Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 48(23): 6320-6323, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38039257

RESUMO

We report on efficient and stable, type-I phase-matched second harmonic conversion of a nanosecond high-energy, diode-pumped, Yb:YAG laser. With a frequency-doubling crystal in an enclosed, temperature controller with optical windows, 0.5% energy stability was achieved for approximately half an hour. This resulted in 48.9 J pulses at 10 Hz (489 W) and a conversion efficiency of 73.8%. These results are particularly important for stable and reliable operation of high-energy, frequency-doubled lasers.

2.
Opt Lett ; 48(13): 3471-3474, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37390158

RESUMO

We report the first-ever, to the best of our knowledge, demonstration of the optical isolation of a kilowatt average power pulsed laser. A Faraday isolator capable of stable protection of the laser amplifier chain delivering 100 J nanosecond laser pulses at the repetition rate of 10 Hz has been developed and successfully tested. The isolator provided an isolation ratio of 30.46 dB in the course of an hour-long testing run at full power without any noticeable decrease due to the thermal effects. This is the first-ever, to the best of our knowledge, demonstration of a nonreciprocal optical device operated with such a powerful high-energy, high-repetition-rate laser beam, opening up the possibilities for this type of laser to be used for a number of industrial and scientific applications.


Assuntos
Lasers , Dispositivos Ópticos , Luz , Frequência Cardíaca
3.
Opt Lett ; 46(22): 5771-5773, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34780458

RESUMO

We report on obtaining output energy of 146 J in 10 ns long pulses at 10 Hz repetition rate from Bivoj, a multi-Joule multi-slab cryogenic gas-cooled diode pumped solid state laser, by overcoming its damage threshold bottleneck. This is a 40% energy and power increase of the laser system in comparison to our previous publication and to the most powerful multi-Joule high power laser system.

4.
Ultramicroscopy ; 163: 1-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26855204

RESUMO

Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications.

5.
Int Orthop ; 39(1): 125-30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25128968

RESUMO

PURPOSE: The incidence of an anterior cruciate ligament (ACL) tear is highest in female patients; however, it is not apparent whether graft choice affects clinical results. The aim of this prospective randomised study was to evaluate clinical results of an ACL reconstruction using patellar tendon [bone-patellar tendon-bone (BTB)] or hamstring graft (HS) in female patients. METHODS: Inclusion criteria were traumatic instability, no signs of osteoarthritis, no previous instability and no contralateral knee instability. Inclusion criteria were met in 150 patients, mean age 26 (17-47) years. Patients were randomised into two groups of 75 patients according to graft type; all had the same rehabilitation protocol. Tegner Lysholm knee score and stability were evaluated pre-operatively and one and two years postoperatively. The difference between groups was statistically evaluated using unpaired t test. RESULTS: Of the 150 patients, all completed one year follow-up; three were lost to follow-up at two years. There was no significant difference in functional scores and knee stability between groups. The HS group had significantly less anterior knee pain in the first six months postoperatively. CONCLUSION: ACL reconstruction significantly improves clinical results and stability of the knee. Difference in Lysholm score and stability between groups was not significant. Neither group showed higher tendency to graft failure within two years. Graft choice for reconstruction in female patients should be surgeon specific and individualised, as both grafts studied achieved comparable results.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Traumatismos do Joelho/cirurgia , Músculo Esquelético/cirurgia , Ligamento Patelar/cirurgia , Tendões/transplante , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior , Autoenxertos , Feminino , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Transplante Autólogo , Resultado do Tratamento , Adulto Jovem
6.
Nephrol Nurs J ; 39(3): 239-43, 255, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22866363

RESUMO

This study investigated mixing sevelamer carbonate powder with foods and beverages other than water. Food samples, including applesauce, oatmeal, chicken, protein powder, scrambled eggs, ginger ale, and diet ginger ale, were subjected to an in vitro assay, and the difference in the amount of phosphate bound between samples pre-exposed to foods and samples where the drug was exposed to foods concurrently was determined Under these assay conditions, pre-exposure to sevelamer carbonate powder had no effect on the ability to bind phosphate. Clinical testing is needed to further evaluate this finding.


Assuntos
Bebidas , Quelantes/administração & dosagem , Alimentos , Hiperfosfatemia/prevenção & controle , Falência Renal Crônica/complicações , Poliaminas/administração & dosagem , Diálise Renal/efeitos adversos , Quelantes/farmacologia , Análise de Alimentos , Humanos , Concentração de Íons de Hidrogênio , Hiperfosfatemia/sangue , Hiperfosfatemia/etiologia , Técnicas In Vitro , Poliaminas/farmacologia , Pós , Sevelamer , Suspensões
7.
Int Orthop ; 35(11): 1733-9, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21243357

RESUMO

OBJECTIVE: Improved staging of cartilage degeneration is required, particularly during the early stages. We correlated mechanical properties with histological and macroscopic findings. METHODS: One hundred and twenty cartilage samples were obtained during total knee arthroplasty. Two adjacent plugs were harvested--one for histological classification and one for macroscopic and biomechanical purposes. Dynamic impact testing was performed; normal stress, dissipated energy (∆E), tangent modulus and stiffness were evaluated. RESULTS: Samples were classified according to six categories of the ICRS histological scale. Mechanical characteristics revealing significant differences between the groups (p < 0.01) were specific damping and related absolute ∆E. A significant correlation was found between the macroscopic score and specific damping, as well as absolute and relative ∆E (p < 0.01). A strong relation was revealed between relative ∆E and cartilage thickness (p < 0.001; R (2) = 0.69). CONCLUSIONS: Only ∆E correlated with the condition of the cartilage--the value increased with decreasing quality-and is the most suitable characteristic. This change appears substantial in initial stages of cartilage deterioration.


Assuntos
Cartilagem Articular/patologia , Osteoartrite do Joelho/patologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Força Compressiva , Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Estresse Mecânico
8.
J Pharm Sci ; 95(12): 2751-9, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16937334

RESUMO

It has been previously reported that anions in common beverages may bind to bile acid sequestrants (BAS), reducing their capacity for binding bile acid salts. This study examined the ability of the novel BAS colesevelam hydrochloride (HCl), in vitro, to bind bile acid sodium salts following suspension in common beverages. Equilibrium binding was evaluated under conditions of constant time and varying concentrations of bile acid salts in simulated intestinal fluid (SIF). A stock solution of sodium salts of glycochenodeoxycholic acid (GCDC), taurodeoxycholic acid (TDC), and glycocholic acid (GC), was added to each prepared sample of colesevelam HCl. Bile acid salt binding was calculated by high-performance liquid chromatography (HPLC) analysis. Kinetics experiments were conducted using constant initial bile acid salt concentrations and varying binding times. The affinity, capacity, and kinetics of colesevelam HCl binding for GCDC, TDC, and GC were not significantly altered after suspension in water, carbonated water, Coca-Cola, Sprite, grape juice, orange juice, tomato juice, or Gatorade. The amount of bile acid sodium salt bound as a function of time was unchanged by pretreatment with any beverage tested. The in vitro binding characteristics of colesevelam HCl are unchanged by suspension in common beverages.


Assuntos
Alilamina/análogos & derivados , Anticolesterolemiantes/metabolismo , Bebidas , Ácido Glicoquenodesoxicólico/metabolismo , Ácido Glicocólico/metabolismo , Ácido Taurodesoxicólico/metabolismo , Alilamina/metabolismo , Cloridrato de Colesevelam , Secreções Intestinais/química
9.
J Ren Nutr ; 16(3): 248-52, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16825030

RESUMO

Sevelamer, a nonabsorbed, calcium- and metal-free dietary phosphate binder, consists of a polyallylamine polymer backbone with a cationic charge that shows a high capacity for binding anionically charged compounds such as phosphate. The currently licensed form of sevelamer, Renagel, exists as sevelamer hydrochloride, which disassociates in the acidic environment of the stomach and early gastrointestinal tract, exchanging the chloride ions attached to the polymer backbone for phosphate ions. The resulting absorption of these chloride ions has been reported to be accompanied by a reduction in serum levels of bicarbonate in some patients. To minimize the possibility of this effect, a new salt form of sevelamer has been developed in which carbonate replaces the chloride counter ion, thereby providing a source of buffer. The majority of phosphate binders exist only in tablet form and are dosed three times per day with meals. Genzyme has developed sevelamer carbonate in tablet form and also as a powder formulation that can be taken after mixing with water. This allows for an alternate and potentially more palatable way of dosing. Preliminary data exist suggesting that once daily dosing with sevelamer hydrochloride tablets provides similar phosphate control to three times daily dosing. By providing novel dosage forms and regimens for sevelamer-based phosphate binders, Genzyme will be providing patients and health care providers additional choices and flexibility in controlling phosphorus levels in chronic kidney disease. This should translate to increased compliance and improved rates of phosphate control.


Assuntos
Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Fosfatos/sangue , Poliaminas/administração & dosagem , Diálise Renal , Animais , Bicarbonatos/sangue , Cloretos/química , Cães , Humanos , Cinética , Cooperação do Paciente , Fosfatos/química , Fósforo/sangue , Poliaminas/química , Poliaminas/farmacocinética , Sevelamer
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA