Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Physiol Meas ; 45(5)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38729184

RESUMO

Objective. Pressure-volume loop analysis, traditionally performed by invasive pressure and volume measurements, is the optimal method for assessing ventricular function, while cardiac magnetic resonance (CMR) imaging is the gold standard for ventricular volume estimation. The aim of this study was to investigate the agreement between the assessment of end-systolic elastance (Ees) assessed with combined CMR and simultaneous pressure catheter measurements compared with admittance catheters in a porcine model.Approach. Seven healthy pigs underwent admittance-based pressure-volume loop evaluation followed by a second assessment with CMR during simultaneous pressure measurements.Main results. Admittance overestimated end-diastolic volume for both the left ventricle (LV) and the right ventricle (RV) compared with CMR. Further, there was an underestimation of RV end-systolic volume with admittance. For the RV, however, Ees was systematically higher when assessed with CMR plus simultaneous pressure measurements compared with admittance whereas there was no systematic difference in Ees but large differences between admittance and CMR-based methods for the LV.Significance. LV and RV Ees can be obtained from both admittance and CMR based techniques. There were discrepancies in volume estimates between admittance and CMR based methods, especially for the RV. RV Ees was higher when estimated by CMR with simultaneous pressure measurements compared with admittance.


Assuntos
Imageamento por Ressonância Magnética , Animais , Suínos , Pressão Sanguínea/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Modelos Animais
2.
Am J Emerg Med ; 73: 145-153, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37659143

RESUMO

PURPOSE: To evaluate the effect of methylene blue administered as a bolus on return of spontaneous circulation (ROSC), lactate levels, vasopressor requirements, and markers of neurological injury in a clinically relevant pig model of cardiac arrest. MATERIALS AND METHODS: 40 anesthetized pigs were subjected to acute myocardial infarction and 7 min of untreated cardiac arrest. Animals were randomized into three groups: one group received saline only (controls), one group received 2 mg/kg methylene blue and saline (MB + saline), and one group received two doses of 2 mg/kg methylene blue (MB + MB). The first intervention was given after the 3rd rhythm analysis, while the second dose was administered one hour after achieving ROSC. Animals underwent intensive care and observation for six hours, followed by cerebral magnetic resonance imaging (MRI). The primary outcome for this study was development in lactate levels after cardiac arrest. Categorical data were compared using Fisher's exact test and pointwise data were analyzed using one-way analysis of variance (ANOVA) or equivalent non-parametric test. Continuous data collected over time were analyzed using a linear mixed effects model. A value of p < .05 was considered statistically significant. RESULTS: Lactate levels increased in all groups after cardiac arrest and resuscitation, however lactate levels in the MB + MB group decreased significantly faster compared with the control group (p = .007) and the MB + saline group (p = .02). The proportion of animals achieving initial ROSC was similar across groups: 11/13 (85%) in the control group, 10/13 (77%) in the MB + saline group, and 12/14 (86%) in the MB + MB group (p = .81). Time to ROSC did not differ between groups (p = .67). There was no significant difference in accumulated norepinephrine dose between groups (p = .15). Cerebral glycerol levels were significantly lower in the MB + MB group after resuscitation compared with control group (p = .03). However, MRI data revealed no difference in apparent diffusion coefficient, cerebral blood flow, or dynamic contrast enhanced MR perfusion between groups. CONCLUSION: Treatment with a bolus of methylene blue during cardiac arrest and after resuscitation did not significantly improve hemodynamic function. A bolus of methylene blue did not yield the neuroprotective effects that have previously been described in animals receiving methylene blue as an infusion.

3.
Magn Reson Med ; 90(2): 655-663, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36971340

RESUMO

PURPOSE: Ischemic injury in the kidney is a common pathophysiological event associated with both acute kidney injury and chronic kidney disease; however, regional ischemia-reperfusion as seen in thromboembolic renal disease is often undetectable and thus subclinical. Here, we assessed the metabolic alterations following subclinical focal ischemia-reperfusion injury with hyperpolarized [1-13 C]pyruvate MRI in a porcine model. METHODS: Five pigs were subjected to 60 min of focal kidney ischemia. After 90 min of reperfusion, a multiparametric proton MRI protocol was performed on a clinical 3T scanner system. Metabolism was evaluated using 13 C MRI following infusion of hyperpolarized [1-13 C]pyruvate. Ratios of pyruvate to its detectable metabolites (lactate, bicarbonate, and alanine) were used to quantify metabolism. RESULTS: The focal ischemia-reperfusion injury resulted in injured areas with a mean size of 0.971 cm3 (±1.019). Compared with the contralateral kidney, the injured areas demonstrated restricted diffusion (1269 ± 83.59 × 10-6 mm2 /s vs. 1530 ± 52.73 × 10-6 mm2 /s; p = 0.006) and decreased perfusion (158.8 ± 29.4 mL/100 mL/min vs. 274 ± 63.1 mL/100 mL/min; p = 0.014). In the metabolic assessment, the injured areas displayed increased lactate/pyruvate ratios compared with the entire ipsilateral and the contralateral kidney (0.35 ± 0.13 vs. 0.27 ± 0.1 vs. 0.25 ± 0.1; p = 0.0086). Alanine/pyruvate ratio was unaltered, and we were unable to quantify bicarbonate due to low signal. CONCLUSION: MRI with hyperpolarized [1-13 C]pyruvate in a clinical setup is capable of detecting the acute, subtle, focal metabolic changes following ischemia. This may prove to be a valuable future addition to the renal MRI suite.


Assuntos
Ácido Pirúvico , Traumatismo por Reperfusão , Animais , Suínos , Ácido Pirúvico/metabolismo , Bicarbonatos/metabolismo , Rim/diagnóstico por imagem , Rim/metabolismo , Imageamento por Ressonância Magnética/métodos , Traumatismo por Reperfusão/diagnóstico por imagem , Ácido Láctico/metabolismo , Alanina/metabolismo
4.
PLoS One ; 18(2): e0281676, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36795705

RESUMO

INTRODUCTION: Intrarenal backflow (IRB) is known to occur at increased intrarenal pressure (IRP). Irrigation during ureteroscopy increases IRP. Complications such as sepsis is more frequent after prolonged high-pressure ureteroscopy. We evaluated a new method to document and visualize intrarenal backflow as a function of IRP and time in a pig model. METHODS: Studies were performed on five female pigs. A ureteral catheter was placed in the renal pelvis and connected to a Gadolinium/ saline solution 3 ml/L for irrigation. An occlusion balloon-catheter was left inflated at the uretero-pelvic junction and connected to a pressure monitor. Irrigation was successively regulated to maintain steady IRP levels at 10, 20, 30, 40 and 50 mmHg. MRI of the kidneys was performed at 5-minute intervals. PCR and immunoassay analyses were executed on the harvested kidneys to detect potential changes in inflammatory markers. RESULTS: MRI showed backflow of Gadolinium into the kidney cortex in all cases. The mean time to first visual damage was 15 minutes and the mean registered pressure at first visual damage was 21 mmHg. On the final MRI the mean percentage of IRB affected kidney was 66% after irrigation with a mean maximum pressure of 43 mmHg for a mean duration of 70 minutes. Immunoassay analyses showed increased MCP-1 mRNA expression in the treated kidneys compared to contralateral control kidneys. CONCLUSIONS: Gadolinium enhanced MRI provided detailed information about IRB that has not previously been documented. IRB occurs at even very low pressures, and these findings are in conflict with the general consensus that keeping IRP below 30-35 mmHg eliminates the risk of post-operative infection and sepsis. Moreover, the level of IRB was documented to be a function of both IRP and time. The results of this study emphasize the importance of keeping IRP and OR time low during ureteroscopy.


Assuntos
Gadolínio , Sepse , Feminino , Animais , Suínos , Gadolínio/farmacologia , Pressão , Rim/diagnóstico por imagem , Pelve Renal , Ureteroscopia/métodos
5.
Magn Reson Med ; 89(3): 1265-1277, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36321576

RESUMO

PURPOSE: This article presents a novel 14-channel receive-only array for 13 C human head imaging at 3 T that explores the SNR gain by operating at cryogenic temperature cooled by liquid nitrogen. METHODS: Cryostats are developed to evaluate single-coil bench SNR performance and cool the 14-channel array with liquid nitrogen while having enough thermal insulation between the coils and the sample. The temperature distribution for the coil array is measured. Circuits are adapted to the -189°C environment and implemented in the 14-channel array. 13 C images are acquired with the array at cryogenic and room temperature in a 3T scanner. RESULTS: Compared with room temperature, the array at cryogenic temperature provides 27%-168% SNR improvement over all voxels and 47% SNR improvement near the image center. The measurements show a decrease of the element noise correlation at cryogenic temperature. CONCLUSION: It is demonstrated that higher SNR can be achieved by cryogenically cooling the 14-channel array. A cryogenic array suitable for clinical imaging can be further developed on the array proposed. The cryogenic coil array is most likely suited for scenarios in which high SNR deep in a head and decent SNR on the periphery are required.


Assuntos
Temperatura Baixa , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Nitrogênio , Imagens de Fantasmas , Razão Sinal-Ruído , Desenho de Equipamento
6.
Front Cardiovasc Med ; 9: 871603, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35647079

RESUMO

Aims: Persistent cardiac symptoms are an increasingly reported phenomenon following COVID-19. However, the underlying cause of cardiac symptoms is unknown. This study aimed to identify the underlying causes, if any, of these symptoms 1 year following acute COVID-19 infection. Methods and Results: 22 individuals with persistent cardiac symptoms were prospectively investigated using echocardiography, cardiovascular magnetic resonance (CMR), 6-min walking test, cardio-pulmonary exercise testing and electrocardiography. A median of 382 days (IQR 368, 442) passed between diagnosis of COVID-19 and investigation. As a cohort their echocardiography, CMR, 6-min walking test and exercise testing results were within the normal ranges. There were no differences in left ventricular ejection fraction (61.45 ± 6.59 %), global longitudinal strain (19.80 ± 3.12 %) or tricuspid annular plane systolic excursion (24.96 ± 5.55 mm) as measured by echocardiography compared to a healthy control group. VO2 max (2045.00 ± 658.40 ml/min), % expected VO2 max (114.80 ± 23.08 %) and 6-minute distance walked (608.90 ± 54.51 m) exceeded that expected for the patient cohort, whilst Troponin I (5.59 ± 6.59 ng/l) and Nt-proBNP (88.18 ± 54.27 ng/l) were normal. Conclusion: Among a cohort of 22 patients with self-reported persistent cardiac symptoms, we identified no underlying cardiac disease or reduced cardiopulmonary fitness 1 year following COVID-19.

7.
NMR Biomed ; 35(6): e4678, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34961990

RESUMO

Personalized medicine or individualized therapy promises a paradigm shift in healthcare. This is particularly true in complex and multifactorial diseases such as diabetes and the multitude of related pathophysiological complications. Diabetic cardiomyopathy represents an emerging condition that could be effectively treated if better diagnostic and, in particular, better therapeutic monitoring tools were available. In this study, we investigate the ability to differentiate low and high doses of metabolically targeted therapy in an obese type 2 diabetic rat model. Low-dose dichloroacetate (DCA) treatment was associated with increased lactate production, while no or little change was seen in bicarbonate production. High-dose DCA treatment was associated with a significant metabolic switch towards increased bicarbonate production. These findings support further studies using hyperpolarized [1-13 C]-pyruvate magnetic resonance imaging to differentiate treatment effects and thus allow for personalized titration of therapeutics.


Assuntos
Diabetes Mellitus Tipo 2 , Ácido Pirúvico , Acetatos , Animais , Bicarbonatos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Ácido Dicloroacético/farmacologia , Ácido Dicloroacético/uso terapêutico , Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento por Ressonância Magnética/métodos , Ácido Pirúvico/metabolismo , Ratos
8.
Magn Reson Med ; 87(2): 896-903, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34554602

RESUMO

PURPOSE: The number of glomeruli is different in men and women, as they also present different prevalence and progression of chronic kidney disease. A recent study has demonstrated a potential difference in renal metabolism between sexes, and a potential explanation could be the differences in glomeruli number. This study investigates the potential correlation between glomerular number and pyruvate metabolism in healthy kidneys. METHODS: This study is an experimental study with rats (N = 12). We used cationized-ferritin MRI to visualize and count glomeruli and hyperpolarized [1-13 C]pyruvate to map the metabolism. Dynamic contrast-enhanced MRI was used to analyze kidney hemodynamics using gadolinium tracer. RESULTS: Data showed no or subtle correlation between the number of glomeruli and the pyruvate metabolism. Minor differences were observed in the number of glomeruli (female = 24,509 vs. male = 26 350; p = .16), renal plasma flow (female = 606.6 vs. male= 455.7 ml/min/100 g; p = .18), and volume of distribution (female = 87.44 vs. male = 76.61 ml/100 ml; p = .54) between sexes. Mean transit time was significantly prolonged in males compared with females (female = 8.868 s vs. male = 10.63 s; p = .04). CONCLUSION: No strong statistically significant correlation between the number of glomeruli and the pyruvate metabolism was found in healthy rat kidneys.


Assuntos
Nefropatias , Glomérulos Renais , Animais , Feminino , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Ácido Pirúvico , Ratos
9.
Magn Reson Med ; 87(1): 57-69, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34378800

RESUMO

PURPOSE: Hyperpolarized [1-13 C]pyruvate MRS can measure cardiac metabolism in vivo. We investigated whether [1-13 C]pyruvate MRS could predict left ventricular remodeling following myocardial infarction (MI), long-term left ventricular effects of heart failure medication, and could identify responders to treatment. METHODS: Thirty-five rats were scanned with hyperpolarized [1-13 C]pyruvate MRS 3 days after MI or sham surgery. The animals were re-examined after 30 days of therapy with ß-blockers and ACE-inhibitors (active group, n = 12), placebo treatment (placebo group, n = 13) or no treatment (sham group, n = 10). Furthermore, heart tissue mitochondrial respiratory capacity was assessed by high-resolution respirometry. Metabolic results were compared between groups, over time and correlated to functional MR data at each time point. RESULTS: At 30 ± 0.5 days post MI, left ventricular ejection fraction (LVEF) differed between groups (sham, 77% ± 1%; placebo, 52% ± 3%; active, 63% ± 2%, P < .001). Cardiac metabolism, measured by both hyperpolarized [1-13 C]pyruvate MRS and respirometry, neither differed between groups nor between baseline and follow-up. Three days post MI, low bicarbonate + CO2 /pyruvate ratio was associated with low LVEF. At follow-up, in the active group, a poor recovery of LVEF was associated with high bicarbonate + CO2 /pyruvate ratio, as measured by hyperpolarized MRS. CONCLUSION: In a rat model of moderate heart failure, medical treatment improved function, but did not on average influence [1-13 C]pyruvate flux as measured by MRS; however, responders to heart failure medication had reduced capacity for carbohydrate metabolism.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Animais , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Espectroscopia de Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/tratamento farmacológico , Miocárdio , Ácido Pirúvico , Ratos , Volume Sistólico , Função Ventricular Esquerda
10.
Exp Physiol ; 106(12): 2412-2422, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34705304

RESUMO

NEW FINDINGS: What is the central question of this study? Is it possible to combine the hyperpolarized magnetic resonance technique and the hyperinsulinaemic clamp method in order to evaluate skeletal muscle metabolism in a large animal model? What is the main finding and its importance? The logistical set-up is possible, and we found substantial increments in glucose infusion rates representing skeletal muscle glucose uptake but no differences in ratios of [1-13 C]lactate to [1-13 C]pyruvate, [1-13 C]alanine to [1-13 C]pyruvate, and 13 C-bicarbonate to [1-13 C]pyruvate, implying that the hyperpolarization technique might not be optimal for detecting effects of insulin in skeletal muscle of anaesthetized animals, which is of significance for future studies. ABSTRACT: In skeletal muscle, glucose metabolism is tightly regulated by the reciprocal relationship between insulin and adrenaline, with pyruvate being at the intersection of both pathways. Hyperpolarized magnetic resonance (hMR) is a new approach to gain insights into these pathways, and human trials involving hMR and skeletal muscle metabolism are imminent. We aimed to combine the hyperinsulinaemic clamp technique and hMR in a large animal model resembling human physiology. Fifteen anaesthetized pigs were randomized to saline (control group), hyperinsulinaemic euglycaemic clamp technique (HE group) or hyperinsulinaemic hypoglycaemic clamp technique (HH group). Skeletal muscle metabolism was evaluated by hyperpolarized [1-13 C]pyruvate injection and hMR at baseline and after intervention. The glucose infusion rate per kilogram increased by a statistically significant amount in the HE and HH groups (P < 0.001). Hyperpolarized magnetic resonance showed no statistically significant changes in metabolite ratios: [1-13 C]lactate to [1-13 C]pyruvate in the HH group versus control group (P = 0.19); and 13 C-bicarbonate to [1-13 C]pyruvate ratio in the HE group versus the control group (P = 0.12). We found evidence of profound increments in glucose infusion rates representing skeletal muscle glucose uptake, but interestingly, no signs of significant changes in aerobic and anaerobic metabolism using hMR. These results imply that hyperpolarized [1-13 C]pyruvate might not be optimally suited to detect effects of insulin in anaesthetized resting skeletal muscle, which is of significance for future studies.


Assuntos
Hipoglicemiantes , Ácido Pirúvico , Animais , Técnica Clamp de Glucose , Hipoglicemiantes/metabolismo , Insulina/metabolismo , Modelos Animais , Músculo Esquelético/metabolismo , Ácido Pirúvico/metabolismo , Suínos
11.
NMR Biomed ; 34(11): e4583, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34240478

RESUMO

The purpose of the current study was to investigate if hyperpolarized [1-13 C]pyruvate can inform us on the metabolic consequences for the kidney glucose metabolism upon treatment with the pyruvate kinase M2 (PKM2) activator TEPP-46, which has shown promise as a novel therapeutic target for diabetic nephropathy. A healthy male Wistar rat model was employed to study the conversion of [1-13 C]pyruvate to [1-13 C]lactate in the kidney 2 and 4 h after treatment with TEPP-46. All rats were scanned with hyperpolarized [1-13 C]pyruvate kidney MR and vital parameters and blood samples were taken after scanning. The PKM2 activator TEPP-46 increases the glycolytic activity in the kidneys, leading to an increased lactate production, as seen by hyperpolarized pyruvate-to-lactate conversion. The results are supported by an increase in blood lactate, a decreased blood glucose level and an increased pyruvate kinase (PK) activity. The metabolic changes observed in both kidneys following treatment with TEPP-46 are largely independent of renal function and could as such represent a new and extremely sensitive metabolic readout for future drugs targeting PKM2. These results warrant further studies in disease models to evaluate if [1-13 C]pyruvate-to-[1-13 C]lactate conversion can predict treatment outcome.


Assuntos
Glucose/metabolismo , Rim/enzimologia , Piruvato Quinase/metabolismo , Ácido Pirúvico/metabolismo , Alanina/metabolismo , Animais , Bicarbonatos/metabolismo , Modelos Animais de Doenças , Ativação Enzimática , Glicólise , Hematócrito , Humanos , Concentração de Íons de Hidrogênio , Ácido Láctico/metabolismo , Masculino , Ratos Wistar
12.
Sci Rep ; 11(1): 4483, 2021 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-33627745

RESUMO

Mechanical unloading of the left ventricle reduces infarct size after acute myocardial infarction by reducing cardiac work. Left ventricular veno-occlusive unloading reduces cardiac work and may reduce ischemia and reperfusion injury. In a porcine model of myocardial ischemia-reperfusion injury we randomized 18 pigs to either control or veno-occlusive unloading using a balloon engaged from the femoral vein into the inferior caval vein and inflated at onset of ischemia. Evans blue and 2,3,5-triphenyltetrazolium chloride were used to determine the myocardial area at risk and infarct size, respectively. Pressure-volume loops were recorded to calculate cardiac work, left ventricular (LV) volumes and ejection fraction. Veno-occlusive unloading reduced infarct size compared with controls (Unloading 13.9 ± 8.2% versus Control 22.4 ± 6.6%; p = 0.04). Unloading increased myocardial salvage (54.8 ± 23.4% vs 28.5 ± 14.0%; p = 0.02), while the area at risk was similar (28.4 ± 6.7% vs 27.4 ± 5.8%; p = 0.74). LV ejection fraction was preserved in the unloaded group, while the control group showed a reduced LV ejection fraction. Veno-occlusive unloading reduced myocardial infarct size and preserved LV ejection fraction in an experimental acute ischemia-reperfusion model. This proof-of-concept study demonstrated the potential of veno-occlusive unloading as an adjunctive cardioprotective therapy in patients undergoing revascularization for acute myocardial infarction.


Assuntos
Coração/fisiopatologia , Infarto do Miocárdio/fisiopatologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Animais , Circulação Coronária/fisiologia , Feminino , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Hemodinâmica/fisiologia , Reperfusão Miocárdica/métodos , Miocárdio/patologia , Suínos , Função Ventricular Esquerda/fisiologia
13.
MAGMA ; 34(1): 57-72, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33502669

RESUMO

OBJECTIVE: Magnetic resonance imaging with hyperpolarized contrast agents can provide unprecedented in vivo measurements of metabolism, but yields images that are lower resolution than that achieved with proton anatomical imaging. In order to spatially localize the metabolic activity, the metabolic image must be interpolated to the size of the proton image. The most common methods for choosing the unknown values rely exclusively on values of the original uninterpolated image. METHODS: In this work, we present an alternative method that uses the higher-resolution proton image to provide additional spatial structure. The interpolated image is the result of a convex optimization algorithm which is solved with the fast iterative shrinkage threshold algorithm (FISTA). RESULTS: Results are shown with images of hyperpolarized pyruvate, lactate, and bicarbonate using data of the heart and brain from healthy human volunteers, a healthy porcine heart, and a human with prostate cancer.


Assuntos
Imageamento por Ressonância Magnética , Algoritmos , Animais , Encéfalo , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Ácido Pirúvico , Suínos
14.
Methods Mol Biol ; 2216: 689-696, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33476031

RESUMO

The signal acquired in sodium (23Na) MR imaging is proportional to the concentration of sodium in a voxel, and it is possible to convert between the two using external calibration phantoms. Postprocessing, and subsequent analysis, of sodium renal images is a simple task that can be performed with readily available software. Here we describe the process of conversion between sodium signal and concentration, estimation of the corticomedullary sodium gradient and the procedure used for quadrupolar relaxation analysis.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This analysis protocol chapter is complemented by two separate chapters describing the basic concept and experimental procedure.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Rim/fisiologia , Imageamento por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Imagens de Fantasmas , Isótopos de Sódio/análise , Animais , Meios de Contraste/química , Imageamento Tridimensional , Ratos , Software
15.
Magn Reson Med ; 85(6): 3510-3521, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33368597

RESUMO

PURPOSE: Increasing worldwide demand for cardiac transplantation has spurred new developments to increase the donor pool. Normothermic preservation of heart grafts for transplantation is an emerging strategy to improve the utilization of marginal grafts. Hyperpolarized MR using metabolic tracers such as [1-13 C]pyruvate, provide a novel means of investigating metabolic status without the use of ionizing radiation. We demonstrate the use of this methodology to examine ex vivo perfused porcine heart grafts. METHODS: Hearts from three 40-kg Danish domestic pigs were harvested and subsequently perfused in Langendorff mode under normothermic conditions, using an MR-compatible perfusion system adapted to the heart. Proton MRI and hyperpolarized [1-13 C]pyruvate were used to investigate and quantify the functional and metabolic status of the grafts. RESULTS: Hearts were perfused with whole blood for 120 min, using a dynamic contrast-enhanced perfusion experiment to verify successful myocardial perfusion. Hyperpolarized [1-13 C]pyruvate MRI was used to assess the metabolic state of the myocardium. Functional assessment was performed using CINE imaging and ventricular pressure data. High lactate and modest alanine levels were observed in the hyperpolarized experiment. The functional assessment produced reduced functional parameters. This suggests an altered functional and metabolic profile compared with corresponding in vivo values. CONCLUSION: We investigated the metabolic and functional status of machine-perfused porcine hearts. Utilizing hyperpolarized methodology to acquire detailed myocardial metabolic information-in combination with already established MR methods for cardiac investigation-provides a powerful tool to aid the progress of donor heart preservation.


Assuntos
Transplante de Coração , Ácido Pirúvico , Animais , Humanos , Imageamento por Ressonância Magnética , Miocárdio , Perfusão , Suínos , Doadores de Tecidos
16.
Front Cardiovasc Med ; 7: 603674, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33244471

RESUMO

Regardless of the importance of acid-base disturbances in cardiac disease, there are currently no methods for clinical detection of pH in the heart. Several magnetic resonance imaging techniques hold translational promise and may enable in-vivo mapping of pH. We provide a brief overview of these emerging techniques. A particular focus is on the promising advance of magnetic resonance spectroscopy and imaging with hyperpolarized 13C-subtrates as biomarkers of myocardial pH. Hyperpolarization allows quantification of key metabolic substrates and their metabolites. Hereby, pH-sensitive reactions can be probed to provide a measure of acid-base alterations. To date, the most used substrates are [1-13C]pyruvate and 13C-labeled bicarbonate; however, others have been suggested. In cardiovascular medicine, hyperpolarized magnetic resonance spectroscopy has been used to probe acid-base disturbances following pharmacological stress, ischemia and heart failure in animals. In addition to pH-estimation, the technique can quantify fluxes such as the pivotal conversion of pyruvate to lactate via lactate dehydrogenase. This capability, a good safety profile and the fact that the technique is employable in clinical scanners have led to recent translation in early clinical trials. Thus, magnetic resonance spectroscopy and imaging may provide clinical pH-imaging in the near future.

17.
NMR Biomed ; 33(10): e4371, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32691467

RESUMO

Renal ischemia-reperfusion injury (IRI) is one of the most common types of acute kidney injury. Spironolactone has shown promising kidney protective effects in renal IRI in rats. We investigated the hemodynamic and metabolic effects of spironolactone (100 mg/kg) administered immediately after 40 min unilateral kidney ischemia in rats. Hyperpolarized MRI using co-polarized [1-13 C]pyruvate and [13 C,15 N2 ]urea as well as 1 H dynamic contrast-enhanced (DCE) MRI was performed 24 h after induction of ischemia. We found a significant decrease in renal blood flow (RBF) in the ischemic kidney compared with the contralateral one measured using DCE and [13 C,15 N2 ]urea. The RBF measured using [1-13 C]pyruvate and [13 C,15 N2 ]urea was significantly altered by spironolactone. The RBFs in the ischemic kidney compared with the contralateral kidney were decreased similarly as measured using both [13 C,15 N2 ]urea and [1-13 C]pyruvate in the spironolactone-treated group. Spironolactone treatment increased the perfusion-corrected pyruvate metabolism by 54% in both the ischemic and contralateral kidney. Furthermore, we showed a correlation between vascular permeability using a histological Evans blue analysis and the ratio of the volumes of distribution (VoDs), ie VoD-[13 C,15 N2 ]urea/VoD-[1-13 C]pyruvate. This suggests that [13 C,15 N2 ]urea/[1-13 C]pyruvate VoD ratio may be a novel indicator of renal vascular permeability associated with renal damage in rodents.


