Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Nat Commun ; 12(1): 5907, 2021 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-34625559

RESUMO

Parkinson's disease and related synucleinopathies are characterized by the abnormal accumulation of alpha-synuclein aggregates, loss of dopaminergic neurons, and gliosis of the substantia nigra. Although clinical evidence and in vitro studies indicate disruption of the Blood-Brain Barrier in Parkinson's disease, the mechanisms mediating the endothelial dysfunction is not well understood. Here we leveraged the Organs-on-Chips technology to develop a human Brain-Chip representative of the substantia nigra area of the brain containing dopaminergic neurons, astrocytes, microglia, pericytes, and microvascular brain endothelial cells, cultured under fluid flow. Our αSyn fibril-induced model was capable of reproducing several key aspects of Parkinson's disease, including accumulation of phosphorylated αSyn (pSer129-αSyn), mitochondrial impairment, neuroinflammation, and compromised barrier function. This model may enable research into the dynamics of cell-cell interactions in human synucleinopathies and serve as a testing platform for target identification and validation of novel therapeutics.


Assuntos
Barreira Hematoencefálica/metabolismo , Encéfalo/metabolismo , Doença de Parkinson/metabolismo , Sinucleinopatias/metabolismo , alfa-Sinucleína/metabolismo , Astrócitos/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Neurônios Dopaminérgicos/metabolismo , Células Endoteliais/metabolismo , Gliose/patologia , Humanos , Microglia/metabolismo , Mitocôndrias/metabolismo , Pericitos/metabolismo , Fosforilação , Substância Negra/metabolismo , Transcriptoma
2.
Elife ; 102021 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-34378534

RESUMO

Traditional drug safety assessment often fails to predict complications in humans, especially when the drug targets the immune system. Here, we show the unprecedented capability of two human Organs-on-Chips to evaluate the safety profile of T-cell bispecific antibodies (TCBs) targeting tumor antigens. Although promising for cancer immunotherapy, TCBs are associated with an on-target, off-tumor risk due to low levels of expression of tumor antigens in healthy tissues. We leveraged in vivo target expression and toxicity data of TCBs targeting folate receptor 1 (FOLR1) or carcinoembryonic antigen (CEA) to design and validate human immunocompetent Organs-on-Chips safety platforms. We discovered that the Lung-Chip and Intestine-Chip could reproduce and predict target-dependent TCB safety liabilities, based on sensitivity to key determinants thereof, such as target expression and antibody affinity. These novel tools broaden the research options available for mechanistic understandings of engineered therapeutic antibodies and assessing safety in tissues susceptible to adverse events.


Assuntos
Anticorpos Biespecíficos/efeitos adversos , Dispositivos Lab-On-A-Chip/estatística & dados numéricos , Linfócitos T/imunologia , Animais , Feminino , Células HEK293 , Células HeLa , Humanos , Imunoterapia/métodos , Camundongos
3.
Cell Mol Gastroenterol Hepatol ; 12(5): 1719-1741, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34284165

RESUMO

BACKGROUND & AIMS: The limited availability of organoid systems that mimic the molecular signatures and architecture of human intestinal epithelium has been an impediment to allowing them to be harnessed for the development of therapeutics as well as physiological insights. We developed a microphysiological Organ-on-Chip (Emulate, Inc, Boston, MA) platform designed to mimic properties of human intestinal epithelium leading to insights into barrier integrity. METHODS: We combined the human biopsy-derived leucine-rich repeat-containing G-protein-coupled receptor 5-positive organoids and Organ-on-Chip technologies to establish a micro-engineered human Colon Intestine-Chip (Emulate, Inc, Boston, MA). We characterized the proximity of the model to human tissue and organoids maintained in suspension by RNA sequencing analysis, and their differentiation to intestinal epithelial cells on the Colon Intestine-Chip under variable conditions. Furthermore, organoids from different donors were evaluated to understand variability in the system. Our system was applied to understanding the epithelial barrier and characterizing mechanisms driving the cytokine-induced barrier disruption. RESULTS: Our data highlight the importance of the endothelium and the in vivo tissue-relevant dynamic microenvironment in the Colon Intestine-Chip in the establishment of a tight monolayer of differentiated, polarized, organoid-derived intestinal epithelial cells. We confirmed the effect of interferon-γ on the colonic barrier and identified reorganization of apical junctional complexes, and induction of apoptosis in the intestinal epithelial cells as mediating mechanisms. We show that in the human Colon Intestine-Chip exposure to interleukin 22 induces disruption of the barrier, unlike its described protective role in experimental colitis in mice. CONCLUSIONS: We developed a human Colon Intestine-Chip platform and showed its value in the characterization of the mechanism of action of interleukin 22 in the human epithelial barrier. This system can be used to elucidate, in a time- and challenge-dependent manner, the mechanism driving the development of leaky gut in human beings and to identify associated biomarkers.


Assuntos
Microambiente Celular , Colo/fisiologia , Mucosa Intestinal/metabolismo , Biomarcadores , Técnicas de Cultura de Células , Biologia Computacional , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Humanos , Interleucinas/metabolismo , Mucosa Intestinal/microbiologia , Dispositivos Lab-On-A-Chip , Organoides , Permeabilidade , Transcriptoma , Interleucina 22
4.
Biomaterials ; 275: 120957, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34130145

RESUMO

Successful translation of in vivo experimental data to human patients is an unmet need and a bottleneck in the development of effective therapeutics. Organ-on-Chip technology aims to address this need by leveraging recent significant advancements in microfabrication and biomaterials, which enable modeling of organs and their functionality. These microengineered chips offer researchers the possibility to recreate critical elements of native tissue architecture such as in vivo relevant tissue-tissue interface, air-liquid interface, and mechanical forces, including mechanical stretch and fluidic shear stress, which are crucial to recapitulate tissue level functions. Here, we present the development of a new, comprehensive 3D cell-culture system, where we combined our proprietary Organ-Chip technology with the advantages offered by three-dimensional organotypic culture. Leveraging microfabrication techniques, we engineered a flexible chip that consists of a chamber containing an organotypic epithelium, surrounded by two vacuum channels that can be actuated to stretch the hydrogel throughout its thickness. Furthermore, the ceiling of this chamber is a removable lid with a built-in microchannel that can be perfused with liquid or air and removed as needed for direct access to the tissue. The bottom part of this chamber is made from a porous flexible membrane which allows diffusive mass transport to and from the microfluidic channel positioned below the membrane. This additional microfluidic channel can be coated with endothelial cells to emulate a blood vessel and recapitulate endothelial interactions. Our results show that the Open-Top Chip design successfully addresses common challenges associated with the Organs-on-Chip technology, including the capability to incorporate a tissue-specific extracellular matrix gel seeded with primary stromal cells, to reproduce the architectural complexity of tissues by micropatterning the gel, and to extract the gel for H&E staining. We also provide proof-of-concept data on the feasibility of using the system with primary human skin and alveolar epithelial cells.


Assuntos
Células Endoteliais , Dispositivos Lab-On-A-Chip , Endotélio , Humanos , Microfluídica , Microtecnologia
5.
Nature ; 586(7830): 509-515, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32967005

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the aetiological agent of coronavirus disease 2019 (COVID-19), an emerging respiratory infection caused by the introduction of a novel coronavirus into humans late in 2019 (first detected in Hubei province, China). As of 18 September 2020, SARS-CoV-2 has spread to 215 countries, has infected more than 30 million people and has caused more than 950,000 deaths. As humans do not have pre-existing immunity to SARS-CoV-2, there is an urgent need to develop therapeutic agents and vaccines to mitigate the current pandemic and to prevent the re-emergence of COVID-19. In February 2020, the World Health Organization (WHO) assembled an international panel to develop animal models for COVID-19 to accelerate the testing of vaccines and therapeutic agents. Here we summarize the findings to date and provides relevant information for preclinical testing of vaccine candidates and therapeutic agents for COVID-19.


Assuntos
Infecções por Coronavirus/tratamento farmacológico , Infecções por Coronavirus/prevenção & controle , Modelos Animais de Doenças , Pandemias/prevenção & controle , Pneumonia Viral/tratamento farmacológico , Pneumonia Viral/prevenção & controle , Animais , Betacoronavirus/efeitos dos fármacos , Betacoronavirus/imunologia , COVID-19 , Vacinas contra COVID-19 , Infecções por Coronavirus/imunologia , Furões/virologia , Humanos , Mesocricetus/virologia , Camundongos , Pneumonia Viral/imunologia , Primatas/virologia , SARS-CoV-2 , Vacinas Virais/imunologia
6.
Am J Respir Cell Mol Biol ; 63(5): 591-600, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32706623

RESUMO

Viral-induced exacerbation of asthma remains a major cause of hospitalization and mortality. New human-relevant models of the airways are urgently needed to understand how respiratory infections may trigger asthma attacks and to advance treatment development. Here, we describe a new human-relevant model of rhinovirus-induced asthma exacerbation that recapitulates viral infection of asthmatic airway epithelium and neutrophil transepithelial migration, and enables evaluation of immunomodulatory therapy. Specifically, a microengineered model of fully differentiated human mucociliary airway epithelium was stimulated with IL-13 to induce a T-helper cell type 2 asthmatic phenotype and infected with live human rhinovirus 16 (HRV16) to reproduce key features of viral-induced asthma exacerbation. We observed that the infection with HRV16 replicated key hallmarks of the cytopathology and inflammatory responses observed in human airways. Generation of a T-helper cell type 2 microenvironment through exogenous IL-13 stimulation induced features of asthmatic airways, including goblet cell hyperplasia, reduction of cilia beating frequency, and endothelial activation, but did not alter rhinovirus infectivity or replication. High-resolution kinetic analysis of secreted inflammatory markers revealed that IL-13 treatment altered IL-6, IFN-λ1, and CXCL10 secretion in response to HRV16. Neutrophil transepithelial migration was greatest when viral infection was combined with IL-13 treatment, whereas treatment with MK-7123, a CXCR2 antagonist, reduced neutrophil diapedesis in all conditions. In conclusion, our microengineered Airway Lung-Chip provides a novel human-relevant platform for exploring the complex mechanisms underlying viral-induced asthma exacerbation. Our data suggest that IL-13 may impair the hosts' ability to mount an appropriate and coordinated immune response to rhinovirus infection. We also show that the Airway Lung-Chip can be used to assess the efficacy of modulators of the immune response.


Assuntos
Asma/virologia , Bioengenharia , Progressão da Doença , Dispositivos Lab-On-A-Chip , Pulmão/patologia , Pulmão/virologia , Microtecnologia , Modelos Biológicos , Movimento Celular , Células Cultivadas , Efeito Citopatogênico Viral , Humanos , Infiltração de Neutrófilos , Receptores de Interleucina-8B/antagonistas & inibidores , Receptores de Interleucina-8B/metabolismo , Rhinovirus
7.
ALTEX ; 37(3): 365-394, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32113184

RESUMO

The first microfluidic microphysiological systems (MPS) entered the academic scene more than 15 years ago and were considered an enabling technology to human (patho)biology in vitro and, therefore, provide alternative approaches to laboratory animals in pharmaceutical drug development and academic research. Nowadays, the field generates more than a thousand scientific publications per year. Despite the MPS hype in academia and by platform providers, which says this technology is about to reshape the entire in vitro culture landscape in basic and applied research, MPS approaches have neither been widely adopted by the pharmaceutical industry yet nor reached regulated drug authorization processes at all. Here, 46 leading experts from all stakeholders - academia, MPS supplier industry, pharmaceutical and consumer products industries, and leading regulatory agencies - worldwide have analyzed existing challenges and hurdles along the MPS-based assay life cycle in a second workshop of this kind in June 2019. They identified that the level of qualification of MPS-based assays for a given context of use and a communication gap between stakeholders are the major challenges for industrial adoption by end-users. Finally, a regulatory acceptance dilemma exists against that background. This t4 report elaborates on these findings in detail and summarizes solutions how to overcome the roadblocks. It provides recommendations and a roadmap towards regulatory accepted MPS-based models and assays for patients' benefit and further laboratory animal reduction in drug development. Finally, experts highlighted the potential of MPS-based human disease models to feedback into laboratory animal replacement in basic life science research.


Assuntos
Alternativas aos Testes com Animais , Bem-Estar do Animal , Desenvolvimento de Medicamentos , Avaliação Pré-Clínica de Medicamentos/métodos , Dispositivos Lab-On-A-Chip , Animais , Indústria Farmacêutica , Humanos , Modelos Biológicos
8.
Elife ; 92020 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-31933478

RESUMO

Induction of intestinal drug metabolizing enzymes can complicate the development of new drugs, owing to the potential to cause drug-drug interactions (DDIs) leading to changes in pharmacokinetics, safety and efficacy. The development of a human-relevant model of the adult intestine that accurately predicts CYP450 induction could help address this challenge as species differences preclude extrapolation from animals. Here, we combined organoids and Organs-on-Chips technology to create a human Duodenum Intestine-Chip that emulates intestinal tissue architecture and functions, that are relevant for the study of drug transport, metabolism, and DDI. Duodenum Intestine-Chip demonstrates the polarized cell architecture, intestinal barrier function, presence of specialized cell subpopulations, and in vivo relevant expression, localization, and function of major intestinal drug transporters. Notably, in comparison to Caco-2, it displays improved CYP3A4 expression and induction capability. This model could enable improved in vitro to in vivo extrapolation for better predictions of human pharmacokinetics and risk of DDIs.


Assuntos
Avaliação Pré-Clínica de Medicamentos/instrumentação , Interações Medicamentosas , Duodeno/metabolismo , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Animais , Células CACO-2 , Biologia Computacional , Citocromo P-450 CYP3A/metabolismo , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Humanos , Microvilosidades , Técnicas de Cultura de Órgãos , Organoides/metabolismo , Permeabilidade , Transcriptoma
9.
Clin Pharmacol Ther ; 107(1): 181-185, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31758803

RESUMO

There have been rapid advances since Organs-on-Chips were first developed. Organ-Chips are now available beyond academic laboratories with the initial emphasis to reduce animal experimentation and improve predictability of drug development through better prediction of safety and efficacy. There is now a huge opportunity to use chips to understand efficacy and disease variability. We propose that by 2030, Organs-on-Chips will play a key role in clinical pharmacology as part of the diagnostic and treatment workflow for some diseases by informing the right drug and dose regimen for each patient.


Assuntos
Desenvolvimento de Medicamentos/métodos , Dispositivos Lab-On-A-Chip , Farmacologia Clínica/métodos , Alternativas aos Testes com Animais/métodos , Animais , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/prevenção & controle , Humanos
10.
Sci Transl Med ; 11(517)2019 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-31694927

RESUMO

Nonclinical rodent and nonrodent toxicity models used to support clinical trials of candidate drugs may produce discordant results or fail to predict complications in humans, contributing to drug failures in the clinic. Here, we applied microengineered Organs-on-Chips technology to design a rat, dog, and human Liver-Chip containing species-specific primary hepatocytes interfaced with liver sinusoidal endothelial cells, with or without Kupffer cells and hepatic stellate cells, cultured under physiological fluid flow. The Liver-Chip detected diverse phenotypes of liver toxicity, including hepatocellular injury, steatosis, cholestasis, and fibrosis, and species-specific toxicities when treated with tool compounds. A multispecies Liver-Chip may provide a useful platform for prediction of liver toxicity and inform human relevance of liver toxicities detected in animal studies to better determine safety and human risk.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/patologia , Dispositivos Lab-On-A-Chip , Fígado/patologia , Animais , Biomarcadores/metabolismo , Doença Hepática Induzida por Substâncias e Drogas/patologia , Cães , Humanos , Células de Kupffer/metabolismo , Fígado/lesões , Hepatopatias/patologia , Fenótipo , Ratos , Reprodutibilidade dos Testes , Fatores de Risco , Especificidade da Espécie
11.
Arch Toxicol ; 93(4): 1021-1037, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30915487

RESUMO

Drug-induced liver injury remains a frequent reason for drug withdrawal. Accordingly, more predictive and translational models are required to assess human hepatotoxicity risk. This study presents a comprehensive evaluation of two promising models to assess mechanistic hepatotoxicity, microengineered Organ-Chips and 3D hepatic spheroids, which have enhanced liver phenotype, metabolic activity and stability in culture not attainable with conventional 2D models. Sensitivity of the models to two hepatotoxins, acetaminophen (APAP) and fialuridine (FIAU), was assessed across a range of cytotoxicity biomarkers (ATP, albumin, miR-122, α-GST) as well as their metabolic functionality by quantifying APAP, FIAU and CYP probe substrate metabolites. APAP and FIAU produced dose- and time-dependent increases in miR-122 and α-GST release as well as decreases in albumin secretion in both Liver-Chips and hepatic spheroids. Metabolic turnover of CYP probe substrates, APAP and FIAU, was maintained over the 10-day exposure period at concentrations where no cytotoxicity was detected and APAP turnover decreased at concentrations where cytotoxicity was detected. With APAP, the most sensitive biomarkers were albumin in the Liver-Chips (EC50 5.6 mM, day 1) and miR-122 and ATP in the liver spheroids (14-fold and EC50 2.9 mM, respectively, day 3). With FIAU, the most sensitive biomarkers were albumin in the Liver-Chip (EC50 126 µM) and miR-122 (15-fold) in the liver spheroids, both on day 7. In conclusion, both models exhibited integrated toxicity and metabolism, and broadly similar sensitivity to the hepatotoxicants at relevant clinical concentrations, demonstrating the utility of these models for improved hepatotoxicity risk assessment.


Assuntos
Doença Hepática Induzida por Substâncias e Drogas/metabolismo , Hepatócitos/efeitos dos fármacos , Fígado/efeitos dos fármacos , Modelos Biológicos , Esferoides Celulares/efeitos dos fármacos , Acetaminofen/toxicidade , Arabinofuranosiluracila/análogos & derivados , Arabinofuranosiluracila/toxicidade , Biomarcadores/metabolismo , Técnicas de Cultura de Células , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Glutationa Transferase/metabolismo , Hepatócitos/metabolismo , Humanos , Fígado/metabolismo , Esferoides Celulares/metabolismo
12.
Lab Chip ; 19(3): 410-421, 2019 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-30663729

RESUMO

Organ-Chips are micro-engineered systems that aim to recapitulate the organ microenvironment. Implementation of Organ-Chips within the pharmaceutical industry aims to improve the probability of success of drugs reaching late stage clinical trial by generating models for drug discovery that are of human origin and have disease relevance. We are adopting the use of Organ-Chips for enhancing pre-clinical efficacy and toxicity evaluation and prediction. Whilst capturing cellular phenotype via imaging in response to drug exposure is a useful readout in these models, application has been limited due to difficulties in imaging the chips at scale. Here we created an end-to-end, automated workflow to capture and analyse confocal images of multicellular Organ-Chips to assess detailed cellular phenotype across large batches of chips. By automating this process, we not only reduced acquisition time, but we also minimised process variability and user bias. This enabled us to establish, for the first time, a framework of statistical best practice for Organ-Chip imaging, creating the capability of using Organ-Chips and imaging for routine testing in drug discovery applications that rely on quantitative image data for decision making. We tested our approach using benzbromarone, whose mechanism of toxicity has been linked to mitochondrial damage with subsequent induction of apoptosis and necrosis, and staurosporine, a tool inducer of apoptosis. We also applied this workflow to assess the hepatotoxic effect of an active AstraZeneca drug candidate illustrating its applicability in drug safety assessment beyond testing tool compounds. Finally, we have demonstrated that this approach could be adapted to Organ-Chips of different shapes and sizes through application to a Kidney-Chip.


Assuntos
Dispositivos Lab-On-A-Chip , Imagem Óptica/instrumentação , Animais , Automação , Avaliação Pré-Clínica de Medicamentos , Humanos , Rim/diagnóstico por imagem , Rim/efeitos dos fármacos , Fígado/diagnóstico por imagem , Fígado/efeitos dos fármacos , Ratos
13.
ALTEX ; 36(2): 289-313, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30570669

RESUMO

Investigative Toxicology describes the de-risking and mechanistic elucidation of toxicities, supporting early safety decisions in the pharmaceutical industry. Recently, Investigative Toxicology has contributed to a shift in pharmaceutical toxicology, from a descriptive to an evidence-based, mechanistic discipline. This was triggered by high costs and low throughput of Good Laboratory Practice in vivo studies, and increasing demands for adhering to the 3R (Replacement, Reduction and Refinement) principles of animal welfare. Outside the boundaries of regulatory toxicology, Investigative Toxicology has the flexibility to embrace new technologies, enhancing translational steps from in silico, in vitro to in vivo mechanistic understanding to eventually predict human response. One major goal of Investigative Toxicology is improving preclinical decisions, which coincides with the concept of animal-free safety testing. Currently, compounds under preclinical development are being discarded due to the use of inappropriate animal models. Progress in Investigative Toxicology could lead to humanized in vitro test systems and the development of medicines less reliant on animal tests. To advance this field a group of 14 European-based leaders from the pharmaceutical industry founded the Investigative Toxicology Leaders Forum (ITLF), an open, non-exclusive and pre-competitive group that shares knowledge and experience. The ITLF collaborated with the Centre for Alternatives to Animal Testing Europe (CAAT-Europe) to organize an "Investigative Toxicology Think-Tank", which aimed to enhance the interaction with experts from academia and regulatory bodies in the field. Summarizing the topics and discussion of the workshop, this article highlights Investigative Toxicology's position by identifying key challenges and perspectives.


Assuntos
Descoberta de Drogas , Avaliação Pré-Clínica de Medicamentos/tendências , Toxicologia/tendências , Alternativas aos Testes com Animais , Animais , Simulação por Computador , Indústria Farmacêutica , Europa (Continente) , Humanos , Técnicas In Vitro , Medição de Risco
14.
Microfluid Nanofluidics ; 23(8)2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32296299

RESUMO

Human organoids and organ-on-chip systems to predict human responses to new therapies and for the understanding of disease mechanisms are being more commonly used in translational research. We have developed a bone-chip system to study osteogenic differentiation in vitro, coupled with optical imaging approach which provides the opportunity of monitoring cell survival, proliferation and differentiation in vitro without the need to terminate the culture. We used the mesenchymal stem cell (MSC) line over-expressing bone morphogenetic protein-2 (BMP-2), under Tet-Off system, and luciferase reporter gene under constitutive promoter. Cells were seeded on chips and supplemented with osteogenic medium. Flow of media was started 24 h later, while static cultures were performed using media reservoirs. Cells grown on the bone-chips under constant flow of media showed enhanced survival/proliferation, comparing to the cells grown in static conditions; luciferase reporter gene expression and activity, reflecting the cell survival and proliferation, was quantified using bioluminescence imaging and a significant advantage to the flow system was observed. In addition, the flow had positive effect on osteogenic differentiation, when compared with static cultures. Quantitative fluorescent imaging, performed using the osteogenic extra-cellular matrix-targeted probes, showed higher osteogenic differentiation of the cells under the flow conditions. Gene expression analysis of osteogenic markers confirmed the osteogenic differentiation of the MSC-BMP2 cells. Immunofluorescent staining performed against the Osteocalcin, Col1, and BSP markers illustrated robust osteogenic differentiation in the flow culture and lessened differentiation in the static culture. To sum, the bone-chip allows monitoring cell survival, proliferation, and osteogenic differentiation using optical imaging.

15.
Cell Mol Gastroenterol Hepatol ; 5(4): 669-677.e2, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29930984

RESUMO

BACKGROUND AND AIMS: Human intestinal organoids derived from induced pluripotent stem cells have tremendous potential to elucidate the intestinal epithelium's role in health and disease, but it is difficult to directly assay these complex structures. This study sought to make this technology more amenable for study by obtaining epithelial cells from induced pluripotent stem cell-derived human intestinal organoids and incorporating them into small microengineered Chips. We then investigated if these cells within the Chip were polarized, had the 4 major intestinal epithelial subtypes, and were biologically responsive to exogenous stimuli. METHODS: Epithelial cells were positively selected from human intestinal organoids and were incorporated into the Chip. The effect of continuous media flow was examined. Immunocytochemistry and in situ hybridization were used to demonstrate that the epithelial cells were polarized and possessed the major intestinal epithelial subtypes. To assess if the incorporated cells were biologically responsive, Western blot analysis and quantitative polymerase chain reaction were used to assess the effects of interferon (IFN)-γ, and fluorescein isothiocyanate-dextran 4 kDa permeation was used to assess the effects of IFN-γ and tumor necrosis factor-α on barrier function. RESULTS: The optimal cell seeding density and flow rate were established. The continuous administration of flow resulted in the formation of polarized intestinal folds that contained Paneth cells, goblet cells, enterocytes, and enteroendocrine cells along with transit-amplifying and LGR5+ stem cells. Administration of IFN-γ for 1 hour resulted in the phosphorylation of STAT1, whereas exposure for 3 days resulted in a significant upregulation of IFN-γ related genes. Administration of IFN-γ and tumor necrosis factor-α for 3 days resulted in an increase in intestinal permeability. CONCLUSIONS: We demonstrate that the Intestine-Chip is polarized, contains all the intestinal epithelial subtypes, and is biologically responsive to exogenous stimuli. This represents a more amenable platform to use organoid technology and will be highly applicable to personalized medicine and a wide range of gastrointestinal conditions.

16.
Stem Cell Reports ; 10(4): 1222-1236, 2018 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-29576540

RESUMO

Human stem cell-derived models of development and neurodegenerative diseases are challenged by cellular immaturity in vitro. Microengineered organ-on-chip (or Organ-Chip) systems are designed to emulate microvolume cytoarchitecture and enable co-culture of distinct cell types. Brain microvascular endothelial cells (BMECs) share common signaling pathways with neurons early in development, but their contribution to human neuronal maturation is largely unknown. To study this interaction and influence of microculture, we derived both spinal motor neurons and BMECs from human induced pluripotent stem cells and observed increased calcium transient function and Chip-specific gene expression in Organ-Chips compared with 96-well plates. Seeding BMECs in the Organ-Chip led to vascular-neural interaction and specific gene activation that further enhanced neuronal function and in vivo-like signatures. The results show that the vascular system has specific maturation effects on spinal cord neural tissue, and the use of Organ-Chips can move stem cell models closer to an in vivo condition.


Assuntos
Células Endoteliais/citologia , Células-Tronco Pluripotentes Induzidas/citologia , Dispositivos Lab-On-A-Chip , Neurônios Motores/citologia , Medula Espinal/citologia , Engenharia Tecidual/métodos , Encéfalo/irrigação sanguínea , Diferenciação Celular/genética , Sobrevivência Celular , Células Cultivadas , Matriz Extracelular/metabolismo , Desenvolvimento Fetal/genética , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Humanos , Microvasos/citologia , Somatostatina/metabolismo
17.
Clin Pharmacol Ther ; 104(6): 1240-1248, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29484632

RESUMO

Clinical development of Hu5c8, a monoclonal antibody against CD40L intended for treatment of autoimmune disorders, was terminated due to unexpected thrombotic complications. These life-threatening side effects were not discovered during preclinical testing due to the lack of predictive models. In the present study, we describe the development of a microengineered system lined by human endothelium perfused with human whole blood, a "Vessel-Chip." The Vessel-Chip allowed us to evaluate key parameters in thrombosis, such as endothelial activation, platelet adhesion, platelet aggregation, fibrin clot formation, and thrombin anti-thrombin complexes in the Chip-effluent in response to Hu5c8 in the presence of soluble CD40L. Importantly, the observed prothrombotic effects were not observed with Hu5c8-IgG2σ designed with an Fc domain that does not bind the FcγRIIa receptor, suggesting that this approach may have a low potential risk for thrombosis. Our results demonstrate the translational potential of Organs-on-Chips, as advanced microengineered systems to better predict human response.


Assuntos
Anticorpos Monoclonais Humanizados/toxicidade , Doenças Autoimunes/tratamento farmacológico , Coagulação Sanguínea/efeitos dos fármacos , Ligante de CD40/antagonistas & inibidores , Desenho de Fármacos , Desenvolvimento de Medicamentos/instrumentação , Fatores Imunológicos/toxicidade , Dispositivos Lab-On-A-Chip , Procedimentos Analíticos em Microchip , Trombose/induzido quimicamente , Anticorpos Monoclonais Humanizados/metabolismo , Doenças Autoimunes/imunologia , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Ligante de CD40/imunologia , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Fatores Imunológicos/metabolismo , Estudos Prospectivos , Receptores de IgG/metabolismo , Estudos Retrospectivos , Medição de Risco , Trombose/sangue
18.
Biomed Microdevices ; 18(4): 73, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27464497

RESUMO

The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccurate. It is challenging to include the endothelium in assays for clinical laboratories or point-of-care settings because living cell cultures are not sufficiently robust. Here, we describe a microfluidic device that is lined by a human endothelium that is chemically fixed, but still retains its ability to modulate hemostasis under continuous flow in vitro even after few days of storage. This device lined with a fixed endothelium supports formation of platelet-rich thrombi in the presence of physiological shear, similar to a living arterial vessel. We demonstrate the potential clinical value of this device by showing that thrombus formation and platelet function can be measured within minutes using a small volume (0.5 mL) of whole blood taken from subjects receiving antiplatelet medications. The inclusion of a fixed endothelial microvessel will lead to biomimetic analytical devices that can potentially be used for diagnostics and point-of-care applications.


Assuntos
Endotélio Vascular/efeitos dos fármacos , Dispositivos Lab-On-A-Chip , Trombose/diagnóstico , Plaquetas/efeitos dos fármacos , Células Endoteliais/efeitos dos fármacos , Fibrina/metabolismo , Células Endoteliais da Veia Umbilical Humana , Humanos , Inibidores da Agregação Plaquetária/farmacologia , Sistemas Automatizados de Assistência Junto ao Leito , Estresse Mecânico , Trombose/sangue , Trombose/tratamento farmacológico
19.
Nat Methods ; 13(2): 151-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26689262

RESUMO

Here we describe the development of a human lung 'small airway-on-a-chip' containing a differentiated, mucociliary bronchiolar epithelium and an underlying microvascular endothelium that experiences fluid flow, which allows for analysis of organ-level lung pathophysiology in vitro. Exposure of the epithelium to interleukin-13 (IL-13) reconstituted the goblet cell hyperplasia, cytokine hypersecretion and decreased ciliary function of asthmatics. Small airway chips lined with epithelial cells from individuals with chronic obstructive pulmonary disease recapitulated features of the disease such as selective cytokine hypersecretion, increased neutrophil recruitment and clinical exacerbation by exposure to viral and bacterial infections. With this robust in vitro method for modeling human lung inflammatory disorders, it is possible to detect synergistic effects of lung endothelium and epithelium on cytokine secretion, identify new biomarkers of disease exacerbation and measure responses to anti-inflammatory compounds that inhibit cytokine-induced recruitment of circulating neutrophils under flow.


Assuntos
Epitélio/efeitos dos fármacos , Inflamação/metabolismo , Interleucina-13/farmacologia , Dispositivos Lab-On-A-Chip , Pneumopatias/tratamento farmacológico , Pneumopatias/metabolismo , Humanos , Inflamação/patologia , Técnicas de Cultura de Tecidos
20.
J Med Chem ; 58(17): 7057-75, 2015 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-26291341

RESUMO

We report here a novel series of benzimidazole sulfonamides that act as antagonists of the S1P1 receptor, identified by exploiting an understanding of the pharmacophore of a high throughput screening (HTS)-derived series of compounds described previously. Lead compound 2 potently inhibits S1P-induced receptor internalization in a cell-based assay (EC50 = 0.05 µM), but has poor physical properties and metabolic stability. Evolution of this compound through structure-activity relationship development and property optimization led to in vivo probes such as 4. However, this compound was unexpectedly found to be a potent CYP3A inducer in human hepatocytes, and thus further chemistry efforts were directed at addressing this liability. By employing a pregnane X receptor (PXR) reporter gene assay to prioritize compounds for further testing in human hepatocytes, we identified lipophilicity as a key molecular property influencing the likelihood of P450 induction. Ultimately, we have identified compounds such as 46 and 47, which demonstrate the desired S1P1 antagonist activity while having greatly reduced risk of CYP3A induction in humans. These compounds have excellent oral bioavailability in preclinical species and exhibit pharmacodynamic effects of S1P1 antagonism in several in vivo models following oral dosing. Relatively modest antitumor activity was observed in multiple xenograft models, however, suggesting that selective S1P1 antagonists would have limited utility as anticancer therapeutics as single agents.


Assuntos
Benzimidazóis/química , Piridinas/química , Receptores de Lisoesfingolipídeo/antagonistas & inibidores , Sulfonamidas/química , Administração Oral , Antineoplásicos/síntese química , Antineoplásicos/química , Antineoplásicos/farmacologia , Benzimidazóis/síntese química , Benzimidazóis/farmacologia , Disponibilidade Biológica , Células Cultivadas , Citocromo P-450 CYP3A/biossíntese , Indutores do Citocromo P-450 CYP3A/síntese química , Indutores do Citocromo P-450 CYP3A/química , Indutores do Citocromo P-450 CYP3A/farmacologia , Genes Reporter , Hepatócitos/efeitos dos fármacos , Hepatócitos/metabolismo , Humanos , Modelos Moleculares , Estrutura Molecular , Receptor de Pregnano X , Piridinas/síntese química , Piridinas/farmacologia , Receptores de Esteroides/genética , Estereoisomerismo , Relação Estrutura-Atividade , Sulfonamidas/síntese química , Sulfonamidas/farmacologia , Ensaios Antitumorais Modelo de Xenoenxerto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...