1.
Ticks Tick Borne Dis ; 12(1): 101559, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33137638

RESUMO

Micro-computed tomography (micro-CT) is an exceptional imaging modality which is limited in visualizing soft biological tissues that need pre-examination contrasting steps, which can cause serious deformation to sizeable specimens like engorged ticks. The aim of this study was to develop a new technique to bypass these limitations and allow the imaging of fed ticks in their natural state. To accomplish this, adult Ixodes ricinus females were allowed to engorge in vitro on blood supplemented with PEGylated gold nanoparticles (PEG-AuNPs). In total, 73/120 females divided into 6 groups engorged on blood enriched with 0.07-2.16 mg PEG-AuNPs per ml of blood. No toxic effect was observed for any of the tested groups compared to the control group, in which 12/20 females engorged on clear blood. The ticks were scanned on a Bruker micro-CT SkyScan 1276. The mean radiodensity of the examined ticks exceeded 0 Hounsfield Units only in the case of the two groups with the highest concentration. The best contrast was observed in ticks engorged on blood with the highest tested concentration of 2.16 mg/mL PEG-AuNPs. In these ticks, the midgut and rectal sac were clearly visible. Also, the midgut lumen volume was computed from segmented image data. The reduction in midgut volume was documented during the egg development process. According to this pilot study, micro-CT of ticks engorged on blood supplemented with contrasting agents in vitro may reveal additional information regarding the engorged ticks' anatomy.


Assuntos
Ouro , Ixodes , Nanopartículas Metálicas , Microtomografia por Raio-X/métodos , Animais , Sangue , Comportamento Alimentar , Feminino
2.
Artigo em Inglês | MEDLINE | ID: mdl-25965688

RESUMO

This study presents three methods for absolute quantification in ultrasound perfusion analysis based on bolus tracking. The first two methods deconvolve the perfusion time sequence with a measured AIF, using a nonparametric or a parametric model of the tissue residue function, respectively. The third method is a simplified approach avoiding deconvolution by assuming a narrow AIF. A phantom with a dialyzer filter as a tissue-mimicking model was used for evaluation. Estimated mean transit times and blood volumes were compared with the theoretical values. A match with a maximum error of 12% was achieved.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão/métodos , Imagens de Fantasmas , Ultrassonografia/métodos , Desenho de Equipamento , Humanos , Modelos Cardiovasculares , Imagem de Perfusão/instrumentação , Processamento de Sinais Assistido por Computador , Ultrassonografia/instrumentação
3.
Artigo em Inglês | MEDLINE | ID: mdl-23357905

RESUMO

A new signal model and processing method for quantitative ultrasound perfusion analysis is presented, called bolus-and-burst. The method has the potential to provide absolute values of blood flow, blood volume, and mean transit time. Furthermore, it provides an estimate of the local arterial input function which characterizes the arterial tree, allowing accurate estimation of the bolus arrival time. The method combines two approaches to ultrasound perfusion analysis: bolus-tracking and burst-replenishment. A pharmacokinetic model based on the concept of arterial input functions and tissue residue functions is used to model both the bolus and replenishment parts of the recording. The pharmacokinetic model is fitted to the data using blind deconvolution. A preliminary assessment of the new perfusion-analysis method is presented on clinical recordings.


Assuntos
Meios de Contraste/farmacocinética , Modelos Teóricos , Perfusão/métodos , Processamento de Sinais Assistido por Computador , Ultrassonografia/métodos , Algoritmos , Doença de Crohn/diagnóstico por imagem , Bases de Dados Factuais , Diagnóstico por Imagem , Hemodinâmica , Humanos , Artéria Ilíaca/diagnóstico por imagem , Farmacocinética
4.
Physiol Meas ; 34(2): 151-62, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23348425

RESUMO

Dynamic contrast-enhanced ultrasound (DCE-US) imaging is a promising diagnostic method, which enables the evaluation of tissue perfusion via different parameters. The mean transit time and time-to-peak parameters are the main time parameters and their values depend on the model used for the approximation of the noisy perfusion curves. In this paper, we described a new comparison of different perfusion models using a tissue mimicking phantom. The following models were compared: log-normal, lagged, Erlang, Gamma and the local density random walk model. We discovered that the mean-square error is not the best criterion for model evaluation. More important is the comparison between the estimated time perfusion parameters and the physical parameters of the developed tissue mimicking phantom. Based on the statistical analysis, we can suggest that for the DCE-US perfusion analysis more models should be used, excluding the log-normal model, which gives the highest error of mean transit time value.


Assuntos
Algoritmos , Meios de Contraste/análise , Meios de Contraste/farmacocinética , Técnicas de Diluição do Indicador , Modelos Biológicos , Ultrassonografia/métodos , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade