Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Biomech (Bristol, Avon) ; 103: 105925, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36863219

RESUMO

INTRODUCTION: Despite good screw anchorage and safe screw trajectory, screw loosening occurs in several cases, especially in osteoporotic individuals. The aim of this biomechanical analysis was to evaluate the primary stability of revision screw placement in individuals with reduced bone quality. Therefore, revision via enlarged diameter screws was compared to the use of human bone matrix as augmentation to improve the bone stock and screw coverage. METHODS: 11 lumbar vertebral bodies from cadaveric specimens with a mean age of 85.7 years (± 12.0 years) at death were used. 6.5 mm diameter pedicle screws were inserted in both pedicles and hereafter loosened using a fatigue protocol. Screws were revised inserting a larger diameter screw (8.5 mm) in one pedicle and a same diameter screw with human bone matrix augmentation in the other pedicle. The previous loosening protocol was then reapplied, comparing maximum load and cycles to failure between both revision techniques. Insertional torque was continuously measured during insertion of both revision screws. FINDINGS: The number of cycles and the maximum load until failure were significantly greater in enlarged diameter screws than in augmented screws. The enlarged screws' insertional torque was also significantly higher than of the augmented screws. INTERPRETATION: Human bone matrix augmentation does not reach the same ad-hoc fixation strength as enlarging the screw's diameter by 2 mm and is therefore biomechanically inferior. Regarding the immediate stability, a thicker screw should therefore be prioritised.


Assuntos
Osteoporose , Parafusos Pediculares , Humanos , Idoso de 80 Anos ou mais , Matriz Óssea , Osso e Ossos , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Fenômenos Biomecânicos , Cimentos Ósseos , Cadáver
2.
Eur Spine J ; 32(4): 1455-1462, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36826598

RESUMO

OBJECTIVE: Pyogenic spondylodiscitis is a severe medical condition, often requiring surgical intervention. Numerous risk factors are known, such as obesity, neurological impairment and old age. In-hospital mortality remains high, therefore other factors may be contributing to the increased mortality. To evaluate kidney function as a risk factor for increased morbidity of pyogenic spondylodiscitis, the glomerular filtration rate (GFR) was correlated with the patients' clinical course. MATERIALS AND METHODS: We retrospectively reviewed the cases of 366 patients and 255 were included for analysis. Clinical, laboratory and surgical data were recorded with a minimum follow-up of three months. For clinical outcome measurement, mortality, length of stay and perioperative complications were analysed. RESULTS: The study included 255 patients (173 men, 82 women; mean age 66.3 years). Patients with a GFR < 59 mL/min spent an average of 5 days longer in the hospital than those with a GFR ≥ 60 mL/min (p = 0.071). The mortality rate increased significantly with a decrease in GFR: A GFR of 30-59 mL/min had a mortality rate of 17.6%, whereas a GFR of < 29 mL/min had one of 30.4% (p = 0.003). Patients with impaired GFR showed an increased rate of postoperative complications (OR 4.7 p = 0.002) and higher rate of intensive care unit (ICU) stay (OR 8.7 p = < 0.001). DISCUSSION: Preoperative GFR values showed a significant correlation with in-hospital mortality in patients with spondylodiscitis, when graded according to the KDIGO stages. Furthermore, a GFR of < 29 ml/mL contributes to a longer ICU stay, postoperative complications and a longer total hospital stay. Therefore, the preoperative GFR could be a marker of kidney function and as a valuable predictive risk factor regarding the clinical in-hospital course of patients suffering from pyogenic spondylodiscitis.


Assuntos
Discite , Masculino , Humanos , Feminino , Idoso , Discite/cirurgia , Taxa de Filtração Glomerular , Estudos Retrospectivos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Rim
3.
J Orthop ; 37: 1-4, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36718421

RESUMO

Study design: prospective, observational. Background: Wound drainage's indwelling duration and general use are the centre of ongoing discussion. The aim of our prospective observational study was to evaluate the total drainage volume postoperatively and its course after lumbar interbody fusion surgeries to define an ideal point in time for drainage removal. Methods: We included all patients who underwent monosegmental lumbar interbody fusion via transforaminal or posterior lumbar interbody fusion (TLIF/PLIF). After application of the exclusion criteria, 27 patients were included in our study. Drainage volume was measured three times a day and at the time of drain removal. Results: The PLIF group reached higher total drainage volume (337.14 ml) than the TLIF group (215.5 ml) (p = 0.047. Drainage volume's plateau was reached after 33.0 h (±1.8 h) in the TLIF group and 25.3 h (±1.7 h) in the PLIF group following surgery. Conclusions: Our study shows, that drainage volume did not increase significantly after the evening of the first postoperative day at latest. This was on average 33.0 h after surgery. Therefore, extraction of the drainage tube hereafter can be assumed to be safe.

4.
Arch Orthop Trauma Surg ; 143(2): 857-863, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35064826

RESUMO

BACKGROUND: Lateral collateral ligament (LCL) tears are frequently observed in fractures and dislocations of the elbow. Recent biomechanical evidence suggests that additional ligament augmentation may improve repair stability. The aim of this biomechanical in-vitro study was to compare the resistance of a locking suture repair of the LCL with a ligament augmentation technique. MATERIAL AND METHODS: Eight fresh frozen cadaveric elbows were evaluated for stability against varus/posterolateral rotatory forces (3 Nm). A strain gauge (µm/m; negative values) was placed at the origin and insertion of the lateral ulnar collateral ligament (LUCL) and cyclic loading was performed for 1000 cycles. We analyzed three distinct scenarios: (A) native LCL, (B) locking transosseou suture repair of the LCL, (C) simple LCL repair with additional ligament augmentation of the LUCL. RESULTS: The mean measured strain was - 416.1 µm/m (A), - 618 µm/m (B) and - 288.5 µm/m (C) with the elbow flexion at 90°; the strain was significantly higher in scenario B compared to C (p = .01). During the cyclic load (1000) the mean measured strain was - 523.1 µm/m (B) and - 226.3 µm/m (C) with the elbow flexion at 60°; the strain was significantly higher in scenario B compared to C (p = .01). No significant difference between the first and the last cycles was observed (p = .09; p = .07). One failure of the LCL repair was observed after 1000 cycles; none of the ligament augmentations failed. CONCLUSION: Ligament augmentation (C) provides higher resistance compared to the native LCL (A) and to the locking suture repair technique (B). Both techniques, however, hold up during 1000 cycles. While ligament augmentation might enhance the primary stability of the repair, future clinical studies have to show whether this increase in resistance leads to negative effects like higher rates of posttraumatic elbow stiffness. LEVEL OF EVIDENCE: Basic science study, biomechanics.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Cotovelo , Instabilidade Articular/cirurgia , Articulação do Cotovelo/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Cadáver , Suturas , Ligamentos Colaterais/cirurgia , Ligamentos Colaterais/lesões
5.
Eur Spine J ; 30(12): 3614-3619, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34559274

RESUMO

OBJECTIVE: For surgical treatment of instable upper cervical injuries, the Harms technique using lateral mass screws provides rigid fixation and favourable clinical outcomes. The use of the posterior arch of C1 as a "pedicle" allows for screw anchorage, giving improved biomechanical stability. Therefore, the aim of this study was to introduce a bilateral safe zone for C1 pedicle screws, regarding screw angulation and pedicle height. MATERIAL AND METHODS: We retrospectively reviewed the CT scans of 500 patients. Three-dimensional reformats were generated for detailed measurements. Centre screw entry point (EP), length of lateral mass as screw trajectory, lateral mass width (LMW), length of screw trajectory (ST), maximal divergence (DI) and maximal convergence (CON) from EP without perforation, and pedicle height (PH) of the posterior arch were measured. RESULTS: The 500 cases consisted of 335 males and 165 females, with a mean age of 49.5 years. Measurements did not demonstrate significant side-related differences. The mean screw entry point was 22.8 mm from the midline-axis (left 22.6 mm; right 23.0 mm). From this point, a safe zone between 11.6° of divergence and 19.6° of convergence was detected. Measurements of female patients were generally smaller, with significant differences from male patients (p < 0.05). 158 subjects (31.6%) had a PH < 4 mm. DISCUSSION: C1 pedicle screws were feasible in the majority of patients. Proposing a safe zone for screw angulation may provide safety and avoid screw perforation. However, detailed knowledge of the individual C1 anatomy and the preoperative measurement is essential in the operative planning.


Assuntos
Articulação Atlantoaxial , Parafusos Pediculares , Fusão Vertebral , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Tomografia Computadorizada por Raios X
6.
Clin Biomech (Bristol, Avon) ; 89: 105478, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34517193

RESUMO

BACKGROUND: The brachialis muscle lies in close anatomic relation to the anterior capsule of the elbow joint. The contribution of the brachialis muscle to elbow stability has not yet been fully investigated. Therefore, the aim of this biomechanical in-vitro study was to analyze its influence on joint stability. METHODS: Nine fresh frozen cadaveric elbows were evaluated for stability against valgus and varus/posterolateral rotatory forces. Brachialis loading was measured indirectly using strain gauges. Three distinct scenarios were analyzed: A) with intact lateral ulnar and ulnar collateral ligaments B) with a ruptured lateral ulnar collateral ligament C) with ruptured lateral ulnar and ulnar collateral ligaments. FINDINGS: In all scenarios, an increased strain was observed under posterolateral rotatory/varus forces. The maximum measured strain occurred with elbow flexion of 30° and pronation of the forearm. The strain was significantly higher with dual-ligament rupture (mean - 210.5 µm/m; min. 97.8 µm/m; max. -310 µm/m; SD 107.8 µm/m; p = .034) compared to intact ligaments (mean - 106.9 µm/m; min. -32.51 µm/m, max. -287 µm/m; SD 100.2 µm/m) and single-ligament rupture (mean - 109.5 µm/m; min. - 96.7 µm/m; max - 130.4 µm/m; SD 18.2). INTERPRETATION: A strain of the brachialis muscle was observed under varus/posterolateral rotatory forces with a pronated forearm and the strain increased significantly in the event of a dual-ligament rupture. This suggests that the brachialis muscle may influence varus/posterolateral rotatory stability of the elbow. Hence, a concomitant tear of the brachialis muscle might result in pronounced instability following simple elbow dislocation. LEVEL OF EVIDENCE: Basic Science Study, Biomechanics.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Instabilidade Articular , Fenômenos Biomecânicos , Cadáver , Cotovelo , Humanos , Músculo Esquelético
7.
Eur Spine J ; 30(7): 1813-1822, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33772381

RESUMO

INTRODUCTION: Idiopathic scoliosis, defined as a > 10° curvature of the spine in the frontal plane, is one of the most common spinal deformities. Age, initial curve magnitude and other parameters define whether a scoliotic deformity will progress or not. Still, their interactions and amounts of individual contribution are not fully elaborated and were the aim of this systematic review. METHODS: A systematic literature search was conducted in the common databases using MESH terms, searching for predictive factors of curve progression in adolescent idiopathic scoliosis ("adolescent idiopathic scoliosis" OR "ais" OR "idiopathic scoliosis") AND ("predictive factors" OR "progression" OR "curve progression" OR "prediction" OR "prognosis"). The identified and analysed factors of each study were rated to design a top five scale of the most relevant factors. RESULTS: Twenty-eight investigations with 8255 patients were identified by literature search. Patient-specific risk factors for curve progression from initial curve were age (at diagnosis < 13 years), family history, bone mineral status (< 110 mg/cm3 in quantitative CT) and height velocity (7-8 cm/year, peak 11.6 ± 1.4 years). Relevant radiological criteria indicating curve progression included skeletal maturity, marked by Risser stages (Risser < 1) or Sanders Maturity Scale (SMS < 5), the initial extent of the Cobb angle (> 25° progression) and curve location (thoracic single or double curve). DISCUSSION: This systematic review summarised the current state of knowledge as the basis for creation of patient-specific algorithms regarding a risk calculation for a progressive scoliotic deformity. Curve magnitude is the most relevant predictive factor, followed by status of skeletal maturity and curve location.


Assuntos
Escoliose , Adolescente , Progressão da Doença , Humanos , Prognóstico , Radiografia , Estudos Retrospectivos , Escoliose/diagnóstico por imagem , Coluna Vertebral
8.
J Shoulder Elbow Surg ; 30(9): 2184-2190, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33581277

RESUMO

BACKGROUND: The incidence of periprosthetic fractures of the proximal humerus is gradually increasing, following an increase in reverse shoulder arthroplasties in recent years. Locking plate fixation and revision arthroplasty are both valuable treatment methods. However, the primary stability of fixation methods for periprosthetic fractures has not been investigated in detail. The aim of this study was to analyze and compare the primary stability of the common treatment measures. MATERIALS AND METHODS: Cemented reverse total shoulder arthroplasty (Delta Xtend; DePuy Synthes, Warsaw, IN, USA) was performed in 5 shoulders, and a distal, mid-diaphysis humeral fracture (Wright and Cofield type B) was induced. The implant was left in place, and 3 distinct fixation scenarios were tested: osteosynthesis using 4.5-mm locking plate fixation (subgroup A), 4.5-mm locking plate fixation with an additional 3.5-mm locking plate (subgroup B), and 4.5-mm locking plate fixation with an additional K-wire cerclage (subgroup C). The specimens were tested in a biomechanical setup simulating activities of daily living including rotation. Strain gauges (4-wire strain at 120 Ω; Vishay Measurements Group, Chartres, France) mounted on the 4.5-mm locking plates were used to evaluate the strain of the fixation and to give an estimate of primary stability. RESULTS: Regarding the simulation of activities of daily living, no statistically significant differences were found in the measured strains on the locking plate between subgroups A, B, and C. A maximum measured strain of 216.85 µm/m in subgroup A resulted in bending of the locking plate (length, 134 mm) of 0.03 mm. In subgroup B (277.01 µm/m), the plate strained 0.04 mm compared with a strain measurement of 0.01 mm in subgroup C (75.93 µm/m). CONCLUSION: Additional K-wire cerclages or additional 3.5-mm locked plating did not increase primary stability. With a stable prosthetic implant in place, 4.5-mm locked plating is sufficient to address periprosthetic humeral shaft fractures in the present in vitro setup.


Assuntos
Fraturas Periprotéticas , Atividades Cotidianas , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas , Humanos , Úmero , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...