Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Commun Med (Lond) ; 4(1): 68, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600290

RESUMO

BACKGROUND: In vivo imaging of the human retina using adaptive optics optical coherence tomography (AO-OCT) has transformed medical imaging by enabling visualization of 3D retinal structures at cellular-scale resolution, including the retinal pigment epithelial (RPE) cells, which are essential for maintaining visual function. However, because noise inherent to the imaging process (e.g., speckle) makes it difficult to visualize RPE cells from a single volume acquisition, a large number of 3D volumes are typically averaged to improve contrast, substantially increasing the acquisition duration and reducing the overall imaging throughput. METHODS: Here, we introduce parallel discriminator generative adversarial network (P-GAN), an artificial intelligence (AI) method designed to recover speckle-obscured cellular features from a single AO-OCT volume, circumventing the need for acquiring a large number of volumes for averaging. The combination of two parallel discriminators in P-GAN provides additional feedback to the generator to more faithfully recover both local and global cellular structures. Imaging data from 8 eyes of 7 participants were used in this study. RESULTS: We show that P-GAN not only improves RPE cell contrast by 3.5-fold, but also improves the end-to-end time required to visualize RPE cells by 99-fold, thereby enabling large-scale imaging of cells in the living human eye. RPE cell spacing measured across a large set of AI recovered images from 3 participants were in agreement with expected normative ranges. CONCLUSIONS: The results demonstrate the potential of AI assisted imaging in overcoming a key limitation of RPE imaging and making it more accessible in a routine clinical setting.


The retinal pigment epithelium (RPE) is a single layer of cells within the eye that is crucial for vision. These cells are unhealthy in many eye diseases, and this can result in vision problems, including blindness. Imaging RPE cells in living human eyes is time consuming and difficult with the current technology. Our method substantially speeds up the process of RPE imaging by incorporating artificial intelligence. This enables larger areas of the eye to be imaged more efficiently. Our method could potentially be used in the future during routine eye tests. This could lead to earlier detection and treatment of eye diseases, and the prevention of some causes of blindness.

2.
Invest Ophthalmol Vis Sci ; 64(14): 21, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37971733

RESUMO

Purpose: To apply adaptive optics-optical coherence tomography (AO-OCT) to quantify multiple sclerosis (MS)-induced changes in axonal bundles in the macular nerve fiber layer, ganglion cell somas, and macrophage-like cells at the vitreomacular interface. Methods: We used AO-OCT imaging in a pilot study of MS participants (n = 10), including those without and with a history of optic neuritis (ON, n = 4), and healthy volunteers (HV, n = 9) to reveal pathologic changes to inner retinal cells and structures affected by MS. Results: We found that nerve fiber layer axonal bundles had 38% lower volume in MS participants (1.5 × 10-3 mm3) compared to HVs (2.4 × 10-3 mm3; P < 0.001). Retinal ganglion cell (RGC) density was 51% lower in MS participants (12.3 cells/mm2 × 1000) compared to HVs (25.0 cells/mm2 × 1000; P < 0.001). Spatial differences across the macula were observed in RGC density. RGC diameter was 15% higher in MS participants (11.7 µm) compared to HVs (10.1 µm; P < 0.001). A nonsignificant trend of higher density of macrophage-like cells in MS eyes was also observed. For all AO-OCT measures, outcomes were worse for MS participants with a history of ON compared to MS participants without a history of ON. AO-OCT measures were associated with key visual and physical disabilities in the MS cohort. Conclusions: Our findings demonstrate the utility of AO-OCT for highly sensitive and specific detection of neurodegenerative changes in MS. Moreover, the results shed light on the mechanisms that underpin specific neuronal pathology that occurs when MS attacks the retina. The new findings support the further development of AO-based biomarkers for MS.


Assuntos
Esclerose Múltipla , Neurite Óptica , Humanos , Esclerose Múltipla/complicações , Projetos Piloto , Tomografia de Coerência Óptica/métodos , Retina/patologia , Células Ganglionares da Retina/patologia , Neurite Óptica/diagnóstico , Neurite Óptica/patologia
3.
Biomed Opt Express ; 14(4): 1772-1776, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37078031

RESUMO

The guest editors introduce a feature issue commemorating the 25th anniversary of adaptive optics in biomedical research.

4.
Neurophotonics ; 10(2): 025004, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37077218

RESUMO

Significance: Neuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions. Aim: We aim to demonstrate an imaging and stimulation platform that can elucidate the biological mechanisms and impacts of neurostimulation in the PNS and apply it to the sciatic nerve to extract imaging metrics indicating electrical overstimulation. Approach: A sciatic nerve injury model in a 15-rat cohort was observed using a newly developed imaging and stimulation platform that can detect electrical overstimulation effects with polarization-sensitive optical coherence tomography. The sciatic nerve was electrically stimulated using a custom-developed nerve holder with embedded electrodes for 1 h, followed by a 1-h recovery period, delivered at above-threshold Shannon model k -values in experimental groups: sham control (SC, n = 5 , 0.0 mA / 0 Hz ), stimulation level 1 (SL1, n = 5 , 3.4 mA / 50 Hz , and k = 2.57 ), and stimulation level 2 (SL2, n = 5 , 6.8 mA / 100 Hz , and k = 3.17 ). Results: The stimulation and imaging system successfully captured study data across the cohort. When compared to a SC after a 1-week recovery, the fascicle closest to the stimulation lead showed an average change of + 4 % / - 309 % (SL1/SL2) in phase retardation and - 79 % / - 148 % in optical attenuation relative to SC. Analysis of immunohistochemistry (IHC) shows a + 1 % / - 36 % difference in myelin pixel counts and - 13 % / + 29 % difference in axon pixel counts, and an overall increase in cell nuclei pixel count of + 20 % / + 35 % . These metrics were consistent with IHC and hematoxylin/eosin tissue section analysis. Conclusions: The poststimulation changes observed in our study are manifestations of nerve injury and repair, specifically degeneration and angiogenesis. Optical imaging metrics quantify these processes and may help evaluate the safety and efficacy of neuromodulation devices.

5.
Biomed Opt Express ; 14(2): 815-833, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36874491

RESUMO

Objective quantification of photoreceptor cell morphology, such as cell diameter and outer segment length, is crucial for early, accurate, and sensitive diagnosis and prognosis of retinal neurodegenerative diseases. Adaptive optics optical coherence tomography (AO-OCT) provides three-dimensional (3-D) visualization of photoreceptor cells in the living human eye. The current gold standard for extracting cell morphology from AO-OCT images involves the tedious process of 2-D manual marking. To automate this process and extend to 3-D analysis of the volumetric data, we propose a comprehensive deep learning framework to segment individual cone cells in AO-OCT scans. Our automated method achieved human-level performance in assessing cone photoreceptors of healthy and diseased participants captured with three different AO-OCT systems representing two different types of point scanning OCT: spectral domain and swept source.

6.
J Biomed Opt ; 28(2): 026002, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36785561

RESUMO

Significance: Modern optical volumetric imaging modalities, such as optical coherence tomography (OCT), provide enormous information about the structure, function, and physiology of living tissue. Although optical imaging achieves lateral resolution on the order of the wavelength of light used, and OCT achieves axial resolution on a similar micron scale, tissue optical properties, particularly high scattering and absorption, limit light penetration to only a few millimeters. In addition, in vivo imaging modalities are susceptible to significant motion artifacts due to cardiac and respiratory function. These effects limit access to artifact-free optical measurements during peripheral neurosurgery to only a portion of the exposed nerve without further modification to the procedure. Aim: We aim to improve in vivo OCT imaging during peripheral neurosurgery in small and large animals by increasing the amount of visualized nerve volume as well as suppressing motion of the imaged area. Approach: We designed a nerve holder with embedded mirror prisms for peripheral nerve volumetric imaging as well as a specific beam steering strategy to acquire prism and direct view volumes in one session with minimal motion artifacts. Results: The axially imaged volumes from mirror prisms increased the OCT signal intensity by > 22 dB over a 1.25-mm imaging depth in tissue-mimicking phantoms. We then demonstrated the new imaging capabilities in visualizing peripheral nerves from direct and side views in living rats and minipigs using a polarization-sensitive OCT system. Prism views have shown nerve fascicles and vasculature from the bottom half of the imaged nerve which was not visible in direct view. Conclusions: We demonstrated improved OCT imaging during neurosurgery in small and large animals by combining the use of a prism nerve holder with a specifically designed beam scanning protocol. Our strategy can be applied to existing OCT imaging systems with minimal hardware modification, increasing the nerve tissue volume visualized. Enhanced imaging depth techniques may lead to a greater adoption of structural and functional optical biomarkers in preclinical and clinical medicine.


Assuntos
Tecido Nervoso , Disco Óptico , Suínos , Animais , Ratos , Tomografia de Coerência Óptica/métodos , Porco Miniatura , Imagens de Fantasmas
7.
Commun Biol ; 5(1): 893, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-36100689

RESUMO

Choroideremia is an X-linked, blinding retinal degeneration with progressive loss of photoreceptors, retinal pigment epithelial (RPE) cells, and choriocapillaris. To study the extent to which these layers are disrupted in affected males and female carriers, we performed multimodal adaptive optics imaging to better visualize the in vivo pathogenesis of choroideremia in the living human eye. We demonstrate the presence of subclinical, widespread enlarged RPE cells present in all subjects imaged. In the fovea, the last area to be affected in choroideremia, we found greater disruption to the RPE than to either the photoreceptor or choriocapillaris layers. The unexpected finding of patches of photoreceptors that were fluorescently-labeled, but structurally and functionally normal, suggests that the RPE blood barrier function may be altered in choroideremia. Finally, we introduce a strategy for detecting enlarged cells using conventional ophthalmic imaging instrumentation. These findings establish that there is subclinical polymegathism of RPE cells in choroideremia.


Assuntos
Coroideremia , Degeneração Retiniana , Corioide/diagnóstico por imagem , Coroideremia/genética , Coroideremia/patologia , Feminino , Humanos , Masculino , Óptica e Fotônica , Células Fotorreceptoras Retinianas Cones , Degeneração Retiniana/patologia
8.
Biomed Opt Express ; 13(11): 5860-5878, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36733751

RESUMO

We describe the design and performance of a multimodal and multifunctional adaptive optics (AO) system that combines scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) for simultaneous retinal imaging at 13.4 Hz. The high-speed AO-OCT channel uses a 3.4 MHz Fourier-domain mode-locked (FDML) swept source. The system achieves exquisite resolution and sensitivity for pan-macular and transretinal visualization of retinal cells and structures while providing a functional assessment of the cone photoreceptors. The ultra-high speed also enables wide-field scans for clinical usability and angiography for vascular visualization. The FDA FDML-AO system is a powerful platform for studying various retinal and neurological diseases for vision science research, retina physiology investigation, and biomarker development.

9.
Invest Ophthalmol Vis Sci ; 62(13): 2, 2021 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-34605879

RESUMO

Purpose: The purpose of this study was to characterize the relationship between retinal ganglion cell layer (GCL) soma density and capillary density in glaucomatous eyes. Methods: Six glaucoma subjects with known hemifield defects and 6 age-matched controls were imaged with adaptive optics - optical coherence tomography (AO-OCT) at 6 locations: 3 degrees, 6 degrees, and 12 degrees temporal to the fovea above and below the midline. GCL soma density and capillary density were measured at each location. Coefficients of determination (pseudo R2) and slopes between GCL soma and capillary density were determined from mixed-effects regressions and were compared between glaucoma and control subjects, between more and less affected hemifield in subjects with glaucoma, and between subjects with early and moderate glaucoma, both in a local, bivariate model and then a global, multivariable model controlling for eccentricity and soma size. Results: The global correlation between GCL soma and capillary density was stronger in control versus subjects with glaucoma (R2 = 0.59 vs. 0.22), less versus more affected hemifields (R2 = 0.55 vs. 0.01), and subjects with early versus moderate glaucoma subjects (R2 = 0.44 vs. 0.18). When controlling for eccentricity and soma size, we noted an inverse soma-capillary density local relationship in subjects with glaucoma (-388 ± 190 cells/mm2 per 1% change in capillary density, P = 0.046) and more affected hemifields (-602 ± 257 cells/mm2 per 1% change in capillary density, P = 0.03). Conclusions: An inverted soma-capillary density local relationship in areas affected by glaucoma potentially explains weaker global correlations observed between GCL soma and capillary density, suggesting cell-vessel mismatch is associated with the disease.


Assuntos
Glaucoma/diagnóstico , Densidade Microvascular/fisiologia , Disco Óptico/irrigação sanguínea , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Campos Visuais/fisiologia , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia
10.
Biomed Opt Express ; 12(3): 1449-1466, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33796365

RESUMO

In vivo imaging of human retinal pigment epithelial (RPE) cells has been demonstrated through multiple adaptive optics (AO)-based modalities. However, whether consistent and complete information regarding the cellular structure of the RPE mosaic is obtained across these modalities remains uncertain due to limited comparisons performed in the same eye. Here, an imaging platform combining multimodal AO-scanning light ophthalmoscopy (AO-SLO) with AO-optical coherence tomography (AO-OCT) is developed to make a side-by-side comparison of the same RPE cells imaged across four modalities: AO-darkfield, AO-enhanced indocyanine green (AO-ICG), AO-infrared autofluorescence (AO-IRAF), and AO-OCT. Co-registered images were acquired in five subjects, including one patient with choroideremia. Multimodal imaging provided multiple perspectives of the RPE mosaic that were used to explore variations in RPE cell contrast in a subject-, location-, and even cell-dependent manner. Estimated cell-to-cell spacing and density were found to be consistent both across modalities and with normative data. Multimodal images from a patient with choroideremia illustrate the benefit of using multiple modalities to infer the cellular structure of the RPE mosaic in an affected eye, in which disruptions to the RPE mosaic may locally alter the signal strength, visibility of individual RPE cells, or even source of contrast in unpredictable ways.

11.
Neurophotonics ; 8(2): 025006, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33912621

RESUMO

Significance: Diffuse correlation spectroscopy (DCS) is an emerging noninvasive, diffuse optical modality that purportedly enables direct measurements of microvasculature blood flow. Functional optical coherence tomography angiography (OCT-A) can resolve blood flow in vessels as fine as capillaries and thus has the capability to validate key attributes of the DCS signal. Aim: To characterize activity in cortical vasculature within the spatial volume that is probed by DCS and to identify populations of blood vessels that are most representative of the DCS signals. Approach: We performed simultaneous measurements of somatosensory-evoked cerebral blood flow in mice in vivo using both DCS and OCT-A. Results: We resolved sensory-evoked blood flow in the somatosensory cortex with both modalities. Vessels with diameters smaller than 10 µ m featured higher peak flow rates during the initial poststimulus positive increase in flow, whereas larger vessels exhibited considerably larger magnitude of the subsequent undershoot. The simultaneously recorded DCS waveforms correlated most highly with flow in the smallest vessels, yet featured a more prominent undershoot. Conclusions: Our direct, multiscale, multimodal cross-validation measurements of functional blood flow support the assertion that the DCS signal preferentially represents flow in microvasculature. The significantly greater undershoot in DCS, however, suggests a more spatially complex relationship to flow in cortical vasculature during functional activation.

12.
Front Aging Neurosci ; 13: 629214, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33767618

RESUMO

Dark cone photoreceptors, defined as those with diminished or absent reflectivity when observed with adaptive optics (AO) ophthalmoscopy, are increasingly reported in retinal disorders. However, their structural and functional impact remain unclear. Here, we report a 3-year longitudinal study on a patient with oligocone trichromacy (OT) who presented with persistent, widespread dark cones within and near the macula. Diminished electroretinogram (ERG) cone but normal ERG rod responses together with normal color vision confirmed the OT diagnosis. In addition, the patient had normal to near normal visual acuity and retinal sensitivity. Occasional dark gaps in the photoreceptor layer were observed on optical coherence tomography, in agreement with reflectance AO scanning light ophthalmoscopy, which revealed that over 50% of the cones in the fovea were dark, increasing to 74% at 10° eccentricity. In addition, the cone density was 78% lower than normal histologic value at the fovea, and 20-40% lower at eccentricities of 5-15°. Interestingly, color vision testing was near normal at locations where cones were predominantly dark. These findings illustrate how a retina with predominant dark cones that persist over at least 3 years can support near normal central retinal function. Furthermore, this study adds to the growing evidence that cones can continue to survive under non-ideal conditions.

13.
Invest Ophthalmol Vis Sci ; 62(3): 34, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33760041

RESUMO

Purpose: To characterize retinal ganglion cell morphological changes in patients with primary open-angle glaucoma associated with hemifield defect (HD) using adaptive optics-optical coherence tomography (AO-OCT). Methods: Six patients with early to moderate primary open-angle glaucoma with an average age of 58 years associated with HD and six age-matched healthy controls with an average age of 61 years were included. All participants underwent in vivo retinal ganglion cell (RGC) imaging at six primary locations across the macula with AO-OCT. Ganglion cell layer (GCL) somas were manually counted, and morphological parameters of GCL soma density, size, and symmetry were calculated. RGC cellular characteristics were correlated with functional visual field measurements. Results: GCL soma density was 12,799 ± 7747 cells/mm2, 9370 ± 5572 cells/mm2, and 2134 ± 1494 cells/mm2 at 3°, 6°, and 12°, respectively, in glaucoma patients compared with 25,058 ± 4649 cells/mm2, 15,551 ± 2301 cells/mm2, and 3891 ± 1105 cells/mm2 (P < 0.05 for all locations) at the corresponding retinal locations in healthy participants. Mean soma diameter was significantly larger in glaucoma patients (14.20 ± 2.30 µm) compared with the health controls (12.32 ± 1.94 µm, P < 0.05 for all locations); symmetry was 0.36 ± 0.32 and 0.86 ± 0.13 in glaucoma and control cohorts, respectively. Conclusions: Glaucoma patients had lower GCL soma density and symmetry, greater soma size, and increased variation of GCL soma reflectance compared with age-matched control subjects. The morphological changes corresponded with HD, and the cellular level structural loss correlated with visual function loss in glaucoma. AO-based morphological parameters could be potential sensitive biomarkers for glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Células Ganglionares da Retina/patologia , Idoso , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais/fisiologia
14.
Optica ; 8(5): 642-651, 2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35174258

RESUMO

Cell-level quantitative features of retinal ganglion cells (GCs) are potentially important biomarkers for improved diagnosis and treatment monitoring of neurodegenerative diseases such as glaucoma, Parkinson's disease, and Alzheimer's disease. Yet, due to limited resolution, individual GCs cannot be visualized by commonly used ophthalmic imaging systems, including optical coherence tomography (OCT), and assessment is limited to gross layer thickness analysis. Adaptive optics OCT (AO-OCT) enables in vivo imaging of individual retinal GCs. We present an automated segmentation of GC layer (GCL) somas from AO-OCT volumes based on weakly supervised deep learning (named WeakGCSeg), which effectively utilizes weak annotations in the training process. Experimental results show that WeakGCSeg is on par with or superior to human experts and is superior to other state-of-the-art networks. The automated quantitative features of individual GCLs show an increase in structure-function correlation in glaucoma subjects compared to using thickness measures from OCT images. Our results suggest that by automatic quantification of GC morphology, WeakGCSeg can potentially alleviate a major bottleneck in using AO-OCT for vision research.

15.
JAMA Ophthalmol ; 139(1): 113-118, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33211074

RESUMO

In April 2019, the US Food and Drug Administration, in conjunction with 11 professional ophthalmic, vision science, and optometric societies, convened a forum on laser-based imaging. The forum brought together the Food and Drug Administration, clinicians, researchers, industry members, and other stakeholders to stimulate innovation and ensure that patients in the US are the first in the world to have access to high-quality, safe, and effective medical devices. This conference focused on the technology, clinical applications, regulatory issues, and reimbursement issues surrounding innovative ocular imaging modalities. Furthermore, the emerging role of artificial intelligence in ophthalmic imaging was reviewed. This article summarizes the presentations, discussion, and future directions.


Assuntos
Oftalmopatias/diagnóstico por imagem , Olho/diagnóstico por imagem , Lasers , Oftalmoscópios , Oftalmoscopia , Avaliação da Tecnologia Biomédica , Tomografia de Coerência Óptica/instrumentação , Inteligência Artificial , Difusão de Inovações , Humanos , Interpretação de Imagem Assistida por Computador , Lasers/efeitos adversos , Oftalmoscópios/efeitos adversos , Oftalmoscopia/efeitos adversos , Segurança do Paciente , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Tomografia de Coerência Óptica/efeitos adversos , Estados Unidos , United States Food and Drug Administration
16.
Artigo em Inglês | MEDLINE | ID: mdl-38261806

RESUMO

Silk fibroin with its attractive combination of advanced properties is promising for regenerative treatments of corneal disorders. Novel photonics approach is used to characterize the thickness and refractive index of silk fibroin thin films photo-crosslinked with a natural photosensitizer Riboflavin.

17.
Proc Natl Acad Sci U S A ; 117(48): 30661-30669, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33168747

RESUMO

Microglia are resident central nervous system macrophages and the first responders to neural injury. Until recently, microglia have been studied only in animal models with exogenous or transgenic labeling. While these studies provided a wealth of information on the delicate balance between neuroprotection and neurotoxicity within which these cells operate, extrapolation to human immune function has remained an open question. Here we examine key characteristics of retinal macrophage cells in live human eyes, both healthy and diseased, with the unique capabilities of our adaptive optics-optical coherence tomography approach and owing to their propitious location above the inner limiting membrane (ILM), allowing direct visualization of cells. Our findings indicate that human ILM macrophage cells may be distributed distinctly, age differently, and have different dynamic characteristics than microglia in other animals. For example, we observed a macular pattern that was sparse centrally and peaked peripherally in healthy human eyes. Moreover, human ILM macrophage density decreased with age (∼2% of cells per year). Our results in glaucomatous eyes also indicate that ILM macrophage cells appear to play an early and regionally specific role of nerve fiber layer phagocytosis in areas of active disease. While we investigate ILM macrophage cells distinct from the larger sample of overall retinal microglia, the ability to visualize macrophage cells without fluorescent labeling in the live human eye represents an important advance for both ophthalmology and neuroscience, which may lead to novel disease biomarkers and new avenues of exploration in disease progression.


Assuntos
Macrófagos/metabolismo , Imagem Molecular , Imagem Óptica , Retina/metabolismo , Retina/patologia , Biomarcadores , Suscetibilidade a Doenças , Glaucoma/diagnóstico , Glaucoma/etiologia , Glaucoma/metabolismo , Humanos , Macrófagos/imunologia , Macula Lutea/metabolismo , Microglia/imunologia , Microglia/metabolismo , Microglia/patologia , Imagem Molecular/métodos , Neuroproteção , Imagem Óptica/métodos , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica
18.
Am J Ophthalmol Case Rep ; 19: 100757, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32551400

RESUMO

PURPOSE: To determine the axial location of Gunn's dots in the retina. METHODS: Adaptive optics scanning laser ophthalmoscopy (AOSLO) images and adaptive optics - optical coherence tomography (AO-OCT) volumes were collected from a region where Gunn's dots were found inferior to the optic disc from a subject determined by clinical examination to be a glaucoma suspect. AO-OCT volumes were also collected along the horizontal and vertical meridians from six healthy subjects and one glaucoma subject to identify and document other occurrences of Gunn's dots. AO-OCT volumes were registered in three-dimensions and averaged. Gunn's dots were segmented, and their volume, area, and diameter were measured. RESULTS: All Gunn's dots imaged in this study from all subjects were confined to the inner limiting membrane, neither extending into the vitreous nor into the nerve fiber layer. The size of the dots was highly variable. The measured volume, area, and diameter (mean ± standard deviation) were 1119.9 ± 590.9 µm3, 220.2 ± 105.5 µm2, and 14.3 ± 3.1 µm, the latter within the range as previously published reports. CONCLUSIONS: Based upon evidence from this study and others, Gunn's dots are not thought to be Müller cell end-feet or hyalocytes. We hypothesize that they are related to microglia, either as the by-product of their phagocytosis function, or are actual dead ameboid-shaped microglia who have fulfilled their scavenger role in retinal pathology. Further studies are needed in diseased eyes to determine if they have predictive value.

19.
Biomaterials ; 238: 119831, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32045783

RESUMO

Implanted microelectrode arrays sense local neuronal activity, signals which are used as control commands for brain computer interface (BCI) technology. Patients with tetraplegia have used BCI technology to achieve an extraordinary degree of interaction with their local environment. However, current microelectrode arrays for BCIs lose the ability to record high-quality neural signals in the months-to-years following implantation. Very little is known regarding the dynamic response of neurons and vasculature in the months following electrode array implantation, but loss of structural integrity near the electrode may contribute to the degradation of recording signals. Here, we use in-vivo dual-modality imaging to characterize neuronal and vasculature structures in the same animal for 3 months following electrode insertion. We find ongoing neuronal atrophy, but relative vascular stability, in close proximity to the electrode, along with evidence suggesting links between rare, abrupt hypoxic events and neuronal process atrophy.


Assuntos
Neurônios , Animais , Eletrodos Implantados , Humanos , Microeletrodos
20.
Neurophotonics ; 7(1): 015004, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32042853

RESUMO

Significance: Cortically implanted microelectrode arrays provide a direct interface with neuronal populations and are used to restore movement capabilities and provide sensory feedback to patients with paralysis or amputation. Penetrating electrodes experience high rates of signal degradation within the first year that limit effectiveness and lead to eventual device failure. Aim: To assess vascular and neuronal changes over time in mice with implanted electrodes and examine the contribution of the brain tissue response to electrode performance. Approach: We used a multimodal approach combining in vivo electrophysiology and subcellular-level optical imaging. Results: At acute timescales, we observed structural damage from the mechanical trauma of electrode insertion, evidenced by severed dendrites in the electrode path and local hypofluorescence. Superficial vessel growth and remodeling occurred within the first few weeks in both electrode-implanted and window-only animals, but the deeper capillary growth evident in window-only animals was suppressed in electrode-implanted animals. After longer implantation periods, there was evidence of degeneration of transected dendrites superficial to the electrode path and localized neuronal cell body loss, along with deep vascular velocity changes near the electrode. Total spike rate (SR) across all animals reached a peak between 3 and 9 months postimplantation, then decreased. The local field potential signal remained relatively constant for up to 6 months, particularly in the high-gamma band, indicating long-term electrode viability and neuronal functioning at further distances from the electrode, but it showed a reduction in some animals at later time points. Most importantly, we found that progressive high-gamma and SR reductions both correlate positively with localized cell loss and decreasing capillary density within 100 µ m of the electrode. Conclusions: This multifaceted approach provided a more comprehensive picture of the ongoing biological response at the brain-electrode interface than can be achieved with postmortem histology alone and established a real-time relationship between electrophysiology and tissue damage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...