Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Radiol Phys Technol ; 17(2): 488-503, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696086

RESUMO

We proposed a new deep learning (DL) model for accurate scatter correction in digital radiography. The proposed network featured a pixel-wise water equivalent path length (WEPL) map of subjects with diverse sizes and 3D inner structures. The proposed U-Net model comprises two concatenated modules: one for generating a WEPL map and the other for predicting scatter using the WEPL map as auxiliary information. First, 3D CT images were used as numerical phantoms for training and validation, generating observed and scattered images by Monte Carlo simulation, and WEPL maps using Siddon's algorithm. Then, we optimised the model without overfitting. Next, we validated the proposed model's performance by comparing it with other DL models. The proposed model obtained scatter-corrected images with a peak signal-to-noise ratio of 44.24 ± 2.89 dB and a structural similarity index measure of 0.9987 ± 0.0004, which were higher than other DL models. Finally, scatter fractions (SFs) were compared with other DL models using an actual phantom to confirm practicality. Among DL models, the proposed model showed the smallest deviation from measured SF values. Furthermore, using an actual radiograph containing an acrylic object, the contrast-to-noise ratio (CNR) of the proposed model and the anti-scatter grid were compared. The CNR of the images corrected using the proposed model are 16% and 82% higher than those of the raw and grid-applied images, respectively. The advantage of the proposed method is that no actual radiography system is required for collecting training dataset, as the dataset is created from CT images using Monte Carlo simulation.


Assuntos
Aprendizado Profundo , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Espalhamento de Radiação , Água , Intensificação de Imagem Radiográfica/métodos , Método de Monte Carlo , Processamento de Imagem Assistida por Computador/métodos , Humanos , Tomografia Computadorizada por Raios X , Algoritmos , Razão Sinal-Ruído , Imageamento Tridimensional
3.
J Funct Biomater ; 15(3)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38535249

RESUMO

The hyoid is the only bone in the human body that is completely independent, not forming a joint with any other bone; its position is maintained by the suprahyoid and infrahyoid muscles, as well as several ligaments. The purpose of this study was to ascertain the effect of the functional pressure arising from these muscles and ligaments on the hyoid body structure from its bone mineral density, bone quality, and histological observations. The area between the mesial-most part of each lesser horn and the center of the hyoid body was divided equally into four measurement regions. We conducted histological investigations at each measurement region and observed the entheses. To analyze bone mass and bone quality, we also measured bone mineral density (BMD) and analyzed biological apatite (BAp) crystallite orientation in the same regions. Histological observations identified periosteal insertions and fibrocartilaginous entheses. There was no significant difference in BMD between any of the measurement regions, but the preferential orientation of BAp crystallites was stronger in the infrahyoid muscles and ligaments, where fibrocartilaginous entheses are found, than in other places. This suggests that the functional pressure at these sites might exert a major effect not only on the morphological characteristics of the entheses but also on bone quality.

4.
Heart Rhythm ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432425

RESUMO

BACKGROUND: A rotational activation pattern (RAP) around the localized line of a conduction block often correlates with sites specific to the critical zones of ventricular tachycardia (VT). The wavefront direction during substrate mapping affects manifestation of the RAP and line of block. OBJECTIVE: The purpose of this study was to investigate the most optimal cardiac rhythm for identifying RAP and line of block in substrate mapping. METHODS: We retrospectively evaluated 71 maps (median 3205 points/map) in 46 patients (65 ± 15 years; 33% with ischemic cardiomyopathy) who underwent high-density substrate mapping and ablation of scar-related VT. Appearance of a RAP during sinus, right ventricular (RV)-paced, left ventricular (LV)-paced, and biventricular-paced rhythms was investigated. RESULTS: RAP was identified in 24 of 71 maps (34%) in the region where wavefronts from a single direction reached but not in the region where wavefronts from multiple directions centripetally collided. The probability of identifying the RAP depended on scar location; that is, anteroseptal and inferoseptal, inferior and apical, and basal lateral RAPs were likely to be identified during sinus/atrial, RV-paced, and LV-paced rhythms, respectively. In 13 patients, the RAP was not evident in the baseline map but became apparent during remapping in the other rhythm, in which the wavefront reached the site earlier within the entire activation time. CONCLUSION: The optimal rhythm for substrate mapping depends on the spatial distribution of the area of interest. A paced rhythm with pacing sites near the scar may facilitate the identification of critical VT zones.

5.
Materials (Basel) ; 16(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37959436

RESUMO

The wear of enamel and crown restorative materials often occur by occlusion. The purpose of this study was to evaluate the wear volume between glass-ceramics used for CAD/CAM blocks (lithium disilicate: Initial LiSi block (LIS), IPS e.max CAD (IPS), zirconia-reinforced lithium silicate glass-ceramics: Celtra DUO (DUO), VITA Suprinity (VITS) and feldspar-based glass-ceramics: Vitablocs Mark II (MAK)) and bovine tooth enamel using a two-body wear test, the hardness, three-point bending strength, micro-structure and the element components of glass-ceramics. The data were analyzed using a one-way analysis of variance and Tukey's multiple comparison test (α = 0.05). IPS and DUO with relatively large size crystal gain had significantly larger abrader wear volumes. Zirconia-reinforced lithium silicate glass-ceramics (DUO, VITS) caused significantly greater wear volume in antagonist enamel. MAK with scale-shape crystals grains produced distinct scratches after wear tests, both in the material itself and in the enamel. A strong correlation between the mechanical properties (hardness, three-point bending strength) and wear volume could not be confirmed. The type of glass-ceramic, size, and shape of the crystal grains affected the wear behavior of the glass-ceramics for CAD/CAM blocks. Therefore, dentists should consider that wear behavior varies with crystal structure, size, and shape in glass-ceramics for CAD/CAM blocks.

6.
Plant Cell Physiol ; 64(11): 1372-1382, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-37930869

RESUMO

Complex structures in living cells and tissues induce wavefront errors when light waves pass through them, and images observed with optical microscopes are undesirably blurred. This problem is especially serious for living plant cells because images are strikingly degraded even within a single cell. Adaptive optics (AO) is expected to be a solution to this problem by correcting such wavefront errors, thus enabling high-resolution imaging. In particular, scene-based AO involves wavefront sensing based on the image correlation between subapertures in a Shack-Hartmann wavefront sensor and thus does not require an intense point light source. However, the complex 3D structures of living cells often cause low correlation between subimages, leading to loss of accuracy in wavefront sensing. This paper proposes a novel method for scene-based sensing using only image correlations between adjacent subapertures. The method can minimize changes between subimages to be correlated and thus prevent inaccuracy in phase estimation. Using an artificial test target mimicking the optical properties of a layer of living plant cells, an imaging performance with a Strehl ratio of approximately 0.5 was confirmed. Upon observation of chloroplast autofluorescence inside living leaf cells of the moss Physcomitrium patens, recovered resolution images were successfully obtained even with complex biological structures. Under bright-field illumination, the proposed method outperformed the conventional method, demonstrating the future potential of this method for label- and damage-free AO microscopy. Several points for improvement in terms of the effect of AO correction are discussed.


Assuntos
Microscopia , Células Vegetais , Microscopia/métodos
7.
J Cardiovasc Electrophysiol ; 34(11): 2262-2272, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37712297

RESUMO

INTRODUCTION: Electrophysiological characteristics of epicardial connections (ECs) in atria and pulmonary veins (PVs) are unclear despite their important contributions to atrial fibrillation (AF). Unidirectional conduction associated with source-sink mismatch can occur in ECs due to their fine fibers with abrupt changes in orientation. We detailed the prevalence and electrophysiological characteristics of unidirectional conduction in the atria and investigated its association with the clinical manifestation of AF. METHODS: This study retrospectively reviewed electrophysiological studies and radiofrequency catheter ablation in 261 consecutive patients with AF. RESULTS: Unidirectional conduction was observed during ablation encircling the PVs in eight (3.1%) patients, and all occurred in the suspected (N = 4) or definitively (N = 4) recognized ECs. These ECs included three intercaval bundles, four septopulmonary bundles, and one Marshall bundle, and were first manifested in a second procedure in 6 (75%) patients. The unidirectional property was from PV to atrium (exit conduction) in all intercaval bundles and three septopulmonary bundles, and from atrium to PV (entrance conduction) in the remaining two bundles. Intercaval bundles acted as a limb of bi-atrial macro-reentrant tachycardia (50%, three of the six including previous cases). Ablation of the exit outside the PVs, including the right atrium, eliminated ECs in three (38%) patients. All patients remain free from arrhythmia recurrence after a mean 13-month follow-up. CONCLUSION: A unidirectional conduction property was closely associated with the EC, as estimated by histological findings. Recognition of this fact by electrophysiologists may help to clarify mechanisms for AF and atrial tachycardia and guide the creation of efficient and safe ablation lesion sets.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Átrios do Coração , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/patologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
9.
J Cardiol Cases ; 27(4): 143-147, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37012927

RESUMO

A 22-year-old woman without structural heart disease underwent catheter ablation of frequent premature atrial contractions (PACs). Radiofrequency applications from both the right and left atrium were effective in suppressing or eliminating these PACs. The distance between the right atrial ablation site and the successful ablation site at the right-sided pulmonary venous carina measured 18 mm on the CARTO map, and no cardiac structure, i.e. the inter-atrial septum, was present between those sites. Taken together, the epicardial muscular fibers in the inter-atrial groove were considered to play a role as an arrhythmogenic source of this atrial tachyarrhythmia. Learning objective: Epicardial muscular fibers connecting the right atrium and right-sided pulmonary venous carina are known to preclude isolation of the veins. This epicardial connection in the interatrial groove can be an arrhythmogenic source or part of a reentrant circuit of atrial tachyarrhythmias.

10.
Sci Rep ; 13(1): 4299, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36922617

RESUMO

Although glucose metabolism and atrial fibrillation (AF) have complex interrelationships, the impact of catheter ablation of AF on glucose status has not been well evaluated. Continuous glucose monitoring (CGM) with a FreeStyle Libre Pro (Abbott) was performed for 48 h pre-procedure, during the procedure, and for 72 h post-procedure in 58 non-diabetes mellitus (DM) patients with symptomatic AF and 20 patients with supraventricular or ventricular arrhythmias as a control group. All ablation procedures including pulmonary vein isolation were performed successfully. Glucose levels during procedures consistently increased in the AF and control groups (83.1 ± 16.1 to 110.0 ± 20.5 mg/dL and 83.3 ± 14.7 to 98.6 ± 16.3 mg/dL, respectively, P < 0.001 for both), and Δ glucose levels (max minus min/procedure) were greater in the AF group than control group (P < 0.001). There was a trend toward higher mean glucose levels at 72 h after the procedures compared with those before the procedures in both the AF and control groups (from 103.4 ± 15.6 to 106.1 ± 13.0 mg/dL, P = 0.063 and from 100.2 ± 17.1 to 102.9 ± 16.9 mg/dL, P = 0.052). An acute increase in glucose level at the time of early AF recurrence (N = 9, 15.5%) could be detected by simultaneous CGM and ECG monitoring (89.7 ± 18.0 to 108.3 ± 30.5 mg/dL, P = 0.001). In conclusion, although AF ablation caused a statistically significant increase in the glucose levels during the procedures, it did not result in a pathologically significant change after ablation in non-DM patients. Simultaneous post-procedure CGM and ECG monitoring alerted us to possible acute increases in glucose levels at the onset of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Automonitorização da Glicemia , Resultado do Tratamento , Glicemia , Ablação por Cateter/métodos , Recidiva
11.
J Prosthodont Res ; 67(3): 460-467, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-36403960

RESUMO

PURPOSE: This study investigates the effects of hollow structures, added by selective laser sintering (SLS), on the mechanical properties of a Co-Cr alloy for providing an optimal structural property to the framework components of removable partial dentures (RPDs). METHODS: The specimens produced using the 3D data of the dumbbell-shaped cylinders were divided into four groups based on the manufacturing method: Cast, Mill, SLS-solid, and SLS-hollow. Tensile tests were performed to measure the mechanical properties of the specimens. The mechanical property values among the four groups were statistically compared using the Kruskal-Wallis test followed by the Steel-Dwass test (α = 0.05). RESULTS: The median elastic modulus was the largest in the Cast, followed by SLS-solid, Mill, and SLS-hollow, with no significant differences observed between all conditions. The median ultimate tensile strength was the largest in the order of SLS-solid, Mill, SLS-hollow, and Cast. The median 0.2% proof stress was the largest in SLS-solid, followed by SLS-hollow, Cast, and Mill. The median elongation was the highest in the order of Mill, SLS-solid, SLS-hollow, and Cast. CONCLUSIONS: With the addition of hollow structures, the elastic modulus decreased while the mechanical strength and proof stress remained high in SLS specimens. In addition, the ISO 22674 standard for dental metals was met, suggesting that SLS may be a possible method to design RPD frameworks with high strength and optimal structural properties.


Assuntos
Ligas de Cromo , Lasers , Ligas de Cromo/química , Ligas Metalo-Cerâmicas/química , Resistência à Tração , Módulo de Elasticidade , Propriedades de Superfície , Teste de Materiais
12.
J Adhes Dent ; 24(1): 435-443, 2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36440831

RESUMO

PURPOSE: This study investigated the effects of mechanical and chemical pretreatment of polyetherketoneketone (PEKK) on shear bond strength (SBS) to root dentin using two types of resin cement. MATERIALS AND METHODS: A total of 100 PEKK specimens were prepared and polished. Sixty specimens were mechanically treated by sandblasting (50-µm Al2O3 for 10 s at 0.2-0.25 MPa), and the remaining 40 were untreated. Self-adhesive resin cement and conventional resin cement were used. PEKK specimens bonded to root dentin using self-adhesive resin cement were classified into three groups by pretreatment method: (1) untreated PEKK, (2) mechanical pretreatment (sandblasted PEKK), and (3) both mechanical and chemical pretreatment (PEKK sandblasting as well as application of Scotchbond Universal; 3M Oral Care). Conventional resin cement was pretreated following the same steps (1-3) as those followed for self-adhesive specimens. Each group included 10 specimens. PEKK specimens after surface treatments were examined using SEM. SBS tests were performed using a universal testing machine, and data were statistically analyzed using one-way ANOVA and Tukey's multiple comparison test (p < 0.05). RESULTS: No significant difference was observed between cements with and without sandblasting. However, self-adhesive specimens with both mechanical and chemical pretreatments demonstrated higher SBS than other cements with or without pretreatment. CONCLUSION: Mechanical pretreatment by sandblasting did not improve the PEKK-root dentin SBS. However, combined mechanical (sandblasting) and chemical pretreatment (ScotchBond Universal) significantly improved the SBS between the PEKK and root dentin.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Cimentos Dentários/química , Análise do Estresse Dentário , Dentina
13.
Materials (Basel) ; 15(15)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35955169

RESUMO

Tooth enamel wear occurs because of daily mastication and occlusion. This study investigated the wear behavior of bovine teeth against aesthetic restorative materials in vitro. Abrader specimens were fabricated using four tooth-colored restorative materials (zirconia, lithium disilicate glass ceramic, dental porcelain, and resin composite), with bovine tooth enamel as a control. Flattened bovine tooth enamel was used as the substrate specimen. These materials were characterized by Vickers hardness tests and surface roughness measurements. Two-body wear tests between the abrader and substrate specimens were performed, and the worn topographies were evaluated using a contour-measuring instrument and 3D laser microscope. The restorative materials and bovine tooth enamel had similar surface roughness but different hardness and wear behaviors. Bovine teeth showed the largest wear in tooth-tooth contact as the abrader and substrate specimens. Compared to bovine teeth, zirconia, lithium disilicate glass ceramic, and dental porcelain showed greater hardness and less wear on their surfaces, and less substrate wear of the opposite tooth enamel. The lowest hardness resin composite showed intermediate wear on its surface, resulting in the lowest substrate wear. Accordingly, dentists should pay attention to the selection of restorative materials to reconstruct their morphologies owing to different wear behaviors.

15.
Dent Mater J ; 41(4): 552-559, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35321975

RESUMO

This study aimed to clarify the effects of vertical bone defect width and a ferrule on fracture of the fragments of fractured tooth reattached with adhesive resin cement (reattached tooth). The reattached tooth was built up by a fiber post and composite resin core for abutment and formed to the abutment with or without a ferrule. The vertical bone defect was fabricated with a V-shaped defect in different widths. The fracture load was evaluated using a universal testing machine. The vertical bone defect did not affect the fracture load, but a ferrule increased the root fracture load. For the specimens without a ferrule, debonding between the composite resin core and the root at the coronal loading side and fractures at the apical side of the root were found. In conclusion, the ferrule at abutment could affect fracture load and modes, and the bone defect width did not.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Resinas Compostas , Coroas , Cimentos Dentários , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Humanos , Cimentos de Resina
16.
Circ Arrhythm Electrophysiol ; 15(1): e010308, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34937390

RESUMO

BACKGROUND: Recent advancements in a 3-dimensional mapping system allow for the assessment of detailed conduction properties during sinus rhythm and thus the establishment of a strategy targeting functionally abnormal regions in scar-related ventricular tachycardia (VT). We hypothesized that a rotational activation pattern (RAP) observed in maps during baseline rhythm was associated with the critical location of VT. METHODS: We retrospectively examined the pattern of wavefront propagation during sinus rhythm in patients with scar-related VT. The prevalence and features of the RAP on critical VT circuits were analyzed. RAP was defined as >90° of inward curvature directly above or at the edge of the slow conductive areas. RESULTS: Forty-five VTs in 37 patients (66±15 years old, 89% male, 27% ischemic heart disease) were evaluated. High-density substrate mapping during sinus rhythm (median, 2524 points) was performed using the CARTO3 system before VT induction. Critical sites for reentry were identified by direct termination by radiofrequency catheter ablation in 21 VTs or by pace mapping in 12 VTs. Among them, RAP was present in 70% of the 33 VTs. Four VTs had no RAP at the critical sites during sinus rhythm, but it became visible in the mappings with different wavefront directions. Six VTs, in which intramural or epicardial isthmus was suspected, were rendered noninducible by radiofrequency catheter ablation to the endocardial surface without RAP. RAP had a sensitivity and specificity of 70% and 89%, respectively, for predicting the elements in the critical zone for VT. CONCLUSIONS: The critical zone of VT appears to correspond to an area characterized by the RAP with slow conduction during sinus rhythm, which facilitates targeting areas specific for reentry. However, this may not be applicable to intramural VT substrates and might be affected by the direction of wavefront propagation to the scar during mapping. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Ventricular/patologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
17.
Dent Mater J ; 40(5): 1264-1269, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34193726

RESUMO

The purpose of this study was to investigate the effects of fiber orientation, silane treatment, and thermal cycling on the retention force of fiber-reinforced composite resin (FRC) posts on resin composite. Two types of FRC posts (linear and woven) were prepared with and without silane treatment. Pull-out test specimens were made of FRC posts and resin composite for core buildup. Specimens were either incubated in distilled water for 24 h or subjected to 10,000 thermal cycles. The maximum fracture load obtained by a pull-out test was defined as the retention force. Fracture modes were observed after the test. Fiber orientation and thermal cycling did not affect the retention force on resin composite, and the retention force was improved by silane treatment. Whereas, fiber orientation affected the fracture mode. The result showed woven fiber orientation could contribute to the mechanically interlocking with the resin composite.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Resinas Compostas , Análise do Estresse Dentário , Vidro , Teste de Materiais , Cimentos de Resina , Silanos
18.
JACC Clin Electrophysiol ; 7(7): 843-854, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33640356

RESUMO

OBJECTIVES: This study sought to demonstrate a new type of verapamil-sensitive fascicular ventricular tachycardia (VT) with a reverse circuit. BACKGROUND: Left posterior fascicular ventricular tachycardia (LPFVT) is the most common form of verapamil-sensitive fascicular VT. Reverse-type LPFVT has not been reported. METHODS: We searched for a reverse-type LPFVT among 242 patients with verapamil-sensitive VT from February 2006 to September 2019. RESULTS: Three patients had a reverse-type LPFVT (cycle lengths: 340, 360, and 340 ms). QRS configuration during VT was narrow (140, 150, and 140 ms) and exhibited rSr' morphology in V1 with an early precordial transition and inferior axis. Two of 3 patients had common-type LPFVT. During reverse-type LPFVT, the earliest ventricular activation was the left superior middle septum. Fragmented Purkinje potentials (P1) buried within the local ventricular electrogram were recorded with an activation sequence from the apex to the base and were linked to the subsequent left ventricular septal activation. After radiofrequency catheter ablation at P1 during LPFVT, the reverse-type LPFVT also became noninducible. In 1 patient with only the reverse-type LPFVT, radiofrequency catheter ablation at the earliest LV activation site suppressed VT. These findings suggest that this new type of verapamil-sensitive fascicular VT shares a re-entrant circuit with a reverse direction of common LPFVT with an intramural exit site at the superior middle septum. CONCLUSIONS: Reverse-type LPFVT can occur. If common LPFVT exists, diastolic P1 during LPFVT can be a common target of ablation. If only reverse-LPFVT is inducible, the earliest ventricular activation site can be a target.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
19.
J Interv Card Electrophysiol ; 62(1): 21-30, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32939701

RESUMO

PURPOSE: Antral pulmonary vein isolation (PVI) using a radiofrequency hot balloon catheter (RHB) is a feasible therapeutic option for treating atrial fibrillation (AF). Lesion durability after antral RHB-PVI remains unknown. This study aimed to evaluate lesion durability and the associations between procedural characteristics after antral RHB-PVI. METHODS: A total of 200 patients received antral RHB-PVI using the single-shot technique between April 2016 and March 2018. Antral RHB-PVI was performed following a pre-specified protocol and RHB energy application was performed for a maximum of two times for each PV. Consecutive patients who underwent repeated procedures for recurrence of any type of atrial tachyarrhythmia were enrolled. RESULTS: Twenty-six (13%) patients underwent repeated ablation and 20 patient documented AF recurrence (AF group) and 6 patients documented non-AF recurrence (non-AF group). Repeated ablation was performed at a median (25th, 75th percentiles) of 378 days (217, 487) after the initial procedure and durable PVI was observed in 86 (83.5%) PVs. Durability reached 89.7% when PVI was achieved only using an RHB. In the AF group (79 PVs), durable PVI was observed in 62 (78.5%) PVs, whereas all 24 PVs were still isolated in the non-AF group. The majority of reconnection sites were around the superior PVs. CONCLUSIONS: Antral RHB-PVI shows high lesion durability, especially with both inferior PVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
20.
J Biomed Opt ; 25(12)2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33331151

RESUMO

SIGNIFICANCE: A scene-based adaptive-optics (AO) system is developed and a method for investigating its imaging performance is proposed. The system enables derivation of Strehl ratios from observed images via collaboration with computer simulations. The resultant Strehl ratios are comparable with those of other current AO systems. AIM: For versatile and noninvasive AO microscopy, a scene-based wavefront-sensing technique working on a Shack-Hartmann wavefront sensor is developed in a modal control system. The purpose of the research is to clarify the imaging performance of the AO system via the derivation of Strehl ratios from observed images toward applications in microscopy of living cells and tissues. APPROACH: Two imaging metrics that can be directly measured from observed images (i.e., an energy concentration ratio and unbiased maximum ratio) are defined and related to the Strehl ratio via computer simulations. Experiments are conducted using artificial targets to measure the imaging metrics, which are then converted to Strehl ratios. RESULTS: The resultant Strehl ratios are >0.7 and 0.5 in the cases of defocus and higher aberrations, respectively. The half-widths at half-maximum of the AO-corrected bead images are favorably comparable to those of on-focus images under simple defocus aberration, and the AO system works both under bright-field illumination and on fluorescent bead images. CONCLUSIONS: The proposed scene-based AO system is expected to work with a Strehl ratio of more than 0.5 when applied to high-resolution live imaging of cells and tissues under bright-field and fluorescence microscopies.


Assuntos
Microscopia , Simulação por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...