Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Acta Oncol ; 62(10): 1230-1238, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37713179

RESUMO

BACKGROUND AND PURPOSE: Radiotherapy for vulvar carcinoma is challenging due to relatively high risk of locoregional disease recurrence, a technically challenging target, and postoperative lymphocele, and a high risk radiation sequelae. We aim to explore, if it is possible to reduce dose to normal tissue, while maintaining CTV coverage for this patient group with online adaptive radiotherapy. MATERIALS AND METHODS: 20 patients with vulvar carcinoma (527 fractions) were treated with online adaptation on a Varian Ethos accelerator. Setup CBCTs were acquired daily for adaptive planning. Verification CBCTs were acquired immediately prior to dose delivery. CTV dose coverage and dose to bladder and rectum were extracted from the scheduled and adapted plans as well as from adapted plans recalculated based on verification CBCTs. In addition, analysis of the decision of the adaptive procedure was performed for 17 patients (465 fractions). RESULTS: Mean CTV D95% and standard deviation was 98% ± 5% for the scheduled plan compared to 100.0 ± 0.3% and 100.0 ± 0.8% for the adapted plan on the setup and verification CBCT respectively. Dose to OARs varied substantially and did not show any benefit from adaption itself, however a margin reduction was implemented after the first patients treated. The adapted plan was chosen for 63.5% of the fractions and dominant reasons for not adapting were 'no significant dosimetric gain' (75 fractions, 14%) and 'Medical doctor (MD) not available for treatment' (50 fractions, 9.5%). The median adaption time was 15 min and the 25th and 75th percentile was 12 and 17 min, respectively. CONCLUSION: CTVs and PTVs dose coverage were significantly improved with adaptation compared to image-guided RT. This gain was robust during the treatment time.


Assuntos
Carcinoma , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Recidiva Local de Neoplasia , Bexiga Urinária , Pelve , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-35198744

RESUMO

Two multicentre adaptive radiotherapy trials utilising Plan of the Day (PoD) with a library of plans were introduced in 35 centres. The common issues that arose from all centres when introducing PoD were collated retrospectively, through reviewing the data pertaining to the pre-trial and on-trial quality assurance programme. It was found that 1,295 issues arose when introducing PoD in outlining, planning, treatment delivery i.e., PoD selection, and in the overall process of delivering PoD. There was no difference in the number of issues that arose from pre-trial to on-trial. Thus, it is recommended that the implementation of PoD is supported by guidance, reviews, and continuous monitoring.

3.
Phys Med Biol ; 66(4): 045034, 2021 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-33321475

RESUMO

The clinical introduction of hybrid magnetic resonance (MR) guided radiotherapy (RT) delivery systems has led to the need to validate the end-to-end dose delivery performance on such machines. In the current study, an MR visible phantom was developed and used to test the spatial deviation between planned and delivered dose at two 1.5 T MR linear accelerator (MR linac) systems, including pre-treatment imaging, dose planning, online imaging, image registration, plan adaptation, and dose delivery. The phantom consisted of 3D printed plastic and MR visible silicone rubber. It was designed to minimise air gaps close to the radiochromic film used as a dosimeter. Furthermore, the phantom was designed to allow submillimetre, reproducible positioning of the film in the phantom. At both MR linac systems, 54 complete adaptive, MR guided RT workflow sessions were performed. To test the dose delivery performance of the MR linac systems in various adaptive RT (ART) scenarios, the sessions comprised a range of systematic positional shifts of the phantom and imaging or plan adaptation conditions. In each workflow session, the positional translation between the film and the adaptive planned dose was determined. The results showed that the accuracy of the MR linac systems was between 0.1 and 0.9 mm depending on direction. The highest mean deviance observed was in the posterior-anterior direction, and the direction of the error was consistent between centres. The precision of the systems was related to whether the workflow utilized the internal image registration algorithm of the MR linac. Workflows using the internal registration algorithm led to a worse precision (0.2-0.7 mm) compared to workflows where the algorithm was decoupled (0.2 mm). In summary, the spatial deviation between planned and delivered dose of MR-guided ART at the two MR linac systems was well below 1 mm and thus acceptable for clinical use.


Assuntos
Imageamento por Ressonância Magnética , Aceleradores de Partículas , Doses de Radiação , Radioterapia Guiada por Imagem/instrumentação , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Fluxo de Trabalho
4.
BMJ Open ; 10(12): e041005, 2020 12 31.
Artigo em Inglês | MEDLINE | ID: mdl-33384390

RESUMO

INTRODUCTION: Daily radiotherapy delivered with radiosensitisation offers patients with muscle invasive bladder cancer (MIBC) comparable outcomes to cystectomy with functional organ preservation. Most recurrences following radiotherapy occur within the bladder. Increasing the delivered radiotherapy dose to the tumour may further improve local control. Developments in image-guided radiotherapy have allowed bladder tumour-focused 'plan of the day' radiotherapy delivery. We aim to test within a randomised multicentre phase II trial whether this technique will enable dose escalation with acceptable rates of toxicity. METHODS AND ANALYSIS: Patients with T2-T4aN0M0 unifocal MIBC will be randomised (1:1:2) between standard/control whole bladder single plan radiotherapy, standard dose adaptive tumour-focused radiotherapy or dose-escalated adaptive tumour-focused radiotherapy (DART). Adaptive tumour-focused radiotherapy will use a library of three plans (small, medium and large) for treatment. A cone beam CT taken prior to each treatment will be used to visualise the anatomy and inform selection of the most appropriate plan for treatment.Two radiotherapy fractionation schedules (32f and 20f) are permitted. A minimum of 120 participants will be randomised in each fractionation cohort (to ensure 57 evaluable DART patients per cohort).A comprehensive radiotherapy quality assurance programme including pretrial and on-trial components is instituted to ensure standardisation of radiotherapy planning and delivery.The trial has a two-stage non-comparative design. The primary end point of stage I is the proportion of patients meeting predefined normal tissue constraints in the DART group. The primary end point of stage II is late Common Terminology Criteria for Adverse Events grade 3 or worse toxicity aiming to exclude a rate of >20% (80% power and 5% alpha, one sided) in each DART fractionation cohort. Secondary end points include locoregional MIBC control, progression-free survival overall survival and patient-reported outcomes. ETHICS AND DISSEMINATION: This clinical trial is approved by the London-Surrey Borders Research Ethics Committee (15/LO/0539). The results when available will be disseminated via peer-reviewed scientific journals, conference presentations and submission to regulatory authorities. TRIAL REGISTRATION NUMBER: NCT02447549; Pre-results.


Assuntos
Neoplasias da Bexiga Urinária , Cistectomia , Fracionamento da Dose de Radiação , Humanos , Estudos Multicêntricos como Assunto , Recidiva Local de Neoplasia/radioterapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Neoplasias da Bexiga Urinária/radioterapia , Neoplasias da Bexiga Urinária/cirurgia
5.
Artigo em Inglês | MEDLINE | ID: mdl-32095540

RESUMO

INTRODUCTION: Total body irradiation (TBI) is a part of the conditioning regimen for bone marrow transplant.At the Royal Marsden (Sutton, UK) and Rigshospitalet (Copenhagen, Denmark), we introduced a step and shoot IMRT (SS IMRT) technique for TBI. This technique requires no equipment other than that used to deliver other external beam radiation. In this paper, we describe this technique and report on data from the two clinics. MATERIALS AND METHODS: The patients were positioned supine, supported by vacuum bag(s). The entire body of the patients were CT scanned with 5 mm slices. Multiple multi-leaf collimator (MLC) defined fields were used.In-vivo dosimetry was performed at the Royal Marsden for 113 patients.Calculated doses for 18 adult and 4 paediatric patients from Rigshospitalet were extracted. RESULTS: The in-vivo data from the Royal Marsden showed that the mean TLD measured dose difference was -1.9% with a standard deviation of 4.5%.SS IMRT plans for 22 patients from Rigshospitalet resulted in mean doses to the brain, lungs and kidneys all within the range of 11.1-11.8 Gy, while the V(12 Gy) was below 5% for the brain, 2% for the lungs and 0% for the kidneys. DISCUSSION: SS IMRT is feasible for TBI and can deliver targeted doses to the organs at risk.

6.
J Appl Clin Med Phys ; 20(1): 160-167, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30552738

RESUMO

Current clinical practice is to prescribe to 95% of the planning target volume (PTV) in 4D stereotactic body radiotherapy (SBRT) for lung. Frequently the PTV margin has a very low physical density so that the internal target volume (ITV) receives an unnecessarily high dose. This study investigates the alternative of prescribing to the ITV while including the effects of positional uncertainties. Five patients were retrospectively studied with volumetric modulated arc therapy treatment plans. Five plans were produced for each patient: a static plan prescribed to PTV D95% , three probabilistic plans prescribed to ITV D95% and a static plan re-prescribed to ITV D95% after inverse planning. For the three probabilistic plans, the scatter kernel in the dose calculation was convolved with a spatial uncertainty distribution consisting of either a uniform distribution extending ±5 mm in the three orthogonal directions, a distribution consisting of delta functions at ±5 mm, or a Gaussian distribution with standard deviation 5 mm. Median ITV D50% is 23% higher than the prescribed dose for static planning and only 10% higher than the prescribed dose for prescription to the ITV. The choice of uncertainty distribution has less than 2% effect on the median ITV dose. Re-prescribing a static plan and evaluating with a probabilistic dose calculation results in a median ITV D95% which is 1.5% higher than when planning probabilistically. This study shows that a robust probabilistic approach to planning SBRT lung treatments results in the ITV receiving a dose closer to the intended prescription. The exact form of the uncertainty distribution is not found to be critical.


Assuntos
Algoritmos , Neoplasias Pulmonares/cirurgia , Órgãos em Risco/efeitos da radiação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Incerteza
7.
Br J Radiol ; 91(1085): 20170654, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29393674

RESUMO

OBJECTIVE: Literature regarding image-guidance and interfractional motion of the anal canal (AC) during anal cancer radiotherapy is sparse. This study investigates interfractional AC motion during anal cancer radiotherapy. METHODS: Bone matched cone beam CT (CBCT) images were acquired for 20 patients receiving anal cancer radiotherapy allowing population systematic and random error calculations. 12 were selected to investigate interfractional AC motion. Primary anal gross tumour volume and clinical target volume (CTVa) were contoured on each CBCT. CBCT CTVa volumes were compared to planning CTVa. CBCT CTVa volumes were combined into a CBCT-CTVa envelope for each patient. Maximum distortion between each orthogonal border of the planning CTVa and CBCT-CTVa envelope was measured. Frequency, volume and location of CBCT-CTVa envelope beyond the planning target volume (PTVa) was analysed. RESULTS: Population systematic and random errors were 1 and 3 mm respectively. 112 CBCTs were analysed in the interfractional motion study. CTVa varied between each imaging session particularly T location patients of anorectal origin. CTVa border expansions ≥ 1 cm were seen inferiorly, anteriorly, posteriorly and left direction. The CBCT-CTVa envelope fell beyond the PTVa ≥ 50% imaging sessions (n = 5). Of these CBCT CTVa distortions beyond PTVa, 44% and 32% were in the upper and lower thirds of PTVa respectively. CONCLUSION: The AC is susceptible to volume changes and shape deformations. Care must be taken when calculating or considering reducing the PTV margin to the anus. Advances in knowledge: Within a limited field of research, this study provides further knowledge of how the AC deforms during anal cancer radiotherapy.


Assuntos
Neoplasias do Ânus/patologia , Neoplasias do Ânus/radioterapia , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Canal Anal/patologia , Canal Anal/efeitos da radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Dosagem Radioterapêutica , Carga Tumoral
8.
Phys Med Biol ; 63(2): 025008, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29165319

RESUMO

In the forward-projection method of portal dosimetry for volumetric modulated arc therapy (VMAT), the integrated signal at the electronic portal imaging device (EPID) is predicted at the time of treatment planning, against which the measured integrated image is compared. In the back-projection method, the measured signal at each gantry angle is back-projected through the patient CT scan to give a measure of total dose to the patient. This study aims to investigate the practical agreement between the two types of EPID dosimetry for prostate radiotherapy. The AutoBeam treatment planning system produced VMAT plans together with corresponding predicted portal images, and a total of 46 sets of gantry-resolved portal images were acquired in 13 patients using an iViewGT portal imager. For the forward-projection method, each acquisition of gantry-resolved images was combined into a single integrated image and compared with the predicted image. For the back-projection method, iViewDose was used to calculate the dose distribution in the patient for comparison with the planned dose. A gamma index for 3% and 3 mm was used for both methods. The results were investigated by delivering the same plans to a phantom and repeating some of the deliveries with deliberately introduced errors. The strongest agreement between forward- and back-projection methods is seen in the isocentric intensity/dose difference, with moderate agreement in the mean gamma. The strongest correlation is observed within a given patient, with less correlation between patients, the latter representing the accuracy of prediction of the two methods. The error study shows that each of the two methods has its own distinct sensitivity to errors, but that overall the response is similar. The forward- and back-projection EPID dosimetry methods show moderate agreement in this series of prostate VMAT patients, indicating that both methods can contribute to the verification of dose delivered to the patient.


Assuntos
Dosimetria in Vivo/métodos , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Radiometria/métodos , Cintilografia , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
9.
Int J Radiat Oncol Biol Phys ; 99(5): 1234-1242, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-28939224

RESUMO

PURPOSE: To investigate the feasibility of dose escalation and hypofractionation of pelvic lymph node intensity modulated radiation therapy (PLN-IMRT) in prostate cancer (PCa). METHODS AND MATERIALS: In a phase 1/2 study, patients with advanced localized PCa were sequentially treated with 70 to 74 Gy to the prostate and dose-escalating PLN-IMRT at doses of 50 Gy (cohort 1), 55 Gy (cohort 2), and 60 Gy (cohort 3) in 35 to 37 fractions. Two hypofractionated cohorts received 60 Gy to the prostate and 47 Gy to PLN in 20 fractions over 4 weeks (cohort 4) and 5 weeks (cohort 5). All patients received long-course androgen deprivation therapy. Primary outcome was late Radiation Therapy Oncology Group toxicity at 2 years after radiation therapy for all cohorts. Secondary outcomes were acute and late toxicity using other clinician/patient-reported instruments and treatment efficacy. RESULTS: Between August 9, 2000, and June 9, 2010, 447 patients were enrolled. Median follow-up was 90 months. The 2-year rates of grade 2+ bowel/bladder toxicity were as follows: cohort 1, 8.3%/4.2% (95% confidence interval 2.2%-29.4%/0.6%-26.1%); cohort 2, 8.9%/5.9% (4.1%-18.7%/2.3%-15.0%); cohort 3, 13.2%/2.9% (8.6%-20.2%/1.1%-7.7%); cohort 4, 16.4%/4.8% (9.2%-28.4%/1.6%-14.3%); cohort 5, 12.2%/7.3% (7.6%-19.5%/3.9%-13.6%). Prevalence of bowel and bladder toxicity seemed to be stable over time. Other scales mirrored these results. The biochemical/clinical failure-free rate was 71% (66%-75%) at 5 years for the whole group, with pelvic lymph node control in 94% of patients. CONCLUSIONS: This study shows the safety and tolerability of PLN-IMRT. Ongoing and planned phase 3 studies will need to demonstrate an increase in efficacy using PLN-IMRT to offset the small increase in bowel side effects compared with prostate-only IMRT.


Assuntos
Irradiação Linfática/métodos , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Idoso , Antagonistas de Androgênios/uso terapêutico , Estudos de Coortes , Estudos de Viabilidade , Seguimentos , Humanos , Calicreínas/sangue , Masculino , Pessoa de Meia-Idade , Pelve , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/patologia , Hipofracionamento da Dose de Radiação , Fatores de Tempo
10.
Br J Radiol ; 90(1072): 20160915, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28205452

RESUMO

OBJECTIVE: Towards Safer Radiotherapy recommended that radiotherapy (RT) centres should have protocols in place for in vivo dosimetry (IVD) monitoring at the beginning of patient treatment courses (Donaldson S. Towards safer radiotherapy. R Coll Radiol 2008). This report determines IVD implementation in the UK in 2014, the methods used and makes recommendations on future use. METHODS: Evidence from peer-reviewed journals was used in conjunction with the first survey of UK RT centre IVD practice since the publication of Towards Safer Radiotherapy. In March 2014, profession-specific questionnaires were sent to radiographer, clinical oncologist and physics staff groups in each of the 66 UK RT centres. RESULTS: Response rates from each group were 74%, 45% and 74%, respectively. 73% of RT centres indicated that they performed IVD. Diodes are the most popular IVD device. Thermoluminescent dosimeter (TLD) is still in use in a number of centres but not as a sole modality, being used in conjunction with diodes and/or electronic portal imaging device (EPID). The use of EPID dosimetry is increasing and is considered of most potential value for both geometric and dosimetric verification. CONCLUSION: Owing to technological advances, such as electronic data transfer, independent monitor unit checking and daily image-guided radiotherapy, the overall risk of adverse treatment events in RT has been substantially reduced. However, the use of IVD may prevent a serious radiation incident. Point dose IVD is not considered suited to the requirements of verifying advanced RT techniques, leaving EPID dosimetry as the current modality likely to be developed as a future standard. Advances in knowledge: An updated perspective on UK IVD use and provision of professional guidelines for future implementation.


Assuntos
Dosimetria in Vivo/métodos , Dosímetros de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Humanos , Dosagem Radioterapêutica , Inquéritos e Questionários , Dosimetria Termoluminescente , Reino Unido
11.
Radiother Oncol ; 120(2): 320-6, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27470308

RESUMO

BACKGROUND AND PURPOSE: Delivering selected parts of volumetric modulated arc therapy (VMAT) plans using step-and-shoot intensity modulated radiotherapy (IMRT) beams has the potential to increase plan quality by allowing specific aperture positioning. This study investigates the quality of treatment plans and the accuracy of in vivo portal dosimetry in such a hybrid approach for the case of prostate radiotherapy. MATERIAL AND METHODS: Conformal and limited-modulation VMAT plans were produced, together with five hybrid IMRT/VMAT plans, in which 0%, 25%, 50%, 75% or 100% of the segments were sequenced for IMRT, while the remainder were sequenced for VMAT. Integrated portal images were predicted for the plans. The plans were then delivered as a single hybrid beam using an Elekta Synergy accelerator with Agility head to a water-equivalent phantom and treatment time, isocentric dose and portal images were measured. RESULTS: Increasing the IMRT percentage improves dose uniformity to the planning target volume (p<0.01 for 50% IMRT or more), substantially reduces the volume of rectum irradiated to 65Gy (p=0.02 for 25% IMRT) and increases the monitor units (p<0.001). Delivery time also increases substantially. All plans show accurate delivery of dose and reliable prediction of portal images. CONCLUSIONS: Hybrid IMRT/VMAT can be efficiently planned and delivered as a single beam sequence. Beyond 25% IMRT, the delivery time becomes unacceptably long, with increased risk of intrafraction motion, but 25% IMRT is an attractive compromise. Integrated portal images can be used to perform in vivo dosimetry for this technique.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Dosimetria in Vivo , Fígado/efeitos da radiação , Masculino , Posicionamento do Paciente , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Reto/efeitos da radiação , Estudos Retrospectivos
12.
Radiother Oncol ; 120(2): 356-62, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27222296

RESUMO

BACKGROUND AND PURPOSE: Magnetic resonance (MR) and computed tomography (CT) images are degraded in the presence of metallic implants. We investigate whether SEMAC (Slice Encoding for Metal Artifact Correction) MR is advantageous for radiotherapy (RT) planning. METHODS: Conventional and SEMAC MR protocols were compared (1.5T). A spine fixation device suspended in gelatine, two patients with spine fixation devices and six patients with bilateral hip replacements were scanned with both conventional and SEMAC protocols. In spine patients the visibility of the spinal canal and spinal cord was assessed; in prostate patients, the visibility of the prostate, pelvic structures and the pelvic girdle. RESULTS: The signal loss volume surrounding the spine fixation device was reduced by approximately 20% when the SEMAC protocol was employed, and registration errors were reduced. For spine patients, the spinal canal was completely visible only using the SEMAC protocol. In hip replacement patients, metal artifacts were local; the signal loss extended to the internal surface of the acetabulum in eight implants with conventional protocols, but only in four using SEMAC. CONCLUSIONS: SEMAC MR contributes towards correct co-registration of MR and CT images for RT planning, and is particularly relevant when the TV or OARs are close to implants.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Planejamento da Radioterapia Assistida por Computador/métodos , Artefatos , Fixação Interna de Fraturas/instrumentação , Humanos , Aumento da Imagem , Masculino , Metais , Neoplasias da Próstata/radioterapia , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
13.
Br J Radiol ; 89(1063): 20150933, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27109735

RESUMO

OBJECTIVE: To evaluate three image acquisition presets for four-dimensional cone beam CT (CBCT) to identify an optimal preset for lung tumour image quality while minimizing dose and acquisition time. METHODS: Nine patients undergoing radical conventionally fractionated radiotherapy for lung cancer had verification CBCTs acquired using three presets: Preset 1 on Day 1 (11 mGy dose, 240 s acquisition time), Preset 2 on Day 2 (9 mGy dose, 133 s acquisition time) and Preset 3 on Day 3 (9 mGy dose, 67 s acquisition time). The clarity of the tumour and other thoracic structures, and the acceptability of the match, were retrospectively graded by visual grading analysis (VGA). Logistic regression was used to identify the most appropriate preset and any factors that might influence the result. RESULTS: Presets 1 and 2 met a clinical requirement of 75% of structures to be rated "Clear" or above and 75% of matches to be rated "Acceptable" or above. Clarity is significantly affected by preset, patient, observer and structure. Match acceptability is significantly affected by preset. CONCLUSION: The application of VGA in this initial study enabled a provisional selection of an optimal preset (Preset 2) to be made. ADVANCES IN KNOWLEDGE: This was the first application of VGA to the investigation of presets for CBCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Humanos , Pulmão/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
14.
Int J Radiat Oncol Biol Phys ; 94(5): 1022-30, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27026308

RESUMO

PURPOSE: Image guided adaptive radiation therapy offers individualized solutions to improve target coverage and reduce normal tissue irradiation, allowing the opportunity to increase the radiation tumor dose and spare normal bladder tissue. METHODS AND MATERIALS: A library of 3 intensity modulated radiation therapy plans were created (small, medium, and large) from planning computed tomography (CT) scans performed at 30 and 60 minutes; treating the whole bladder to 52 Gy and the tumor to 70 Gy in 32 fractions. A "plan of the day" approach was used for treatment delivery. A post-treatment cone beam CT (CBCT) scan was acquired weekly to assess intrafraction filling and coverage. RESULTS: A total of 18 patients completed treatment to 70 Gy. The plan and treatment for 1 patient was to 68 Gy. Also, 1 patient's plan was to 70 Gy but the patient was treated to a total dose of 65.6 Gy because dose-limiting toxicity occurred before dose escalation. A total of 734 CBCT scans were evaluated. Small, medium, and large plans were used in 36%, 48%, and 16% of cases, respectively. The mean ± standard deviation rate of intrafraction filling at the start of treatment (ie, week 1) was 4.0 ± 4.8 mL/min (range 0.1-19.4) and at end of radiation therapy (ie, week 5 or 6) was 1.1 ± 1.6 mL/min (range 0.01-7.5; P=.002). The mean D98 (dose received by 98% volume) of the tumor boost and bladder as assessed on the post-treatment CBCT scan was 97.07% ± 2.10% (range 89.0%-104%) and 99.97% ± 2.62% (range 96.4%-112.0%). At a median follow-up period of 19 months (range 4-33), no muscle-invasive recurrences had developed. Two patients experienced late toxicity (both grade 3 cystitis) at 5.3 months (now resolved) and 18 months after radiation therapy. CONCLUSIONS: Image guided adaptive radiation therapy using intensity modulated radiation therapy to deliver a simultaneous integrated tumor boost to 70 Gy is feasible, with acceptable toxicity, and will be evaluated in a randomized trial.


Assuntos
Tratamentos com Preservação do Órgão/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Bexiga Urinária/radioterapia , Idoso , Idoso de 80 Anos ou mais , Quimioterapia Adjuvante , Cisplatino/administração & dosagem , Desoxicitidina/administração & dosagem , Desoxicitidina/análogos & derivados , Estudos de Viabilidade , Seguimentos , Humanos , Dose Máxima Tolerável , Pessoa de Meia-Idade , Invasividade Neoplásica , Recidiva Local de Neoplasia/patologia , Órgãos em Risco/efeitos da radiação , Estudos Prospectivos , Lesões por Radiação/prevenção & controle , Radiossensibilizantes/uso terapêutico , Radiografia , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/estatística & dados numéricos , Radioterapia de Intensidade Modulada/estatística & dados numéricos , Fatores de Tempo , Bexiga Urinária/efeitos da radiação , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Gencitabina
15.
Radiother Oncol ; 118(1): 154-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26631646

RESUMO

BACKGROUND AND PURPOSE: Adaptive radiotherapy (ART) using plan selection is being introduced clinically for bladder cancer, but the challenge of how to compensate for intra-fractional motion remains. The purpose of this study was to assess target coverage with respect to intra-fractional motion and the potential for normal tissue sparing in MRI-guided ART (MRIGART) using isotropic (MRIGARTiso), an-isotropic (MRIGARTanIso) and population-based margins (MRIGARTpop). MATERIALS AND METHODS: Nine bladder cancer patients treated in a phase II trial of plan selection underwent 6-7 weekly repeat MRI series, each with volumetric scans acquired over a 10 min period. Adaptive re-planning on the 0 min MRI scans was performed using density override, simulating a hypo-fractionated schedule. Target coverage was evaluated on the 10 min scan to quantify the impact of intra-fractional motion. RESULTS: MRIGARTanIso reduced the course-averaged PTV by median 304 cc compared to plan selection. Bladder shifts affected target coverage in individual fractions for all strategies. Two patients had a v95% of the bladder below 98% for MRIGARTiso. MRIGARTiso decreased the bowel V25 with 15-46 cc compared to MRIGARTpop. CONCLUSION: Online re-optimised ART has a considerable normal tissue sparing potential. MRIGART with online corrections for target shift during a treatment fraction should be considered in ART for bladder cancer.


Assuntos
Imageamento por Ressonância Magnética/métodos , Radioterapia Guiada por Imagem , Neoplasias da Bexiga Urinária/radioterapia , Feminino , Humanos , Masculino , Planejamento da Radioterapia Assistida por Computador/métodos
16.
Strahlenther Onkol ; 191(12): 970-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26403913

RESUMO

PURPOSE: The aim of this work was to compare and validate various computed tomography (CT) number calibration techniques with respect to cone beam CT (CBCT) dose calculation accuracy. METHODS: CBCT dose calculation accuracy was assessed for pelvic, lung, and head and neck (H&N) treatment sites for two approaches: (1) physics-based scatter correction methods (CBCTr); (2) density override approaches including assigning water density to the entire CBCT (W), assignment of either water or bone density (WB), and assignment of either water or lung density (WL). Methods for CBCT density assignment within a commercially available treatment planning system (RSauto), where CBCT voxels are binned into six density levels, were assessed and validated. Dose-difference maps and dose-volume statistics were used to compare the CBCT dose distributions with the ground truth of a planning CT acquired the same day as the CBCT. RESULTS: For pelvic cases, all CTN calibration methods resulted in average dose-volume deviations below 1.5 %. RSauto provided larger than average errors for pelvic treatments for patients with large amounts of adipose tissue. For H&N cases, all CTN calibration methods resulted in average dose-volume differences below 1.0 % with CBCTr (0.5 %) and RSauto (0.6 %) performing best. For lung cases, WL and RSauto methods generated dose distributions most similar to the ground truth. CONCLUSION: The RSauto density override approach is an attractive option for CTN adjustments for a variety of anatomical sites. RSauto methods were validated, resulting in dose calculations that were consistent with those calculated on diagnostic-quality CT images, for CBCT images acquired of the lung, for patients receiving pelvic RT in cases without excess adipose tissue, and for H&N cases.


Assuntos
Calibragem , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Otorrinolaringológicas/radioterapia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Bexiga Urinária/radioterapia , Algoritmos , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Radiometria/métodos , Dosagem Radioterapêutica , Espalhamento de Radiação
17.
Radiother Oncol ; 117(3): 491-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26277856

RESUMO

BACKGROUND AND PURPOSE: The latency of a multileaf collimator (MLC) tracking system used to overcome respiratory motion causes misalignment of the treatment beam with respect to the gross tumour volume, which may result in reduced target coverage. This study investigates the magnitude of this effect. MATERIAL AND METHODS: Simulated superior-inferior breathing motion was used to construct histograms of isocentre offset with respect to the gross tumour volume (GTV) for a variety of tracking latencies. Dose distributions for conformal volumetric modulated arc therapy (VMAT) arcs were then calculated at a range of offsets and summed according to these displacement histograms. The results were verified by delivering the plans to a Delta(4) phantom on a motion platform. RESULTS: In the absence of an internal target margin, a tracking latency of 150 ms reduces the GTV D95% by approximately 2%. With a margin of 2 mm, the same drop in dose occurs for a tracking latency of 450 ms. Lung V(13Gy) is unaffected by a range of latencies. These results are supported by the phantom measurements. CONCLUSIONS: Assuming that internal motion can be modelled by a rigid translation of the patient, MLC tracking of conformal VMAT can be effectively accomplished in the absence of an internal target margin for substantial breathing motion (4 s period and 20 mm peak-peak amplitude) so long as the system latency is less than 150 ms.


Assuntos
Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Imageamento Tridimensional , Neoplasias Pulmonares/patologia , Movimento (Física) , Dosagem Radioterapêutica , Respiração , Estudos Retrospectivos
18.
Br J Radiol ; 88(1054): 20150208, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26246041

RESUMO

OBJECTIVE: Cone beam CT (CBCT) enables soft-tissue registration to planning CT for position verification in radiotherapy. The aim of this study was to determine the interobserver error (IOE) in prostate position verification using a standard CBCT protocol, and the effect of reducing CBCT scan length or increasing exposure, compared with standard imaging protocol. METHODS: CBCT images were acquired using a novel 7 cm length image with standard exposure (1644 mAs) at Fraction 1 (7), standard 12 cm length image (1644 mAs) at Fraction 2 (12) and a 7 cm length image with higher exposure (2632 mAs) at Fraction 3 (7H) on 31 patients receiving radiotherapy for prostate cancer. Eight observers (two clinicians and six radiographers) registered the images. Guidelines and training were provided. The means of the IOEs were compared using a Kruzkal-Wallis test. Levene's test was used to test for differences in the variances of the IOEs and the independent prostate position. RESULTS: No significant difference was found between the IOEs of each image protocol in any direction. Mean absolute IOE was the greatest in the anteroposterior direction. Standard deviation (SD) of the IOE was the least in the left-right direction for each of the three image protocols. The SD of the IOE was significantly less than the independent prostate motion in the anterior-posterior (AP) direction only (1.8 and 3.0 mm, respectively: p = 0.017). IOEs were within 1 SD of the independent prostate motion in 95%, 77% and 96% of the images in the RL, SI and AP direction. CONCLUSION: Reducing CBCT scan length and increasing exposure did not have a significant effect on IOEs. To reduce imaging dose, a reduction in CBCT scan length could be considered without increasing the uncertainty in prostate registration. Precision of CBCT verification of prostate radiotherapy is affected by IOE and should be quantified prior to implementation. ADVANCES IN KNOWLEDGE: This study shows the importance of quantifying the magnitude of IOEs prior to CBCT implementation.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Humanos , Masculino , Movimento (Física) , Variações Dependentes do Observador , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes
20.
Phys Med Biol ; 59(19): N171-9, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25211121

RESUMO

Using an Electronic Portal Imaging Device (EPID) to perform in-vivo dosimetry is one of the most effective and efficient methods of verifying the safe delivery of complex radiotherapy treatments. Previous work has detailed the development of an EPID based in-vivo dosimetry system that was subsequently used to replace pre-treatment dose verification of IMRT and VMAT plans. Here we show that this system can be readily implemented on a commercial megavoltage imaging platform without modification to EPID hardware and without impacting standard imaging procedures. The accuracy and practicality of the EPID in-vivo dosimetry system was confirmed through a comparison with traditional TLD in-vivo measurements performed on five prostate patients.The commissioning time required for the EPID in-vivo dosimetry system was initially prohibitive at approximately 10 h per linac. Here we present a method of calculating linac specific EPID dosimetry correction factors that allow a single energy specific commissioning model to be applied to EPID data from multiple linacs. Using this method reduced the required per linac commissioning time to approximately 30 min.The validity of this commissioning method has been tested by analysing in-vivo dosimetry results of 1220 patients acquired on seven linacs over a period of 5 years. The average deviation between EPID based isocentre dose and expected isocentre dose for these patients was (-0.7  ±  3.2)%.EPID based in-vivo dosimetry is now the primary in-vivo dosimetry tool used at our centre and has replaced nearly all pre-treatment dose verification of IMRT treatments.


Assuntos
Eletrônica/instrumentação , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Radiometria/instrumentação , Radiometria/métodos , Algoritmos , Humanos , Masculino , Aceleradores de Partículas/instrumentação , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...