1.
Sci Rep ; 13(1): 21297, 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38042836

RESUMO

Aerosol jet printing (AJP) is a new non-contact direct writing technique designed to achieve precise and intricate patterns on various substrates. Specifically, the pneumatic AJP process breaks down the ink into fine particles, significantly reducing the risk of nozzle clogging and rendering it highly advantageous for industrial applications. This paper focuses on the optimization of the line electrode formation process using soluble silver clusters as the conductive ink, along with the aerosol formation procedure. The main parameters of the AJP process, namely sheath flow rate, atomizer flow rate, and dispensing speed, were identified and examined for their influence on line width and resistivity. Through this analysis, an operability window, including optimized conditions for printing high-quality lines using the AJP process, was established, along with a regression equation enabling the statistical estimation of line width. In summary, the outcomes of this investigation underscore the feasibility of an integrated printing system capable of precision control over line width, achieved through the optimization of AJP process parameters. Furthermore, it was established that pneumatic AJP offers robust process stability. The practical applicability of the proposed optimization techniques was assessed, highlighting their potential utilization in electrode formation processes within the electronic and display industry.

2.
Sensors (Basel) ; 23(21)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37960648

RESUMO

We configured a long-distance ranging apparatus to test the principle of dual-comb time-of-flight measurement using ultrashort lasers. Emphasis was given to the evaluation of open-air performance quantitatively in terms of the measurement resolution and stability. The test results revealed that our dual-comb asynchronous optical pulse sampling permits micrometer-resolved ranging with a repeatability of 2.05 µm over a 648 m distance in dry weather conditions. Further atmospheric effects were evaluated in three different weather conditions with corresponding Allan deviations. Finally, the capability of simultaneous determination of multiple targets was verified with the potential of advanced industrial applications, such as manufacturing, surveying, metrology, and geodesy.

3.
Sensors (Basel) ; 20(24)2020 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-33353042

RESUMO

Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 µm, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 µm, while the maximum deviation estimated by the conventional self-calibration method was 711.9 µm. Validation of 3D coordinate measurements in a 1000 mm × 1000 mm × 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 µm. Conversely, the maximum difference was 98.8 µm using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.

4.
J Opt Soc Am A Opt Image Sci Vis ; 37(9): B27-B35, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32902417

RESUMO

Ultrashort pulse lasers are emerging as an advanced tool of distance measurement, with their unique temporal and spectral characteristics being extended to diverse principles of absolute ranging and instrumentation. Here, a systematic methodology is presented for absolute ranging by means of the time-of-flight measurement of ultrashort light pulses using dual-comb asynchronous optical sampling. Based on an elaborate uncertainty analysis, influencing system parameters such as the pulse duration, repetition rate, and averaging time are optimized to achieve a sub-µm measurement accuracy. The absolute ranging system developed in this study demonstrates a combined standard uncertainty of 0.986 µm for a 0.5 ms averaging over a distance range of 3.0 m, with a further reduction to 0.056 µm when the averaging time is increased to 0.5 s. The outstanding performance leads to unprecedented multitarget applications: machine feed control with thermal error compensation in real time as well as the nondestructive inspection of multilens assembly in a production line.

5.
Sci Rep ; 5: 15726, 2015 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-26503257

RESUMO

Femtosecond lasers allow for simultaneous detection of multiple absorption lines of a specimen over a broad spectral range of infrared or visible light with a single spectroscopic measurement. Here, we present an 8-THz bandwidth, 0.5-GHz resolution scheme of Fourier-transform spectroscopy using an Er-doped fiber femtosecond laser. A resolving power of 1.6 × 10(4) about a 1560-nm center wavelength is achieved by sweeping the pulse repetition rate of the light source on a fiber Mach-Zehnder interferometer configured to capture interferograms with a 0.02-fs temporal sampling accuracy through a well-stabilized 60-m unbalance arm length. A dual-servo mechanism is realized by combining a mechanical linear stage with an electro-optic modulator (EOM) within the fiber laser cavity, enabling stable sweeping control of the pulse repetition rate over a 1.0-MHz scan range with 0.4-Hz steps with reference to the Rb clock. Experimental results demonstrate that the P-branch lines of the H(13)CN reference cell can be observed with a signal-to-noise ratio reaching 350 for the most intense line.

6.
Opt Express ; 23(20): 25874-82, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26480101

RESUMO

Distances to multiple targets are measured simultaneously using a single femtosecond pulse laser split through a diffractive optical element. Pulse arrival from each target is detected by means of balanced cross-correlation of second harmonics generated using a PPKTP crystal. Time-of-flight of each returning pulse is counted by dual-comb interferometry with 0.01 ps timing resolution at a 2 kHz update rate. This multi-target ranging capability is demonstrated by performing multi-degree of freedom (m-DOF) sensing of a rigid-body motion simulating a satellite operating in orbit. This method is applicable to diverse terrestrial and space applications requiring concurrent multiple distance measurements with high precision.

7.
Opt Lett ; 39(10): 2831-4, 2014 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-24978214

RESUMO

We report a space radiation test performed on a semiconductor-type saturable absorber (SA) for its use in outer space as a key mode-locking component of fiber-based femtosecond pulse lasers. Gamma-ray effects on the nonlinear transmission behavior of the SA were evaluated by configuring a pump-probe experiment with femtosecond light pulses. Test results revealed that when the total ionizing dose of gamma-ray exposure reaches 120 krad, the SA encounters a sudden failure with its modulation depth and saturation fluence deteriorating from 11% to 6% and 40 to 110 µJ/cm2, respectively. On the other hand, no notable degradation was observed in its temporal response of absorption recovery.

8.
Opt Lett ; 39(10): 2986-9, 2014 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-24978254

RESUMO

Supercontinuum generation is performed using femtosecond laser pulses produced by combining two distinct mode-locking mechanisms of nonlinear polarization evolution with saturable absorption on an Er-doped fiber oscillator. The generated supercontinuum yields a high level of spectral visibility of 93%, without the presence of spontaneous emission of post-amplification, being well suited for precision spectroscopy, broadband interferometry, and coherent telecommunications.

9.
Sci Rep ; 4: 5134, 2014 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-24875665

RESUMO

We report a test operation of an Er-doped fibre femtosecond laser which was conducted for the first time in outer space. The fibre-based ultrashort pulse laser payload was designed to meet space-use requirements, undergone through ground qualification tests and finally launched into a low-earth orbit early in 2013. Test results obtained during a one-year mission lifetime confirmed stable mode-locking all the way through although the radiation induced attenuation (RIA) in the Er-doped gain fibre caused an 8.6% reduction in the output power. This successful test operation would help facilitate diverse scientific and technological applications of femtosecond lasers in space and earth atmosphere in the near future.