implementation of Static Computer-Aided Implant Surgery may increase the level of agreement between the planned and definitive implant 3D positions in the esthetic zone, thus enhancing the esthetic outcomes of implant rehabilitation.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Estética Dentária , Implantação Dentária Endóssea/métodos , Cirurgia Assistida por Computador/métodos , Maxila/cirurgia , Computadores , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico
5.
Int J Prosthodont ; 0(0)2023 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-37824117

RESUMO

Traditionally, metal-ceramics, metal-reinforced acrylics, and more recently full-contour or layered zirconia have been the materials of choice for definitive fixed implant-supported rehabilitations. Polymethyl Methacrylate (PMMA) is commonly used in implant dentistry for the fabrication of implant-supported interim prostheses and as milled or 3D printed prototypes. This article describes a novel protocol to prosthetically restore a completely edentulous patient following a digital workflow, with fixed, screw-retained, implant-supported prostheses fabricated from CAD/CAM milled polymethyl methacrylate (PMMA), with no metal substructure. After two years follow up in terms of esthetics, phonetics, function and biological tissue response, the outcome remains functional and free of mechanical, biomechanical or biological complications. The aim of this article is to illustrate the feasibility of using milled PMMA as viable definitive prosthetic material for the fixed implant rehabilitation of edentulous patients.

6.
Clin Oral Implants Res ; 34 Suppl 26: 304-348, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750515

RESUMO

OBJECTIVES: The aim of this study was to review available evidence for Type 1A (immediate implant placement and immediate loading) of single tooth replacement in the maxillary esthetic zone. MATERIALS AND METHODS: An electronic search was conducted utilizing the databases of MEDLINE, Embase, and Cochrane to identify publications reporting on the outcomes of Type 1A for single tooth replacement in the maxillary esthetic zone. The success and survival rates of the included articles were reported, which were further categorized according to the clinical criteria reported in Type 1A. Mean survival rates were univariately compared between risk groups and additionally between studies published before and since 2012 using bias-corrected and study size-weighed bootstrap tests. A study time-correcting meta-analysis was then performed to obtain an overall effect for the study pool. RESULTS: A total of 3118 publications were identified in the search, with a total of 68 articles included. A mean number of implants per study were 37.2 and mean follow-up was 2.8 years. All the included studies utilizing Type 1A report highly selective inclusion and exclusion criteria. Univariate risk group comparison determined that studies before 2012 report a significantly lower mean survival rate (difference of -1.9 percentage points [PP], 95% CI: [-0.3, -4.0], p = .02), facial gap dimension had an impact on survival rates (+3.1 PP [0.2, 5.3] for width >2 mm, p = .04), as well as presence of endodontic infection (+2.6 PP [0.9, 5.1], p = .004). CONCLUSIONS: Type 1A has a high survival rate in studies reporting strict patient and site selection criteria. Further research is required to assess esthetic and functional success with Type 1A treatments.


Assuntos
Implantes Dentários , Humanos , Seleção de Pacientes , Estética Dentária , Bases de Dados Factuais
7.
Clin Oral Implants Res ; 34 Suppl 26: 349-356, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750529

RESUMO

OBJECTIVES: Working Group 5 was convened to discuss and find consensus on the topics of implant placement and loading protocols associated with single missing teeth in the anterior maxilla (aesthetic zone). Consensus statements, clinical recommendations, patient perspectives and future research suggestions were developed and presented to the plenary for discussion and approval. MATERIALS AND METHODS: Two systematic reviews were developed and submitted prior to the conference. The group considered in detail the systematic reviews and developed statements, clinical recommendations, patient perspectives and future research suggestions based on the findings of the reviews and experience of group members. Definitive versions were developed after presentation to and discussion by the plenary. RESULTS: Five consensus statements were developed and approved from each systematic review. Twelve clinical recommendations were developed by the group based on both reviews and experience. Three patient perspectives were developed, and five suggestions made for future research. CONCLUSIONS: Based on the findings of the systematic reviews and experience of group members, the Type 1A protocol (immediate placement and immediate loading), when utilized in the anterior maxilla under favorable conditions, is considered predictable and is associated with high survival rates. The procedure is considered clinically viable and is associated with aesthetic outcomes, although surgical, technical, and biological complications can occur.


Assuntos
Implantes Dentários , Perda de Dente , Humanos , Consenso , Guias de Prática Clínica como Assunto , Revisões Sistemáticas como Assunto
8.
Clin Oral Implants Res ; 34 Suppl 26: 266-303, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750531

RESUMO

OBJECTIVES: The aim of this study was to assess the following PIO question: In adult patients treated with an indication for single tooth extraction in the maxillary esthetic zone (15-25), what is the influence of an immediate implant placement and immediate loading protocol on the clinical performance (primary aim) and esthetic outcomes (secondary aim) focusing on investigations published after 2010. MATERIAL AND METHODS: An electronic search in Medline (PubMed), the Cochrane Central Register of Controlled Trials, and EMBASE databases up to April 2022 was performed to identify clinical studies investigating the outcome of single implants subjected to immediate placement with immediate restoration/loading (Type 1A). RESULTS: Sixty-three studies (10 randomized controlled trials, 28 prospective and 25 retrospective cohort studies) were included with a follow-up ranging from 12 to 96 months. One thousand nine hundred sixty-one implants reported survival rates of 99.2 (98.6-99.5) % at 1 year, 97.5 (95.9-98.4) % after 3 years, and 95.8 (93.3-97.4) % after 5 years; 1064 immediately loaded restorations presented survival rates of 98.9 (97.8-99.5) % after 1 year, 96.8 (93.6-98.4) % after 2 years, and 94.8 (89.6-97.4) % after 5 years. Comparing baseline to 12-month data using the Hedges' g effect size (95% CI), papilla height presented an overall effect size of -0.71 (-1.25, -0.1) mm, midfacial recession change of -0.15 (-0.66, 0.36) mm, and a 0.82 (0.37, 1.28) gain in PES. CONCLUSIONS: Immediate implant placement and immediate loading can be considered a predictable and safe treatment option for single maxillary anterior restorations with adequate survival rates and favorable esthetics outcomes for up to 5 years.


Assuntos
Implantes Dentários , Adulto , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Estética Dentária , Bases de Dados Factuais
9.
Aging Clin Exp Res ; 35(7): 1505-1512, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37142942

RESUMO

BACKGROUND: Several studies reported cognitive reserve (CR) as an important factor in promoting healthy aging within a non-clinical aging population. AIMS: The main goal of the present study is to investigate the link between higher levels of CR and more effective emotion regulation. In more detail, we examine the association between a number of CR proxies and the habitual use of two emotion regulation strategies, cognitive reappraisal and emotional suppression. METHODS: Three hundred and ten older adults aged between 60 and 75 (mean = 64.45, SD = 4.37; 69.4% female) joined this cross-sectional study by filling out self-report measures of CR and emotion regulation.² RESULTS: Reappraisal and suppression use were correlated. Practicing different leisure activities constantly over many years, being more original and having a higher education promoted more frequent use of cognitive reappraisal. These CR proxies were also significantly related to suppression use, even though the percentage of variance explained was lower. DISCUSSION AND CONCLUSIONS: Exploring the role played by the cognitive reserve on different emotion regulation techniques can be useful in understanding which variables predict the use of antecedent-focused (reappraisal) or response-focused (suppression) emotion regulation strategies in aging individuals.


Assuntos
Reserva Cognitiva , Regulação Emocional , Humanos , Feminino , Idoso , Masculino , Reserva Cognitiva/fisiologia , Estudos Transversais , Emoções/fisiologia , Envelhecimento/psicologia
10.
Front Cell Neurosci ; 17: 895017, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37006470

RESUMO

Introduction: Increasing evidence indicates that neurodegenerative diseases, including Alzheimer's disease (AD), are a product of gene-by-environment interplay. The immune system is a major contributor mediating these interactions. Signaling between peripheral immune cells and those within the microvasculature and meninges of the central nervous system (CNS), at the blood-brain barrier, and in the gut likely plays an important role in AD. The cytokine tumor necrosis factor (TNF) is elevated in AD patients, regulates brain and gut barrier permeability, and is produced by central and peripheral immune cells. Our group previously reported that soluble TNF (sTNF) modulates cytokine and chemokine cascades that regulate peripheral immune cell traffic to the brain in young 5xFAD female mice, and in separate studies that a diet high in fat and sugar (HFHS) dysregulates signaling pathways that trigger sTNF-dependent immune and metabolic responses that can result in metabolic syndrome, which is a risk factor for AD. We hypothesized that sTNF is a key mediator of peripheral immune cell contributions to gene-by-environment interactions to AD-like pathology, metabolic dysfunction, and diet-induced gut dysbiosis. Methods: Female 5xFAD mice were subjected to HFHS diet for 2 months and then given XPro1595 to inhibit sTNF for the last month or saline vehicle. We quantified immune cell profiles by multi-color flow cytometry on cells isolated from brain and blood; metabolic, immune, and inflammatory mRNA and protein marker biochemical and immunhistological analyses, gut microbiome, and electrophysiology in brain slices were also performed. Results: Here, we show that selective inhibition of sTNF signaling via the biologic XPro1595 modulates the effects of an HFHS diet in 5xFAD mice on peripheral and central immune profiles including CNS-associated CD8+ T cells, the composition of gut microbiota, and long-term potentiation deficits. Discussion: Obesogenic diet induces immune and neuronal dysfunction in 5xFAD mice and sTNF inhibition mitigates its effects. A clinical trial in subjects at risk for AD due to genetic predisposition and underlying inflammation associated with peripheral inflammatory co-morbidities will be needed to investigate the extent to which these findings translate to the clinic.

11.
J Esthet Restor Dent ; 35(7): 1058-1067, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37078683

RESUMO

OBJECTIVE: To describe a strategy using digital technologies for improving the diagnosis, treatment planning, and surgical execution of patients with excessive gingival display (EGD) due to altered passive eruption (APE). CLINICAL CONSIDERATIONS: An important component for successful patient's management is to fulfill their esthetic expectations whilst delivering predictable and long-term therapeutic outcomes. To achieve this goal in patients with excessive gingival display due to altered passive eruption, it is essential to perform an accurate diagnosis and to communicate to the patient the expected customized results using digital technologies. Computer-aided designed and manufactured multifunctional anatomical prototypes (MAPs) may contribute to these purposes. Additionally, they can guide the surgical crown lengthening procedure or serve as a reference during the surgical guide fabrication providing information of the required anatomical landmarks. CONCLUSIONS: This novel strategy protocol for diagnosis, communication, and treatment management of patients with excessive gingival display follows functional and biological principles within the frame of a digital workflow, which improves the diagnostic capabilities, enhances communication, and guides the surgical treatment as shown in the 12 months follow-up of the reported case. CLINICAL SIGNIFICANCE: Developing a virtual patient by combining multiple digital data sets including cone-beam computed tomography (CBCT), intra-oral scans and digital photography, supports the clinician and the patient to achieve a comprehensive diagnosis and to better communicate the expected results to the patient. Furthermore, this digital treatment exercise based on anatomical and biological principles will facilitate the surgical precision and the achievement of successful outcomes, thus fulfilling the patient needs and expectations.


Assuntos
Estética Dentária , Dente , Humanos , Gengiva , Coroa do Dente , Gengivectomia
12.
J Prosthet Dent ; 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36959002

RESUMO

Removal of cement-retained complete arch implant-supported zirconia restorations can be challenging. A predictable and minimally invasive technique combining cone beam computed tomography (CBCT) and intraoral scans with a virtual implant planning software program is described to identify the location of the screw access channels during the retrieval, thus minimizing damage to the existing restoration and allowing reuse.

13.
Clin Oral Implants Res ; 34(5): 463-474, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36806171

RESUMO

OBJECTIVE: This study aims to report the implant survival rate of dental implants of partially dentate patients in the anterior mandible and the potential risk indicators for implant failure. MATERIALS AND METHODS: Patients with implant-supported restorations of single or multiple teeth in the anterior mandible restored with fixed partial implant-supported restorations were evaluated. Patient demographic data, implant placement timing, and loading protocol, biological and/or technical complications at the time of the last clinical and radiographic follow-up visit were registered. Survival rate, success rate, and potential risk indicators for implant failure were calculated. RESULTS: A total of 108 patients and 186 implants with a mean follow-up period of 5.48 years (0.1-11.34 years) were included. The 11.3-year cumulative survival rate was 90.9%. Immediate implant placement (OR = 2.75) (p = .08) and immediate implant loading (OR = 8.8) (p = .02*) indicated a higher risk of failure than late implant placement or loading. When combining both categories (type 1A), an OR = 10.59 (p = .04*) for implant failure was found compared to category 4C. Implants placed following static-computer-assisted implant surgery (S-CAIS) showed less risk of failure compared to freehand implant placement (OR = 0.18; 95% CI: 0.02-1.37) (p = .09). CONCLUSIONS: The survival rate of implants placed in the anterior mandible was considerably low (90.9%). S-CAIS, late placement, and conventional loading are protective factor against implant failure in the anterior mandible.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Implantação Dentária Endóssea/métodos , Estudos Retrospectivos , Falha de Restauração Dentária , Prótese Dentária Fixada por Implante , Planejamento de Prótese Dentária , Carga Imediata em Implante Dentário/métodos , Mandíbula/cirurgia , Seguimentos
14.
Clin Implant Dent Relat Res ; 25(4): 710-722, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36691784

RESUMO

Over the past decade, emerging evidence indicates a strong relationship between prosthetic design and peri-implant tissue health. The objective of this narrative review was to evaluate the evidence for the corresponding implant prosthodontic design factors on the risk to peri-implant tissue health. One of the most important factors to achieve an acceptable implant restorative design is the ideal implant position. Malpositioned implants often result in a restorative emergence profile at the implant-abutment junction that can restrict the access for patients to perform adequate oral hygiene. Inadequate cleansability and poor oral hygiene has been reported as a precipitating factors to induce the peri-implant mucositis and peri-implantitis and are influenced by restorative contours. The implant-abutment connection, restorative material selection and restoration design are also reported in the literature as having the potential to influence peri-implant sort tissue health.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Peri-Implantite/etiologia , Implantes Dentários/efeitos adversos , Fatores Desencadeantes , Prostodontia , Materiais Dentários
15.
J Prosthet Dent ; 129(3): 395-399, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34229898

RESUMO

A method is described for the verification and correction of a digital scan of a complete arch implant-supported prosthesis for a completely edentulous patient. The technique provides an efficient way to integrate a highly accurate and precise scan of an implant index cast with a digital intraoral implant scan by using a computer-aided design and computer-aided manufacturing (CAD-CAM) software program. This method allows dental professionals to validate and, if necessary, correct the implant positions in the scan without the need for a conventional impression.


Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador
16.
Int J Prosthodont ; 36(1): 74­80, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36165883

RESUMO

This case report describes a new digital workflow for computer-assisted implant surgery in an edentulous patient using transitional implants to support a fixed surgical template and interim prosthesis. The accuracy of the final implant position using the described protocol was evaluated and compared to the outcomes obtained using other types of surgical templates. This novel digital approach appears to enhance the accuracy of implant positioning for edentulous patients and seems to be comparable to a tooth-supported surgical template.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea/métodos , Arcada Edêntula/cirurgia , Arcada Edêntula/reabilitação , Prótese Dentária Fixada por Implante , Cirurgia Assistida por Computador/métodos , Boca Edêntula/cirurgia , Computadores , Desenho Assistido por Computador
17.
Int Rev Neurobiol ; 167: 251-290, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36427958

RESUMO

Spinal cord injuries are an enormous burden on injured individuals and their caregivers. The pathophysiological effects of injury are not limited to the spine and limb function, but affect numerous body systems. Growing observations in human studies and experimental models suggest that the gut microbiome is altered following spinal cord injury. Given the importance of signals derived from the gut microbiome for host physiology, it is possible that injury-triggered dysbiosis subsequently affects aspects of recovery. Here, we review emerging literature on the role of the microbiome following spinal cord injury. Specifically, we highlight findings from both human and experimental studies that correlate taxonomic changes to aspects of injury recovery. Examination of both observational and emerging interventional studies supports the notion that future therapeutic avenues for spinal cord injury pathologies may lie at the interface of the host and indigenous microbes.


Assuntos
Microbioma Gastrointestinal , Traumatismos da Medula Espinal , Humanos , Traumatismos da Medula Espinal/patologia
18.
Clin Oral Implants Res ; 33(12): 1273-1281, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36239539

RESUMO

OBJECTIVES: Registration of intra-oral surface scans to cone beam computer tomography (CBCT) is critical in the digital workflow for static computer-aided implant surgery (sCAIS). This study aimed to assess the impact of CBCT field of view (FoV) on the precision of digital intra-oral scan registration. MATERIALS AND METHODS: Cone beam computer tomography data and intra-oral scans from 20 patients were included. Small FoV CBCT's were created by digitally segmenting a large FoV into three sextants. Virtual implant planning was performed. Digital intra-oral scans were repeatedly registered onto their corresponding large and small FoV CBCT datasets. The distances and angulations between the matching implant positions of each repeated registration were used to determine the precision of the registration process. Wilcoxon Signed Rank Paired Tests were used to compare the differences between large FoV and small FoV. The threshold for statistical significance was set at p = .05. RESULTS: Differences in 3D implant position based on the registration precision between small FoV and large FoV present at both the implant entry point (0.37 ± 0.25 mm vs 0.35 ± 0.23 mm, p = .482) and implant tip (0.49 ± 0.34 mm vs 0.37 ± 0.24 mm, p < .001). Differences in overall angular precision were observed between small FOV and large FoV (1.43 ± 1.36° vs 0.51 ± 0.38°, p < .001). CONCLUSION: CBCT with a small FoV is accompanied by greater precision errors in intra-oral scan registration. However, when sufficient well-distributed teeth are visible in small FoV CBCT, the precision of digital intra-oral scan registration appears to be within clinically acceptable limits for sCAIS.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária , Boca , Cirurgia Assistida por Computador , Humanos , Implantação Dentária/métodos , Boca/diagnóstico por imagem
19.
Int J Oral Maxillofac Implants ; 37(3): 525-532, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35727244

RESUMO

PURPOSE: This study aimed to assess the influence of implant diameter and taper on the proximity of virtually planned maxillary central incisor implants to the nasopalatine canal and adjacent anatomical structures. MATERIALS AND METHODS: Virtual implant planning was performed in the maxillary central incisor position. The distance between the implant and the incisive canal (IC) and the thickness of the surrounding buccal and palatal bone walls were measured. Implants were categorized as having an exposed implant surface, thin bone, or moderate/thick bone. Measurements were repeated for regular-/narrow-diameter and parallel/tapered implants. RESULTS: A total of 60 patients were included, and 240 implants (60 of each type: 3.3-bone level [BL], 3.3-bone level tapered [BLT], 4.1-BL, and 4.1-BLT) were planned. The percentages of implants with between 0 and 0.5 mm of remaining bone in the coronal aspect of the IC were 31.6% for 4.1-BL/BLT and 6.6% for 3.3-BL/BLT (P < .001). The percentage of implants with IC exposure was 13.3% for 4.1-BL/BLT and 6.6% for 3.3-BL/BLT (P < .001). The frequency of sites that required bone augmentation at the coronal facial aspect (< 1 mm) was 52.6% and 33.9% for 4.1-BL/BLT and 3.3-BL/BLT, respectively. At the apical portion, the percentages of sites requiring bone augmentation at the facial aspect were 59.9%, 49.9%, 31.6%, and 23.3% for 4.1-BL, 3.3-BL, 4.1-BLT, and 3.3-BLT, respectively (P < .001). CONCLUSION: The proximity of the nasopalatine canal is often < 0.5 mm from regular-diameter virtually planned implants at the most coronal aspect in the maxillary central incisor position. In these situations, the selection of narrowdiameter implants significantly lowers the incidence of implant exposure and the need for additional management of the nasopalatine canal and also results in greater residual buccal and lingual bone thicknesses surrounding the implant. As expected, tapered implants reduced the risk of implant exposure through the buccal cortex at the apical aspect.


Assuntos
Implantes Dentários , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Incisivo/diagnóstico por imagem , Maxila/diagnóstico por imagem , Maxila/cirurgia
20.
J Prosthet Dent ; 2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35431031

RESUMO

A method for the digital articulation of complete arch digital implant scans using the implant abutment prosthetic interfaces is described. This technique provides an effective and efficient method for articulating digital scans without the need for matching soft tissue references or fiduciary markers. This allows for a streamlined workflow with fewer intraoral scans and can provide a precise replication of the intaglio surface and emergence profile of an existing restoration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...