Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 10(2)2019 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-30823547

RESUMO

We report a change of the imaging biomarker distribution of circulating tumor cell (CTC) clusters in blood over time using an on-chip multi-imaging flow cytometry system, which can obtain morphometric parameters of cells and those clusters, such as cell number, perimeter, total cross-sectional area, aspect ratio, number of nuclei, and size of nuclei, as "imaging biomarkers". Both bright-field (BF) and fluorescent (FL) images were acquired at 200 frames per second and analyzed within the intervals for real-time cell sorting. A green fluorescent protein-transfected prostate cancer cell line (MAT-LyLu-GFP) was implanted into Copenhagen rats, and the blood samples of these rats were collected 2 to 11 days later and measured using the system. The results showed that cells having BF area of 90 µm² or larger increased in number seven days after the cancer cell implantation, which was specifically detected as a shift of the cell size distribution for blood samples of implanted rats, in comparison with that for control blood. All cells with BF area of 150 µm² or larger were arranged in cell clusters composed of at least two cells, as confirmed by FL nucleus number and area measurements, and they constituted more than 1% of all white blood cells. These results indicate that the mapping of cell size distribution is useful for identifying an increase of irregular cells such as cell clusters in blood, and show that CTC clusters become more abundant in blood over time after malignant tumor formation. The results also reveal that a blood sample of only 50 µL is sufficient to acquire a stable size distribution map of all blood cells to predict the presence of CTC clusters.

2.
Sci Rep ; 8(1): 14536, 2018 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-30266924

RESUMO

We examined a simultaneous combined spatiotemporal field potential duration (FPD) and cell-to-cell conduction time (CT) in lined-up shaped human embryonic stem cell-derived cardiomyocytes (hESC-CMs) using an on-chip multielectrode array (MEA) system to evaluate two origins of lethal arrhythmia, repolarization and depolarization. The repolarization index, FPD, was prolonged by E-4031 and astemizole, and shortened by verapamil, flecainide and terfenadine at 10 times higher than therapeutic plasma concentrations of each drug, but it did not change after lidocaine treatment up to 100 µM. CT was increased by astemizol, flecainide, terfenadine, and lidocaine at equivalent concentrations of Nav1.5 IC50, suggesting that CT may be an index of cardiac depolarization because the increase in CT (i.e., decrease in cell-to-cell conduction speed) was relevant to Nav1.5 inhibition. Fluctuations (short-term variability; STV) of FPD and CT, STVFPD and STVCT also discriminated between torsadogenic and non-torsadogenic compounds with significant increases in their fluctuation values, enabling precise prediction of arrhythmogenic risk as potential new indices.


Assuntos
Arritmias Cardíacas/tratamento farmacológico , Avaliação Pré-Clínica de Medicamentos/instrumentação , Dispositivos Lab-On-A-Chip , Miócitos Cardíacos/efeitos dos fármacos , Linhagem Celular , Desenvolvimento de Medicamentos/instrumentação , Desenho de Equipamento , Células-Tronco Embrionárias Humanas/citologia , Humanos , Miócitos Cardíacos/citologia
3.
Sci Rep ; 7: 40072, 2017 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-28059147

RESUMO

A microfluidic on-chip imaging cell sorter has several advantages over conventional cell sorting methods, especially to identify cells with complex morphologies such as clusters. One of the remaining problems is how to efficiently discriminate targets at the species level without labelling. Hence, we developed a label-free microfluidic droplet-sorting system based on image recognition of cells in droplets. To test the applicability of this method, a mixture of two plankton species with different morphologies (Dunaliella tertiolecta and Phaeodactylum tricornutum) were successfully identified and discriminated at a rate of 10 Hz. We also examined the ability to detect the number of objects encapsulated in a droplet. Single cell droplets sorted into collection channels showed 91 ± 4.5% and 90 ± 3.8% accuracy for D. tertiolecta and P. tricornutum, respectively. Because we used image recognition to confirm single cell droplets, we achieved highly accurate single cell sorting. The results indicate that the integrated method of droplet imaging cell sorting can provide a complementary sorting approach capable of isolating single target cells from a mixture of cells with high accuracy without any staining.


Assuntos
Separação Celular/métodos , Forma Celular , Microfluídica/métodos , Imagem Óptica/métodos , Separação Celular/instrumentação , Diatomáceas/citologia , Diatomáceas/isolamento & purificação , Volvocida/citologia
4.
Cytometry A ; 89(8): 731-41, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27111676

RESUMO

Recent advances in imaging flow cytometry and microfluidic applications have led to the development of suitable mathematical algorithms capable of detecting and identifying targeted cells in images. In contrast to currently existing algorithms, we herein proposed the identification and reconstruction of cell edges based on original approaches that overcome frequent detection limitations such as halos, noise, and droplet boundaries in microfluidic applications. Reconstructed cells are then discriminated between single cells and clusters of round-shaped cells, and cell information such as the area and location of a cell in an image is output. Using this method, 76% of cells detected in an image had an error <5% of the cell area size and 41% of the image had an error <1% of the cell area size (n = 1,000). The method developed in the present study is the first image processing algorithm designed to be flexible in use (i.e. independent of the size of an image, using a microfluidic droplet system or not, and able to recognize cell clusters in an image) and provides the scientific community with a very accurate imaging algorithm in the field of microfluidic applications. © 2016 International Society for Advancement of Cytometry.


Assuntos
Citometria de Fluxo/métodos , Processamento de Imagem Assistida por Computador/métodos , Técnicas Analíticas Microfluídicas/métodos , Algoritmos , Agregação Celular/genética , Humanos , Imageamento Tridimensional/métodos , Análise de Célula Única/métodos
5.
PLoS One ; 9(8): e104372, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25140522

RESUMO

An on-chip multi-imaging flow cytometry system has been developed to obtain morphometric parameters of cell clusters such as cell number, perimeter, total cross-sectional area, number of nuclei and size of clusters as "imaging biomarkers", with simultaneous acquisition and analysis of both bright-field (BF) and fluorescent (FL) images at 200 frames per second (fps); by using this system, we examined the effectiveness of using imaging biomarkers for the identification of clustered circulating tumor cells (CTCs). Sample blood of rats in which a prostate cancer cell line (MAT-LyLu) had been pre-implanted was applied to a microchannel on a disposable microchip after staining the nuclei using fluorescent dye for their visualization, and the acquired images were measured and compared with those of healthy rats. In terms of the results, clustered cells having (1) cell area larger than 200 µm2 and (2) nucleus area larger than 90 µm2 were specifically observed in cancer cell-implanted blood, but were not observed in healthy rats. In addition, (3) clusters having more than 3 nuclei were specific for cancer-implanted blood and (4) a ratio between the actual perimeter and the perimeter calculated from the obtained area, which reflects a shape distorted from ideal roundness, of less than 0.90 was specific for all clusters having more than 3 nuclei and was also specific for cancer-implanted blood. The collected clusters larger than 300 µm2 were examined by quantitative gene copy number assay, and were identified as being CTCs. These results indicate the usefulness of the imaging biomarkers for characterizing clusters, and all of the four examined imaging biomarkers-cluster area, nuclei area, nuclei number, and ratio of perimeter-can identify clustered CTCs in blood with the same level of preciseness using multi-imaging cytometry.


Assuntos
Biomarcadores Tumorais/análise , Citometria de Fluxo/métodos , Células Neoplásicas Circulantes/patologia , Neoplasias da Próstata/diagnóstico , Animais , Linhagem Celular Tumoral , Diagnóstico por Imagem , Masculino , Neoplasias da Próstata/patologia , Ratos
6.
PLoS One ; 7(8): e42485, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22870332

RESUMO

A non-destructive method of collecting cultured cells after identifying their in situ functional characteristics is proposed. In this method, cells are cultivated on an alginate layer in a culture dish and released by spot application of a calcium chelate buffer that locally melts the alginate layer and enables the collection of cultured cells at the single-cell level. Primary hippocampal neurons, beating human embryonic stem (hES) cell-derived cardiomyocytes, and beating hES cell-derived cardiomyocyte clusters cultivated on an alginate layer were successfully released and collected with a micropipette. The collected cells were recultured while maintaining their physiological function, including beating, and elongated neurites. These results suggest that the proposed method may eventually facilitate the transplantation of ES- or iPS-derived cardiomyocytes and neurons differentiated in culture.


Assuntos
Alginatos/química , Células-Tronco Embrionárias/citologia , Hipocampo/citologia , Miócitos Cardíacos/citologia , Neuritos , Animais , Técnicas de Cultura de Células/métodos , Células Cultivadas , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Humanos , Ratos , Ratos Wistar
7.
Int J Mol Sci ; 13(1): 819-827, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22312288

RESUMO

We have demonstrated the efficacy of a microfluidic medium exchange method for single cells using passive centrifugal force of a rotating microfluidic-chip based platform. At the boundary of two laminar flows at the gathering area of two microfluidic pathways in a Y-shape, the cells were successfully transported from one laminar flow to the other, without mixing the two microfluidic mediums of the two laminar flows during cell transportation, within 5 s with 1 g (150 rpm) to 36.3 g (900 rpm) acceleration, with 93.5% efficiency. The results indicate that this is one of the most simple and precise tools for exchanging medium in the shortest amount of time.


Assuntos
Separação Celular/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Soluções Tampão , Centrifugação , Desenho de Equipamento , Corantes Fluorescentes/química , Células HeLa , Humanos
8.
J Nanobiotechnology ; 9: 39, 2011 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-21929750

RESUMO

BACKGROUNDS: Conventional in vitro approach using human ether-a-go-go related gene (hERG) assay has been considered worldwide as the first screening assay for cardiac repolarization safety. However, it does not always oredict the potential QT prolongation risk or pro-arrhythmic risk correctly. For adaptable preclinical strategiesto evaluate global cardiac safety, an on-chip quasi-in vivo cardiac toxicity assay for lethal arrhythmia (ventricular tachyarrhythmia) measurement using ring-shaped closed circuit microelectrode chip has been developed. RESULTS: The ventricular electrocardiogram (ECG)-like field potential data, which includes both the repolarization and the conductance abnormality, was acquired from the self-convolutied extracellular field potentials (FPs) of a lined-up cardiomyocyte network on a circle-shaped microelectrode in an agarose microchamber. When Astemisol applied to the closed-loop cardiomyocyte network, self-convoluted FP profile of normal beating changed into an early afterdepolarization (EAD) like waveform, and then showed ventricular tachyarrhythmias and ventricular fibrilations (VT/Vf). QT-prolongation-like self-convoluted FP duration prolongation and its fluctuation increase was also observed according to the increase of Astemizole concentration. CONCLUSIONS: The results indicate that the convoluted FPs of the quasi-in vivo cell network assay includes both of the repolarization data and the conductance abnormality of cardiomyocyte networks has the strong potential to prediction lethal arrhythmia.


Assuntos
Astemizol/efeitos adversos , Comunicação Celular/efeitos dos fármacos , Técnicas de Cultura de Células , Antagonistas não Sedativos dos Receptores H1 da Histamina/efeitos adversos , Miócitos Cardíacos/efeitos dos fármacos , Taquicardia Ventricular/induzido quimicamente , Fibrilação Ventricular/induzido quimicamente , Animais , Astemizol/farmacologia , Comunicação Celular/fisiologia , Antagonistas não Sedativos dos Receptores H1 da Histamina/farmacologia , Camundongos , Microeletrodos , Miócitos Cardíacos/fisiologia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/fisiopatologia
9.
Int J Mol Sci ; 12(6): 3618-34, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21747698

RESUMO

We have developed a novel imaging cytometry system using a poly(methyl methacrylate (PMMA)) based microfluidic chip. The system was contamination-free, because sample suspensions contacted only with a flammable PMMA chip and no other component of the system. The transparency and low-fluorescence of PMMA was suitable for microscopic imaging of cells flowing through microchannels on the chip. Sample particles flowing through microchannels on the chip were discriminated by an image-recognition unit with a high-speed camera in real time at the rate of 200 event/s, e.g., microparticles 2.5 µm and 3.0 µm in diameter were differentiated with an error rate of less than 2%. Desired cells were separated automatically from other cells by electrophoretic or dielectrophoretic force one by one with a separation efficiency of 90%. Cells in suspension with fluorescent dye were separated using the same kind of microfluidic chip. Sample of 5 µL with 1 × 10(6) particle/mL was processed within 40 min. Separated cells could be cultured on the microfluidic chip without contamination. The whole operation of sample handling was automated using 3D micropipetting system. These results showed that the novel imaging flow cytometry system is practically applicable for biological research and clinical diagnostics.


Assuntos
Citometria de Fluxo/instrumentação , Animais , Automação , Separação Celular , Corantes Fluorescentes/química , Técnicas Analíticas Microfluídicas/instrumentação , Microscopia de Vídeo , Miócitos Cardíacos/citologia , Polimetil Metacrilato/química
10.
J Nanobiotechnology ; 8: 23, 2010 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-20868509

RESUMO

Regulation of cell cycle progression in changing environments is vital for cell survival and maintenance, and different regulation mechanisms based on cell size and cell cycle time have been proposed. To determine the mechanism of cell cycle regulation in the unicellular green algae Chlamydomonas reinhardtii, we developed an on-chip single-cell cultivation system that allows for the strict control of the extracellular environment. We divided the Chlamydomonas cell cycle into interdivision and division phases on the basis of changes in cell size and found that, regardless of the amount of photosynthetically active radiation (PAR) and the extent of illumination, the length of the interdivision phase was inversely proportional to the rate of increase of cell volume. Their product remains constant indicating the existence of an 'interdivision timer'. The length of the division phase, in contrast, remained nearly constant. Cells cultivated under light-dark-light conditions did not divide unless they had grown to twice their initial volume during the first light period. This indicates the existence of a 'commitment sizer'. The ratio of the cell volume at the beginning of the division phase to the initial cell volume determined the number of daughter cells, indicating the existence of a 'mitotic sizer'.

11.
Drug Metab Dispos ; 35(9): 1502-10, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17537874

RESUMO

2R-gamma-Tocotrienol (gamma-T3) is currently receiving attention because it has beneficial effects not observed with alpha-tocopherol. To achieve the effective delivery of gamma-T3, we synthesized three kinds of ester derivatives of gamma-T3 and evaluated their use as hydrophilic prodrugs for gamma-T3 in vitro and in vivo. 2R-gamma-Tocotrienyl N,N-dimethylamino-acetate hydrochloride (compound 3) was a solid compound, with high solubility and stability in water, and was converted to gamma-T3 by esterases in rat and human liver. Intravenous administration of 3 in rats led to a rapid increase in the plasma, liver, heart, and kidney levels of gamma-T3. The bioavailability (plasma level) after intravenous administration was 82.5 +/- 13.4% and 100 +/- 11.3% for 3 and gamma-T3 in surfactant, respectively, and the availability in liver was 213 +/- 47.6% and 100 +/- 4.8% for 3 and gamma-T3 in surfactant, respectively. Furthermore, the systemic availability of 2,7,8-trimethyl-2S-(beta-carboxyethyl)-6-hydroxychroman (S-gamma-CEHC), a metabolite of gamma-T3, was 78.6% for compound 3, 47.1% for gamma-T3 in surfactant, and 100% for racemic gamma-CEHC. Based on these results, we identified compound 3 as the most promising water-soluble prodrug of gamma-T3 and two-step prodrug of S-gamma-CEHC.


Assuntos
Cromanos/farmacologia , Pró-Fármacos/síntese química , Propionatos/farmacologia , Vitamina E/análogos & derivados , Animais , Área Sob a Curva , Disponibilidade Biológica , Química Farmacêutica , Cromanos/administração & dosagem , Cromanos/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Ésteres/síntese química , Ésteres/farmacologia , Excipientes , Humanos , Hidrólise , Técnicas In Vitro , Microssomos Hepáticos/metabolismo , Óleo de Palmeira , Soluções Farmacêuticas , Fisostigmina/farmacologia , Óleos de Plantas/química , Pró-Fármacos/administração & dosagem , Pró-Fármacos/farmacologia , Propionatos/administração & dosagem , Ratos , Solubilidade , Espectrofotometria Ultravioleta , Tensoativos/farmacologia , Distribuição Tecidual , Vitamina E/administração & dosagem , Vitamina E/isolamento & purificação , Vitamina E/farmacologia
12.
Biochem Biophys Res Commun ; 356(2): 464-9, 2007 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-17350591

RESUMO

Knowing how individual cells respond to environmental changes helps one understand phenotypic diversity in a bacterial cell population, so we simultaneously monitored the growth and motility of isolated motile Escherichia coli cells over several generations by using a method called on-chip single-cell cultivation. Starved cells quickly stopped growing but remained motile for several hours before gradually becoming immotile. When nutrients were restored the cells soon resumed their growth and proliferation but remained immotile for up to six generations. A flagella visualization assay suggested that deflagellation underlies the observed loss of motility. This set of results demonstrates that single-cell transgenerational study under well-characterized environmental conditions can provide information that will help us understand distinct functions within individual cells.


Assuntos
Fenômenos Fisiológicos Bacterianos , Escherichia coli/fisiologia , Flagelos/fisiologia , Meio Ambiente , Fímbrias Bacterianas/fisiologia , Movimento/fisiologia
13.
J Nanobiotechnology ; 2(1): 5, 2004 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-15176978

RESUMO

Studying cell functions for cellomics studies often requires the use of purified individual cells from mixtures of various kinds of cells. We have developed a new non-destructive on-chip cell sorting system for single cell based cultivation, by exploiting the advantage of microfluidics and electrostatic force. The system consists of the following two parts: a cell sorting chip made of poly-dimethylsiloxane (PDMS) on a 0.2-mm-thick glass slide, and an image analysis system with a phase-contrast/fluorescence microscope. The unique features of our system include (i) identification of a target from sample cells is achieved by comparison of the 0.2-microm-resolution phase-contrast and fluorescence images of cells in the microchannel every 1/30 s; (ii) non-destructive sorting of target cells in a laminar flow by application of electrostatic repulsion force for removing unrequited cells from the one laminar flow to the other; (iii) the use of agar gel for electrodes in order to minimize the effect on cells by electrochemical reactions of electrodes, and (iv) pre-filter, which was fabricated within the channel for removal of dust contained in a sample solution from tissue extracts. The sorting chip is capable of continuous operation and we have purified more than ten thousand cells for cultivation without damaging them. Our design has proved to be very efficient and suitable for the routine use in cell purification experiments.

14.
Lab Chip ; 3(4): 292-6, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15007461

RESUMO

We have developed a new method that enables agar microstructures to be used to cultivate cells and that allows cell network patterns to be controlled. The method makes use of non-contact three-dimensional photo-thermal etching with a 1480 nm infrared focused laser beam, which is strongly absorbed by water and agar gel, to form the shapes of agar microstructures. It allows microstructures to be easily formed in an agar layer within a few minutes, with cell-culture holes formed by the spot heating of a 100 mW laser and tunnels by the tracing of a 100 microm s(-1), 40 mW laser. We cultivated rat cardiac myocytes in adjacent microstructures and observed synchronized beating in them 90 min after they had made physical contact. Our results indicate that the system can make and use microstructures for cell-network cultivation in a minimal amount of time without any expensive microfabrication facilities or complicated procedures.


Assuntos
Microcomputadores , Miócitos Cardíacos/química , Ágar , Animais , Animais Recém-Nascidos , Células Cultivadas , Processamento de Imagem Assistida por Computador , Raios Infravermelhos , Lasers , Nanotecnologia , Ratos , Ratos Wistar
15.
J Lipid Res ; 43(12): 2196-204, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12454283

RESUMO

d-gamma-Tocopherol (gamma-Toc) and its major metabolite, 2, 7, 8-trimethyl-2S-(beta-carboxyethyl)-6-hydroxychroman (S-gamma-CEHC), are currently receiving attention concerning their unique pharmacological activities. In order to achieve the efficient delivery of gamma-Toc and S-gamma-CEHC in vivo, we synthesized d-gamma-tocopheryl N,N-dimethylglycinate hydrochloride (gamma-TDMG) as a water-soluble prodrug of gamma-Toc and a two-step prodrug of S-gamma-CEHC. gamma-TDMG is a solid (mp 161-163 degrees C) and is quite soluble in water over 50 mM. The hydrolysis of gamma-TDMG was effectively catalyzed by esterases in rat and human liver microsomes. The disposition of gamma-TDMG after iv administration in rats was compared with that of gamma-Toc solubilized with the surfactant, polyoxyethylene hydrogenated castor oil. The plasma and liver levels of gamma-Toc rapidly increased after the iv administration of the gamma-TDMG. The liver availability of gamma-Toc after the administration of gamma-TDMG was two times higher than that of the gamma-Toc administration. The relative systemic availability of S-gamma-CEHC after the gamma-TDMG administration was an equivalent value (102%), and the mean residence time of S-gamma-CEHC was eight times longer than the racemic gamma-CEHC administration. Based on these results, gamma-TDMG was identified as the most promising water-soluble prodrug of gamma-Toc and the two-step prodrug of S-gamma-CEHC.


Assuntos
Cromanos/metabolismo , Propionatos/metabolismo , gama-Tocoferol/análogos & derivados , Animais , Injeções Intravenosas , Ratos , gama-Tocoferol/química , gama-Tocoferol/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...