Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Open ; 10(10): e038045, 2020 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-33020097

RESUMO

OBJECTIVES: Robotic-assisted laparoscopic prostatectomy (RALP) is typically conducted in steep Trendelenburg position (STP). This study investigated the influence of permanent 45° STP and capnoperitoneum on haemodynamic parameters during and after RALP. DESIGN: Prospective observational study. SETTING: Haemodynamic changes were recorded with transpulmonary thermodilution and pulse contour analysis in men undergoing RALP under standardised anaesthesia. PARTICIPANTS: Informed consent was obtained from 51 patients scheduled for elective RALP in a University Medical Centre in Germany. INTERVENTIONS: Heart rate, mean arterial pressure, central venous pressure (CVP), Cardiac Index (CI), systemic vascular resistance (SVR), Global End-Diastolic Volume Index (GEDI), global ejection fraction (GEF), Cardiac Power Index (CPI) and stroke volume variation (SVV) were recorded at six time points: 20 min after induction of anaesthesia (T1), after insufflation of capnoperitoneum in supine position (T2), after 30 min in STP (T3), when controlling Santorini's plexus in STP (T4), before awakening in supine position (T5) and after 45 min in the recovery room (T6). Adverse cardiac events were registered intraoperatively and postoperatively. RESULTS: All haemodynamic parameters were significantly changed by capnoperitoneum and STP during RALP and partly normalised at T6. CI, GEF and CPI were highest at T6 (CI: 3.9 vs 2.2 L/min/m²; GEF: 26 vs 22%; CPI: 0.80 vs 0.39 W/m²; p<0.001). CVP was highest at T4 (31 vs 7 mm Hg, p<0.001) and GEDI at T6 (819 vs 724 mL/m², p=0.005). Mean SVR initially increased (T2) but had decreased by 24% at T6 (p<0.001). SVV was highest at T5 (12 vs 9%, p<0.001). Two of the patients developed cardiac arrhythmia during RALP and one patient suffered postoperative cardiac ischaemia. CONCLUSIONS: RALP led to pronounced perioperative haemodynamic changes. The combination of increased cardiac contractility and heart rate reflects a hyperdynamic situation during and after RALP. Anaesthesiologists should be aware of unnoticed pre-existing heart failure to worsen during STP in patients undergoing RALP.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Alemanha , Hemodinâmica , Humanos , Masculino , Prostatectomia , Procedimentos Cirúrgicos Robóticos/efeitos adversos
2.
J Clin Monit Comput ; 33(1): 133-143, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29663179

RESUMO

Obesity affects respiratory and hemodynamic function in anesthetized patients. The aim of this study was to evaluate the influence of the body mass index (BMI) on pulmonary changes in a permanent 45° steep Trendelenburg position (STP) during robotic-assisted laparoscopic prostatectomy (RALP). 51 patients undergoing RALP under standardized anesthesia were included. Perioperative pulmonary function and oxygenation were measured in awake patients (T0), 20 min after the induction of anesthesia (T1), after insufflation of the abdomen in supine position (T2), after 30 min in STP (T3), when controlling Santorini's plexus in STP (T4), before awakening while supine (T5), and after 45 min in the recovery room (T6). Patient-specific and time-dependent factor on ventilation and predicted peak inspiratory pressure (PIP), driving pressure (Pdriv) and lung compliance (LC) in a linear regression model were calculated. PIP and Pdriv increased significantly after induction of capnoperitoneum (T2-4) (p < 0.0001). In univariate mixed effects models, BMI was found to be a significant predictor for PIP and Pdriv increase and LC decrease. Obese patients a BMI > 31 kg/m2 reached critical PIP values ≥ 35 cmH2O. Postoperative oxygenation represented by the PaO2/FiO2 ratio was significantly decreased compared to T0 (p < 0.0001). Obesity in combination with STP and capnoperitoneum during RALP has a profound effect on pulmonary function. Increased PIP and Pdriv and decreased LC are directly correlated with a high BMI. Changes in PIP, Pdriv and LC during RALP may be predicted in relation to patient's BMI for consideration in the preoperative setting. Trial registration number Z-2014-0387-6. Registered on 8 July 2014.


Assuntos
Laparoscopia/efeitos adversos , Obesidade/complicações , Prostatectomia/efeitos adversos , Neoplasias da Próstata/complicações , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Idoso , Anestesia , Anestesiologia/métodos , Índice de Massa Corporal , Decúbito Inclinado com Rebaixamento da Cabeça , Hemodinâmica , Humanos , Modelos Lineares , Complacência Pulmonar , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Período Pós-Operatório , Estudos Prospectivos , Testes de Função Respiratória , Mecânica Respiratória , Risco
3.
BMC Anesthesiol ; 17(1): 40, 2017 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-28284189

RESUMO

BACKGROUND: To evaluate changes in intraocular pressure (IOP) and intracerebral pressure (ICP) reflected by the optic nerve sheath diameter (ONSD) in patients undergoing robotic-assisted laparoscopic prostatectomy (RALP) in permanent 45° steep Trendelenburg position (STP). METHODS: Fifty-one patients undergoing RALP under a standardised anaesthesia. IOP was perioperatively measured in awake patients (T0) and IOP and ONSD 20 min after induction of anaesthesia (T1), after insufflation of the abdomen in supine position (T2), after 30 min in STP (T3), when controlling Santorini's plexus in STP (T4) and before awakening while supine (T5). We investigated the influence of respiratory and circulatory parameters as well as patient-specific and time-dependent factors on IOP and ONSD. RESULTS: Average IOP values (mmHg) were T0 = 19.9, T1 = 15.9, T2 = 20.1, T3 = 30.7, T4 = 33.9 and T5 = 21.8. IOP was 14.0 ± 7.47 mmHg (mean ± SD) higher at T4 than T0 (p = 0.013). Univariate mixed effects models showed peak inspiratory pressure (PIP) and mean arterial blood pressure (MAP) to be significant predictors for IOP increase. Mean ONSD values (mm) were T1 = 5.88, T2 = 6.08, T3 = 6.07, T4 = 6.04 and T5 = 5.96. The ONSD remained permanently >6.0 mm during RALP. Patients aged <63 years showed a 0.21 mm wider ONSD on average (p = 0.017) and greater variations in diameter than older patients. CONCLUSIONS: The combination of STP and capnoperitoneum during RALP has a pronounced influence on IOP and, to a lesser degree, on ICP. IOP is directly correlated with increasing PIP and MAP. IOP doubled and the ONSD rose to values indicating increased intracranial pressure. Differences in the ONSD were age-related, showing higher output values as well as better autoregulation and compliance in STP for patients aged <63 years. Despite several ocular changes during RALP, visual function was not significantly impaired postoperatively. TRIAL REGISTRATION: Z-2014-0387-6 . Registered 8 July 2014.


Assuntos
Decúbito Inclinado com Rebaixamento da Cabeça , Pressão Intraocular/fisiologia , Laparoscopia , Nervo Óptico/diagnóstico por imagem , Prostatectomia , Procedimentos Cirúrgicos Robóticos , Fatores Etários , Idoso , Pressão Sanguínea/fisiologia , Humanos , Inalação/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tonometria Ocular , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...