Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetologia ; 59(9): 1977-84, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27193916

RESUMO

AIMS/HYPOTHESIS: Type 2 diabetes is characterised by decreased HDL levels, as well as the level of apolipoprotein A-I (apoA-I), the main apolipoprotein of HDLs. Pharmacological elevation of HDL and apoA-I levels is associated with improved glycaemic control in patients with type 2 diabetes. This is partly due to improved glucose uptake in skeletal muscle. METHODS: This study used kinetic modelling to investigate the impact of increasing plasma apoA-I levels on the metabolism of glucose in the db/db mouse model. RESULTS: Treatment of db/db mice with apoA-I for 2 h significantly improved both glucose tolerance (AUC 2574 ± 70 mmol/l × min vs 2927 ± 137 mmol/l × min, for apoA-I and PBS, respectively; p < 0.05) and insulin sensitivity (AUC 388.8 ± 23.8 mmol/l × min vs 194.1 ± 19.6 mmol/l × min, for apoA-I and PBS, respectively; p < 0.001). ApoA-I treatment also increased glucose uptake by skeletal muscle in both an insulin-dependent and insulin-independent manner as evidenced by increased uptake of fludeoxyglucose ([(18)F]FDG) from plasma into gastrocnemius muscle in apoA-I treated mice, both in the absence and presence of insulin. Kinetic modelling revealed an enhanced rate of insulin-mediated glucose phosphorylation (k 3) in apoA-I treated mice (3.5 ± 1.1 × 10(-2) min(-1) vs 2.3 ± 0.7 × 10(-2) min(-1), for apoA-I and PBS, respectively; p < 0.05) and an increased influx constant (3.7 ± 0.6 × 10(-3) ml min(-1) g(-1) vs 2.0 ± 0.3 × 10(-3) ml min(-1) g(-1), for apoA-I and PBS, respectively; p < 0.05). Treatment of L6 rat skeletal muscle cells with apoA-I for 2 h indicated that increased hexokinase activity mediated the increased rate of glucose phosphorylation. CONCLUSIONS/INTERPRETATION: These findings indicate that apoA-I improves glucose disposal in db/db mice by improving insulin sensitivity and enhancing glucose phosphorylation.


Assuntos
Apolipoproteína A-I/uso terapêutico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Fluordesoxiglucose F18/análise , Glucose/metabolismo , Músculo Esquelético/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Animais , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 2/sangue , Modelos Animais de Doenças , Resistência à Insulina/fisiologia , Cinética , Masculino , Camundongos , Músculo Esquelético/efeitos dos fármacos , Fosforilação/efeitos dos fármacos
2.
Phys Med Biol ; 61(3): 1371-88, 2016 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26797268

RESUMO

In PET imaging, research groups have recently proposed different experimental set ups allowing multiple animals to be simultaneously imaged in a scanner in order to reduce the costs and increase the throughput. In those studies, the technical feasibility was demonstrated and the signal degradation caused by additional mice in the FOV characterized, however, the impact of the signal degradation on the outcome of a PET study has not yet been studied. Here we thoroughly investigated, using Monte Carlo simulated [18F]FDG and [11C]Raclopride PET studies, different experimental designs for whole-body and brain acquisitions of two mice and assessed the actual impact on the detection of biological variations as compared to a single-mouse setting. First, we extended the validation of the PET-SORTEO Monte Carlo simulation platform for the simultaneous simulation of two animals. Then, we designed [18F]FDG and [11C]Raclopride input mouse models for the simulation of realistic whole-body and brain PET studies. Simulated studies allowed us to accurately estimate the differences in detection between single- and dual-mode acquisition settings that are purely the result of having two animals in the FOV. Validation results showed that PET-SORTEO accurately reproduced the spatial resolution and noise degradations that were observed with actual dual phantom experiments. The simulated [18F]FDG whole-body study showed that the resolution loss due to the off-center positioning of the mice was the biggest contributing factor in signal degradation at the pixel level and a minimal inter-animal distance as well as the use of reconstruction methods with resolution modeling should be preferred. Dual mode acquisition did not have a major impact on ROI-based analysis except in situations where uptake values in organs from the same subject were compared. The simulated [11C]Raclopride study however showed that dual-mice imaging strongly reduced the sensitivity to variations when mice were positioned side-by-side while no sensitivity reduction was observed when they were facing each other. This is the first study showing the impact of different experimental designs for whole-body and brain acquisitions of two mice on the quality of the results using Monte Carlo simulated [18F]FDG and [11C]Raclopride PET studies.


Assuntos
Algoritmos , Tomografia por Emissão de Pósitrons/métodos , Animais , Fluordesoxiglucose F18/farmacocinética , Camundongos , Modelos Teóricos , Tomografia por Emissão de Pósitrons/instrumentação , Racloprida/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética
3.
Neuroimage ; 118: 484-93, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26080302

RESUMO

Quantitative measurements in dynamic PET imaging are usually limited by the poor counting statistics particularly in short dynamic frames and by the low spatial resolution of the detection system, resulting in partial volume effects (PVEs). In this work, we present a fast and easy to implement method for the restoration of dynamic PET images that have suffered from both PVE and noise degradation. It is based on a weighted least squares iterative deconvolution approach of the dynamic PET image with spatial and temporal regularization. Using simulated dynamic [(11)C] Raclopride PET data with controlled biological variations in the striata between scans, we showed that the restoration method provides images which exhibit less noise and better contrast between emitting structures than the original images. In addition, the method is able to recover the true time activity curve in the striata region with an error below 3% while it was underestimated by more than 20% without correction. As a result, the method improves the accuracy and reduces the variability of the kinetic parameter estimates calculated from the corrected images. More importantly it increases the accuracy (from less than 66% to more than 95%) of measured biological variations as well as their statistical detectivity.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Tomografia por Emissão de Pósitrons/métodos , Animais , Humanos , Método de Monte Carlo , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA