Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Orthopade ; 50(4): 326-332, 2021 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-32350550

RESUMO

A Thymic carcinoma in adults is rare. We present the case of a 47-year-old man, who was treated conservatively for spondylolisthesis L5/S1 in our institution for several years. In the further course, the patient complained about pain exacerbation with acute lower back pain. Cross-sectional scanning showed a tumor of the lumbar vertebral body three. A biopsy of this mass revealed a metastatic thymic carcinoma of the squamous cells. After palliative therapy, the patient died 9 months after initial diagnosis.


Assuntos
Fusão Vertebral , Espondilolistese , Timoma , Neoplasias do Timo , Adulto , Estudos Transversais , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Timoma/diagnóstico por imagem , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/terapia
2.
Z Orthop Ihre Grenzgeb ; 141(6): 705-11, 2003.
Artigo em Alemão | MEDLINE | ID: mdl-14679438

RESUMO

AIM: Aim of this study was to determine whether coating of titanium implants of various surfaces with BMP-3 would improve the osseous integration of the implants into the orthotopic bony implant bed. METHOD: In this experimental study 190 micro g per implant of highly purified bone morphogenetic protein 3 (BMP-3) precipitate isolated from porcine bone were available for the coating of each of 24 cylindrical test implants (12 with hydroxyapatite and 12 with plasmapore surface). The remaining 24 test implants with the same surface makeup served as negative controls. Implantation sites were randomly assigned for the 4 versions of implants available and all implants were embedded into the medial or lateral femoral condyle of both legs of 12 German shepherds. The drilling holes were performed in such a matter that after embedding the cylindrical devices a gap of 1 mm surrounding the implants remained. A biomechanical testing and histological evaluation was performed on the explants 42 days after surgery. RESULTS: In biomechanical testing forces necessary to extract the implants from the explanted bones in BMP-3 coated devices were up to 70% higher compared to the ones in the non-coated reference groups. Quantitative histomorphometric examination showed in BMP-3-coated implants an increasing formation of new bone close to their own surface (gap-healing) which was higher than in the corresponding non-coated controls (hydroxyapatite + BMP-3 32.1%, hydroxyapatite controls 20.3%, plasmapore + BMP-3 30.2%, plasmapore controls 13.1%). The extent of direct bone implant contact as percentiles of the corresponding implants perimeter (ongrowth) was also significantly higher in the BMP-3-coated implants compared to the non-coated controls (hydroxyapatite + BMP-3 37.7%, hydroxyapatite controls 22.4%, plasmapore + BMP-3 15.3%, plasmapore controls 6.4%). CONCLUSION: In this study it was proven the first time that implants of various surface textures as used in endoprosthetics are able to be coated by the osteoinductive growth factor BMP-3. In that way metallic implants can achieve osteogenic properties which have positive effects in osseointegration.


Assuntos
Proteínas Morfogenéticas Ósseas/farmacologia , Materiais Revestidos Biocompatíveis , Prótese Articular , Osseointegração/efeitos dos fármacos , Titânio , Fator de Crescimento Transformador beta , Ligas , Animais , Artroplastia do Joelho , Fenômenos Biomecânicos , Proteína Morfogenética Óssea 2 , Cães , Durapatita , Articulação do Joelho/patologia , Prótese do Joelho , Teste de Materiais , Desenho de Prótese , Propriedades de Superfície , Suínos , Resistência à Tração
3.
Biomed Tech (Berl) ; 48(7-8): 217-24, 2003.
Artigo em Alemão | MEDLINE | ID: mdl-12910863

RESUMO

AIM: To establish whether the additional coating of titanium implants with Bone Morphogenetic Protein-3 (BMP-3) might enhance osseous integration. METHOD: Each of 15 cylindrical titanium test implants (Ti-6AI-4V) was coated using 230 micrograms porcine BMP-3. A further 15 implants with identical (corundium-blasted) surface served as negative controls. An uncoated and a BMP-3-coated test object were implanted into the femurs of 15 adult giant rabbits. New formation of bone around the implants was examined microscopically and histomorphometrically on postoperative days 14, 35 and 56. RESULTS: Coated implants revealed superior osseointegration with statistical evaluation using the t-test for matched samples showing a significantly higher volume of new bone 5 weeks after surgery. Microscopic examination revealed osseointegration with no connective tissue membrane around the surface of the implants. CONCLUSIONS: Our results indicate that composite metal implants are suitable carriers for BMP-3 and that improved fixation of the implants can be achieved.


Assuntos
Proteínas Morfogenéticas Ósseas , Materiais Revestidos Biocompatíveis , Prótese Articular , Osseointegração/fisiologia , Titânio , Ligas , Animais , Proteína Morfogenética Óssea 3 , Proteínas Morfogenéticas Ósseas/farmacologia , Fêmur/patologia , Fêmur/cirurgia , Microscopia Eletrônica de Varredura , Osseointegração/efeitos dos fármacos , Coelhos , Propriedades de Superfície
4.
Chirurg ; 72(11): 1360-8, 2001 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-11766662

RESUMO

INTRODUCTION: The successful combination of osteoinductive factors with current materials used in both endoprosthetics and implantology improves bony ingrowth and long-term stability of the chosen implants. The aim of the present experimental animal study was to clarify in what way faster bony integration can be achieved through additional BMP-3-coating of titanium test implants of different surface textures (hydroxy-apatite-coated or corundum-blasted). METHODS: Thirty of 60 cylindrical titanium test implants with a hydroxy-apatite or corundum-blasted surface were coated with 230 microg porcine, high-purified BMP-3-precipitate per implant to check their osteoinductive potential in a bioassay. In each case a BMP-3-coated and an uncoated control-device were implanted with a gap formation of 1 mm into the femoral part of the patellofemoral joint of the right and left leg of 30 adult giant rabbits. Serial saw slices of all explanted specimens were prepared, and the osseous integration of the implant and time-dependent bone neoformation were analyzed microscopically and histomorphometrically 14, 35, and 56 days after implantation. RESULTS: Coating of TiAl4V6-test devices with BMP-3 led in both groups after gap implantation to an improved osseointegration, that was histomorphological and histomorphometrical verifiable. Statistical evaluation using the t-test for matched samples showed 5 weeks after surgery a significant higher volume of new formed bone of the BMP-3-coated corundum-blasted or hydroxy-apatite-coated TiAl4V6 test devices compared to the non-coated controls of the same type (P < 0.01). Light microscopy demonstrated osseointegration without connective tissue membrane around the surface of the implants after 2, 5, and 8 weeks. Better osseointegration was achieved in the hydroxy-apatite-coated implants than in the corundum-blasted implants. CONCLUSIONS: Our results indicate that composite metal implants, as used in endoprosthetics and implantology, are suitable carriers for BMP-3 and improved fixation of the implants can be achieved.


Assuntos
Proteínas Morfogenéticas Ósseas/farmacologia , Materiais Revestidos Biocompatíveis , Osseointegração/efeitos dos fármacos , Próteses e Implantes , Titânio , Ligas , Animais , Proteína Morfogenética Óssea 3 , Fêmur/patologia , Fêmur/cirurgia , Coelhos , Propriedades de Superfície , Suínos
7.
Acta Orthop Scand ; 67(6): 606-10, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9065076

RESUMO

Disc-shaped implants of titanium alloy (Ti-6Al-4V) were treated on one side by corundum-blasting (CB) or by coating with hydroxyapatite (HA) or pure titanium (Ti) using plasma spraying. Half of the implants were additionally coated with purified swine BMP-3. The composites and the uncoated controls were implanted into abdominal wall-muscle pouches of rats. 25 days after implantation, ectopic bone formation could be observed macroscopically and histologically in a high frequency in all 3 groups of BMP-coated implants, whereas the controls were constantly inactive. The volumes of induced bone were similar for BMP-3-coated pure Ti and HA implants, while CB implants were significantly less active. Our findings indicate that the bone formation process is influenced by the chemical composition and by the structure of the implant surface.


Assuntos
Proteínas Morfogenéticas Ósseas/farmacologia , Osteogênese/efeitos dos fármacos , Titânio/farmacologia , Ligas , Animais , Osso e Ossos/ultraestrutura , Ossificação Heterotópica/induzido quimicamente , Próteses e Implantes , Ratos , Ratos Wistar
8.
Arch Orthop Trauma Surg ; 115(1): 5-9, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8775702

RESUMO

Forty-one Wagner revision stems were implanted at the Orthopedic Department of the University of Tübingen between July 1990 and January 1993. We report the results of 37 patients at an average follow-up of 27 months (13-48 months) postoperatively. The main indication was stem loosening with considerable loss of bone. In addition, we used the implant 4 times in primary arthroplasty. At follow-up examination 33 patients (89%) were satisfied with the postoperative outcome. According to the Merle D'Aubigné score (12-point scale), 32 patients showed a poor functional result of less than 6 points preoperatively. Postoperatively, the results of 36 patients could be classified as very good to good. To categorise the radiological destruction of the implant bed, we used the femoral shaft defect classification of the DGOT (Deutsche Gesellschaft für Orthopädie und Traumatologie) in conjunction with the classification of Pak and Paproski [5, 11]. Twenty patients presented with trochanteric and calcar defects, and 11 patients with a combination of a calcar and shaft defect. We found a circular shaft defect in 2 patients. In 7 cases we assessed the bone remodelling postoperatively as very good, with strong newly formed bone structures, and in 25 cases as good, with remodelling of the old stem bed and bony structuring of the osteolyses. A secondary sinking in of the Wagner stem was seen in 7 cases. Only one stem had to be revised because of pain symptoms and loosening; in all other cases a secondary stabilisation of the revision-stem took place. With the Wagner revision stem, there is the possibility of achieving mechanical stability even in situations with massive bone loss. The evacuation of bone cement and granulation tissues is facilitated by the transfemoral approach, bony remodelling is accelerated, and bone grafting is often not necessary. As our short-term results show, the concept is a promising one. Nevertheless, we will be very careful in following these patients in the long term, as we have noticed stem sinkage in a small percentage of cases.


Assuntos
Prótese de Quadril/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Complicações Pós-Operatórias , Falha de Prótese , Reoperação , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 115(5): 249-54, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8836456

RESUMO

We examined the long-term results of two different methods of shoulder decompression (Neer acromioplasty and resection of the coracoacromial ligament) after an average observation period of 8 years. Clinical and radiological features were evaluated in 48 patients with 50 treated shoulders, as was the subjective result of the treatment in 58 patients with 61 operated joints. Pain was substantially eased in 93% (acromioplasty) and 100% (ligamentary resection), mobility improved in 76% and 83%, respectively. A favourable result was achieved in 86% of the acromioplasty cases and in 75% of the ligament resection cases. In one-third of the shoulders, an increasing degeneration of joint structures could be demonstrated radiologically; the degree depended on the severity of the initial rotator cuff injury, not on the method of shoulder decompression. The differences between both surgical methods examined were not statistically significant, but acromioplasty provides a superior extension of the subacromial space and protection for the reconstructed rotator cuff tendons. Our results compare favourably with other published studies. The methods described are suitable for the treatment of subacromial impingement.


Assuntos
Síndrome de Colisão do Ombro/cirurgia , Atividades Cotidianas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome de Colisão do Ombro/reabilitação , Resultado do Tratamento
10.
Z Orthop Ihre Grenzgeb ; 133(5): 453-5, 1995.
Artigo em Alemão | MEDLINE | ID: mdl-7491805

RESUMO

A new measuring device has been developed at the Orthopedic Clinic of the University of Tübingen. Its task is to ensure that the right length of leg is selected intraoperatively. The method of measurement can be used in all approaches for alloplastic hip replacement when the patient is in the supine position. Measurement is quick, non-invasive, and can be carried out in a direct comparison to the contralateral leg, using measuring points at the iliac crest and the upper edge of the patella. In a prospective randomized study we were able to demonstrate on 53 patients that the use of this newly-developed measuring device improves the accuracy of the length of the operated leg as compared to the contralateral leg, so that the difference is only +/- 0.5 cm (post-operative difference in length of leg without use of the measuring device 1.1 cm on average, with the measuring device 0.5 cm; p < 0.05).


Assuntos
Antropometria/métodos , Prótese de Quadril , Perna (Membro)/anatomia & histologia , Antropometria/instrumentação , Feminino , Humanos , Desigualdade de Membros Inferiores/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
11.
Biomed Tech (Berl) ; 40(4): 99-105, 1995 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-7772712

RESUMO

The alternative to the anchoring of an endoprosthesis by means of cement is the biological fixation by an ingrowth of bone into the implant surface (osseointegration). We examined the implant fixation properties of titanium experimental devices with 3 different surface structures after press-fit implantation into the bony bed of 12 dogs. One third of the 48 implants had a micro-structured surface roughened by grit-blasting, one third a roughened surface with an additional macro-groove structure (combination surface), and the remaining third a porous hydroxyapatite (HA) coating. Twelve weeks after implantation the bony ingrowth was evaluated biomechanically by measuring the force required to pull out the implant from the surrounding bone and histologically by morphometric assessment of microradiographs. In the pull-out-experiment the shearing forces were significantly lower (p < 0.01) in the devices with a roughened surface in comparison to the devices with a micro- and macro-structured surface and the HA surface. Thus, there was no significant difference between the forces required to pull out the devices with the porous HA surface and those with the combination surface. The histomorphometric assessment of bone density in the immediate vicinity of the implant and the extent of the direct contact surface of the bone implant resulted in no significant difference in all 3 groups. We did not find an interposing layer of fibrous tissue at the interface. We can demonstrate that roughening of the surface in combination with a groove structure creates a better bond between implant and bone than a roughening alone.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Prótese de Quadril , Osseointegração/fisiologia , Titânio , Animais , Fenômenos Biomecânicos , Osso e Ossos/patologia , Osso e Ossos/fisiologia , Cães , Feminino , Masculino , Teste de Materiais , Propriedades de Superfície
12.
Sportverletz Sportschaden ; 9(1): 9-13, 1995 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-7778022

RESUMO

Timeless and lesion-related treatment are important in the different shoulder instabilities in order to get a good functional result. Within the step-by-step programme of diagnostic possibilities the double contrast computerised arthrotomography is particularly indicated in recurrent posttraumatic and habitual dislocations, in subluxations as well as for clarification of causes of postoperative recurrence. Besides the documentation of skeletal changes (Hill-Sachs-lesion, Bankart defect), double-contrast arthro-CT offers the possibility to identify detachments of the joint capsule or labral tears. Between 11/90 and 9/93 we performed 38 double contrast arthro-CTs for recurrent shoulder instabilities. 35 men and 3 women were examined. The mean age of the sportive patients were 29 years. Preoperatively we diagnosed in 21 cases a recurrent posttraumatic, in 7 cases a habitual shoulder instability. Apart from one multidirectional and three posterior instabilities we found two cases of subluxation. In the meantime 24 patients were treated with an open stabilising operation of the shoulder. The operative findings were compared with the results of double contrast arthro-CT. In a total of 38 performed arthro-CTs we found labral tears in 4 cases, 14 labral dissections, and 10 times a complete labral discontinuity. 8 of 9 labrum dissections found intraoperatively were correctly identified on CT. One dissection was not even seen retrospectively on arthro-CT. Six of nine complete labrum discontinuities were seen on arthro-CT, three described as a dissection. All capsular detachments and bony Bankart lesions found on CT were confirmed intraoperatively.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Traumatismos em Atletas/diagnóstico por imagem , Meios de Contraste , Instabilidade Articular/diagnóstico por imagem , Luxação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos , Adulto , Traumatismos em Atletas/cirurgia , Transplante Ósseo , Doença Crônica , Feminino , Humanos , Instabilidade Articular/cirurgia , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Recidiva , Reoperação , Luxação do Ombro/cirurgia
13.
Arch Orthop Trauma Surg ; 114(5): 269-73, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7577218

RESUMO

From 1980 through 1991 we screwed a preshaped cortico-cancellous bone graft onto the ileum wall to compensate acetabular deficiency in 94 consecutive total hip replacements. We report the results of 87 hips (79 patients) with an average follow-up of 30 months (12-75 months) postoperatively. Pain in dysplasia-coxarthrosis and congenital dislocation of the hip, destructive coxitis in rheumatoid arthritis and cup loosening was the main indication for surgery. According to the Merle d'Aubigné score the postoperative clinical evaluation demonstrated 77% very good and 18% good results. Due to component loosening the results had to be classified as unsatisfactory in 4 hips (2 cups and 2 stems). At the time of evaluation 90% of the arthroplasties was osseously consolidated as evidenced by trabecular bridging and structural integrity with host bone. Resorptions of the graft were noted in 32 hips. One cup was removed because of complete resorption and consecutive loosening, a further one was considered clinically and radiologically loose because of partial graft resorption. Two further complete resorptions and 28 partial lateral resorptions had no influence on the secondary stability of the implant. We are aware that these are short-term results. Nevertheless, we recommend the described method as a valuable addition to arthroplasties for acetabular rim defects both in osteoarthritis and in revision surgery.


Assuntos
Acetábulo/cirurgia , Artrite/cirurgia , Transplante Ósseo , Cabeça do Fêmur/transplante , Luxação Congênita de Quadril/complicações , Prótese de Quadril/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite/etiologia , Artrite Reumatoide/etiologia , Artrite Reumatoide/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/etiologia , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Transplante Homólogo , Resultado do Tratamento
15.
Z Orthop Ihre Grenzgeb ; 127(3): 296-301, 1989.
Artigo em Alemão | MEDLINE | ID: mdl-2501944

RESUMO

218 Patients, primary treated with total replacement of the hip joint were examined for ectopic ossifications. Frequency and Arcq-classification are described in relation to the transgluteal approach to the hip joint, age, sex an the technic of implantation. We found 3.5% more paraarticular ossifications in the group of cementfixed endoprotheses compared with the group of cementless CAT-endoprotheses type Heramed. In comparison men were affected more often with heterotopic ossifications than women. In both groups the overall incidence of paraarticular ossifications was 34.0%.


Assuntos
Cimentos Ósseos/administração & dosagem , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Ossificação Heterotópica/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...