Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Dent J (Basel) ; 12(6)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38920861

RESUMO

Modern conservative dentistry is taking the lead in daily clinical practice and is relying on adhesion. Whether it is a simple composite, ceramic inlays, onlays, veneers or crowns, the common factor for a successful outcome is a good bonding of these elements to dental structures. Thus, the purpose of this study was to evaluate the bond strength of resin composite to dentin when using a new device, the DENTIPURE KM™ (KM, Beirut, Lebanon), which provides a pure air flow, free of any contaminants and without humidity, when compared to other dental equipment. One hundred and eighty extracted human molars were equally divided into three groups according to the device used, the DENTIPURE KM™ (KM, Beirut, Lebanon), the KAVO™ (ESTETICA E30/E70/E80 Vision, KAVO, Biberach, Germany), or the ADEC™ (A-dec Performer 200, Newberg, OR, USA). The shear bond strength (SBS) was evaluated after 24 h of storage in distilled water on a universal testing machine. Statistical analysis was set with a level of significance at p ≤ 0.05. The results revealed that significantly different bond strength was imparted by the DENTIPURE KM™ device and the ADEC™ dental unit (p = 0.042). In conclusion, while the DENTIPURE KM™ device shows promise in providing contaminant-free air during bonding, its impact on dentin bond strength compared to devices like the KAVO™ appears minimal. Further research is needed to fully assess its potential in enhancing dentinal adhesion procedures.

2.
Polymers (Basel) ; 15(19)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37835974

RESUMO

One of the major goals of adhesive dentistry is to improve the interaction of the already-existing adhesives with different substrates by using different application techniques. Thus, the objective of the present in vitro study was to assess the bond performance of four adhesive systems, Prime&Bond Universal (PBU), Clearfil SE Bond (CSE), OptiBond Universal (OBU), and OptiBond FL (OBFL), to dentin using various application modes: passive application (PA), active application (AA), Compo-Vibes modified application (CVM), and Compo-Vibes application (CV). Eighty extracted human molars were allocated into four groups based on the application modalities tested. The micro-tensile bond strength as well as fracture mode were tested in accordance with ISO/TS 11.405 after 24 h and 6 months of aging. Adhesive contact angle (CA) and scanning electron microscope analysis were also performed (n = 3). Statistical tests were performed with α = 0.05. After 24 h, a significant difference with a higher bond strength value was found for PBU in the AA modality and for CSE in the CVM modality (p < 0.05). However, no significant difference was shown between the techniques used among the other adhesives (OBFL and OBU). Moreover, at 24 h, only the PA demonstrated significant differences between the tested materials (p < 0.05). After 6 months, CSE, PBU, and OBU demonstrated significant differences between the techniques (p < 0.05), with a higher bond strength for CSE in AA and CVM modalities, for PBU in AA modality, and for OBU in AA and PA modalities. No significant differences were found between the techniques used among the OBFL (p > 0.05). In addition, only the CVM technique demonstrated significant differences between the tested materials after 6 months. CV and CVM showed a decreased value after aging for CSE and PBU, respectively. However, all the modalities decreased for OBU and OBFL after aging. All the adhesives showed marked resin infiltration into dentinal tubules in AA among all the modalities tested. Both universal adhesive systems (OBU and PBU) demonstrated statistically lower CA when compared to the other systems (CSE and OBFL) (p < 0.05) when applied in the PA mode. Concerning the AA mode, only CSE and OBFL were tested. The AA demonstrated lower CA values compared to the same adhesives in PA (p < 0.05). It could be concluded that the bond strength could be influenced by both materials and application techniques. It seems that the AA technique could be recommended as a gold standard for the application of an adhesive system to dentin. Plus, the CV and CVM modalities after 6 months of aging were considered stable for PBU and CSE, respectively. Consequently, the performance of these adhesive systems might vary when applied to other modalities. Future studies are needed to test this hypothesis.

3.
Bioengineering (Basel) ; 9(7)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35877337

RESUMO

The salivary contamination occurring at the try-in procedures of lithium disilicate (LDS) can jeopardize their bond strength. Various laboratory reports have concluded that applying 37% phosphoric acid (H3PO4) could be considered as a predictable way of removing salivary contaminants. An experimental method that consists of sealing the intaglio of the ceramic restorations with a layer of cured adhesive could allow consequent time saving for dental practitioners. It is, besides, necessary to establish an optimal decontamination protocol. Hence, this study aimed to determine the most efficient surface treatment, before and after salivary contamination, by comparing the adhesion between resin and LDS. In order to do so, five groups of ten specimens (n = 10) each underwent the different types of surface treatments before bonding, followed by 2500 cycles in the thermocycler. A shear bond strength (SBS) test was then conducted on a universal testing machine (YLE GmbH Waldstraße Bad König, Germany), followed by a fracture-type analysis on an optical microscope (Olympus BX53, Shinjuku, Tokyo, Japan). Statistical analysis was set with a level of significance of α = 0.05. The surface treatment significantly affected the SBS results. The decontamination with HF (12.59 ± 2.71 MPa) and H3PO4 (13.11 ± 1.03 MPa) obtained the highest values, silanizing only before contamination obtained intermediate values (11.74 ± 3.49 MPa), and silanizing both before and after the salivary contamination (10.41 ± 2.75 MPa) along with applying a bonding agent before contamination (9.65 ± 1.99 MPa) resulted in the lowest values. In conclusion, H3PO4 proved to be efficient, thus, allowing the practitioner to avoid the clinical use of HF; it can, therefore, be considered as a valid alternative. Presilanization and resilanization of specimens, along with applying a bonding agent before contamination, did not yield satisfying results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA