Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Zhongguo Zhong Yao Za Zhi ; 47(10): 2738-2749, 2022 May.
Artigo em Chinês | MEDLINE | ID: mdl-35718494

RESUMO

This study aims to explore the mechanism of Astragali Radix-Puerariae Lobatae Radix(AP) combination in the treatment of type 2 diabetes mellitus(T2 DM) based on network pharmacology and experiment. The effective components and targets of the pair were retrieved from the Traditional Chinese Medicine Systems Pharmacology Database and Analysis Platform(TCMSP) and targets of T2 DM from each disease database. On this basis, the common targets of the medicinals and the disease were screened out. The protein-protein interaction(PPI) network was established based on STRING. Then Cytoscape 3.7.1 was employed for visualization of the common targets and the network topology analysis of key targets, followed by Gene Ontology(GO) term enrichment and Kyoto Encyclopedia of Genes and Genomes(KEGG) pathway enrichment of core targets by DAVID. Thereby, the possible molecular mechanism was unveiled. High-fat diet was combined with streptozotocin(STZ, injected into tail vein) for T2 DM rat modeling. Rats were classified into the normal group, model group, positive control group(metformin hydrochloride), AP high-dose, medium-dose, and low-dose groups. After 4 weeks of intragastric administration, serum fasting blood glucose(FBG), fasting insulin(FINS), aspartate aminotransferase(AST), alanine aminotransferase(ALT), triglyceride(TG), total cholesterol(TC), low-density lipoprotein cholesterol(LDL-C), high-density lipoprotein cholesterol(HDL-C), interleukin(IL)-6, and tumor necrosis factor(TNF)-α of rats in each group were measured. The expression of insulin receptor substrate-2(IRS-2), adenosine monophosphate-activated protein kinase(AMPK), phosphorylated AMPK(p-AMPK), glucose 6 phosphatase(G6 Pase), and phosphoenolpyruvate carboxy kinase(Pepck) in rat liver was detected by Western blot. A total of 131 core targets of the combination in the treatment of T2 DM were screened out, among which protein kinase B(AKT) 1, mitogen-activated protein kinase(MAPK) 1, TNF-α, IL-6 were more critical. KEGG enrichment analysis suggested that the combination decreased blood glucose mainly through PI3 K/AKT signaling pathway, AMPK signaling pathway, TNF signaling pathway, and MAPK signaling pathway. The levels of FBG and FINS were lower and the glycogen level was higher in the AP high-dose and medium-dose groups than in the model group. The levels of AST, ALT, TG, and LDL-C in the three AP groups and the level of TC in AP high-dose and low-dose groups decreased compared with those in the model group. Levels of IL-6 and TNF-α were lower in AP high-dose and medium-dose groups than in the model group. The expression of IRS-2, AMPK, and p-AMPK was higher and that of G6 Pase and Pepck was lower in AP high-dose group than in the model group. Thus, the combination had multi-component, multi-target, and multi-pathway characteristics in the treatment of T2 DM. It may regulate AMPK signaling pathway through IL-6 and TNF-α to influence insulin resistance, glycogen synthesis, gluconeogenesis, islet ß cell transport, and inflammatory response, thereby exerting therapeutic effect on T2 DM.


Assuntos
Astrágalo , Diabetes Mellitus Tipo 2 , Medicamentos de Ervas Chinesas , Pueraria , Proteínas Quinases Ativadas por AMP/genética , Proteínas Quinases Ativadas por AMP/metabolismo , Animais , Astrágalo/metabolismo , Glicemia/metabolismo , LDL-Colesterol/uso terapêutico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Medicamentos de Ervas Chinesas/farmacologia , Medicamentos de Ervas Chinesas/uso terapêutico , Glicogênio/uso terapêutico , Interleucina-6/genética , Farmacologia em Rede , Proteínas Proto-Oncogênicas c-akt/metabolismo , Ratos , Transdução de Sinais , Estreptozocina/uso terapêutico , Fator de Necrose Tumoral alfa
2.
J Int Med Res ; 48(4): 300060519894790, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31884845

RESUMO

OBJECTIVE: To examine the clinical effect of computed tomography angiography (CTA) on parameters of intracranial aneurysms in different locations and with different sizes using digital subtraction angiography (DSA) as the standard. METHODS: Patients with intracranial aneurysms who underwent CTA examinations at the same center and received DSA examinations within 3 days were analyzed retrospectively. The morphological parameters of the aneurysms and parent arteries were measured with these two methods. RESULTS: Mean aneurysm size and parent artery diameter were not different between CTA and DSA. The size of microaneurysms was significantly smaller with DSA than with CTA. The aneurysmal neck width was not different between CTA and DSA. DSA could clearly evaluate the relationship between the aneurysmal neck and the parent artery in all cases. However, CTA had a 90% accuracy rate of visualizing this relationship. CONCLUSION: The accuracy rates of evaluating aneurysm size and the aneurysmal neck width and parent artery diameter are similar between CTA and DSA. A DSA examination is essential for evaluating the relationship among microaneurysms, the aneurysmal neck, and the parent artery. CTA is widely applied and more safe in clinical practice, while DSA has a better guiding effect than CTA for some complicated aneurysms.


Assuntos
Aneurisma Intracraniano , Angiografia Digital , Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Shanghai Kou Qiang Yi Xue ; 19(2): 187-91, 2010 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-20485985

RESUMO

PURPOSE: To evaluate the efficiency of self-made paste on gingival retraction in dogs as well as its potential clinical application. METHODS: Forty teeth from two mature dogs were prepared with 0.5 mm wide shoulder in the lip and buccal sides of the teeth, and then divided into four groups randomly. The gingival grooves of the four groups were filled with self-made colloid paste, Expasyl gingival retraction paste, gingival retraction cord, and medicated (15.5% Fe2SO4 solution) gingival retraction cord, respectively. The gingival grooves models before and after gingival retraction were analyzed using the image precise mapper instrument; the gingival width and height of the gingival groove were compared using SAS6.12 software package. RESULTS: The changes of gingival width of the gingival groove before and after gingival retraction were not significant between the four groups. However, the gingival height of the gingival groove in the medicated gingival retraction cord group increased significantly [(0.423 + or - 0.348) mm before gingival retraction and (0.623 + or - 0.278) mm after gingival retraction] compared with the other three groups. CONCLUSIONS: The self-made colloid paste for gingival retraction is efficient like Expasyl gingival retraction paste and gingival retraction cord with potential clinical application, while the medicated gingival retraction cord can induce gingival shrinkage. Supported by Research Fund of Science and Technology Bureau of Huangpu District,Shanghai.


Assuntos
Gengiva , Pomadas , Animais , Coloides , Cães , Retração Gengival
5.
Shanghai Kou Qiang Yi Xue ; 19(2): 209-11, 2010 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-20485990

RESUMO

PURPOSE: To investigate the adequate luting cements for zirconia ceramics to dentin. METHODS: Blocks of sintered zirconia ceramics were randomly divided into 4 groups with 8 slices in each. After saliva immersion,airborne-particle abraded ceramic specimens were cleaned with phosphoric acid gel(containing 35% phosphoric acid) and then bonded to dentin with these four kinds of luting cements. After preserved in 37 degrees centigrade distilled water for 24 hours, the shear bonding strength of these specimens was tested and the data was analyzed with SPSS12.0 software package. RESULTS: The Multilink Automix could attain the highest shear bonding strength and the 3M RelyXTM Unicem AplicapTM could attain higher shear bonding strength, which were both significantly higher than in the Tokuso Ionomer and Shofu Polycarboxylate Cement groups(P<0.05). CONCLUSION: Total etching resin luting cement is an ideal option to the bonding of zirconia ceramics and can provide a strong bonding.


Assuntos
Cerâmica , Colagem Dentária , Cemento Dentário , Porcelana Dentária , Dentina , Cimentos de Ionômeros de Vidro , Humanos , Cimentos de Resina , Resistência ao Cisalhamento , Zircônio
6.
Shanghai Kou Qiang Yi Xue ; 18(3): 324-8, 2009 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-19649536

RESUMO

PURPOSE: To evaluate the stress distribution of mandibular second premolar restored with different shapes and diameters fiber post-core. METHODS: A load of 200N was distributed to the finite element model of mandibular second premolar restored with three different shapes (column post, cone post and trapezium post) and three different diameters(1/2,1/3 and 1/4 of root diameter) fiber post-core in vertical and lateral ( 45 degrees ) direction, and software of "Nastran" was applied to analyze the three-dimensional finite element distribution of stress respectively. RESULTS: Irrespective of the shapes, there was no significant change of stress distribution with the increase of post diameter. Under lateral load, the cone post and trapezium post created the least increased range of maximum stress than that under the vertical load. CONCLUSION: Cone and trapezium fiber posts are the more ideal designs to restore the residual crowns and roots.


Assuntos
Dente Pré-Molar , Técnica para Retentor Intrarradicular , Coroas , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Raiz Dentária
7.
Shanghai Kou Qiang Yi Xue ; 18(2): 198-202, 2009 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-19418000

RESUMO

PURPOSE: To investigate the effect of silica coating by sol-gel process on bonding strength of zirconia ceramics to dentin. METHODS: Blocks of sintered zirconia ceramics were cut and randomly divided into 4 groups,16 slices in each group. Each group was subject to one of the 4 kinds of surface treatment (control group, sandblasting, sandblasting +silicone, sandblasting + silica coating + silicone) and then bonded to dentin with resin cement. After preservation in 37 degrees centigrade distilled water for 24 hours, the shear bonding strength of these specimens was tested and the data was analyzed with SAS6.12 software package for analysis of variance. The surface modality of the ceramics was observed under scanning electron microscopy (SEM). RESULTS: The group of sandblasting+ silica coating + silicone attained the highest shear bonding strength, which was significantly different from the other groups(P=0.000);There was no significant difference between the sandblasting and sandblasting + silicone group (P=0.827), which was significantly different from the control group(P=0.001). CONCLUSION: Silica coating by sol-gel process, coupled with silicone, can significantly increase the bonding strength of zirconia ceramics to dentin.


Assuntos
Cerâmica , Dióxido de Silício , Colagem Dentária , Dentina , Humanos , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície , Água , Zircônio
8.
Zhen Ci Yan Jiu ; 34(6): 393-7, 2009 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-20209975

RESUMO

OBJECTIVE: To observe the effect of electroacupuncture (EA) of different acupoints on blood pressure (BP), plasma angiotensin (Ang) II, aldosterone (ALD) and atrial natriuretic peptide (ANP) of SHR, so as to observe the relative specificity of effects of acupoints. METHODS: A total of 60 SHR were randomly divided into model, Quchi (LI 11), Zusanli (ST 36), Shenmen (HT 7), Jianyu (LI 15) and non-acupoint groups, with 10 cases in each. Other 10 Wistar rats were composed of normal group. EA (2 Hz, 2 mA) was applied to LI 11, ST 36, HT 7, LI 15 and non-acupoint for 30 min, followed by measuring BP with BP-6 system. Plasma Ang II, ALD and ANP contents were assayed by radioimmunoassay. RESULTS: Compared with control group and pre-treatment, both systolic pressure (SP) and diastolic pressure (DP) of Quchi (LI 11), Zusanli (ST 36) and Shenmen (HT 7) groups lowered significantly (P<0.05). No significant differences were found in the SP and DP of Jianyu (LI 15) and non-acupoint groups (P>0.05). After EA, the SP of Quchi (LI 11) and Shenmen (HT 7) groups were significantly lower than that of Jianyu (LI 15) and non-acupoint groups (P<0.05); and the DP of Quchi (LI 11), Zusanli (ST 36) and Shenmen (HT 7) groups were markedly lower than that of Jianyu (LI 15) and non-acupoint groups (P<0.05). Compared with normal group, the contents of plasma Ang II and ANP of model group decreased significantly, and plasma ALD level of model group increased remarkably (P<0.05). Compared with model group, plasma AngII levels in Quchi (LI 11), Zusanli (ST 36) and Shenmen (HT 7) groups and ALD in Zusanli (ST 36) and Shenmen (HT 7) groups lowered significantly (P<0.05), and plasma ANP content in Shenmen (HT 7) group increased obviously (P<0.05). CONCLUSION: EA of LI 11, HT 7 and ST 36 can effectively lowered both DP and SP in SHR, which may be closely related to its effects in regulating the contents of Ang II , ALD and ANP.


Assuntos
Aldosterona/sangue , Angiotensina II/sangue , Fator Natriurético Atrial/sangue , Pressão Sanguínea , Eletroacupuntura , Hipertensão/terapia , Pontos de Acupuntura , Animais , Modelos Animais de Doenças , Humanos , Hipertensão/sangue , Hipertensão/fisiopatologia , Masculino , Distribuição Aleatória , Ratos , Ratos Wistar
9.
Shanghai Kou Qiang Yi Xue ; 17(1): 88-91, 2008 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-18360677

RESUMO

PURPOSE: To study the effect of Streptococcus sanguis on corrosion resistance of magnetic retainers in which are encapsulated with stainless steel artificial saliva. METHODS: A magnetic retainer was put in one culture flask,which was filled with artificial saliva.Ten of them were added Streptococcus sanguis suspension,the others were added PBS as control.The culture flasks were cultivated in incubator(36 degrees centigrade). 5 ml suspension was dislodged from each flask at the 3rd, 10th and 20th day. The quantity of Fe(3+) and Mn(2+) was detected.Statistical analysis of paired t test was performed with SPSS10.0 software package. RESULTS: When Streptococcus sanguis existed, the quantity of Fe(3+) and Mn(2+) was significantly higher than that in the control (P<0.01). CONCLUSION: The existence of Streptococcus sanguis destroys the corrosion resistance of magnetic retainers remarkably.


Assuntos
Aparelhos Ortodônticos Removíveis , Streptococcus sanguis , Corrosão , Fenômenos Magnéticos , Magnetismo , Aço Inoxidável
10.
Shanghai Kou Qiang Yi Xue ; 16(1): 64-7, 2007 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-17377704

RESUMO

PURPOSE: To study the stress distribution of bone tissues around the abutments in telescope fixed bridge supported by tooth-implant. METHODS: A patient with loss of the left first mandibular molar was used as the subject. Two partial fixed denture models were established. One model (model I) was supported by the second premolar and implant in the second molar, the other model (model II) was supported by the second premolar and implant other than the second molar. Under decentralized vertical and oblique loads, the stress distribution of bone tissues around the tooth and implant was evaluated by three dimensional finite element analysis. RESULTS: Under decentralized vertical load, the max EQVs of the bone tissues around the tooth and implant in model I were 2.58MPa and 43.92MPa, and 2.17MPa and 20.23MPa in model II. Under decentralized oblique load, the max EQVs of the bone tissues around the tooth and implant in model I were 2.23MPa and 46.37MPa, and 1.91MPa and 21.19MPa in model II. CONCLUSIONS: The stress surrounding the implant is declined by the buffer of telescope retainer, and the decline is not different under the two loads. In designing the fixed bridge supported by tooth-implant, we can design telescope retainer on implant to reduce the stress of bone tissues around the implant and to prevent damages to bone tissues.


Assuntos
Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Análise de Elementos Finitos , Ligamento Periodontal , Dente Pré-Molar , Dente Suporte , Implantes Dentários , Prótese Parcial Fixa , Humanos , Imageamento Tridimensional , Dente Molar
11.
Shanghai Kou Qiang Yi Xue ; 16(1): 73-6, 2007 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-17377706

RESUMO

PURPOSE: To study the bonding strength of zirconia ceramics with 4 kinds of luting cement materials. METHODS: Blocks of sintered zirconia ceramics were cut and randomly divided into 4 groups with 16 slices in each group. They were treated with sandblasting and bonded with 4 kinds of luting cements respectively. After preserved in 37 degrees C distilled-water for 24 hours and 30 days, the shear bonding strength of these specimens was tested and the data were analyzed by SAS6.12 software package and bond section were observed by scanning electron microscope. RESULTS: Two-way ANOVA revealed that the group of PanaviaF could attain the highest shear bonding strength: (34.7+/-3.44) MPa (after 24 hours), (31.5+/-3.44) MPa (after 1 month), which was significantly different from other treatment methods (P<0.01). The initial shear bonding strength of the groups of resin-reinforced glass ionomer was (15.5+/-2.71) MPa, (16.0+/-1.77) MPa (after 24 hours) but dropped markedly to (6.80+/-1.24) MPa, (3.38+/-2.32) MPa after 30 days (P<0.05). CONCLUSIONS: Resin luting cement containing phosphate monomer (MDP) can provide zirconia ceramics a strong and long-lasting bonding. Resin-reinforced glass ionomer can get good bonding strength too, but can't last long.


Assuntos
Cerâmica/química , Colagem Dentária , Cimentos Dentários/química , Teste de Materiais , Resistência ao Cisalhamento , Zircônio/química , Cimentos de Ionômeros de Vidro , Cimentos de Resina , Propriedades de Superfície
12.
Shanghai Kou Qiang Yi Xue ; 15(2): 198-201, 2006 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-16685366

RESUMO

PURPOSE: To study the influence on the abutment movement with three kinds of precision attachments designed for distal-extension removable partial dentures (RPDs). METHODS: Snap attachment, Ceka attachment, Mini-SG attachment were used to retain RPDs. Then food chip was masticated between the upper and lower dentitions on the attachments side. Placement of abutment was measured by LB-72 high-sensitive-laser-traneferring-detector and the data were statistically analyzed for random block analysis of variance. RESULTS: The displacement, inclination, and torsion of the abutment movements in the mesial-distal, bucco-lingual and occluso-gingival directions all had statistical significance (P<0.05). The largest mesial-distal inclination occurred with the Mini-SG attachment. The Ceka attachment produced more abutment displacement in mesial distal and apical directions. Occlusal displacement and anti-clockwise rotation were the least with the Snap attachment. CONCLUSION: The most equitable distribution of stresses on the supporting structures was achieved by Snap attachment with its resilent assemble, Ceka attachment transfers most of the loading forces to the abutments, Mini-SG attachment can not reduce the excessive torque applied to the abutments effectively.


Assuntos
Dente Suporte , Encaixe de Precisão de Dentadura , Retenção de Dentadura , Prótese Parcial Removível , Análise do Estresse Dentário , Planejamento de Dentadura , Humanos , Dente
13.
Shanghai Kou Qiang Yi Xue ; 15(2): 206-9, 2006 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-16685368

RESUMO

PURPOSE: To compare the stress distributions of fixed bridge, cement-retained telescopic prostheses and extracoronal precision attachment (CEKA attachment) when connect the implants to the natural teeth, in order to find a more suitable design for it. METHODS: 3-D finite element models of tooth-implant partial fixed dentures were constructed by using the ANSYS software. The partial fixed denture was supported by the second premolar and an implant (substitute the second molar). A total load of 200N was distributed to the three units of the denture in vertical and lateral (45 degree) directions. RESULTS: Both of the cement-retained telescopic and the CEKA attachment made the stress of the osseous tissues surrounding the implant and the tooth declined obviously under the loads of the two directions. The stress of the cement-retained telescopic was lower under vertical load,the stress of Ceka attachment was lower under lateral load while it caused the stress of the natural tooth increasing slightly. The stress under the lateral load was higher than that under the vertical load. CONCLUSION: Both of the cement-retained telescopic and the CEKA attachment can improve the stress distribution of tooth-implant support denture. The CEKA attachment is better under lateral loads.


Assuntos
Força Compressiva , Implantes Dentários , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Dente Pré-Molar , Dente Suporte , Prótese Parcial Fixa , Humanos , Dente
14.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-337615

RESUMO

Hematopoietic stromal cells, being the essential ingredient of the hematopoietic microenvironment, play very important roles in the control and regulation of self-renewal, proliferation and differentiation of hematopoietic stem cells (HSC) via complex interactions of cell-cell, cell-humoral and cell-extracellular matrix. Evidence from in vivo experiment has proved that HSC derived from normal mice could reconstitute hematopoiesis of mice with HSC defects but failed to reconstitute hematopoiesis of those mice with microenvironment defects, showing the importance of hematopoietic microenvironment in the maintenance of hematopoiesis in vivo. A well-known long-term culture (LTC) system established by Dexter demonstrated in another way that stromal cell layer in the system could support ex vivo hematopoiesis for several months, even more than one year under the optimal conditions. It, however, has not been demonstrated that what is the key elements and in which way the ex vivo hematopoiesis could be maintained for so long time. As the inventions for the large-scale screening methodologies the suppression subtractive hybridization (SSH) was chosen for the screening differentially expressed genes expressed by LTC cultured stromal cells but not by the uncultured bone marrow cells (BMC). mRNA extracted from both cultured adherent cells (tester) and BMC (driver) were hybridized according to the protocol provided by CLONTECH. Total of 130 clones differentially expressed by cultured cells were randomly picked up and 106 ESTs were obtained after sequencing. They represent 26 identical or similar genes and 7 novel genes after the bioinformatics analysis. 5 of the novel genes with the entire open reading frame, without functional clues, have been cloned into the mammalian expression vectors and the functions of them in the control of proliferation and differentiation of HSC will be further exploring. The most interesting discovery is that 3 novel genes have signal peptides, implying the potential discovery of novel growth factors as 80% known growth factors have signal peptides. Our experimental results suggest that: (a) based on the results of subtractive efficiency, the SSH could be a reliable method to screen differentially expressed genes; (b) gene expression may be regulated by multiple factors, even conditioning-dependent, in this experiment the genes expressed by bone marrow stromal cells are LTC-cultivation inducible; (c) it is possible to find interesting genes or special gene after relatively large-scale screen.


Assuntos
Animais , Feminino , Masculino , Camundongos , Células Cultivadas , DNA Complementar , Genética , Metabolismo , Desoxirribonucleases de Sítio Específico do Tipo II , Metabolismo , Etiquetas de Sequências Expressas , Perfilação da Expressão Gênica , Células-Tronco Hematopoéticas , Biologia Celular , Metabolismo , Camundongos Endogâmicos BALB C , Reação em Cadeia da Polimerase , RNA Mensageiro , Genética , Metabolismo , Células Estromais , Biologia Celular , Metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...