1.
Radiat Prot Dosimetry ; 198(9-11): 566-572, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005955

RESUMO

A proof-of-concept study of a new detector based on a thin plastic scintillator monitored by a Charge-Coupled Device (CCD) camera designed for monitoring and characterisation of Linac photon beams is presented. The response of the detector is compared with radiochromic film using 6 and 18 MV radiotherapeutic beams. We have observed: (i) all instruments survived the secondary radiation fields during Linac operation, (ii) it was possible to process the measured data using statistical techniques and (iii) the processed data from the CCD camera qualitatively correspond to film dosimetry results. A statistical technique based on the selection of minimal values provides the clearest results. Quantitatively, CCD and film results can only be compared as 6 to 18 MV response rates. We have observed that the rates from the CCD data are systematically higher than the rates from film dosimetry. Differences are not too high, namely 1.9-2.4 times the combined standard deviation.


Assuntos
Aceleradores de Partículas , Plásticos , Dosimetria Fotográfica/métodos , Radiometria
2.
Radiat Prot Dosimetry ; 186(2-3): 362-366, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31943097

RESUMO

This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with electronic detectors within the measured plane and comparable in other directions. It is readily available at clinics because it uses existing resources-a slab phantom and EBT3 films. The method was tested on six IMRT clinical cases. An in-house code for 2D and pseudo-3D gamma analysis was written in MATLAB and compared to OmniPro I'mRT.


Assuntos
Dosimetria Fotográfica/instrumentação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Dosimetria Fotográfica/métodos , Raios gama , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
3.
Phys Med Biol ; 63(11): 115014, 2018 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-29726411

RESUMO

Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.


Assuntos
Terapia com Prótons/instrumentação , Prótons , Espectrometria gama/instrumentação , Humanos , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiometria/instrumentação , Espectrometria gama/métodos