Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
2.
JAMA Netw Open ; 6(5): e2314428, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37227729

RESUMO

Importance: Platelet activation is a potential therapeutic target in patients with COVID-19. Objective: To evaluate the effect of P2Y12 inhibition among critically ill patients hospitalized for COVID-19. Design, Setting, and Participants: This international, open-label, adaptive platform, 1:1 randomized clinical trial included critically ill (requiring intensive care-level support) patients hospitalized with COVID-19. Patients were enrolled between February 26, 2021, through June 22, 2022. Enrollment was discontinued on June 22, 2022, by the trial leadership in coordination with the study sponsor given a marked slowing of the enrollment rate of critically ill patients. Intervention: Participants were randomly assigned to receive a P2Y12 inhibitor or no P2Y12 inhibitor (usual care) for 14 days or until hospital discharge, whichever was sooner. Ticagrelor was the preferred P2Y12 inhibitor. Main Outcomes and Measures: The primary outcome was organ support-free days, evaluated on an ordinal scale that combined in-hospital death and, for participants who survived to hospital discharge, the number of days free of cardiovascular or respiratory organ support up to day 21 of the index hospitalization. The primary safety outcome was major bleeding, as defined by the International Society on Thrombosis and Hemostasis. Results: At the time of trial termination, 949 participants (median [IQR] age, 56 [46-65] years; 603 male [63.5%]) had been randomly assigned, 479 to the P2Y12 inhibitor group and 470 to usual care. In the P2Y12 inhibitor group, ticagrelor was used in 372 participants (78.8%) and clopidogrel in 100 participants (21.2%). The estimated adjusted odds ratio (AOR) for the effect of P2Y12 inhibitor on organ support-free days was 1.07 (95% credible interval, 0.85-1.33). The posterior probability of superiority (defined as an OR > 1.0) was 72.9%. Overall, 354 participants (74.5%) in the P2Y12 inhibitor group and 339 participants (72.4%) in the usual care group survived to hospital discharge (median AOR, 1.15; 95% credible interval, 0.84-1.55; posterior probability of superiority, 80.8%). Major bleeding occurred in 13 participants (2.7%) in the P2Y12 inhibitor group and 13 (2.8%) in the usual care group. The estimated mortality rate at 90 days for the P2Y12 inhibitor group was 25.5% and for the usual care group was 27.0% (adjusted hazard ratio, 0.96; 95% CI, 0.76-1.23; P = .77). Conclusions and Relevance: In this randomized clinical trial of critically ill participants hospitalized for COVID-19, treatment with a P2Y12 inhibitor did not improve the number of days alive and free of cardiovascular or respiratory organ support. The use of the P2Y12 inhibitor did not increase major bleeding compared with usual care. These data do not support routine use of a P2Y12 inhibitor in critically ill patients hospitalized for COVID-19. Trial Registration: ClinicalTrials.gov Identifier: NCT04505774.


Assuntos
COVID-19 , Agonistas do Receptor Purinérgico P2Y , Humanos , Masculino , Pessoa de Meia-Idade , Estado Terminal/terapia , Hemorragia , Mortalidade Hospitalar , Ticagrelor/uso terapêutico , Agonistas do Receptor Purinérgico P2Y/uso terapêutico
3.
Circ Cardiovasc Interv ; 16(5): e012655, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37192308

RESUMO

BACKGROUND: The LRT trial (Low-Risk Transcatheter Aortic Valve Replacement [TAVR]) demonstrated the safety and feasibility of TAVR in low-risk patients, with excellent 1- and 2-year outcomes. The objective of the current study is to provide the overall clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration at 4 years. METHODS: The prospective, multicenter LRT trial was the first Food and Drug Administration-approved investigational device exemption study to evaluate feasibility and safety of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis. Clinical outcomes and valve hemodynamics were documented annually through 4 years. RESULTS: A total of 200 patients were enrolled, and follow-up was available on 177 patients at 4 years. The rates of all-cause mortality and cardiovascular death were 11.9% and 3.3%, respectively. The stroke rate rose from 0.5% at 30 days to 7.5% at 4 years, and permanent pacemaker implantation rose from 6.5% at 30 days to 11.7% at 4 years. Endocarditis was detected in 2.5% of the cohort, with no new cases reported between 2 and 4 years. Transcatheter heart valve hemodynamics remained excellent post-procedure and were maintained (mean gradient 12.56±5.54 mm Hg and aortic valve area 1.69±0.52 cm2) at 4 years. At 30 days, HALT was observed in 14% of subjects who received a balloon-expandable transcatheter heart valve. There was no difference in valve hemodynamics between patients with and without HALT (mean gradient 14.94±5.01 mm Hg versus 12.3±5.57 mm Hg; P=0.23) at 4 years. The overall rate of structural valve deterioration was 5.8%, and there was no impact of HALT on valve hemodynamics, endocarditis, or stroke at 4 years. CONCLUSIONS: TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis was found to be safe and durable at 4 years. Structural valve deterioration rates were low irrespective of the type of valve, and the presence of HALT at 30 days did not affect structural valve deterioration, transcatheter valve hemodynamics, and stroke rate at 4 years. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02628899.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Prospectivos , Fatores de Risco , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Hemodinâmica , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Trombose/etiologia
4.
Int J Cardiol ; 371: 305-311, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36272571

RESUMO

BACKGROUND: Subclinical leaflet thrombosis (SLT) is characterized on computed tomography (CT) imaging as hypoattenuated leaflet thickening (HALT), reduced leaflet motion (RELM), and hypoattenuation affecting motion (HAM). How antithrombotic regimen type impacts SLT remains poorly understood. We evaluated how antithrombotic regimen type impacts SLT in low-risk subjects following transcatheter aortic valve implantation (TAVI). METHODS: This substudy is a post hoc analysis of the LRT 1.0 and 2.0 trials to assess SLT in subjects who underwent CT or transoesophageal echocardiogram (TOE) imaging at 30 days, stratified by antithrombotic regimen received (single antiplatelet therapy [SAPT], dual antiplatelet therapy [DAPT], or oral anticoagulation). We also utilized univariable logistic regression modelling to identify echocardiographic predictors of HALT. RESULTS: Rates of HALT, RELM, and HAM were all significantly lower with oral anticoagulation compared to SAPT or DAPT at 30 days (HALT: 2.6% vs 14.3% vs 17.2%, respectively, with p < 0.001; RELM: 1.8% vs 9.6% vs 13.1%, respectively, with p = 0.004; and HAM: 0.9% vs 8.5% vs 9.8%, respectively, with p = 0.011). Additionally, short-term oral anticoagulation was not associated with higher bleeding rates compared to SAPT or DAPT (0.8% vs. 1.8% vs. 3.6%, p = 0.291). The presence of HALT did not significantly impact echocardiographic haemodynamic parameters at 30 days. CONCLUSION: This is the largest study to date that evaluated the impact of different antithrombotic regimens on SLT in low-risk TAVI patients. Oral anticoagulation was associated with significantly lower rates of SLT at 30 days compared to DAPT or SAPT, and there was no apparent benefit of DAPT over SAPT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Fibrinolíticos/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologia , Resultado do Tratamento , Inibidores da Agregação Plaquetária/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia
5.
EuroIntervention ; 18(5): e407-e416, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35321859

RESUMO

BACKGROUND: Given enough time, transcatheter heart valves (THVs) will degenerate and may require reintervention. Redo transcatheter aortic valve implantation (TAVI) is an attractive strategy but carries a risk of coronary obstruction. AIMS: We sought to predict how many TAVIs patients could undergo in their lifetime using computed tomography (CT) simulation. METHODS: We analysed paired CT scans (baseline and 30 days post-TAVI) from patients in the LRT trial and EPROMPT registry. We implanted virtual THVs on baseline CTs, comparing predicted valve-to-coronary (VTC) distances to 30-day CT VTC distances to evaluate the accuracy of CT simulation. We then simulated implantation of a second virtual THV within the first to estimate the risk of coronary obstruction due to sinus sequestration and the need for leaflet modification. RESULTS: We included 213 patients with evaluable paired CTs. There was good agreement between virtual (baseline) and actual (30 days) CT measurements. CT simulation of TAVI followed by redo TAVI predicted low coronary obstruction risk in 25.4% of patients and high risk, likely necessitating leaflet modification, in 27.7%, regardless of THV type. The remaining 46.9% could undergo redo TAVI so long as the first THV was balloon-expandable but would likely require leaflet modification if the first THV was self-expanding. CONCLUSIONS: Using cardiac CT simulation, it is possible to predict whether a patient can undergo multiple TAVI procedures in their lifetime. Those who cannot may prefer to undergo surgery first. CT simulation could provide a personalised lifetime management strategy for younger patients with symptomatic severe aortic stenosis and inform decision-making. CLINICALTRIALS: gov: NCT02628899; ClinicalTrials.gov: NCT03557242; ClinicalTrials.gov: NCT03423459.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Oclusão Coronária/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
Curr Rheumatol Rev ; 18(3): 18-25, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35220935

RESUMO

Fibromyalgia has previously been categorized as primary, secondary, and juvenile fibromyalgia. However, these definitions do not adequately explain the etiopathology of disease, nor do they help direct new specific therapies. Herein, we review the previously known categorizations of fibromyalgia. Based on common patient characteristics and previously studied pathophysiologies, we propose new subcategorizations of fibromyalgia that we have self-narrated, including hormonal fibromyalgia, neuroendocrine fibromyalgia, psychologic fibromyalgia, inflammatory fibromyalgia, and lastly, neuropathic fibromyalgia. Future research needs to be done to verify, add to, and fully describe these self-narrated categories of fibromyalgia that we have proposed.


Assuntos
Fibromialgia , Humanos
7.
Cardiovasc Revasc Med ; 33: 7-12, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34078581

RESUMO

BACKGROUND: Prospective bicuspid low-risk transcatheter aortic valve replacement (TAVR) registries' data demonstrated encouraging short-term results. Detailed data on transcatheter heart valve (THV) geometry after deployment using contemporary devices are lacking. This study sought to examine valve geometry after TAVR in patients with bicuspid aortic stenosis (AS). METHODS: The study population was patients from the LRT (Low Risk TAVR) trial who underwent TAVR using the SAPIEN 3 THV for bicuspid and tricuspid AS. THV geometry measured on 30-day computed tomography (CT) included valve height, angle, depth, and eccentricity. Additionally, THV hemodynamics and outcomes post-TAVR were compared among patients with bicuspid and tricuspid AS. RESULTS: A total of 107 patients from the LRT trial using the SAPIEN 3 THV were included in our analysis. On 30-day CT, the valve height ratio (1.07 vs. 1.07; p = 0.348), depths (right [5.6 mm vs. 6.2 mm; p = 0.223], left [5.3 mm vs. 4.4 mm; p = 0.082] and non [4.8 mm vs. 4.5 mm; p = 0.589] coronary cusps), eccentricities (1.08 vs. 1.07; p = 0.9550), and angles (except the right [3.9 degrees vs. 6.3 degrees; p = 0.003] and left [3.6 degrees vs. 6.0 degrees; p = 0.007]) were similar between bicuspid and tricuspid patients. Hemodynamics, stroke, and mortality were similar at 1 year. CONCLUSION: Despite challenging bicuspid anatomy of the aortic valve, our comprehensive CT analysis supports similar THV geometry between patients with bicuspid and tricuspid AS undergoing TAVR using the SAPIEN 3 THV in low-risk patients. This translated to excellent short-term clinical outcomes and THV hemodynamics in both aortic valve morphologies. TRIAL REGISTRY: NCT02628899, https://clinicaltrials.gov/ct2/show/NCT02628899.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Am Heart J ; 237: 25-33, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33713618

RESUMO

BACKGROUND: Previous studies from the Low Risk TAVR (LRT) trial demonstrated that transcatheter aortic valve replacement (TAVR) is safe and feasible in low-risk patients, with excellent 30-day and 1-year outcomes. The objective of this study was to report clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration (SVD) 2 years after TAVR. METHODS: The LRT trial was the first Food and Drug Administration-approved Investigational Device Exemption trial in the United States to evaluate the safety and feasibility of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis (AS). Valve hemodynamics and SVD by echo were recorded 30 days, 1 year, and 2 years post-TAVR. RESULTS: The LRT trial enrolled 200 low-risk patients to receive TAVR. Their mean age was 73.6 years and 61.5% were men. At 2-year follow-up, the mortality rate was 4.2%; the cardiovascular death rate was 1.6%. The disabling stroke rate was 1.1%, permanent pacemaker implantation rate was 8.6%, and 4 patients (2.2%) presented with endocarditis (2 between years 1 and 2). Of the 14% of TAVR subjects who had evidence of HALT at 30 days, there was no impact on valve hemodynamics, endocarditis or stroke at 2 years. CONCLUSIONS: TAVR for low-risk patients with symptomatic severe tricuspid AS is safe at 2 years. The presence of HALT at 30 days did not impact the early hemodynamic improvements nor the durability of the valve structure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Estudos de Viabilidade , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
9.
Circ Cardiovasc Interv ; 14(1): e009983, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33423540

RESUMO

BACKGROUND: The optimal antithrombotic regimen after transcatheter aortic valve replacement remains unclear. METHODS: In this randomized open-label study, low-risk patients undergoing transfemoral transcatheter aortic valve replacement at 7 centers in the United States were randomized 1:1 to low-dose aspirin or warfarin plus low-dose aspirin for 30 days. Patients who could not be randomized were enrolled in a separate registry. Computed tomography or transesophageal echocardiography was performed at 30 days. The primary effectiveness end point was a composite of the following at 30 days: hypoattenuated leaflet thickening, at least moderately reduced leaflet motion, hemodynamic dysfunction (mean aortic valve gradient ≥20 mm Hg, effective orifice area ≤1.0 cm2, dimensionless valve index <0.35, or moderate or severe aortic regurgitation), stroke, or transient ischemic attack. RESULTS: Between July 2018 and October 2019, 94 patients were randomly assigned, 50 to aspirin and 44 to warfarin plus aspirin, and 30 were enrolled into the registry. In the intention-to-treat analysis of the randomized cohort, the composite primary effectiveness end point was met in 26.5% for aspirin versus 7.0% for warfarin plus aspirin (P=0.014; odds ratio, 4.8 [95% CI, 1.3-18.3]). The rate of hypoattenuated leaflet thickening was 16.3% for aspirin versus 4.7% for warfarin plus aspirin (P=0.07; odds ratio, 4.0 [95% CI, 0.8-20.0]). There was no excess bleeding at 30 days with anticoagulation. In the as-treated analysis of pooled randomized and registry cohorts, the rate of hypoattenuated leaflet thickening was 16.7% for aspirin versus 3.1% for warfarin plus aspirin (P=0.011; odds ratio, 6.3 [95% CI, 1.3-30.6]). CONCLUSIONS: In low-risk transcatheter aortic valve replacement patients, anticoagulation with warfarin may prevent transcatheter heart valve dysfunction in the short term without excess bleeding. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03557242.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Aspirina/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos , Varfarina/efeitos adversos
10.
Cardiovasc Revasc Med ; 27: 1-6, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33129688

RESUMO

BACKGROUND/PURPOSE: This sub-analysis of the prospective Low Risk TAVR (LRT) trial determined anatomical characteristics associated with hypoattenuated leaflet thickening (HALT), which may contribute to early transcatheter heart valve (THV) degeneration. METHODS/MATERIALS: The LRT trial enrolled 200 low-risk patients between February 2016 and February 2018. All subjects underwent baseline and 30-day CT studies, analyzed by an independent core laboratory. Additional measurements, namely THV expansion, eccentricity, depth, and commissural alignment, were made by consensus of three independent readers. HALT was observed only in the Sapien 3 THV, so Evolut valves were excluded from this analysis. RESULTS: In the LRT trial, 177 subjects received Sapien 3 THVs, of whom 167 (94.3%) had interpretable 30-day CTs and were eligible for this analysis. Twenty-six subjects had HALT (15.6%). Baseline characteristics were similar between groups. There was no difference in THV size implanted and baseline aortic-root geometry between groups. In patients who developed HALT, THV implantation depth was shallower than in patients who did not develop HALT (2.6 ± 1.1 mm HALT versus 3.3 ± 1.8 mm no-HALT, p = 0.03). There were more patients in the HALT group with commissural malalignment (40% vs. 28%; p = 0.25), but this did not reach statistical significance. In a univariable regression model, no predetermined variables were shown to independently predict the development of HALT. CONCLUSIONS: This study did not find anatomical or THV implantation characteristics that predicted the development of HALT at 30 days. This study cannot exclude subtle effects or interaction between factors because of the small number of events.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
JACC Cardiovasc Interv ; 13(9): 1019-1027, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32381181

RESUMO

OBJECTIVES: The aim of this study was to evaluate clinical outcomes and transcatheter heart valve hemodynamic parameters after transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic stenosis (AS). BACKGROUND: TAVR is approved for low-risk patients in the United States. However, patients with bicuspid AS were excluded from the randomized cohorts of the pivotal low-risk trials. METHODS: The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and was the first and only U.S. Food and Drug Administration-approved investigational device exemption trial to evaluate the feasibility of TAVR with either balloon-expandable or self-expanding valves in low-risk patients with bicuspid AS. The primary endpoint was all-cause mortality at 30 days. Baseline and follow-up echocardiography and computed tomography to detect leaflet thickening were analyzed in an independent core laboratory. RESULTS: Sixty-one low-risk patients with symptomatic, severe AS and bicuspid aortic valves (78.3% Sievers type 1 morphology) underwent TAVR at 6 centers from 2016 to 2019. The mean age was 68.6 years, and 42.6% were men. At 30 days, there was zero mortality and no disabling strokes. The rate of new permanent pacemaker implantation was 13.1%; just 1 patient had a moderate paravalvular leak at 30 days. Hypoattenuated leaflet thickening was observed in 10% of patients at 30 days. CONCLUSIONS: TAVR appears to be safe in patients with bicuspid AS, with short length of hospital stay, zero mortality, and no disabling strokes at 30 days. Subclinical leaflet thrombosis was observed in a minority of patients at 30 days but did not appear to be associated with clinical events.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
12.
JACC Cardiovasc Interv ; 13(6): 726-735, 2020 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-32192693

RESUMO

OBJECTIVES: The aim of this study was to evaluate the feasibility of coronary access and aortic valve reintervention in low-risk patients undergoing transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter heart valve (THV). BACKGROUND: Younger, low-risk TAVR patients are more likely than older, higher risk patients to require coronary angiography, percutaneous coronary intervention, or aortic valve reintervention, but their THVs may impede coronary access and cause coronary obstruction during TAVR-in-TAVR. METHODS: The LRT (Low Risk TAVR) trial (NCT02628899) enrolled 200 subjects with symptomatic severe aortic stenosis to undergo TAVR using commercially available THVs. Subjects who received balloon-expandable THVs and who had 30-day cardiac computed tomographic scans were included in this study. In a subgroup, the feasibility of intentional THV crimping on the delivery catheter to pre-determine commissural alignment was tested. RESULTS: In the LRT trial, 168 subjects received balloon-expandable THVs and had 30-day cardiac computed tomographic scans, of which 137 were of adequate image quality for analysis. The most challenging anatomy for coronary access (THV frame above and commissural suture post in front of a coronary ostium) was observed in 9% to 13% of subjects. Intentional THV crimping did not appear to meaningfully affect commissural alignment. The THV frame extended above the sinotubular junction in 21% of subjects, and in 13%, the distance between the THV and the sinotubular junction was <2 mm, signifying that TAVR-in-TAVR may not be feasible without causing coronary obstruction. CONCLUSIONS: TAVR may present challenges to future coronary access and aortic valve reintervention in a substantial number of low-risk patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco , Estenose Coronária/etiologia , Vasos Coronários , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Retratamento , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos
13.
Am J Cardiol ; 125(8): 1216-1221, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32087995

RESUMO

We aimed to evaluate the burden of coronary artery disease (CAD) using the computed tomography (CT) Leaman score in low-risk transcatheter aortic valve implantation (TAVI) patients. The extent of CAD in low-risk patients with aortic stenosis who are candidates for TAVI has not been accurately quantified. The CT Leaman score was developed to quantify coronary CT angiography (CCTA) atherosclerotic burden and has been validated to evaluate the extent of CAD. CT Leaman score >5 has been associated with an increase in major adverse cardiac events over long-term follow-up. The study population included patients enrolled in the Low Risk TAVI trial who underwent CCTA before the procedure. For the CT Leaman score, we used 3 sets of weighting factors: (1) location of coronary plaques, (2) type of plaque, and (3) degree of stenosis. A total of 200 patients were enrolled in the Low Risk TAVI trial. Excluded were 31 patients who had no analyzable CCTA imaging. For the remaining 169 patients, the mean CT Leaman score was 6.27 ± 0.27, of whom 102 (60.4%) had CT Leaman score >5. Nearly all analyzed patients (97%) had coronary plaques. Furthermore, 33 patients (19.5%) had potentially obstructive coronary plaques (>50% stenosis by CCTA) in proximal segments. Most low-risk TAVI patients have significant CAD burden by CCTA. It should be a priority for future TAVI devices to guarantee unimpeded access to the coronary arteries for selective angiography and interventions.


Assuntos
Estenose da Valva Aórtica/epidemiologia , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/epidemiologia , Placa Aterosclerótica/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Estenose da Valva Aórtica/cirurgia , Comorbidade , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Placa Aterosclerótica/diagnóstico por imagem , Cuidados Pré-Operatórios , Prevalência , Ajuste de Prótese , Medição de Risco , Tomografia Computadorizada por Raios X
14.
Circ Cardiovasc Imaging ; 12(12): e009608, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31826675

RESUMO

BACKGROUND: This analysis evaluated echocardiographic predictors of hypoattenuated leaflet thickening (HALT) in low-risk patients undergoing transcatheter aortic valve replacement and assessed 1-year clinical and hemodynamic consequences. HALT by computed tomography may be associated with early valve degeneration and increased neurological events. METHODS: Echocardiograms were performed at baseline, discharge, 30 days, and 1 year post-procedure. Four-dimensional contrast-enhanced computed tomography assessed HALT at 30 days. Independent core laboratories analyzed images. Doppler hemodynamic parameters were tested in a univariable regression model to identify HALT predictors. One-year clinical and hemodynamic outcomes were compared between HALT (+) and (-) patients. RESULTS: Analysis included 170 patients with Sapien 3 valves and diagnostic 30-day computed tomographies, of whom 27 (16%) had HALT. Baseline characteristics were similar between groups. After transcatheter aortic valve replacement, aortic flow was nonsignificantly reduced in patients who developed HALT. Regression analysis did not show significant association between baseline or discharge valve hemodynamics and development of HALT at 30 days. Patients with HALT had smaller aortic valve areas (1.4±0.4 versus 1.7±0.5 cm2; P=0.018) and Doppler velocity index (0.4±0.1 versus 0.5±0.1; P=0.003) than those without HALT at 30 days but not at 1 year. There was no difference in aortic mean gradient at 30 days. There was no difference between the groups in New York Heart Association class, 6-minute walk distance, and mortality at 1 year. CONCLUSIONS: There were no early hemodynamic predictors of HALT. At 30 days, patients with HALT had worse valve hemodynamics than those without HALT, but hemodynamic and clinical outcomes at 1 year were similar. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02628899.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Falha de Prótese , Medição de Risco , Fatores de Risco , Trombose/diagnóstico por imagem , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
15.
JACC Cardiovasc Interv ; 12(10): 901-907, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-30860059

RESUMO

OBJECTIVES: This study sought to evaluate clinical outcomes and transcatheter heart valve hemodynamics at 1 year after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: Early results from the LRT (Low Risk TAVR) trial demonstrated that TAVR is safe in patients with symptomatic severe aortic stenosis who are at low risk for surgical valve replacement. METHODS: The LRT trial was an investigator-initiated, prospective, multicenter study and was the first Food and Drug Administration-approved Investigational Device Exemption trial to evaluate feasibility of TAVR in low-risk patients. The primary endpoint was all-cause mortality at 30 days. Secondary endpoints included clinical outcomes and valve hemodynamics at 1 year. RESULTS: The LRT trial enrolled 200 low-risk patients with symptomatic severe AS to undergo TAVR at 11 centers. Mean age was 73.6 years and 61.5% were men. At 30 days, there was zero mortality, zero disabling stroke, and low permanent pacemaker implantation rate (5.0%). At 1-year follow-up, mortality was 3.0%, stroke rate was 2.1%, and permanent pacemaker implantation rate was 7.3%. Two (1.0%) subjects underwent surgical reintervention for endocarditis. Of the 14% of TAVR subjects who had evidence of hypoattenuated leaflet thickening at 30 days, there was no impact on valve hemodynamics at 1 year, but the stroke rate was numerically higher (3.8% vs. 1.9%; p = 0.53). CONCLUSIONS: TAVR in low-risk patients with symptomatic severe aortic stenosis appears to be safe at 1 year. Hypoattenuated leaflet thickening, observed in a minority of TAVR patients at 30 days, did not have an impact on valve hemodynamics in the longer term.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Índices de Gravidade do Trauma , Resultado do Tratamento , Estados Unidos
16.
J Am Coll Cardiol ; 72(18): 2095-2105, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30170075

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is now the standard of care for patients with symptomatic severe aortic stenosis who are extreme, high, or intermediate risk for surgical aortic valve replacement (SAVR). OBJECTIVES: The authors sought to evaluate TAVR in a prospective multicenter trial involving low-risk patients. METHODS: The Low Risk TAVR (Feasibility of Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic, Severe Aortic Stenosis) trial was the first U.S. Food and Drug Administration-approved Investigational Device Exemption trial to enroll in the United States. This investigator-led trial was a prospective, multicenter, unblinded, comparison to historical controls from the Society of Thoracic Surgeons (STS) database. The primary endpoint was all-cause mortality at 30 days. RESULTS: The authors enrolled 200 low-risk patients with symptomatic severe aortic stenosis at 11 centers to undergo TAVR. The authors compared outcomes with an inverse probability weighting-adjusted control cohort of 719 patients who underwent SAVR at the same institutions using the STS database. At 30 days, there was zero all-cause mortality in the TAVR group versus 1.7% mortality in the SAVR group. There was zero in-hospital stroke rate in the TAVR group versus 0.6% stroke in the SAVR group. Permanent pacemaker implantation rates were similar between TAVR and SAVR (5.0% vs. 4.5%). The rates of new-onset atrial fibrillation (3.0%) and length of stay (2.0 ± 1.1 days) were low in the TAVR group. One patient (0.5%) in the TAVR group had >mild paravalvular leak at 30 days. Fourteen percent of TAVR patients had evidence of subclinical leaflet thrombosis at 30 days. CONCLUSIONS: TAVR is safe in low-risk patients with symptomatic severe aortic stenosis, with low procedural complication rates, short hospital length of stay, zero mortality, and zero disabling stroke at 30 days. Subclinical leaflet thrombosis was observed in a minority of TAVR patients at 30 days. (Feasibility of Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic, Severe Aortic Stenosis [Low Risk TAVR; NCT02628899).


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
18.
Cardiovasc Revasc Med ; 13(4): 215-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22818532

RESUMO

BACKGROUND: Several patients undergoing permanent pacemaker (PPM) implantation/upgrade present with difficult access due to sub- or total central vein occlusion. Our institution has used the endovascular approach to recanalize central veins to allow for subsequent PPM implantation. Here we aim to describe the feasibility and safety of using this approach to allow for PPM implantation/upgrade. METHODS: From October 2006 to November 2010, 50 consecutive patients who underwent central vein recanalization prior to PPM implantation were included in this analysis. RESULTS: The population's mean age was 70 years, with a high rate of comorbidities including chronic renal failure (52.0%), congestive heart failure (64.0%), diabetes (33.3%) and peripheral vascular disease (36.0%). The endovascular recanalization procedure was performed via femoral access in all patients; however adjuvant brachial access was required in 13 cases and subclavian vein in one. Subclavian vein (74.5%) followed by innominate vein (21.6%) were the most common locations/target for recanalization. Successful vein recanalization followed by successful PPM implantation/upgrade was achieved in 48 patients (96.0%) without peri-procedural complications. Two patients died during the hospitalization, one due to severe respiratory failure and a second due to complicated end-stage renal disease, although neither was related to the endovascular procedure. No other event, including myocardial infarction, cerebral-vascular accident, bleeding/transfusion, or renal failure was identified. CONCLUSIONS: This study proved the feasibility and safety of the endovascular approach to recanalize central veins in patients with poor vascular access to allow for further PPM implantation/upgrade.


Assuntos
Cateterismo Venoso Central , Procedimentos Endovasculares , Marca-Passo Artificial , Doenças Vasculares/terapia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/mortalidade , Comorbidade , Constrição Patológica , District of Columbia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/mortalidade , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Veia Femoral/diagnóstico por imagem , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Flebografia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/mortalidade
19.
J Interv Cardiol ; 24(3): 278-84, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21535150

RESUMO

OBJECTIVES: This study aimed to evaluate the safety of low-dose protamine administration to facilitate earlier vascular sheath removal. BACKGROUND: Vascular access complications are the most common cause of postprocedural morbidity in patients undergoing peripheral endovascular intervention (PEI). Prolonged manual compression and closure devices do not eliminate these complications. METHODS: A consecutive series of 166 patients who underwent PEI were retrospectively compared to an all-comers control group of 136 patients who did not receive protamine. The study population received an intravenous dose of protamine based upon the dose of heparin received and the length of the procedure. The arterial sheath was removed when activated clotting time was less than 220 seconds. Primary end-points included bleeding complications, comprised of groin hematomas and retroperitoneal bleeding, and vascular complications, comprised of pseudoaneurysms, access vessel thrombosis, and arteriovenous fistula formation. RESULTS: The study population on average was older than the control group (71 vs. 67 years) and had a higher incidence of hypercholesterolemia (89.8% vs. 76.5%, P = 0.002). The average dose of protamine was 1.9 ± 0.83 mg, with a total dose of heparin of 5371 ± 1327 units. The time until sheath removal was 8.9 ± 8.6 minutes in the protamine group versus 188 ± 118 minutes in the control group (P < 0.001). There were no episodes of protamine anaphylaxis or adverse reactions. The access site complication rate between the 2 groups was statistically insignificant. CONCLUSIONS: This strategy offers an inexpensive, safe, and reliable method to achieve hemostasis and facilitate earlier sheath removal in patients undergoing PEI.


Assuntos
Procedimentos Endovasculares , Artéria Femoral/cirurgia , Antagonistas de Heparina/administração & dosagem , Doença Arterial Periférica/cirurgia , Protaminas/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos de Coortes , Terapia Combinada , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
20.
J Interv Cardiol ; 24(2): 112-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21457325

RESUMO

BACKGROUND: Prehospital 12-lead electrocardiogram (ECG) reduces the time to reperfusion in acute ST-segment elevation myocardial infarction (STEMI). However, the reliability of using cellular video-phone (VP) assisted interpretation of ECG is unknown. METHODS: We studied the interphysician reliability in interpreting the ECG assisted with VP compared to print ECG interpretation. Twenty-seven physicians prospectively interpreted the ECG transmitted from the field in real-time using VP and later using the same printed ECG. The time to completion, accuracy of interpretation, and physician rating of the VP technology were recorded. RESULTS: Similar high interphysician reliability was observed with both VP assisted and printed ECG interpretation including presence of ST-segment elevation (intraclass correlation coefficient [ICC]= 0.98 [95% CI 0.96-1] vs. 0.99 [95% CI 0.99-1]) and pathologic Q wave (ICC = 0.99 [95% CI 0.98-1] vs. 1 [95% CI 1]), respectively. The mean time to transmit and interpret the ECG with VP versus printed ECG was 3.9 ± 1.9 versus 2.1 ± 0.9 minutes, respectively, P < 0.01. On a scale of 1 to 5 with 5 being the best, the average rating of VP ease of use was 4.4 ± 0.5 and utility to recommend treatment was rated a 5. CONCLUSION: Cellular VP-assisted transmission and interpretation in real-time of prehospital ECG has high interphysician reliability, similar to the printed ECG interpretation. Future studies testing whether VP decreases the ischemic time and expedites the reperfusion of STEMI patients are needed.


Assuntos
Telefone Celular/instrumentação , Eletrocardiografia/métodos , Serviços Médicos de Emergência/métodos , Infarto do Miocárdio/diagnóstico , Telemedicina , Gravação em Vídeo/métodos , Humanos , Projetos Piloto , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...