J Appl Clin Med Phys ; 24(9): e14043, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37254641

RESUMO

PURPOSE: To investigate the dosimetric effect of six degrees of freedom (6DoF) couch top with rotational corrections in proton therapy (PT). METHODS: The water equivalent thickness (WET) was measured using a proton beam with a 6DoF couch top and patient immobilization base plate (PIBP) placed in front of a motorized water phantom. The accuracy verification was performed with the beam axis set perpendicular to the 6DoF couch top and tilted in 10° steps from 10° to 30°. Up to 3° rotational correction may be added during the actual treatment to correct the rotational setup error on our system. The measured and calculated values using the treatment planning system were compared. Additionally, the effect of the 3° difference was evaluated using actual measurements concerning each angle on the proton beam range. RESULTS: The WET of the 6DoF couch top and PIBP were 8.5 ± 0.1 mm and 6.8 ± 0.1 mm, respectively. The calculation and the actual measurement at each angle agreed within 0.2 mm at the maximum. A maximum difference of approximately 0.6 mm was confirmed when tilted at 3° following 30° with the 6DoF couch top plus PIBP. CONCLUSIONS: The dosimetric effect of the 6DoF couch top with rotational corrections in PT differs depending on the incidence angle on the couch top, and it increased with the increased oblique angle of incidence. However, the effect on the range was as small as 0.6 mm at the maximum. The amount of rotational correction, the angle of incidence of the beam, and the effect of rotational corrections on the proton beam range may differ depending on the structure of the couch top. Therefore, sufficient prior confirmation, and subsequent periodical quality assurance management are important.


Assuntos
Terapia com Prótons , Humanos , Posicionamento do Paciente , Prótons , Radiometria , Planejamento da Radioterapia Assistida por Computador
4.
Appl Radiat Isot ; 188: 110397, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35933906

RESUMO

We aimed to evaluate dosimetric effects of ipsilateral shoulder position variations (ISPVs) in sitting-positioned boron neutron capture therapy (BNCT) for lower neck tumor. The ISPVs were simulated using deformed shoulder images that can simulate arbitrary shape. The dose-volume parameters for the tumor in the rotated shoulder plans considerably varied compared with that for the mucosa. Even in a small number of cases, these differences were clearly observed among patients. The ISPVs in lower neck BNCT have great dosimetric effects.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço , Compostos de Boro , Terapia por Captura de Nêutron de Boro/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Recidiva Local de Neoplasia , Ombro/patologia , Postura Sentada
5.
J Radiat Res ; 63(4): 620-635, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35726375

RESUMO

The irradiation field of boron neutron capture therapy (BNCT) consists of multiple dose components including thermal, epithermal and fast neutron, and gamma. The objective of this work was to establish a methodology of dosimetric quality assurance (QA), using the most standard and reliable measurement methods, and to determine tolerance level for each QA measurement for a commercially available accelerator-based BNCT system. In order to establish a system of dosimetric QA suitable for BNCT, the following steps were taken. First, standard measurement points based on tissue-administered doses in BNCT for brain tumors were defined, and clinical tolerances of dosimetric QA measurements were derived from the contribution to total tissue relative biological effectiveness factor-weighted dose for each dose component. Next, a QA program was proposed based on TG-142 and TG-198, and confirmed that it could be assessed whether constancy of each dose component was assured within the limits of tolerances or not by measurements of the proposed QA program. Finally, the validity of the BNCT QA program as an evaluation system was confirmed in a demonstration experiment for long-term measurement over 1 year. These results offer an easy, reliable QA method that is clinically applicable with dosimetric validity for the mixed irradiation field of accelerator-based BNCT.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Encefálicas , Terapia por Captura de Nêutron de Boro/métodos , Neoplasias Encefálicas/radioterapia , Raios gama , Humanos , Nêutrons , Radiometria , Eficiência Biológica Relativa
6.
J Radiat Res ; 63(4): 684-695, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35482434

RESUMO

The dosimetric effect of set-up error in boron neutron capture therapy (BNCT) for head and neck cancer remains unclear. In this study, we analyzed the tendency of dose error by treatment location when simulating the set-up error of patients. We also determined the tolerance level of the set-up error in BNCT for head and neck cancer. As a method, the distal direction was shifted with an interval of 2.5 mm, from 0.0 mm to +20.0 mm and compared with the dose at the reference position. Similarly, the horizontal direction and vertical direction were shifted, with an interval of 5.0 mm, from -20.0 mm to +20.0 mm. In addition, cases with 3.0 mm and 5.0 mm simultaneous shifts in all directions were analyzed as the worst-case scenario. The dose metrics of the minimum dose of the tumor and the maximum dose of the mucosa were evaluated. From unidirectional set-up error analysis, in most cases, the set-up errors with dose errors within ±5% were Δdistal < +2.5 mm, Δhorizontal < ±5.0 mm and Δvertical < ±5.0 mm. In the simulation of 3.0 mm shifts in all directions, the errors in the minimum tumor dose and maximum mucosal dose were -3.6% ±1.4% (range, -5.4% to -0.6%) and 2% ±1.4% (range, 0.4% to 4.5%), respectively. From these results, if the set-up error was within ±3.0 mm in each direction, the dose errors of the tumor and mucosa could be suppressed within approximately ±5%, which is suggested as a tolerance level.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço , Terapia por Captura de Nêutron de Boro/métodos , Simulação por Computador , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Radiometria , Dosagem Radioterapêutica
7.
J Appl Clin Med Phys ; 22(11): 90-98, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34599856

