Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(6): 063523, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243539

RESUMO

A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system's rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.

2.
Rev Sci Instrum ; 91(6): 063505, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32611053

RESUMO

The design and evaluation of the Langmuir probe system used in the first divertor operation phase of Wendelstein 7-X is described. The probes are integrated into the target plates and have individually facetted surfaces to keep the angle of incidence of the magnetic field within an appropriate range for different magnetic configurations. Multiple models for the derivation of plasma parameters from current-voltage characteristics are introduced. These are analyzed with regard to their assumptions and limitations, generalized, and adapted to our use case. A detailed comparison is made to determine the most suitable model. It is found that the choice of model has a large impact, for example, resulting in a change in the inferred temperatures of up to a factor two. This evaluation is implemented in a Bayesian modeling framework and automated to allow for joint analysis with other diagnostics and a replacement of ad hoc assumptions. We rigorously treat parameter uncertainties, revealing strong correlations between them. General and flexible model formulations permit an expansion to additional effects.

3.
Phys Rev Lett ; 123(2): 025002, 2019 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-31386539

RESUMO

For the first time, the optimized stellarator Wendelstein 7-X has operated with an island divertor. An operation regime in hydrogen was found in which the total plasma radiation approached the absorbed heating power without noticeable loss of stored energy. The divertor thermography recorded simultaneously a strong reduction of the heat load on all divertor targets, indicating almost complete power detachment. This operation regime was stably sustained over several energy confinement times until the preprogrammed end of the discharge. The plasma radiation is mainly due to oxygen and is located at the plasma edge. This plasma scenario is reproducible and robust at various heating powers, plasma densities, and gas fueling locations. These experimental results show that the island divertor concept actually works and displays good power dissipation potential, producing a promising exhaust concept for the stellarator reactor line.

4.
Rev Sci Instrum ; 87(11): 11E119, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910425

RESUMO

An onion-peeling technique is developed for inferring the emissivity profile of a stellarator plasma from a two-dimensional image acquired through a CCD or CMOS camera. Each pixel in the image is treated as an integral of emission along a particular line-of-sight. Additionally, the flux surfaces in the plasma are partitioned into discrete layers, each of which is assumed to have uniform emissivity. If the topology of the flux surfaces is known, this construction permits the development of a system of linear equations that can be solved for the emissivity of each layer. We present initial results of this method applied to wide-angle visible images of the Columbia Neutral Torus (CNT) stellarator plasma.

5.
N J Med ; 97(5): 29-34, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10832363

RESUMO

The objective of our study was to evaluate the technical advantages of using the Laparolift device and examine the clinical benefits of gynecologic laparoscopy without pneumoperitoneum. A randomized single-blinded clinical trial was performed employing a sample of 30 consecutive patients undergoing laparoscopic gynecologic surgery with a primary outcome measure of visualization. Visualization was found to be inferior in gasless patients. The conclusion was that conventional laparoscopy employing pneumoperitoneum provides surgical exposure superior to that offered by the Laparolift device.


Assuntos
Doenças dos Genitais Femininos/cirurgia , Procedimentos Cirúrgicos em Ginecologia/métodos , Laparoscopia/métodos , Pneumoperitônio Artificial/métodos , Adulto , Dióxido de Carbono/administração & dosagem , Desenho de Equipamento , Feminino , Humanos , Método Simples-Cego , Resultado do Tratamento
6.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...