Assuntos
Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/tratamento farmacológico , Hemodinâmica , Imageamento por Ressonância Magnética , Espironolactona/uso terapêutico , Injúria Renal Aguda/fisiopatologia , Análise de Variância , Animais , Permeabilidade Capilar/efeitos dos fármacos , Masculino , Perfusão , Ratos Wistar , Espironolactona/farmacologia , Fatores de Tempo
18.
Magn Reson Med ; 84(5): 2645-2655, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32557782

RESUMO

PURPOSE: Normothermic perfusion is an emerging strategy for donor organ preservation and therapy, incited by the high worldwide demand for organs for transplantation. Hyperpolarized MRI and MRS using [1-13 C]pyruvate and other 13 C-labeled molecules pose a novel way to acquire highly detailed information about metabolism and function in a noninvasive manner. This study investigates the use of this methodology as a means to study and monitor the state of ex vivo perfused porcine kidneys, in the context of kidney graft preservation research. METHODS: Kidneys from four 40-kg Danish domestic pigs were perfused ex vivo with whole blood under normothermic conditions, using an MR-compatible perfusion system. Kidneys were investigated using 1 H MRI as well as hyperpolarized [1-13 C]pyruvate MRI and MRS. Using the acquired anatomical, functional and metabolic data, the state of the ex vivo perfused porcine kidney could be quantified. RESULTS: Four kidneys were successfully perfused for 120 minutes and verified using a DCE perfusion experiment. Renal metabolism was examined using hyperpolarized [1-13 C]pyruvate MRI and MRS, and displayed an apparent reduction in pyruvate turnover compared with the usual case in vivo. Perfusion and blood gas parameters were in the normal ex vivo range. CONCLUSION: This study demonstrates the ability to monitor ex vivo graft metabolism and function in a large animal model, resembling human renal physiology. The ability of hyperpolarized MRI and MRS to directly compare the metabolic state of an organ in vivo and ex vivo, in combination with the simple MR implementation of normothermic perfusion, renders this methodology a powerful future tool for graft preservation research.


Assuntos
Transplante de Rim , Ácido Pirúvico , Animais , Rim/diagnóstico por imagem , Rim/cirurgia , Preservação de Órgãos , Perfusão , Suínos
19.
Magn Reson Med ; 84(2): 519-534, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31960506

RESUMO

PURPOSE: To test a new parallel imaging strategy for acceleration of hyperpolarized 13 C MR acquisitions based on a 3D blipped stack-of-spirals trajectory and conjugate-gradient SENSE reconstruction with precalibrated sensitivities. METHODS: The blipped stack-of-spirals trajectory was developed for an acceleration factor of 4, based on an undersampled stack-of-spirals with gradient blips during spiral readout. The trajectory was developed with volumetric coverage of a large FOV and with high spatial resolution. High temporal resolution was attained through spectral-spatial excitation and 4 excitations per volume. The blipped stack-of-spirals was evaluated in simulations and phantom experiments. Next, the method was evaluated for kidney and cardiac imaging in 2 separate healthy pigs. RESULTS: Simulation and phantom results showed successful acquisition and reconstruction, but also revealed reconstruction challenges for certain locations and for wide signal sources. For the kidney experiment, the accelerated acquisition showed high similarity to 2 separately acquired fully sampled data sets with matched spatial and temporal resolution, respectively. For the cardiac experiment, the accelerated acquisition proved able to map each metabolite in 3 dimensions within a single cardiac cycle. CONCLUSION: The proposed method demonstrated effective mapping of metabolism in both kidneys and the heart of healthy pigs. Limitations seen in phantom experiments, may be irrelevant for most clinical applications, but should be kept in mind as well as reconstruction challenges related to residual aliasing. All in all, we show that the blipped stack-of-spirals is a relevant parallel imaging method for hyperpolarized human imaging, facilitating better insights into metabolism compared with nonaccelerated acquisition.


Assuntos
Algoritmos , Imageamento Tridimensional , Animais , Simulação por Computador , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA