Anal Bioanal Chem ; 400(8): 2323-7, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21547432

RESUMO

Protein precipitation was incorporated into a sample preparation method for the quantitative determination of small "non-protein" selenium species in human serum by high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC/ICPMS). The advantages of cleaner matrix and concomitant concentration of the small compounds result in quantification limits in the native serum at the sub-micrograms Se per litre level. Spiking experiments with methyl 2-acetamido-2-deoxy-1-seleno-ß-D-galactopyranoside (selenosugar 1), trimethylselenonium ion, selenomethionine, methylselenocysteine (MeSeCys) and selenate yielded recoveries from 73% to 103%. Selenite had a low recovery (44%), possibly owing to protein binding. The validated method was applied to serum samples from two volunteers before and after ingestion of a selenium food supplement. HPLC/ICPMS analysis showed, besides ingested selenate, the presence of selenosugar 1 and trace amounts of MeSeCys and methyl 2-amino-2-deoxy-1-seleno-ß-D-galactopyranoside, which have not been reported in human serum before.


Assuntos
Compostos Organosselênicos/sangue , Adulto , Cromatografia Líquida de Alta Pressão , Suplementos Nutricionais , Feminino , Humanos , Masculino , Proteínas/isolamento & purificação , Selênio/administração & dosagem , Selênio/sangue , Espectrometria de Massas por Ionização por Electrospray