Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Sci Rep ; 14(1): 21882, 2024 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-39300151

RESUMO

Hypertension is a significant contributor to premature mortality, and the regular monitoring of blood pressure (BP) enables the early detection of hypertension and cardiovascular disease. There is an urgent need for the development of highly accurate cuffless BP devices. We examined BP measurements based on a target spectral camera's recordings and evaluated their accuracy. Images of 215 adults' palms and faces were recorded, and BP was measured. The camera captured RGB wavelength data at 640 × 480 pixels and 150 frames per second (fps). These recordings were analyzed to extract pulse transit time (PTT) values between the face and palm, a key parameter for estimating BP. Continuous BP measurements were taken using a CNAPmonitor500 for validation. Three frequency wavelengths were measured from video images. A machine learning model was constructed to determine hypertension, defined as a systolic BP of 130 mmHg or higher or a diastolic BP of 80 mmHg or higher, using the visualized data. The discrimination between hypertension and normal BP was 95.0% accurate within 30 s and 90.3% within 5 s, based on the captured images. The results of heartbeat-by-heartbeat analyses can be used to determine hypertension based on only one second of camera footage or one heartbeat. The data extracted from a video recorded by a target spectral camera enabled accurate hypertension diagnoses, suggesting the potential for simplified BP monitoring.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Estudos Prospectivos , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea , Idoso , Análise de Onda de Pulso/métodos , Aprendizado de Máquina , Frequência Cardíaca , Adulto Jovem
3.
J Cardiol Cases ; 29(6): 244-247, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38826767

RESUMO

Patients with congenitally corrected transposition of the great arteries (ccTGA) often develop complete atrioventricular block and heart failure due to the abnormal disposition of atrioventricular node and disadvantage of systemic right ventricle. These issues are managed with a pacing system and a ventricular assist device (VAD), respectively. While technological advances offer new treatment strategies, the simultaneous deployment of a leadless pacemaker and a VAD in cases of ccTGA remains unexplored. Here, we present a case of leadless pacemaker implantation for a VAD-supported ccTGA patient. The safety of a leadless pacemaker for a subpulmonary left ventricle and electromagnetic interference between devices are major concerns when implanting a leadless pacemaker; however, the current case overcomes these obstacles. There were no perioperative complications, and both devices were functioning without problems during a one-year follow up. We expect that, even in patients with cardiac complexity such as systemic right ventricle under VAD support, a leadless pacemaker could become the treatment of choice if the indication is appropriate, although careful and close follow up is needed. Learning objective: Technological advances expand treatment strategies and provide significant benefits to patients with adult congenital heart disease (ACHD). However, discussion of the combination of a leadless pacemaker and a ventricular assist device (VAD) is rare. We demonstrated the efficacy of a leadless pacemaker for a subpulmonary left ventricle in a patient with systemic right ventricle on VAD. This approach could be an option even for ACHD patients.

4.
JACC Adv ; 3(6): 100973, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38938865

RESUMO

Background: Emerging evidence suggests a pathophysiological link between obesity and atrial fibrillation (AF). However, the contribution of body fat distribution to left atrial (LA) remodeling and its reversibility remain unclear in nonobese AF patients. Objectives: The purpose of this study was to investigate the association of body fat distribution with LA size and reverse remodeling (LARR). Methods: In total, 116 nonobese patients with AF (88 men, age 63 ± 11 years) who underwent first catheter ablation (CA) were included. Body fat distribution was assessed with bioelectrical impedance, and body fat percentage (BF%) and central fat percentage (CF%) were calculated. Patients were categorized by body size metrics (body mass index [BMI] and waist-to-hip [W/H] ratio) and fat parameters (BF% and CF%). Echocardiography was performed before and 6 months after CA. Multivariable logistic regression was used to examine the association between the 4 metrics (ie, BMI, W/H ratio, BF%, and CF%) and a lack of LARR (<15% reduction or increase in the LA volume index). Results: Body size metrics and adiposity measures were not independently associated with baseline LA size. Six months after CA, the higher W/H ratio and CF% groups exhibited persistent LA enlargement compared to their counterparts (both P < 0.01). In the multivariable analysis, W/H ratio and CF% were associated with a lack of LARR (adjusted ORs of 3.86 and 2.81 per 0.10 and 10% increase, respectively, both P < 0.01). The combined assessment of CF% with W/H ratio provided complementary risk stratification for persistent LA enlargement. Conclusions: Central adiposity was associated with a lack of LARR after CA, highlighting the importance of assessing body fat distribution even in nonobese patients.

5.
Sci Immunol ; 9(95): eade3814, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38787963

RESUMO

Patients with heart failure (HF) often experience repeated acute decompensation and develop comorbidities such as chronic kidney disease and frailty syndrome. Although this suggests pathological interaction among comorbidities, the mechanisms linking them are poorly understood. Here, we identified alterations in hematopoietic stem cells (HSCs) as a critical driver of recurrent HF and associated comorbidities. Bone marrow transplantation from HF-experienced mice resulted in spontaneous cardiac dysfunction and fibrosis in recipient mice, as well as increased vulnerability to kidney and skeletal muscle insults. HF enhanced the capacity of HSCs to generate proinflammatory macrophages. In HF mice, global chromatin accessibility analysis and single-cell RNA-seq showed that transforming growth factor-ß (TGF-ß) signaling was suppressed in HSCs, which corresponded with repressed sympathetic nervous activity in bone marrow. Transplantation of bone marrow from mice in which TGF-ß signaling was inhibited similarly exacerbated cardiac dysfunction. Collectively, these results suggest that cardiac stress modulates the epigenome of HSCs, which in turn alters their capacity to generate cardiac macrophage subpopulations. This change in HSCs may be a common driver of repeated HF events and comorbidity by serving as a key carrier of "stress memory."


Assuntos
Insuficiência Cardíaca , Imunidade Inata , Memória Imunológica , Camundongos Endogâmicos C57BL , Animais , Insuficiência Cardíaca/imunologia , Camundongos , Masculino , Multimorbidade , Fator de Crescimento Transformador beta/metabolismo , Células-Tronco Hematopoéticas/imunologia , Transdução de Sinais/imunologia , Macrófagos/imunologia , Imunidade Treinada
6.
Sci Rep ; 14(1): 6916, 2024 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519537

RESUMO

Risk factors for pacemaker-induced cardiomyopathy (PICM) have been previously reported, including a high burden of right ventricular pacing, lower left ventricular ejection fraction, a wide QRS duration, and left bundle branch block before pacemaker implantation (PMI). However, predicting the development of PICM remains challenging. This study aimed to use a convolutional neural network (CNN) model, based on clinical findings before PMI, to predict the development of PICM. Out of a total of 561 patients with dual-chamber PMI, 165 (mean age 71.6 years, 89 men [53.9%]) who underwent echocardiography both before and after dual-chamber PMI were enrolled. During a mean follow-up period of 1.7 years, 47 patients developed PICM. A CNN algorithm for prediction of the development of PICM was constructed based on a dataset prior to PMI that included 31 variables such as age, sex, body mass index, left ventricular ejection fraction, left ventricular end-diastolic diameter, left ventricular end-systolic diameter, left atrial diameter, severity of mitral regurgitation, severity of tricuspid regurgitation, ischemic heart disease, diabetes mellitus, hypertension, heart failure, New York Heart Association class, atrial fibrillation, the etiology of bradycardia (sick sinus syndrome or atrioventricular block) , right ventricular (RV) lead tip position (apex, septum, left bundle, His bundle, RV outflow tract), left bundle branch block, QRS duration, white blood cell count, haemoglobin, platelet count, serum total protein, albumin, aspartate transaminase, alanine transaminase, estimated glomerular filtration rate, sodium, potassium, C-reactive protein, and brain natriuretic peptide. The accuracy, sensitivity, specificity, and area under the curve of the CNN model were 75.8%, 55.6%, 83.3% and 0.78 respectively. The CNN model could accurately predict the development of PICM using clinical findings before PMI. This model could be useful for screening patients at risk of developing PICM, ensuring timely upgrades to physiological pacing to avoid missing the optimal intervention window.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Masculino , Humanos , Idoso , Volume Sistólico , Bloqueio de Ramo/terapia , Bloqueio de Ramo/complicações , Função Ventricular Esquerda , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Marca-Passo Artificial/efeitos adversos , Arritmias Cardíacas/etiologia , Redes Neurais de Computação
7.
Cardiol Young ; : 1-3, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38444231

RESUMO

We experienced the first case of a difficult-to-extract central venous catheter removed with a pacemaker lead removal system: a 14-year-old boy with Hirschsprung's disease who had repeated catheter infections that could not be removed by traction. Because the catheter lumen was occluded, a suture was tied around the end of the catheter and the catheter was removed with a rotating dilator.

8.
Comput Methods Programs Biomed ; 247: 108097, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428250

RESUMO

BACKGROUND AND OBJECTIVE: Left ventricular hypertrophy (LVH) can impair ejection function and elevate the risk of heart failure. Therefore, early detection through screening is crucial. This study aimed to propose a novel method to enhance LVH detection using 12-lead electrocardiogram (ECG) waveforms with a two-dimensional (2D) convolutional neural network (CNN). METHODS: Utilizing 42,127 pairs of ECG-transthoracic echocardiogram data, we pre-processed raw data into single-shot images derived from each ECG lead and conducted lead selection to optimize LVH diagnosis. Our proposed one-shot screening method, implemented during pre-processing, enables the superimposition of waveform source data of any length onto a single-frame image, thereby addressing the limitations of the one-dimensional (1D) approach. We developed a deep learning model with a 2D-CNN structure and machine learning models for LVH detection. To assess our method, we also compared our results with conventional ECG criteria and those of a prior study that used a 1D-CNN approach, utilizing the same dataset from the University of Tokyo Hospital for LVH diagnosis. RESULTS: For LVH detection, the average area under the receiver operating characteristic curve (AUROC) was 0.916 for the 2D-CNN model, which was significantly higher than that obtained using logistic regression and random forest methods, as well as the two conventional ECG criteria (AUROC of 0.766, 0.790, 0.599, and 0.622, respectively). Incorporating additional metadata, such as ECG measurement data, further improved the average AUROC to 0.921. The model's performance remained stable across two different annotation criteria and demonstrated significant superiority over the performance of the 1D-CNN model used in a previous study (AUROC of 0.807). CONCLUSIONS: This study introduces a robust and computationally efficient method that outperforms 1D-CNN models utilized in previous studies for LVH detection. Our method can transform waveforms of any length into fixed-size images and leverage the selected lead of the ECG, ensuring adaptability in environments with limited computational resources. The proposed method holds promise for integration into clinical practice as a tool for early diagnosis, potentially enhancing patient outcomes by facilitating earlier treatment and management.


Assuntos
Eletrocardiografia , Hipertrofia Ventricular Esquerda , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Eletrocardiografia/métodos , Ecocardiografia , Redes Neurais de Computação , Programas de Rastreamento
9.
Pacing Clin Electrophysiol ; 47(1): 127-130, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38055652

RESUMO

BACKGROUND: Using third-party resources to manage remote monitoring (RM) data from implantable cardiac electronic devices (CIEDs) can assist in device clinic workflows. However, each hospital-acquired data is not used for further analysis as big data. METHODS AND RESULTS: We developed a real-time and automatically centralized system of CIED information from multiple hospitals. If the extensive data-based analysis suggests individual problems, it can be returned to each hospital. To show its feasibility, we prospectively analyzed data from six hospitals. For example, unexpected abnormal battery levels were easily illustrated without recall information. CONCLUSIONS: The centralized RM system could be a new platform that promotes the utilization of device data as big data, and that information could be used for each patient's practice.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Tecnologia de Sensoriamento Remoto/métodos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Monitorização Fisiológica/métodos
10.
J Am Heart Assoc ; 13(1): e032215, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38156556

RESUMO

BACKGROUND: Atrial fibrillation (AF) progression is closely related to heart failure occurrence, and catheter ablation carries a beneficial effect for heart failure prevention. Recently, particular attention has been given to left atrial (LA) function and functional reserve in the pathogenesis linking AF and heart failure, although its significance and reversibility is not well studied. METHODS AND RESULTS: We prospectively investigated 164 patients with AF with normal left ventricular systolic function and free from heart failure who underwent first catheter ablation and pre-/postprocedural echocardiography. Conventional and speckle-tracking echocardiography were performed at rest and during passive leg lifting to assess LA size, LA reservoir strain (LARS), and functional reserve calculated as passive leg lifting-LARS - rest-LARS. Patients were categorized into 3 AF subtypes: paroxysmal AF (N=95), persistent AF (PeAF; N=50), and long-standing persistent AF (LS-PeAF; N=19). The PeAF and LS-PeAF groups had larger LA size and reduced LARS compared with the paroxysmal AF group (all P<0.05). LA functional reserve was significantly impaired in the LS-PeAF group (P=0.003). In multivariable analysis, LS-PeAF and advanced age were significantly associated with impaired LA functional reserve. Among 149 patients with sinus rhythm 1 to 2 days after catheter ablation, LARS was significantly improved in both PeAF and LS-PeAF groups but was still lower than that in the paroxysmal AF group. Sinus rhythm restoration also led to amelioration of LA functional reserve in patients with LS-PeAF. CONCLUSIONS: AF progression was related to impaired LARS and LA functional reserve, and restoration of sinus rhythm might contribute to early LA reverse remodeling.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Átrios do Coração , Apêndice Atrial/cirurgia , Ecocardiografia/métodos , Ablação por Cateter/métodos , Resultado do Tratamento
11.
Medicine (Baltimore) ; 102(46): e35991, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37986317

RESUMO

Atrial fibrillation (AF) is the most common arrhythmia and a major public health burden. Catheter ablation (CA) is an effective treatment of AF. Although radiofrequency catheter ablation (RFCA) is the standard practice, cryoballoon ablation (CBA) has become increasingly popular. Pulmonary dysfunction is also associated with AF. As CA targets the pulmonary vasculature, it poses a risk to lung function. However, the effect of CA on respiration in patients with paroxysmal atrial fibrillation (PAF) post-ablation has not yet been assessed. We assessed pulmonary function after CA in a cohort of patients with AF. This prospective, single-center study included 26 patients with symptomatic PAF and 18 patients without PAF. CA techniques include RFCA, CBA, hot balloon ablation, and laser balloon-mediated ablation. Spirometry parameters included vital capacity (VC), forced vital capacity (FVC), forced expiratory volume (FEV1), and peak expiratory flow, which were all measured 6 months post-ablation. AF ablation significantly improved VC (P = .04), FVC (P = .01), and peak expiratory flow (P = .006) in all the patients. In the patients with PAF, we observed a significant increase in FEV1 (P = .04). CBA significantly improved VC (P = .012) and FVC (P = .013). A significant improvement in these pulmonary parameters was achieved, specifically in patients with PAF treated with an ablation protocol with CBA, but not with RFCA or hot balloon ablation. A significant decrease in FEV1 was observed with hot balloon ablation (P = .035). Significant improvement in pulmonary parameters was observed specifically in patients with PAF who underwent CBA. CBA may be a more suitable treatment strategy for patients with PAF, particularly those with compromised pulmonary function.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/complicações , Criocirurgia/métodos , Estudos Prospectivos , Resultado do Tratamento , Pulmão/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
12.
Sci Rep ; 13(1): 16514, 2023 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-37783787

RESUMO

Clinical predictors for pacemaker-induced cardiomyopathy (PICM) (e.g., a wide QRS duration and left bundle branch block at baseline) have been reported. However, factors involved in the development of PICM in patients with preserved left ventricular ejection fraction (LVEF) remain unknown. This study aimed to determine the risk factors for PICM in patients with preserved LVEF. The data of 113 patients (average age: 71.3 years; men: 54.9%) who had echocardiography before and after pacemaker implantation (PMI) among 465 patients undergoing dual-chamber PMI were retrospectively analyzed. Thirty-three patients were diagnosed with PICM (18.0/100 person-years; 95% CI 12.8-25.2). A univariate Cox regression analysis showed that an estimated glomerular filtration rate (eGFR) ≤ 30 mL/min/1.73 m2 (HR 3.47; 95% CI 1.48-8.16) and a past medical history of coronary artery disease (CAD) (HR 2.76; 95% CI 1.36-5.60) were significantly associated with the onset of PICM. After adjusting for clinical variables, an eGFR ≤ 30 mL/min/1.73 m2 (HR 2.62; 95% CI 1.09-6.29) and a medical history of CAD (HR 2.32; 95% CI 1.13-4.80) were independent risk factors for developing PICM. A medical history of CAD and low eGFR are independent risk factors for PICM in patients with preserved LVEF at baseline. These results could be helpful in predicting a decreased LVEF by ventricular pacing before PMI. Close follow-up by echocardiography is recommended to avoid a delay in upgrading to physiological pacing, such as cardiac resynchronization therapy or conduction system pacing.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Masculino , Humanos , Idoso , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Estudos Retrospectivos , Taxa de Filtração Glomerular , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Resultado do Tratamento
13.
J Am Heart Assoc ; 12(18): e030325, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37702280

RESUMO

Background Elevated left atrial (LA) pressure predisposes individuals to the initiation and persistence of atrial fibrillation (AF), and LA hypertension is associated with AF recurrence after catheter ablation (CA). However, the exact frequency and factors associated with LA hypertension are unknown, and its noninvasive estimation is challenging. This study aimed to investigate the prevalence and determinants of LA hypertension in patients with AF who underwent first CA. Methods and Results We examined 183 patients with AF who underwent conventional and speckle-tracking echocardiography before CA to assess LA size, reservoir strain, and stiffness. Direct LA pressure was measured at the time of CA, and LA hypertension was defined as mean LA pressure >15 mm Hg. Thirty-three (18.0%) patients exhibited LA hypertension. Patients with LA hypertension had a significantly larger LA volume index (40.2 [28.4-52.1] versus 34.1 [26.9-42.4] mL/m2, P=0.025), reduced LA reservoir strain (15.1 [10.4-21.7] versus 22.7 [14.4-32.3] %, P=0.002) and increased LA stiffness (0.69 [0.34-0.99] versus 0.36 [0.24-0.54], P<0.001). Multivariable analyses showed that waist circumference, C-reactive protein level, LA reservoir strain, and LA stiffness were independently associated with LA hypertension (all P<0.05), while LA volume and E/e' ratio were not. Among echocardiographic parameters, receiver operating characteristic curve analysis identified LA stiffness as the best predictor of LA hypertension. Conclusions Approximately 20% of patients with AF who underwent CA had LA hypertension. Central obesity and inflammation might be involved in the pathophysiological mechanisms of LA hypertension, and echocardiography-derived LA stiffness may have clinical utility for the detection of LA hypertension before CA.


Assuntos
Fibrilação Atrial , Hipertensão , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Prevalência , Átrios do Coração/diagnóstico por imagem , Ecocardiografia , Hipertensão/diagnóstico , Hipertensão/epidemiologia
14.
Europace ; 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37155360

RESUMO

AIMS: To investigate the exact prevalence of glucose metabolism disorders, and their impact on left atrial (LA) remodelling and reversibility in patients with atrial fibrillation (AF). METHODS AND RESULTS: We examined 204 consecutive patients with AF who underwent their first catheter ablation (CA). Oral glucose tolerance test was used to evaluate glucose metabolism disorders in 157 patients without known diabetes mellitus (DM). Echocardiography was performed before and 6 months after CA. Oral glucose tolerance test identified abnormal glucose metabolism in 86 patients [11 with newly diagnosed DM, 74 with impaired glucose tolerance (IGT) and 1 with impaired fasting glucose (IFG)]. Ultimately, 65.2% of patients had abnormal glucose metabolism. Diabetes mellitus group had the worst LA reservoir strain and LA stiffness (both P < 0.05), while there was no significant difference in baseline LA parameters between normal glucose tolerance (NGT) group and IGT/IFG group. The prevalence of LA reverse remodelling (≥15% decrease in the LA volume index at 6 months after CA) was significantly higher in NGT group compared with IGT/IFG and DM group (64.1 vs. 38.6 vs. 41.5%, P = 0.006). Both DM and IFG/IGT carry a significant risk of lack of LA reverse remodelling independent of baseline LA size and AF recurrence. CONCLUSION: Approximately 65% of patients with AF who underwent their first CA had abnormal glucose metabolism. Patients with DM had significantly impaired LA function compared with non-DM patients. Impaired glucose tolerance/IFG as well as DM carries significant risk of unfavourable LA reverse remodelling. Our observations may provide valuable information regarding the mechanisms and therapeutic strategies of glucose metabolism-related AF.

16.
Int Heart J ; 63(3): 486-491, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35650150

RESUMO

Asymptomatic or silent atrial fibrillation (AF) has long been a clinical problem due to the incidence of ischemic stroke. A method is needed to predict the development of silent AF before the occurrence of ischemic stroke. This study was focused on the symptoms of AF, especially palpitation, in pacemaker patients. We assessed the hypothesis that absence of palpitation during rapid ventricular pacing could be a predictor of future onset AF being asymptomatic.In this study, we assessed the presence of symptoms during RV pacing and AF symptoms on 145 pacemaker patients at the outpatient clinic by VVI pacing at 120 ppm. The relationship between symptoms during RV pacing and symptom during AF was assessed. The predictive value of absence of symptom during RV pacing on AF being asymptomatic was assessed.Of 145 patients, 74 had previous AF episode. Among the AF patients, absence of symptom during VVI pacing was associated with AF being asymptomatic.Of 145 patients, 71 had no previous AF events. There were 14 patients who had new-onset AF or atrial flutter (AFL) after the device implantation. Four of the 14 patients (28.6%) were symptomatic during first AF/AFL episode, and 10 (71.4%) were asymptomatic during first-onset AF. All ten patients who were asymptomatic during cardiac pacing test were asymptomatic during their initial episodes of AF as well.This study showed that absence of symptoms during rapid ventricular pacing was associated with first-onset AF being asymptomatic.


Assuntos
Fibrilação Atrial , Flutter Atrial , AVC Isquêmico , Marca-Passo Artificial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Flutter Atrial/complicações , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Humanos , Marca-Passo Artificial/efeitos adversos
17.
Circ Rep ; 3(9): 481-487, 2021 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-34568626

RESUMO

Background: In patients undergoing catheter ablation (CA) for atrial fibrillation (AF), the use of uninterrupted direct oral anticoagulants (DOACs) is the current protocol. This study evaluated bleeding complications following the uninterrupted use of 4 DOACs in patients undergoing CA for AF without any change in the dosing regimen. Moreover, we assessed differences between once- and twice-daily DOAC dosing in patients undergoing CA for AF who continued on DOACs without any change in the dosing regimen. Methods and Results: This study was a retrospective single-center cohort study of consecutive patients. All patients continued DOACs without interruption or changes to the dosing schedule, even in the case of morning procedures. The primary endpoint was the incidence of major bleeding events within the first 30 days after CA. In all, 710 consecutive patients were included in the study. Bleeding complications were less frequent in the uninterrupted twice- than once-daily DOACs group. However, the incidence of cardiac tamponade across all DOACs was low (0.98%; 7/710), suggesting that uninterrupted DOACs without changes to the dosing regimen may be an acceptable strategy. The rate of total bleeding events, including minor bleeding (12/710; 1.6%), was also satisfactory. Conclusions: Uninterrupted DOACs without any change in dosing regimen for patients undergoing CA for AF is acceptable. Bleeding complications may be less frequent in patients receiving DOACs twice rather than once daily.

18.
J Cardiovasc Electrophysiol ; 32(8): 2329-2332, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34164865

RESUMO

Parallel connection of an electrophysiology recording system (EP system) to equipment for conduction system pacing (CSP) has been widely used for fine monitoring of intracardiac electrograms and pacing evaluation. We experienced a case showing unexpected pacing threshold exacerbation under specific conditions when the EP system was connected in parallel. We evaluated the underlying mechanism using an ex vivo model. An ex vivo pacing and intracardiac electrogram monitoring model was generated using an oscilloscope, pacing system analyzer (PSA), EP system, and simulated heart. The discrepancy between expected output at the PSA and the actual measured output value at the simulated heart was measured under various conditions and using various combinations of pacing equipment. Parallel connection of the EP system was associated with reduced electrical output from the PSA as recorded at the simulated heart. The unexpected adverse effects were particularly noticeable when using an RMC-5000 EP system with the pacing function on. The trouble is completely resolved by simply turning off the pacing function of the system. There is a possibility that the EP system might increase the pacing threshold in CSP when the PSA and EP system is are deployed in parallel. The issue may provoke pseudo failure of CSP due to the high pacing threshold. When the RMC-5000 is used for conduction system pacing in parallel with a PSA for the pacing test, the pacing function of RMC-5000 should be turned off.


Assuntos
Fascículo Atrioventricular , Técnicas Eletrofisiológicas Cardíacas , Estimulação Cardíaca Artificial , Eletrocardiografia , Sistema de Condução Cardíaco , Humanos
19.
Nat Commun ; 12(1): 1910, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33771995

RESUMO

Cardiac arrhythmias are a primary contributor to sudden cardiac death, a major unmet medical need. Because right ventricular (RV) dysfunction increases the risk for sudden cardiac death, we examined responses to RV stress in mice. Among immune cells accumulated in the RV after pressure overload-induced by pulmonary artery banding, interfering with macrophages caused sudden death from severe arrhythmias. We show that cardiac macrophages crucially maintain cardiac impulse conduction by facilitating myocardial intercellular communication through gap junctions. Amphiregulin (AREG) produced by cardiac macrophages is a key mediator that controls connexin 43 phosphorylation and translocation in cardiomyocytes. Deletion of Areg from macrophages led to disorganization of gap junctions and, in turn, lethal arrhythmias during acute stresses, including RV pressure overload and ß-adrenergic receptor stimulation. These results suggest that AREG from cardiac resident macrophages is a critical regulator of cardiac impulse conduction and may be a useful therapeutic target for the prevention of sudden death.


Assuntos
Anfirregulina/fisiologia , Arritmias Cardíacas/complicações , Morte Súbita Cardíaca/prevenção & controle , Macrófagos/fisiologia , Miocárdio/metabolismo , Anfirregulina/metabolismo , Animais , Animais Recém-Nascidos , Células Cultivadas , Morte Súbita Cardíaca/etiologia , Feminino , Junções Comunicantes/fisiologia , Células HeLa , Humanos , Macrófagos/metabolismo , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Miocárdio/citologia , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/fisiologia , Receptores Adrenérgicos beta/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA