Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Arthrosc Tech ; 13(5): 102943, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38835450

RESUMO

Iterative evolutions in arthroscopic rotator cuff repair aim to improve its biomechanical and biological properties. This technical note describes an arthroscopic rotator cuff repair technique that combines the advantages of a modified Mason-Allen suture technique with the advantages of an arthroscopic transosseous-equivalent construct. Two alternatives for creating this construct are described. The Mason-Allen stitch is easy to perform, is cost-effective, and increases tissue security without tendon strangulation. The arthroscopic transosseous-equivalent construct increases footprint contact pressure and coverage, aiding healing of the repaired rotator cuff.

2.
J Clin Med ; 13(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38592100

RESUMO

Three-dimensional (3D) deformity assessment and leg realignment planning is emerging. The aim of this study was to (1) validate a novel 3D planning modality that incorporates the weight-bearing (WB) state (3D WB) by comparing it to existing modalities (3D non-weight-bearing (NWB), 2D WB) and (2) evaluate the influence of the modality (2D vs. 3D) and the WB condition on the measurements. Three different planning and deformity measurement protocols were analyzed in 19 legs that underwent medial open-wedge high tibial osteotomy (HTO): (1) a 3D WB protocol, after 2D/3D registration of 3D CT models onto the long-leg radiograph (LLR) (3D WB), (2) a 3D NWB protocol based on the 3D surface models obtained in the supine position (3D NWB), and (3) a 2D WB protocol based on the LLR (2D WB). The hip-knee-ankle angle (HKA), joint line convergence angle (JLCA), and the achieved surgical correction were measured for each modality and patient. All the measurement protocols demonstrated excellent intermodal agreement for the achieved surgical correction, with an ICC of 0.90 (95% CI: 0.76-0.96)) (p < 0.001). Surgical correction had a higher mean absolute difference compared to the 3D opening angle (OA) when measured with the WB protocols (3D WB: 2.7 ± 1.8°, 3D NWB: 1.9 ± 1.3°, 2D WB: 2.2 ± 1.3°), but it did not show statistical significance. The novel planning modality (3D WB) demonstrated excellent agreement when measuring the surgical correction after HTO compared to existing modalities.

4.
Am J Sports Med ; 52(2): 441-450, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38259113

RESUMO

BACKGROUND: Arthroscopic rotator cuff repair (ARCR) is among the most commonly performed orthopaedic procedures. Several factors-including age, sex, and tear severity-have been identified as predictors for outcome after repair. The influence of the tear etiology on functional and structural outcome remains controversial. PURPOSE: To investigate the influence of tear etiology (degenerative vs traumatic) on functional and structural outcomes in patients with supraspinatus tendon tears. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: Patients undergoing ARCR from 19 centers were prospectively enrolled between June 2020 and November 2021. Full-thickness, nonmassive tears involving the supraspinatus tendon were included. Tears were classified as degenerative (chronic shoulder pain, no history of trauma) or traumatic (acute, traumatic onset, no previous shoulder pain). Range of motion, strength, the Subjective Shoulder Value, the Oxford Shoulder Score (OSS), and the Constant-Murley Score (CMS) were assessed before (baseline) and 6 and 12 months after ARCR. The Subjective Shoulder Value and the OSS were also determined at the 24-month follow-up. Repair integrity after 12 months was documented, as well as additional surgeries up to the 24-month follow-up. Tear groups were compared using mixed models adjusted for potential confounding effects. RESULTS: From a cohort of 973 consecutive patients, 421 patients (degenerative tear, n = 230; traumatic tear, n = 191) met the inclusion criteria. The traumatic tear group had lower mean baseline OSS and CMS scores but significantly greater score changes 12 months after ARCR (OSS, 18 [SD, 8]; CMS, 34 [SD,18] vs degenerative: OSS, 15 [SD, 8]; CMS, 22 [SD, 15]) (P < .001) and significantly higher 12-month overall scores (OSS, 44 [SD, 5]; CMS, 79 [SD, 9] vs degenerative: OSS, 42 [SD, 7]; CMS, 76 [SD, 12]) (P≤ .006). At the 24-month follow-up, neither the OSS (degenerative, 44 [SD, 6]; traumatic, 45 [SD, 6]; P = .346) nor the rates of repair failure (degenerative, 14 [6.1%]; traumatic 12 [6.3%]; P = .934) and additional surgeries (7 [3%]; 7 [3.7%]; P = .723) differed between groups. CONCLUSION: Patients with degenerative and traumatic full-thickness supraspinatus tendon tears who had ARCR show satisfactory short-term functional results. Although patients with traumatic tears have lower baseline functional scores, they rehabilitate over time and show comparable clinical results 1 year after ARCR. Similarly, degenerative and traumatic rotator cuff tears show comparable structural outcomes, which suggests that degenerated tendons retain healing potential.


Assuntos
Lacerações , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Estudos de Coortes , Dor de Ombro/diagnóstico por imagem , Dor de Ombro/etiologia , Dor de Ombro/cirurgia , Resultado do Tratamento , Ruptura/cirurgia , Artroscopia/métodos , Amplitude de Movimento Articular , Estudos Retrospectivos , Imageamento por Ressonância Magnética
5.
Orthop J Sports Med ; 11(10): 23259671231176295, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37810740

RESUMO

Background: In patients with osteochondral lesion, defects of the medial talus, or failed cartilage surgery, a periarticular osteotomy can unload the medial compartment. Purpose: To compare the effects of supramalleolar osteotomy (SMOT) versus sliding calcaneal osteotomy (SCO) for pressure redistribution and unloading of the medial ankle joint in normal, varus-aligned, and valgus-aligned distal tibiae. Study Design: Controlled laboratory study. Methods: Included were 8 cadaveric lower legs with verified neutral ankle alignment (lateral distal tibial angle [LDTA] = 0°) and hindfoot valgus within normal range (0°-10°). SMOT was performed to modify LDTA between 5° valgus, neutral, and 5° varus. In addition, a 10-mm lateral SCO was performed and tested in each position in random order. Axial loading (700 N) of the tibia was applied with the foot in neutral alignment in a customized testing frame. Pressure distribution in the ankle joint and subtalar joint, center of force, and contact area were recorded using high-resolution Tekscan pressure sensors. Results: At neutral tibial alignment, SCO unloaded the medial joint by a mean of 10% ± 10% or 66 ± 51 N (P = .04) compared with 6% ± 12% or 55 ± 72 N with SMOT to 5° valgus (P = .12). The achieved deload was not significantly different (ns) between techniques. In ankles with 5° varus alignment at baseline, SMOT to correct LDTA to neutral insufficiently addressed pressure redistribution and increased medial load by 6% ± 9% or 34 ± 33 N (ns). LDTA correction to 5° valgus (10° SMOT) unloaded the medial joint by 0.4% ± 14% or 20 ± 75 N (ns) compared with 9% ± 11% or 36 ± 45 N with SCO (ns). SCO was significantly superior to 5° SMOT (P = .017) but not 10° SMOT. The subtalar joint was affected by both SCO and SMOT, where SCO unloaded but SMOT loaded the medial side. Conclusion: SCO reliably unloaded the medial compartment of the ankle joint for a neutral tibial axis. Changes in the LDTA by SMOT did not positively affect load distribution, especially in varus alignment. The subtalar joint was affected by SCO and SMOT in opposite ways, which should be considered in the treatment algorithm. Clinical Relevance: SCO may be considered a reliable option for beneficial load-shifting in ankles with neutral alignment or 5° varus malalignment.

6.
Arch Orthop Trauma Surg ; 143(9): 5935-5944, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36806985

RESUMO

INTRODUCTION: Due to multiplanar deformities of the hip, total hip arthroplasty (THA) for sequelae of Legg-Calvé-Perthes disease (LCPD) is often technically demanding. This study aimed to compare the clinical and radiographic outcomes of patients with sequelae of LCPD undergoing THA through the direct anterior approach (DAA) and non-anterior approaches to the hip. METHODS: All patients with sequelae of LCPD who underwent primary THA between 2004 and 2018 (minimum follow-up: 2 years) were evaluated and separated into two groups: THA through the DAA (Group AA), or THA through non-anterior approaches to the hip (Group non-AA). Furthermore, a consecutive control group of patients undergoing unilateral THA through the DAA for primary hip osteoarthritis (Group CC) was retrospectively reviewed for comparison. RESULTS: Group AA comprises 14 hips, group non-AA 17 hips and group CC 30 hips. Mean follow-up was 8.6 (± 5.2; 2-15), 9.0 (± 4.6; 3-17) and 8.1 (± 2.2; 5-12) years, respectively. At latest follow-up, Harris Hip Score was 90 (± 20; 26-100), 84 (± 15; 57-100), and 95 (± 9; 63-100) points, respectively. Overall, 6 patients treated for LCPD (each 3 patient in the AA and non-AA group) developed postoperative sciatic nerve palsy, of which only one was permanent. Complication-related revision rate at the latest follow-up was 15% in the AA-group and 25% in the non-AA group, respectively. CONCLUSION: THA through the DAA might be a credible option for the treatment of sequelae of LCPD with comparable complication rates and functional outcomes to non-anterior approaches.


Assuntos
Artroplastia de Quadril , Doença de Legg-Calve-Perthes , Humanos , Doença de Legg-Calve-Perthes/complicações , Doença de Legg-Calve-Perthes/cirurgia , Artroplastia de Quadril/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Progressão da Doença
7.
BMC Musculoskelet Disord ; 23(1): 962, 2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36348364

RESUMO

BACKGROUND: Computer-assisted techniques for surgical treatment of femoral deformities have become increasingly important. In state-of-the-art 3D deformity assessments, the contralateral side is used as template for correction as it commonly represents normal anatomy. Contributing to this, an iterative closest point (ICP) algorithm is used for registration. However, the anatomical sections of the femur with idiosyncratic features, which allow for a consistent deformity assessment with ICP algorithms being unknown. Furthermore, if there is a side-to-side difference, this is not considered in error quantification. The aim of this study was to analyze the influence and value of the different sections of the femur in 3D assessment of femoral deformities based on the contralateral anatomy. MATERIAL AND METHODS: 3D triangular surface models were created from CT of 100 paired femurs (50 cadavers) without pathological anatomy. The femurs were divided into sections of eponymous anatomy of a predefined percentage of the whole femoral length. A surface registration algorithm was applied to superimpose the ipsilateral on the contralateral side. We evaluated 3D femoral contralateral registration (FCR) errors, defined as difference in 3D rotation of the respective femoral section before and after registration to the contralateral side. To compare this method, we quantified the landmark-based femoral torsion (LB FT). This was defined as the intra-individual difference in overall femoral torsion using with a landmark-based method. RESULTS: Contralateral rotational deviation ranged from 0° to 9.3° of the assessed femoral sections, depending on the section. Among the sections, the FCR error using the proximal diaphyseal area for registration was larger than any other sectional error. A combination of the lesser trochanter and the proximal diaphyseal area showed the smallest error. The LB FT error was significantly larger than any sectional error (p < 0.001). CONCLUSION: We demonstrated that if the contralateral femur is used as reconstruction template, the built-in errors with the registration-based approach are smaller than the intraindividual difference of the femoral torsion between both sides. The errors are depending on the section and their idiosyncratic features used for registration. For rotational osteotomies a combination of the lesser trochanter and the proximal diaphyseal area sections seems to allow for a reconstruction with a minimal error.


Assuntos
Doenças Ósseas , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Osteotomia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fêmur/anormalidades , Algoritmos , Cadáver
8.
Orthop J Sports Med ; 10(5): 23259671221091264, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35547613

RESUMO

Background: Although length change patterns of the medial knee structures have been reported, either the weightbearing state was not considered or quantitative radiographic landmarks that allow the identification of the insertion sites were not reported. Purpose: To (1) analyze the length changes of the superficial medial collateral ligament (sMCL) and posterior oblique ligament (POL) under weightbearing conditions and (2) to identify the femoral sMCL insertion site that demonstrates the smallest length changes during knee flexion and report quantitative radiographic landmarks. Study Design: Descriptive laboratory study. Methods: The authors performed a 3-dimensional (3D) analysis of 10 healthy knees from 0° to 120° of knee flexion using weightbearing computed tomography (CT) scans. Ligament length changes of the sMCL and POL during knee flexion were analyzed using an automatic string generation algorithm. The most isometric femoral insertion of the sMCL that demonstrated the smallest length changes throughout the full range of motion (ROM) was identified. Radiographic landmarks were reported on an isometric grid defined by a true lateral view of the 3D CT model and transferred to a digitally reconstructed radiograph. Results: The sMCL demonstrated small ligament length changes, and the POL demonstrated substantial shortening during knee flexion (P = .005). Shortening of the POL started from 30° of flexion. The most isometric femoral sMCL insertion was located 0.6 ± 1.7 mm posterior and 0.8 ± 1.2 mm inferior to the center of the sMCL insertion and prevented ligament length changes >5% during knee flexion in all participants. The insertion was located 47.8% ± 2.7% from the anterior femoral cortex and 46.3% ± 1.9% from the joint line on a true lateral 3D CT view. Conclusion: The POL demonstrated substantial shortening starting from 30° of knee flexion and requires tightening near full extension to avoid overconstraint. Femoral sMCL graft placement directly posteroinferior to the center of the anatomical insertion of the sMCL demonstrated the most isometric behavior during knee flexion. Clinical Relevance: The described elongation patterns of the sMCL and POL aid in guiding surgical medial knee reconstruction and preventing graft lengthening and overconstraint of the medial compartment. Repetitive graft lengthening is associated with graft failure, and overconstraint leads to increased compartment pressure, cartilage degeneration, and restricted ROM.

9.
Orthop J Sports Med ; 10(4): 23259671221090219, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35464904

RESUMO

Background: The isometric characteristics of nonanatomic and anatomic posterolateral corner (PLC) reconstruction techniques under weightbearing conditions remain unclear. Purpose: To (1) simulate graft elongation patterns during knee flexion for 3 different PLC reconstruction techniques (Larson, Arciero, and LaPrade) and (2) compute the most isometric insertion points of the fibular collateral ligament (FCL) graft strands for each technique and report quantitative radiographic landmarks. Study Design: Descriptive laboratory study. Methods: The authors performed a 3-dimensional simulation of 10 healthy knees from 0° to 120° of flexion using weightbearing computed tomography (CT) scans. The simulation was used to calculate ligament length changes during knee flexion for the PLC reconstruction techniques of Larson (nonanatomic single-bundle fibular sling reconstruction), Arciero (anatomic reconstruction with additional popliteofibular ligament graft strand), and LaPrade (anatomic reconstruction with popliteofibular ligament graft strand and popliteus tendon graft strand). The most isometric femoral insertion points for the FCL graft strands were computed within a 10-mm radius around the lateral epicondyle (LE), using an automatic string generation algorithm (0 indicating perfect isometry). Radiographic landmarks for the most isometric points were reported. Results: Median graft lengthening during knee flexion was similar for the anterior graft strands of all 3 techniques. The posterior graft strands demonstrated significant differences, from lengthening for the Arciero (9.9 mm [range, 6.7 to 15.9 mm]) and LaPrade (10.2 mm [range, 4.1 to 19.7 mm]) techniques to shortening for the Larson technique (-17.1 mm [range, -9.3 to -22.3 mm]; P < .0010). The most isometric point for the FCL graft strands of all techniques was located at a median of 2.2 mm (range, -2.2 to 4.5 mm) posterior and 0.3 mm (range, -1.8 to 3.7 mm) distal to the LE. Conclusion: Overconstraint can be avoided by tensioning the posterior graft strands in the Larson technique in extension, and in the Arciero and LaPrade techniques at a minimum of 60° of knee flexion. The most isometric point was located posterodistal to the LE. Clinical Relevance: The described isometric behavior of nonanatomic and anatomic PLC reconstruction techniques can guide optimal surgical reconstruction and prevent graft lengthening and overconstraint of the lateral compartment in knee flexion. Repetitive graft lengthening has been found to be associated with graft failure, and overconstraint favors lateral compartment pressure and cartilage degeneration.

10.
Knee Surg Sports Traumatol Arthrosc ; 30(11): 3651-3658, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35438307

RESUMO

PURPOSE: Rotation of the tibia relative to the femur was recently identified as a contributing risk factor for patellar instability, and correlated with its severity. The hypothesis was that in patellofemoral dysplastic knees, an increase in femorotibial rotation can be reliably detected on anteroposterior (AP) radiographs by an overlap of the lateral femoral condyle over the lateral tibial eminence. METHODS: Sixty patients (77 knees) received low-dose computed tomography (CT) of the lower extremity for assessment of torsional malalignment due to recurrent patellofemoral instability. Three-dimensional (3D) surface models were created to assess femorotibial rotation and its relationship to other morphologic risk factors of patellofemoral instability. On weight-bearing AP knee radiographs, a femoral condyle/lateral tibial eminence superimposition was defined as a positive winking sign. Using digitally reconstructed radiographs of the 3D models, susceptibility of the winking sign to vertical/horizontal AP knee radiograph malrotation was investigated. RESULTS: A positive winking sign was present in 30/77 knees (39.0%) and indicated a 6.3 ± 1.4° increase in femorotibial rotation (p < 0.001). Femoral condyle/tibial eminence superimposition of 1.9 mm detected an increased femorotibial rotation (> 15°) with 43% sensitivity and 90% specificity (AUC = 0.72; p = 0.002). A positive winking sign (with 2 mm overlap) disappeared in case of a 10° horizontally or 15° vertically malrotated radiograph, whereas a 4 mm overlap did not disappear at all, regardless of the quality of the radiograph. In absence of a winking sign, on the other hand, no superimposition resulted within 20° of vertical/horizontal image malrotation. Femorotibial rotation was positively correlated to TT-TG (R2 = 0.40, p = 0.001) and patellar tilt (R2 = 0.30, p = 0.001). CONCLUSIONS: The winking sign reliably indicates an increased femorotibial rotation on a weight-bearing AP knee radiograph and could prove useful for day-by-day clinical work. Future research needs to investigate whether femorotibial rotation is not only a prognostic factor but a potential surgical target in patients with patellofemoral disorders. LEVEL OF EVIDENCE: III.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Piscadela , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Patela , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
11.
Arch Orthop Trauma Surg ; 142(11): 3103-3110, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33970321

RESUMO

BACKGROUND: Progressive collapsing foot deformity (PCFD) is a complex 3-dimensional (3-D) deformity with varying degrees of hindfoot valgus, forefoot abduction, and midfoot varus. The first aim of this study was to perform a 3-D analysis of the talus morphology between symptomatic PCFD patients that underwent operative flatfoot correction and controls. The second aim was to investigate if there is an impact of individual talus morphology on the success of operative flatfoot correction. METHODS: We reviewed all patients that underwent lateral calcaneal lengthening for correction of PCFD between 2008 and 2018 at our clinic. Radiographic flatfoot parameters on preoperative and postoperative radiographs were assessed. Additionally, 3-D surface models of the tali were generated using computed tomography (CT) data. The talus morphology of 44 flatfeet was compared to 3-D models of 50 controls without foot or ankle pain of any kind. RESULTS: Groups were comparable regarding demographics. Talus morphology differed significantly between PCFD and controls in multiple aspects. There was a 2.6° increased plantar flexion (22.3° versus 26°; p = 0.02) and medial deviation (31.7° and 33.5°; p = 0.04) of the talar head in relation to the body in PCFD patients compared to controls. Moreover, PCFD were characterized by an increased valgus (difference of 4.6°; p = 0.01) alignment of the subtalar joint. Satisfactory correction was achieved in all cases, with an improvement of the talometatarsal-angle and the talonavicular uncoverage angle of 5.6° ± 9.7 (p = 0.02) and 9.9° ± 16.3 (p = 0.001), respectively. No statistically significant correlation was found between talus morphology and the correction achieved or loss of correction one year postoperatively. CONCLUSION: The different morphological features mentioned above might be contributing or risk factors for progression to PCFD. However, despite the variety of talar morphology, which is different compared to controls, the surgical outcome of calcaneal lengthening osteotomy was not affected. LEVEL OF EVIDENCE: III.


Assuntos
Calcâneo , Pé Chato , Tálus , Calcâneo/diagnóstico por imagem , Calcâneo/cirurgia , Pé Chato/diagnóstico por imagem , Pé Chato/etiologia , Pé Chato/cirurgia , , Humanos , Osteotomia/métodos , Tálus/diagnóstico por imagem , Tálus/cirurgia
12.
Arch Orthop Trauma Surg ; 142(11): 3149-3155, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33978809

RESUMO

BACKGROUND: This study aimed to quantify the effect of lower limb rotational parameters on the difference in the tibial-tubercle-trochlear-groove (TTTG) distance when assessed with magnetic resonance imaging (MRI) and computed tomography (CT) in patients with patellar instability. It was hypothesized that an increased native knee rotation angle significantly contributes to an underestimation of TTTG by MRI. METHODS: Forty patients with patellar instability who had undergone standard radiographs, MRI and CT scans were included in this retrospective study. A musculoskeletal radiologist assessed all imaging for TTTG, femoral and tibial rotation, knee rotation and flexion angle, and trochlear dysplasia. ΔTTTG was defined as the TTTG measured on MRI subtracted from the TTTG measured on CT. Statistical analysis determined the effect of these parameters on the calculated difference between TTTG when measured on CT and MRI. RESULTS: Equal knee flexion in MRI and CT resulted in a ΔTTTG of 0.1 ± 0.3 mm compared to 4.0 ± 3.3 mm in patients with different knee flexion angles in both imaging acquisitions (p = 0.036). The knee rotation angle measured on CT (native knee rotation angle) was negatively correlated with ΔTTTG (r = - 0.365; p = 0.002), while neither tibial nor femoral rotation showed any associations with TTTG (n.s.). Trochlear dysplasia did not show any significant correlation with ΔTTTG, regardless of classification by Dejour or Lippacher (n.s.). Both the native knee rotation angle and the MRI knee flexion angle were independent predictors of ΔTTTG, yet with an opposing effect (knee rotation: 95% Confidence Interval [CI] for ß - 0.468 to - 0.154, p < 0.001; knee flexion 95% CI for ß 0.292 to 0.587, p < 0.001). Patients with a native knee rotation angle > 20° showed a ΔTTTG of - 5.8 ± 4.0 mm (MRI rather overestimates TTTG) compared to 0.9 ± 4.1 mm Δ TTTG (MRI rather underestimates TTTG) in patients with < 20° native knee rotation angle. CONCLUSION: The native knee rotation angle is an independent, inversely correlated predictor of ΔTTTG, thus opposing the effect of knee flexion during MRI acquisition. Consequently, these results suggest that not only knee flexion but also knee rotation should be appreciated when assessing TTTG during patellar instability diagnostic evaluation as it can potentially lead to a false estimation of the TTTG distance on MRI. LEVEL OF EVIDENCE: Level III.


Assuntos
Instabilidade Articular , Luxação Patelar , Articulação Patelofemoral , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Extremidade Inferior , Imageamento por Ressonância Magnética/métodos , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/patologia , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/patologia , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/patologia , Tomografia Computadorizada por Raios X
13.
JSES Int ; 5(4): 679-687, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34223415

RESUMO

BACKGROUND: Functional internal rotation (fIR) of the shoulder is frequently limited after reverse shoulder arthroplasty (RTSA). The objective of this study was to study a cohort of satisfied patients after RTSA who had comparable active mobility except for fIR and to identify factors associated with selective loss of fIR. METHODS: A retrospective cohort study was conducted to compare 2 patient groups with either poor (≤ 2 points in the Constant-Murley score [CS]) or excellent (≥8 points in CS) fIR after RTSA at a minimum follow-up of 2 years. Influencing factors (demographic, surgical or implant related, radiographic parameters) and clinical outcome were analyzed. RESULTS: Fifty-two patients with a mean age of 72.8 (±9.3) and a mean follow-up of 41 months were included in the IR≤2 group and 63 patients with a mean age of 72.1 (±8.0) and a mean follow-up of 59 months in the IR≥8 group. All patients had undergone RTSA with the same implant type and only 2 different glenosphere sizes (36 and 40) for comparable indications. A multivariate analysis identified the following significant risk factors for poor postoperative fIR: poor preoperative fIR (pts in CS: 3 [range: 2-6] vs. 6 [range: 4-8], P<.0001), smoking (17.3% vs. 6.5%, P = .004), male gender (59.6% vs. 31.7%, P = .002), less preoperative to postoperative distalization of the greater tuberosity (Δ 19.4 mm vs. 22.2 mm, P = .026), a thin humeral insert (≤3 mm: 23.1% vs. 54.8%, P = .039), and a high American Society of Anesthesiologists score (≤ III: 30.8% vs. 14.3%, P = .043). Subscapularis repair status and glenosphere size had no influence on fIR. Clinical outcome scores improved in both groups from preoperatively to last follow-up. The IR≥8 group had overall significantly better outcome scores compared to the IR≤2 group (Δ 9.3% SSV and Δ 9.5% relative CS, P < .0001). There was no difference in CS between the cohorts when the score for fIR was discarded. CONCLUSION: Independent risk factors for poor postoperative fIR after RTSA are poor preoperative fIR, smoking, male gender, less preoperative to postoperative distalization of the greater tuberosity, a thin humeral insert height, and a high American Society of Anesthesiologists score. Except for male gender, these factors are modifiable. These findings may be a valuable addition to patient counselling as well as preoperative planning and preoperative and intraoperative decision-making. The relevance of fIR for overall satisfaction is substantiated by this study.

14.
BMC Musculoskelet Disord ; 22(1): 268, 2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33706727

RESUMO

BACKGROUND: Preoperative templating in total hip arthroplasty (THA) is mandatory to achieve appropriate offset and leg length equality. However, templating methods using the contralateral hip might be susceptible to errors resulting from side-differences in the femoral morphology. The distance of the lesser trochanter to the femoral head center (LTFHD) is a frequently used reference parameter for preoperative planning and intraoperative validation during THA. However, currently no three-dimensional (3D) analysis of side differences of the LTFHD exists. METHODS: Using Computer tomography (CT)-based surface models from 100 paired femora (50 cadavers), side-to-side asymmetry of the LTFHD, femoral length, femoral head diameter (FHD) and femoral antetorsion were analyzed. Univariate linear regression models were established to evaluate potential associations between sides regarding LTFHD and FHD as well as a correlation of these parameters with each other. RESULTS: Statistically significant side-differences were found for the LTFHD (p = 0.02) and FHD (p = 0.03) with a mean absolute side-difference of 1.6 ± 1.4mm (range 0.1-5.5mm) and 0.4mm ± 0.6mm (range 0-3mm), respectively. The ratio between the LTFHD and FHD was consistent with an average value of 1.16 ± 0.08 and reliable between sides with a correlation coefficient (r) of 0.72 (p < 0.01). CONCLUSIONS: The LTFHD is a reliable reference parameter for preoperative templating and intraoperative validation during THA with a high correlation between sides (r = 0.93, p < 0.01). However, 8 % of the investigated specimens revealed a LTFHD of more than 4mm, which should be anticipated during THA to avoid unsatisfiable results.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Tomografia Computadorizada por Raios X
15.
Arthrosc Tech ; 10(2): e263-e267, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33680754

RESUMO

Several reconstruction techniques for irreparable tears of the subscapularis tendon have been described with variable results regarding pain relief, functional recovery, and dynamic stabilization of the glenohumeral joint. Because of a more advantageous direction of movement compared with previously described transfer techniques such as transfer of the pectoralis major and pectoralis minor tendons, the anterior latissimus dorsi (LD) transfer has been proposed as a potentially beneficial treatment method. This Technical Note aims to introduce an alternative technique for the anterior LD transfer that combines the advantages of a proper muscle release and tendon reinforcement through an axillary incision with the arthroscopic intra-articular and periarticular work, including detachment of the LD tendon from its humeral insertion and reattachment at the lesser tuberosity.

16.
J Orthop Surg Res ; 16(1): 19, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33413463

RESUMO

BACKGROUND: There has been an evolution in cementless total hip arthroplasty (THA) with newer short stem designs aimed to preserve metaphyseal bone stock and facilitate implantation through minimally invasive approaches. While early subsidence has been correlated to aseptic loosening in conventional stems, there is a paucity of data regarding short stems. The current study aims to report on stem subsidence and mid-term clinical outcomes of a cementless, metaphyseal-anchored short femoral stem, specifically designed for the direct anterior approach (DAA). METHODS: Ninety-four consecutive patients (100 hips) with a minimum follow-up of 5 years following cementless THA were included in this single-center retrospective study. Subsidence was evaluated using the "Ein-Bild-Roentgen-Analyse" (EBRA). Periprosthetic radiolucency allocated to the zones of Charnley and Gruen was assessed. Additionally, demographic and implant-related factors potentially associated with increased subsidence and clinical outcomes were evaluated. RESULTS: At the last follow-up, the average stem subsidence was 1.98 ± 1.20 mm, with 48% of the implants demonstrating subsidence of > 2 mm. Periprosthetic radiolucency of > 2 mm was found in 26% of the implants in zone 1 and in 9% in zone 7, respectively. Neither the amount of subsidence nor proximal periprosthetic radiolucency was associated with aseptic loosening or worse clinical outcomes. CONCLUSIONS: Comparable to other proximally fixed short stem designs, the highest subsidence was observed within the first 3 months following implantation. No demographic or implant-related factors were found to have a statistically significant influence on stem subsidence. Periprosthetic radiolucency and subsidence of the AMISstem is not correlated with worse clinical outcomes at 5-year follow-up.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Prótese de Quadril , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Idoso , Cimentos Ósseos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
17.
Arch Orthop Trauma Surg ; 141(5): 871-878, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32778919

RESUMO

BACKGROUND: The purpose of this study was to compare the clinical and radiological outcomes following open reduction and internal fixation (ORIF) of Vancouver B2 periprosthetic femoral fractures versus stem revision (SR) surgery. METHODS: Between 2004 and 2018, 39 patients were treated with SR and 31 with ORIF for a Vancouver type B2. Mean follow-up was 40.4 months for the ORIF group and 43.5 months for the SR group. 22 of 31 stems in the ORIF group were uncemented, of which 7 (23%) were short stems. Perioperative complications, intraoperative blood loss, revision rate, and mortality were recorded. Functional outcomes included Harris Hip Score, Parker Mobility Score and hip abductor strength. RESULTS: Both groups did not differ in the American Society of Anesthesiologists (ASA) score, Charlson comorbidity index, body mass index, age, and sex. Compared to SR, patients treated with ORIF had a decreased blood loss, transfusion rate, operation duration, and mortality. Total complication and re-operation rates were similar. The relative risk for complication and re-operation was 0.5 and 0.7, respectively, in favour of ORIF. CONCLUSIONS: ORIF might be a valuable alternative to SR in the treatment of Vancouver type B2 periprosthetic fractures with shorter operation duration, lower blood loss and similar complication rate compared to SR. Moreover, re-stabilization seems possible irrespective of stem's design or fixation technique. LEVEL OF EVIDENCE: Level III.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Redução Aberta , Fraturas Periprotéticas/cirurgia , Reoperação , Humanos , Complicações Pós-Operatórias , Resultado do Tratamento
18.
Arch Orthop Trauma Surg ; 140(8): 1125-1132, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32385577

RESUMO

BACKGROUND: To date, only limited literature exists regarding revision of total hip arthroplasty (THA) through the direct anterior approach (DAA). However, as the popularity of the DAA for primary surgery is increasing, surgeons will be confronted with the challenge of performing revision surgery through the DAA. The aim of this study was to review the potential of the DAA in the revision setting and to report the clinical results, radiologic outcomes and complication rates of 63 patients undergoing revision THA through the DAA. METHODS: From 01/2009 to 08/2017, 63 patients underwent revision THA through the DAA. Depending on the performed procedure, patients were separated into 4 groups: liner and head exchange (21 patients), revision of the acetabular cup (26 patients), revision of the femoral stem (13 patients) or revision of both components (3 patients). Postoperative complications as well as the clinical and radiological outcome were assessed retrospectively. RESULTS: At a mean follow-up of 18 months, the overall complication and re-operation rates were 14.3% and 12.7%, respectively. Specifically, the complication and re-operation rates were 14.2% and 9.5% after liner and head exchange, 15.4% after revision of the acetabular cup, 15.3% after revision of the femoral stem and 0% after revision of both components. The mean postoperative HHS at 1 year postoperatively was 91 (range 74-100). CONCLUSION: The DAA offers appropriate exposure for exchange of mobile liners and acetabular cup revision. In selected cases with appropriate stem design, femoral stem revision through the DAA is feasible. However, surgeons should be aware of the technical difficulties related to femoral revision and be prepared to extend the approach distally or perform a trochanteric osteotomy.


Assuntos
Artroplastia de Quadril , Reoperação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Humanos , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento
19.
Arch Orthop Trauma Surg ; 140(6): 807-813, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32193676

RESUMO

BACKGROUND: Implant malpositioning, low surgical caseload, and improper patient selection have been identified as essential factors, which could negatively affect the longevity of unicompartmental knee arthroplasty (UKA). The aim of the current study was to evaluate the impact of the surgeon's caseload on patient selection, component positioning, as well as component survivorship and functional outcomes following a PSI-UKA. METHODS: A total of 125 patient-specific instrumented (PSI) UKA were included. One hundred and two cases were treated by a high-volume surgeon (usage 40%) and 23 cases by a low-volume surgeon (< 10 cases/year, usage 34%). Preoperative UIS, as well as the postoperative clinical and radiologic outcome, were assessed retrospectively. RESULTS: Irrespective of the surgeon's UKA caseload, PSI allowed good accuracy in component positioning (p > 0.05). The high-volume surgeon had a more strict indication for UKA with 89% showing a UIS > 25 (considered a good indication) compared to 70% for the low-volume surgeon (p = 0.016). The low-volume surgeon achieved worse results regarding functional outcome (p < 0.05) and a tendency toward an increased risk for UKA failure (p = 0.11) compared to the high-volume surgeon. CONCLUSION: Due to potential selection errors, mostly connected to a low UKA-caseload, low-volume UKA surgeons might achieve worse outcomes. Very strict indications for UKA might be recommended in low-volume surgeons to achieve excellent clinical outcomes following a UKA.


Assuntos
Artroplastia do Joelho , Seleção de Pacientes , Cirurgiões/estatística & dados numéricos , Carga de Trabalho/estatística & dados numéricos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/normas , Artroplastia do Joelho/estatística & dados numéricos , Humanos , Estudos Retrospectivos
20.
Arch Orthop Trauma Surg ; 140(11): 1641-1647, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31982927

RESUMO

BACKGROUND: Direct fixation of posterior malleolar fractures has been shown to lead to higher accuracy of fracture reduction compared to an indirect anterior to posterior fixation but lacks long-term clinical results. This study shows the mid- to long-term clinical and radiological outcome after direct fixation of the posterior malleolus through a posterolateral approach. MATERIALS AND METHODS: Thirty-six patients with an ankle fracture including a posterior malleolar fragment (23 × AO-44C, 12 × AO-44B, 1 × unclassifiable) treated with direct fixation of the fragment through a posterolateral approach were retrospectively evaluated. There were 24 females (67%) with a mean age of 63 (range 34-80) years and a BMI of 28 (range 19-41) kg/m2 at the time of surgery. An initial fracture-dislocation was seen in 67%. The clinical outcome was assessed with the Visual Analog Scale (VAS, 0-10 points) and the American Foot and Ankle Society (AOFAS, 0-100 points) score. Posttraumatic osteoarthritis was recorded with the Van Dijk Classification (grade 0-III). Subgroup analyses of patient- and fracture-associated risk factors (age, BMI, smoking, fracture-dislocation, postoperative articular step-off) were assessed to reveal possible negative prognostic predictors. RESULTS: After a mean follow-up of 7.9 (range 3-12) years, the median VAS was 1 (IQR 0-2) point, and the median AOFAS score was 96 (IQR 88-100) points. Ankle range of motion measurements showed a significant, but clinically irrelevant, difference in plantar- and dorsiflexion between the affected and unaffected ankle. 92% of the patients were very satisfied or satisfied with the postoperative course. 89% had no preoperative signs of ankle osteoarthritis. Osteoarthritis progression was seen in 72%, with 50% showing grade II or III osteoarthritis at the final follow-up. No significant negative prognostic factors for a worse clinical outcome could be detected. CONCLUSION: Direct fixation of posterior malleolar fractures through a posterolateral approach showed good clinical mid- to long-term results with a high satisfaction rate but substantial development of posttraumatic ankle osteoarthritis. Further studies should include CT analysis of the preoperative fracture morphology and even, perhaps, the postoperative reduction accuracy to evaluate the benefit of posterior malleolar fracture reduction in preventing ankle osteoarthritis in the long term. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for authors for a complete description of levels of evidence.


Assuntos
Fraturas do Tornozelo , Fixação Interna de Fraturas , Adulto , Idoso , Idoso de 80 Anos ou mais , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...