J Pak Med Assoc ; 62(9): 924-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23139977

RESUMO

OBJECTIVE: To observe the safety of trans-jugular pressure-monitoring catheter insertion at a tertiary care teaching hospital in Rawalpindi, Pakistan. METHODS: The observational study was carried out at the Armed Forces Institute of Cardiology/National Institute of Heart Diseases, Rawalpindi, from January 1, 2004 to March 31, 2010. All patients electively scheduled to undergo cardiac surgery for congenital heart disease who had percutaneous trans-jugular pressure monitoring catheters inserted peri-operatively were included in the study. Dedicated Medtronic 3 Fr pressure monitoring catheters were passed through internal jugular vein using the modified Seldinger. The patients were followed up during the hospital stay for complications related to catheter insertion/removal. Data was analysed using SPSS version 15. RESULTS: Of the 572 patients in the study, the catheters were ultimately positioned with the tips in the pulmonary artery in 447 (78.14%)patients, right ventricle 54 (9.44%) patients, left atrium in 52 (9.09%), and in both pulmonary artery and left atrium in 19 (3.32%) patients. Duration of pressure monitoring from all the chambers was 53 +/- 19 hours post-operatively. Transient and self-limiting atrial or ventricular ectopic beats were noticed in 163 (27.58%) patients during insertion. Catheter was found to be non-functional in 12 (2.03%) patients. Only one (0.16%) patient experienced recurrent tachyarrhythmia which required the withdrawal of catheter. CONCLUSION: Insertion of trans-jugular pressure monitoring catheters during cardiac surgery for congenital heart disease is a safe and reliable technique.


Assuntos
Arritmias Cardíacas/etiologia , Cateterismo Venoso Central , Cardiopatias Congênitas/cirurgia , Veias Jugulares/cirurgia , Monitorização Intraoperatória , Complicações Pós-Operatórias/diagnóstico , Pressão Atrial , Procedimentos Cirúrgicos Cardíacos/métodos , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/métodos , Cateteres Venosos Centrais/efeitos adversos , Pré-Escolar , Análise de Falha de Equipamento , Feminino , Humanos , Lactente , Masculino , Monitorização Intraoperatória/efeitos adversos , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Paquistão , Artéria Pulmonar/cirurgia , Pressão Propulsora Pulmonar , Reprodutibilidade dos Testes , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...