RESUMO

PURPOSE: To investigate the dosimetric impact of changes in the large bowel content during proton therapy (PT) with simultaneous integrated boost (SIB) for locally advanced pancreatic cancer (LAPC). MATERIALS AND METHODS: Fifteen patients with LAPC were included in this study. The SIB method was performed using five fields according to our standard protocol. A total dose of 67.5 Gy(relative biological effectiveness [RBE]) was prescribed in 25 fractions using the SIB method. A dose of 45 Gy(RBE) was prescribed for the entire planning target volume (PTV) by using four main fields. The remaining 22.5 Gy(RBE) was prescribed to the PTV excluding for the gastrointestinal tract using one subfield. Five simulated doses were obtained by the forward dose calculations with the Hounsfield units (HU) override to the large bowel to 50, 0, -100, -500, and -1000, respectively. The dose-volume indices in each plan were compared using the 50 HU plan as a reference. RESULTS: At D98 of the clinical target volume (CTV) and spinal cord-D2cc , when the density of the large bowel was close to that of gas, there were significant differences compared to the reference plan (p < 0.05). By contrast, no significant difference was observed in stomach-D2cc duodenum-D2cc , small bowel-D2cc , kidneys-V18 , and liver-Dmean under any of the conditions. There were no cases in which the dose constraint of organs at risk, specified by our institution, was exceeded. CONCLUSION: Density change in the large bowel was revealed to significantly affect the doses of the CTV and spinal cord during PT with SIB for LAPC. For beam arrangement, it is important to select a gantry angle that prevents the large bowel from passing as much as possible. If this is unavoidable, it is important to carefully observe the gas image on the beam path during daily image guidance and to provide adaptive re-planning as needed.


Assuntos
Neoplasias Pancreáticas , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco , Neoplasias Pancreáticas/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
8.
J Radiat Res ; 61(4): 524-534, 2020 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-32367141

RESUMO

The uptake of boron into tumor cells is a key factor in the biological effects of boron neutron capture therapy (BNCT). The uptake of boron agents is suppressed in hypoxic conditions, but the mechanism of hypoxia-induced modulation of suppression of boron uptake is not clear. Therefore, we evaluated whether hypoxia-inducible factor 1α (HIF-1α) contributes to attenuation of the antitumor effects of BNCT in hypoxic tumor cells. We also tested whether YC-1, a HIF-1α-targeting inhibitor, has therapeutic potential with BNCT. To elucidate the mechanism of attenuation of the effects of BNCT caused by hypoxia, deferoxamine (DFO) was used in experiments. Cells were incubated in normal oxygen, hypoxic conditions (1% O2) or 5 µM DFO for 24 h. Then, cells were treated with 10B-boronophenylalanine (BPA) for 2 h and boron accumulation in cells was evaluated. To clarify the relationship between HIF-1α and L-type amino acid transporter 1 (LAT1), gene expression was evaluated by a using HIF-1α gene knockdown technique. Finally, to improve attenuation of the effects of BNCT in hypoxic cells, BNCT was combined with YC-1. Boron uptake was continuously suppressed up to 2 h after administration of BPA by 5 µM DFO treatment. In cells treated with 5 µM DFO, LAT1 expression was restored in HIF-1α-knocked down samples in all cell lines, revealing that HIF-1α suppresses LAT1 expression in hypoxic cells. From the results of the surviving fraction after BNCT combined with YC-1, treatment with YC-1 sensitized the antitumor effects of BNCT in cells cultured in hypoxia.


Assuntos
Antineoplásicos/farmacologia , Terapia por Captura de Nêutron de Boro/métodos , Indazóis/farmacologia , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Radiossensibilizantes/farmacologia , Hipóxia Celular , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Desferroxamina/farmacologia , Humanos , Hipóxia , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Transportador 1 de Aminoácidos Neutros Grandes/metabolismo , Células MCF-7 , Nêutrons , Oxigênio/metabolismo , Fenilalanina/uso terapêutico , RNA Interferente Pequeno/metabolismo
9.
Appl Radiat Isot ; 156: 108961, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31683088

RESUMO

Installation of an accelerator-based boron neutron capture therapy (AB-BNCT) system was started in April 2014 at the Southern Tohoku BNCT Research Center (STBRC), and clinical trials began in January 2016. There are two treatment rooms, which have same specifications, and the beam quality equivalency was confirmed both rooms. Here, we describe the design and construction of the first hospital-based AB-BNCT facility in the world with multiple treatment rooms.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Arquitetura de Instituições de Saúde , Japão , Aceleradores de Partículas
10.
Radiat Prot Dosimetry ; 184(1): 28-35, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30339247

RESUMO

The aim of this work is to optimize an additional collimator in a beam delivery system to reduce neutron exposure to patients in passive carbon-ion therapy. All studies were performed by Monte Carlo simulation assuming the beam delivery system at Heavy-Ion Medical Accelerator in Chiba. We calculated the neutron ambient dose equivalent at patient positions with an additional collimator, and optimized the position, aperture size and material of the collimator to reduce the neutron ambient dose equivalent. The collimator located 125 and 470 cm upstream from the isocenter could reduce the dose equivalent near the isocenter by 35%, while the collimator located 813 cm upstream from the isocenter was ineffective. As for the material of the collimator, iron and nickel could conduct reduction slightly better than aluminum and polymethyl methacrylate. The additional collimator is an effective method for the reduction of the neutron ambient dose equivalent near the isocenter.


Assuntos
Algoritmos , Radioterapia com Íons Pesados/instrumentação , Radioterapia com Íons Pesados/normas , Método de Monte Carlo , Nêutrons , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Humanos , Dosagem Radioterapêutica
11.
Br J Radiol ; : 20180273, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30281327

RESUMO

OBJECTIVE:: Maxillary sinus carcinomas are anatomically situated next to many organs at risk (OARs), and anatomical change is often observed during radiotherapy. We analyzed the effect of anatomical change on dose distribution of passive scattering proton therapy (PSPT) and volumetric-modulated arc therapy (VMAT) for 20 patients. METHODS:: The first plans were generated based on the first CT images. The second CT images were acquired after 3 weeks, and the second plans were generated by copying the first plans to the second CT images. The effect of anatomical change was estimated by comparing both plans. RESULTS:: Target volume change was observed in all cases, however, the influence on dose coverage of clinical target volume tended to be small. Alternatively, the doses to almost all OARs were increased. In particular, the increase in the dose to brainstem (p < 0.001) and optic chiasm (p < 0.001) was significantly higher in the second PSPT plan than in the first PSPT plan. Although PSPT is sensitive to anatomical change, the dose to OARs remained significantly lower in PSPT plans than that in VMAT plans. CONCLUSION:: PSPT was confirmed to be more effective than VMAT even the effect of anatomical change was taken into account. Therefore, it is expected that the contralateral vision can be preserved reliably while optimal target coverage is provided. ADVANCES IN KNOWLEDGE:: PSPT allowed significant sparing of OARs even in the result of the second plans affected by the anatomical change. PSPT offers benefits over VMAT in reducing dose to several OARs.

12.
J Radiat Res ; 59(2): 122-128, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29315429

RESUMO

Boron neutron capture therapy (BNCT) can potentially deliver high linear energy transfer particles to tumor cells without causing severe damage to surrounding normal tissue, and may thus be beneficial for cases with characteristics of infiltrative growth, which need a wider irradiation field, such as glioblastoma multiforme. Hypoxia is an important factor contributing to resistance to anticancer therapies such as radiotherapy and chemotherapy. In this study, we investigated the impact of oxygen status on 10B uptake in glioblastoma cells in vitro in order to evaluate the potential impact of local hypoxia on BNCT. T98G and A172 glioblastoma cells were used in the present study, and we examined the influence of oxygen concentration on cell viability, mRNA expression of L-amino acid transporter 1 (LAT1), and the uptake amount of 10B-BPA. T98G and A172 glioblastoma cells became quiescent after 72 h under 1% hypoxia but remained viable. Uptake of 10B-BPA, which is one of the agents for BNCT in clinical use, decreased linearly as oxygen levels were reduced from 20% through to 10%, 3% and 1%. Hypoxia with <10% O2 significantly decreased mRNA expression of LAT1 in both cell lines, indicating that reduced uptake of 10B-BPA in glioblastoma in hypoxic conditions may be due to reduced expression of this important transporter protein. Hypoxia inhibits 10B-BPA uptake in glioblastoma cells in a linear fashion, meaning that approaches to overcoming local tumor hypoxia may be an effective method of improving the success of BNCT treatment.


Assuntos
Compostos de Boro/uso terapêutico , Terapia por Captura de Nêutron de Boro , Glioblastoma/radioterapia , Oxigênio/metabolismo , Fenilalanina/análogos & derivados , Proteínas Adaptadoras de Transdução de Sinal/genética , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Hipóxia Celular/efeitos da radiação , Linhagem Celular Tumoral , Proliferação de Células/efeitos da radiação , Sobrevivência Celular/efeitos da radiação , Regulação Neoplásica da Expressão Gênica , Glioblastoma/genética , Glioblastoma/patologia , Humanos , Transportador 1 de Aminoácidos Neutros Grandes/genética , Transportador 1 de Aminoácidos Neutros Grandes/metabolismo , Fenilalanina/uso terapêutico , RNA Mensageiro/genética , RNA Mensageiro/metabolismo