Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Clin Res Cardiol ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748208

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction in patients undergoing transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) has long been disregarded. We aimed to assess the predictive value of RV to pulmonary artery coupling (RV/PAc), defined as tricuspid annular plane systolic excursion to systolic pulmonary artery pressure, on mortality in different flow types of AS after TAVI. METHODS: All patients undergoing TAVI for AS at our centre between 2018 and 2020 were assessed; 862 patients were analysed. The cohort was dichotomized using a ROC analysis (cut-off 0.512 mm/mmHg), into 429 patients with preserved and 433 patients with reduced RV/PAc. RESULTS: Reduced RV/PAc was associated with male sex and a higher rate of comorbidities. Short-term VARC-3 endpoints and NYHA classes at follow-up were comparable. Reduced RV/PAc was associated with higher 2-year all-cause mortality (35.0% [30.3-39.3%] vs. 15.4% [11.9-18.7%], hazard ratio 2.5 [1.9-3.4], p < 0.001). Cardiovascular mortality was almost tripled. Results were consistent after statistical adjustment and in a multivariate model. Sub-analyses of AS flow types revealed lower RV/PAc in classical and paradoxical low-flow low-gradient AS, with the majority having reduced RV/PAc (74% and 59%). RV/PAc retained its predictive value in these subgroups. CONCLUSIONS: RV dysfunction defined by low RV/PAc is a strong mortality predictor after TAVI independent of flow group. It should be incorporated in future TAVI risk assessment.

2.
Physiol Int ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38748486

RESUMO

The global temperature rise will have extensive consequences on our organ systems, but hypohydration caused by reduced water intake or increased water loss through sweating plays the most relevant role. Many studies have already demonstrated the association between hypohydration and impaired exercise performance, but data related to the cardiac burden of hypohydration are scarce. This study is a sub-investigation of our large, prospective, self-controlled trial on the effects of hypohydration on cardiopulmonary exercise capacity with previously published results. In the current sub-study, we analyzed the impact of hypohydration on cardiac burden in this cohort of fifty healthy, recreational athletes during cardiopulmonary exercise test.Therefore, each participant underwent cardiopulmonary exercise test with a standardized ramp protocol twice, once in hypohydrated state and once in euhydrated state as control, and the cardiac markers Troponin T, NT-pro-BNP and Chromogranin A were measured before and after the exercise test at each state. Mean age was 29.7 years and 34% of probands were female. Hypohydration led to a reduced body water, a significant decrease in oxygen uptake and lower levels of power output. Yet, Troponin T, NT-proBNP, Chromogranin A and lactate levels did not significantly differ between the two conditions.In this study cohort, decreased exercise capacity during hypohydration was more likely due to impaired cardiac output with diminished plasma volume rather than measurable cardiac stress from fluid deprivation. However, whether these data are generalizable to a diseased cohort is left unanswered and should be addressed in future randomized controlled trials.

3.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658116

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Medição de Risco
4.
JACC Cardiovasc Interv ; 17(1): 76-87, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38199755

RESUMO

BACKGROUND: Knowledge about atrial functional tricuspid regurgitation (afTR) in transcatheter aortic valve replacement (TAVR) patients is scarce. OBJECTIVES: The aim of the study was to analyze the association between the entity and the development of tricuspid regurgitation (TR) in patients undergoing TAVR for aortic stenosis and concomitant TR. METHODS: We analyzed patients undergoing TAVR for severe aortic stenosis from January 2013 to December 2020 and concomitant at least moderate TR at baseline. afTR was defined as enlargement of the right atrium in relation to the right ventricle. TR development after TAVR and 3-year all-cause mortality were evaluated. RESULTS: Out of 3,474 TAVR patients, we identified 420 patients with concomitant at least moderate TR. A total of 363 patients were included in the study, with 178 patients stratified in the afTR and 185 in the non-afTR group based on a receiver-operating characteristic curve cutoff of 1.132 of the right atrial/right ventricular area ratio. TR improvement after TAVR was observed in significantly less patients with afTR compared with non-afTR (31.1% vs 60.6%; P < 0.001). Multivariate regression analysis confirmed afTR as independent predictor for TR persistence (adjusted OR: 2.80; 95% CI: 1.66-4.76; P < 0.001). Moreover, afTR was associated with aggravation of TR after TAVR (17.0% vs 6.8%; P = 0.013). Three-year all-cause mortality was significantly higher in patients with persistence compared with patients with improvement of TR (P < 0.001). CONCLUSIONS: In TAVR patients, afTR is an independent predictor for TR persistence. Moreover, TR persistence is associated with increased 3-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Átrios do Coração , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
5.
Catheter Cardiovasc Interv ; 103(1): 186-193, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38140761

RESUMO

BACKGROUND: Patients undergoing transcatheter aortic valve implantation (TAVI) frequently have coronary artery disease requiring percutaneous coronary intervention (PCI). Usually, PCI and TAVI are performed in two separate procedures and current studies are investigating potential benefits regarding the order. However, the two interventions may also be performed simultaneously, thereby limiting the risk associated with repeated vascular access. Data evaluating benefit and harm of concomitant procedures are scarce. AIMS: Therefore, this study aimed to evaluate concomitant PCI (coPCI) in TAVI patients regarding Valve Academic Research Consortium 3 (VARC-3) endpoints and long-term mortality. METHODS: A total of 2233 consecutive TAVI patients from the EVERY-VALVE registry were analyzed according to the VARC-3 endpoint definitions. A total of 274 patients had undergone TAVI and concomitant PCI (coPCI group). They were compared to 226 TAVI patients who had received PCI within 60 days before TAVI in a stepwise approach (swPCI group) and to the remaining 1733 TAVI patients who had not undergone PCI recently (noPCI group). RESULTS: Overall median age was 81.4 years, median Society of Thoracic Surgeons score was 4.0%. Patients in the coPCI and in the swPCI group were predominantly male with reduced left-ventricular ejection fraction. Rates of VARC-3 composite endpoints technical success and 30-day device success were comparable between all three groups. Mortality rates at 3 years after TAVI were similar (coPCI, 34.2% vs. swPCI, 31.9% vs. noPCI, 34.0% p = 0.84). CONCLUSIONS: coPCI during TAVI seems comparable in a retrospective analysis. Compared to a stepwise approach, it has similar rates of composite endpoints technical success and device success as well as long-term mortality.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
6.
Clin Res Cardiol ; 112(10): 1427-1435, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37337011

RESUMO

BACKGROUND: Cardiohepatic syndrome (CHS) has been identified as an important but underrecognized survival predictor in multiple cardiovascular disease entities. The objectives of this study were to evaluate the prevalence and prognostic value of CHS in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: The study included patients with available laboratory parameters of hepatic function who underwent TAVR from July 2013 until December 2019 at our center. CHS was defined as an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal (bilirubin, alkaline phosphatase, and gamma glutamyl transferase). Study endpoints were three-year survival, technical and device failure (VARC 3), as well as New York Heart Association (NYHA) functional class at follow-up. RESULTS: Among a total of 953 analyzed patients (47.6% females, median age 80.0 [76.0-85.0] years) CHS was present in 212 patients (22.4%). In patients with vs. without CHS, rates of technical (6.1% vs. 8.4%, p = 0.29) and device failure (18.9% vs. 17.3%, p = 0.59) were comparable. NYHA functional class at baseline and follow-up was more severe in patients with CHS. Nevertheless, heart failure symptoms improved from baseline to follow-up irrespective of hepatic function. Three-year survival rates were significantly lower in patients with CHS (49.4 vs. 65.4%, p < 0.001). The predictive value of CHS persisted after adjustment in a multivariable analysis (hazard ratio 1.58, p < 0.01). CONCLUSION: In patients undergoing TAVR, CHS is prevalent in 22% of patients and is associated with increased postinterventional mortality. Thus, CHS should be included in the decision-making process within the TAVR heart team. Cardiohepatic syndrome (CHS) as defined by an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal was prevalent in 22% of patients undergoing TAVR for severe AS. The presence of CHS was associated with more severe heart failure symptoms and worse three-year survival.


Assuntos
Estenose da Valva Aórtica , Colestase , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
7.
Eur J Heart Fail ; 25(6): 872-884, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36994662

RESUMO

AIMS: The impact of the cardio-hepatic syndrome (CHS) on outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) for relevant mitral regurgitation (MR) is unknown. The objectives of this study were three-fold: (i) to characterize the pattern of hepatic impairment, (ii) to investigate the prognostic value of CHS, and (iii) to evaluate the changes in hepatic function after M-TEER. METHODS AND RESULTS: Hepatic impairment was quantified by laboratory parameters of liver function. In accordance with existing literature, two types of CHS were distinguished: ischaemic type I CHS (elevation of both transaminases) and cholestatic type II CHS (elevation of two out of three parameters of hepatic cholestasis). The impact of CHS on 2-year mortality was evaluated using a Cox model. The change in hepatic function after M-TEER was assessed by laboratory testing at follow-up. We analysed 1083 patients who underwent M-TEER for relevant primary or secondary MR at four European centres between 2008 and 2019. Ischaemic type I and cholestatic type II CHS were observed in 11.1% and 23.0% of patients, respectively. Predictors for 2-year all-cause mortality differed by MR aetiology. While in primary MR cholestatic type II CHS was independently associated with 2-year mortality, ischaemic CHS type I was an independent mortality predictor in secondary MR patients. At follow-up, patients with MR reduction ≤2+ (obtained in 90.7% of patients) presented with improved parameters of hepatic function (median reduction of 0.2 mg/dl, 0.2 U/L and 21 U/L for bilirubin, alanine aminotransferase and gamma-glutamyl transferase, respectively, p < 0.01). CONCLUSIONS: The CHS is frequently observed in patients undergoing M-TEER and significantly impairs 2-year survival. Successful M-TEER may have beneficial effects on CHS.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fígado , Resultado do Tratamento , Cateterismo Cardíaco
8.
Pharmacol Ther ; 244: 108388, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36940792

RESUMO

Cardiac arrhythmias are a common and potentially serious cardiovascular disorders that affect both men and women. However, there is evidence to suggest that there may be sex-related differences in the prevalence, clinical presentation, and management of cardiac arrhythmias. Hormonal and cellular factors may play a role in these sex-specific differences. In addition, there are differences in the types of arrhythmias that men and women experience, with men more likely to experience ventricular arrhythmias and women more likely to experience supraventricular arrhythmias. The management of cardiac arrhythmias also differs between men and women. For example, some studies have found that women are less likely to receive appropriate treatment for arrhythmias and are more likely to have adverse outcomes following treatment. Despite these sex-related differences, the majority of research on cardiac arrhythmias has been conducted in men, and there is a need for more research to specifically examine the differences between men and women. This is especially important given that the prevalence of cardiac arrhythmia is increasing, and it is essential to understand how to effectively diagnose and treat these conditions in both men and women. In this review, we examine the current understanding of sex-related differences in cardiac arrhythmias. We also review the available data on sex-specific management strategies for cardiac arrhythmias and highlight areas of future research.


Assuntos
Arritmias Cardíacas , Doenças Cardiovasculares , Masculino , Humanos , Feminino , Fatores Sexuais , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Doenças Cardiovasculares/epidemiologia , Prevalência
9.
Int J Cardiol ; 376: 100-107, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36758861

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established, safe and effective therapy for severe symptomatic aortic stenosis (AS). The aim of this study was to objectively quantify improvement of physical activity after TAVR, with consideration of different low-gradient AS subtypes. METHODS AND RESULTS: All patients undergoing TAVR for severe AS were screened. Participants received a wearable activity tracker (Fitbit®) at hospital discharge following TAVR and 6 months thereafter. The difference of median daily steps was defined as surrogate outcome for physical activity. For analysis, patients were grouped into high-gradient (HG) AS (dPmean ≥40 mmHg), classical low-flow low-gradient (LFLG) AS (dPmean <40 mmHg, EF <50%), paradoxical LFLG-AS (dPmean <40 mmHg, EF ≥50%, SVi ≤35 ml/m2) and normal-flow low-gradient (NFLG) AS (dPmean <40 mmHg, EF ≥50%, SVi >35 ml/m2) according to mean transvalvular pressure gradient (dPmean), stroke volume index (SVi) and left-ventricular ejection fraction (LVEF). RESULTS AND CONCLUSIONS: The analysis is based on 230 patients. The median daily step count was 4409 [IQR 2581-7487] after hospital discharge and 5326 [IQR 3045-8668] 6 months thereafter. Median difference of daily steps was ∆529 [IQR -702-2152]). Patients with HG-AS and paradoxical LFLG-AS showed a significant improvement of daily steps (∆951 [IQR -378-2323], p <0.001 and (∆1392 [IQR -609-4444], p = 0.02, respectively). Patients with classical LFLG-AS showed no statistically relevant improvement of daily steps (∆192 [IQR -687-770], p = 0.79). Patients with NFLG-AS showed a numerical decline in daily steps without statistical significance (∆-300 [IQR -1334-1406], p = 0.67). This first prospective study of this sample size shows significant improvement of physical activity after TAVR with an objective and reproducible method. This was mainly driven by an improvement in patients with HG-AS and paradoxical LFLG-AS.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Exercício Físico , Resultado do Tratamento , Índice de Gravidade de Doença
10.
Clin Res Cardiol ; 112(5): 645-655, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36637479

RESUMO

AIM: The aim of this study was to analyse the predictive value of CTA-determined tricuspid annular dilatation (TAD) on the persistence of tricuspid regurgitation (TR) in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) and concomitant at least moderate TR. METHODS AND RESULTS: 288 consecutive patients treated with TAVR due to severe AS and concomitant at least moderate TR at baseline were included in the analysis. As cutoff for TAD, the median value of the CTA-determined, to the body surface area-normalized tricuspid annulus diameter (25.2 mm/m2) was used. TAD had no impact on procedural characteristics or outcomes, including procedural death and technical or device failure according to the Valve Academic Research Consortium 3 criteria. However, the primary outcome of the study-TR persistence after TAVR was significantly more frequent in patients with compared to patients without TAD (odds ratio 2.60, 95% confidence interval 1.33-5.16, p < 0.01). Multivariable logistic regression analysis, adjusting for clinical and echocardiographic baseline characteristics, which are known to influence aetiology or severity of TR, confirmed TAD as an independent predictor of TR persistence after TAVR (adjusted odds ratio 2.30, 95% confidence interval 1.20-4.46, p = 0.01). Moreover, 2 year all-cause mortality was significantly higher in patients with persistence or without change of TR compared to patients with TR improvement (log-rank p < 0.01). CONCLUSION: In patients undergoing TAVR for severe AS and concomitant at least moderate TR at baseline, TAD is a predictor of TR persistence, which is associated with increased 2-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Dilatação/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
11.
Int J Cardiol ; 371: 299-304, 2023 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-36306951

RESUMO

BACKGROUND: Normal-flow (stroke volume index, SVi >35 ml/m2) low-gradient (dPmean <40 mmHg) aortic stenosis (NFLG-AS) is subject of scientific debate. Guidelines fail to give conclusive treatment recommendations. We hypothesized that NFLG patients are heterogenous, containing a subgroup similar to high-gradient aortic stenosis patients (dPmean ≥40 mmHg, HG-AS) concerning characteristics and outcomes. METHODS: 2326 patients undergoing transcatheter aortic valve replacement (TAVI) at our centre between 2013 and 2019 were analysed. 386 patients fulfilled criteria of NFLG-AS. Their median dPmean was 33 mmHg, which was used for grouping (204 patients with higher gradient NFLG-AS, 186 patients with lower gradient NFLG-AS). They were compared to 956 HG-AS patients. RESULTS: Characteristics of lower gradient NFLG-AS patients differed from HG-AS patients in many aspects while higher gradient NFLG-AS and HG-AS patients were mostly similar, underscored by higher Society of Thoracic Surgeons scores in lower gradient NFLG-AS (lower gradient NFLG-AS, 3.9, HG-AS, 3.0, p = 0.03, higher gradient NFLG-AS, 3.0, p = 0.04). Procedural complications were comparable. Estimated 3-year all-cause mortality was higher in lower gradient NFLG-AS compared to HG-AS patients (hazard ratio 1.7, p < 0.01), whereas mortality of higher gradient NFLG-AS was similar to HG-AS patients (hazard ratio 1.2, p = 0.31). Cardiovascular mortality was highest among lower gradient NFLG-AS patients (21.6% vs. higher gradient NFLG-AS, 15.4%, vs. HG-AS, 11.1%, p < 0.01). CONCLUSIONS: NFLG-AS patients are indeed heterogenous. NFLG-AS patients with higher gradients resemble HG-AS patients in clinical characteristics and outcomes and should not be treated differently. Lower gradient NFLG-AS patients have increased long-term mortality and the use of TAVI requires careful consideration.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Função Ventricular Esquerda , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Índice de Gravidade de Doença
12.
Patient Prefer Adherence ; 16: 3027-3033, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36387054

RESUMO

Background: The subcutaneous cardioverter defibrillator (S-ICD) has been shown to be a viable alternative to transvenous ICDs (TV-ICD) in all patients at risk of sudden cardiac death (SCD) but without pacing indication. Aim: The aim of this study was to examine the impact of therapy with current S-ICD devices on quality of life (QoL) in comparison to patients with TV-ICD devices. Methods: In our single-centre study, 52 consecutive patients with S-ICD and 52 matched patients with TV-ICD were analysed. QoL has been assessed by a standardized questionnaire (EQ-5D-3L, modified). Additionally, clinical baseline and follow-up data were evaluated. Results: Two-thirds of the total study population reported restrictions in daily routine compared to their life before ICD implantation. A total of 27.7% of S-ICD patients stated to expect an improvement of QoL by deactivation or explantation of their defibrillator compared to only 6.4% of patients with TV-ICD (p=0.006), which was mainly caused by discomfort and pain from the S-ICD pocket (relevant discomfort and pain in 32.6% vs 11.5%; p<0.01). Limitations: Main limitation of the study is that quality of life was assessed for one single time point only and time since implantation differed significantly between S-ICD and TV-ICD. Furthermore our collective is younger, and, due to the high proportion of patients without cardiomyopathy, the mean EF is better than usual ICD collective. The absence of heart failure in about the half of our patients might have relevant impact on our QoL analysis. Conclusion: A relevant proportion of S-ICD patients expects an improvement of QoL by explantation of the device. Of note, this impression was not driven by the fear of receiving shocks but mainly by discomfort and pain caused by the pulse generator.

13.
Eur Heart J Acute Cardiovasc Care ; 11(12): 877-886, 2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36210517

RESUMO

AIMS: Severe aortic stenosis can cause acute heart failure and cardiogenic shock (CS). Transcatheter aortic valve implantation (TAVI) is the standard therapy for aortic stenosis in inoperable patients. However, its role in this setting is poorly evaluated. The study purpose was to explore clinical characteristics of these patients and to assess predictors of mortality. METHODS AND RESULTS: All 2930 patients undergoing transfemoral TAVI at our centre between 2013 and 2019 were screened for critically ill patients, receiving intensive care therapy and emergency TAVI. Selected patients were subdivided into two groups, according to the presence or absence of CS. Remaining patients undergoing elective TAVI served as a comparison. Primary outcome was 90-day mortality. Out of 179 critically ill patients, 47 fulfilled criteria of CS (shock group) and 132 did not despite a severe decompensation (no shock group). Shock patients were more often male and had higher Society of Thoracic Surgeons scores [15.6, interquartile range (8.0-32.1) vs. 5.5 (3.9-8.5), P < 0.01] compared with severely decompensated patients. Ninety-day mortality was: shock group, 42.6%, vs. no shock group, 15.9%, vs. elective group, 5.3% (P < 0.01). A landmark analysis from day 90 showed similar mortality (P = 0.29). Compared with elective patients, 30-day composite endpoint device failure was higher in critically ill groups [shock group, odds ratio, 2.86 (1.43-5.36), no shock group, odds ratio, 1.74 (1.09-2.69)]. Multivariable regression revealed mechanical ventilation, haemofiltration, elevated C-reactive protein or bilirubin, and hypotension before TAVI as 90-day mortality predictors. CONCLUSION: Ninety-day mortality after TAVI in critically ill patients is increased but survivors have similar outcomes as elective patients.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Estado Terminal , Fatores de Risco , Resultado do Tratamento , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia
14.
Int J Emerg Med ; 15(1): 49, 2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36100863

RESUMO

BACKGROUND: Symptoms caused by cardiac arrhythmia are common problems that lead to presentation to the emergency department. However, the prevalence of pathological heart rhythm in patients triaged for cardiac arrhythmia in the emergency department remains up to now unknown. METHODS AND RESULTS: In this retrospective study, patients triaged for cardiac arrhythmia admitted to the interdisciplinary emergency department of the Ludwig-Maximilians University Hospital in Munich within 1 year were included. Subsequently, cardiac rhythm in the 12-lead electrocardiogram, clinical presentation, admission rate, and diagnosis at discharge was analyzed. A total of 558 out of 39,798 patients were triaged for cardiac arrhythmia. Of these 42.3% of patients showed a pathological heart rhythm on the initial electrocardiogram (66.9% atrial fibrillation, 16.5% atrial flutter, 16.5% others). About 80% presented in emergency severity index III (many resources are needed without critical vitals) conditions. Sixty-two percent of the pathological electrocardiogram group and 60% of the sinus rhythm group of patients were admitted to the hospital, and 34.7% with pathological electrocardiogram underwent invasive investigations (16.8% in the sinus rhythm group). In 43.4% of patients, the diagnosis of cardiac arrhythmia was already known from previous medical contacts. CONCLUSION: A total of 1.8% of patients who presented to our interdisciplinary emergency department were triaged for cardiac arrhythmia. With 49.5%, the hospital admission rate was quite high but the patients presented to the emergency department in our cohort were rarely in critical condition. As a high percentage of our cohort had a history of cardiac arrhythmia, better outpatient management is needed for these patients to reduce emergency department visits and save resources.

15.
EuroIntervention ; 18(10): 812-819, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-35903846

RESUMO

BACKGROUND: Large-bore arteriotomy for transcatheter aortic valve implantation (TAVI) requires percutaneous vascular closure devices, but real-world data comparing different closure strategies are limited. AIMS: We sought to compare a dual ProGlide strategy vs a combination of one ProGlide and one FemoSeal for vascular closure after TAVI. METHODS: We retrospectively analysed 874 propensity score-matched patients undergoing TAVI at the Munich University Hospital from August 2018 to October 2020. From August 2018 to August 2019, a dual ProGlide strategy was used for vascular closure. From October 2019 to October 2020, a combination of one ProGlide and one FemoSeal was used. The primary endpoint was defined as access-related major vascular complications or bleeding ≥Type 2 according to Valve Academic Research Consortium 3 criteria. RESULTS: Patients in the dual ProGlide group (n=437) had a higher incidence of the primary endpoint than patients treated with one ProGlide and one FemoSeal (n=437; 11.4% vs 3.0%; p<0.001). Furthermore, they had a higher rate of closure device failure (2.7% vs 0.9%; p=0.044) and more often required unplanned surgery or endovascular treatment (3.9% vs 0.9%; p=0.004). The incidence of death did not differ significantly between groups (3.4% vs 1.6%; p=0.08). CONCLUSIONS: A combined ProGlide and FemoSeal strategy might have the potential to reduce access-related vascular complications following TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Artéria Femoral/cirurgia , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos , Hemostasia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Técnicas Hemostáticas/efeitos adversos
16.
J Cardiovasc Comput Tomogr ; 16(5): 423-430, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35637128

RESUMO

BACKGROUND: Computed tomography (CT) imaging is the standard of care before transcatheter aortic valve replacement (TAVR). The aortic annulus undergoes conformational changes during the heart cycle. Therefore, the image acquisition time point can impact prosthesis sizing and fit. Clinical outcome data are lacking. The aim of this study was to compare systolic and diastolic cardiac CT data acquisition with regard to procedural and clinical outcomes in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: Preprocedural high-pitch helical CT datasets were analyzed in 1954 patients undergoing TAVR between 2013 and 2018 â€‹at our center. Patients were stratified into two groups according to the acquisition heart phase (979 systolic and 975 diastolic). The study was approved by the local ethics committee. RESULTS: Median age was 81.6 [interquartile range 77.5-85.8] years and 964 (49.3%) patients were male. No significant difference was found for the Valve Academic Research Consortium-3 (VARC-3) endpoints of technical failure (systolic, 5.1% vs. diastolic, 5.2%, p â€‹= â€‹0.94) or device failure (systolic, 13.7% vs. diastolic, 13.5%, p â€‹= â€‹0.92). There was no difference in paravalvular regurgitation. All-cause 30-day mortality was comparable (systolic, 3.6% [95% confidence interval, 2.4-4.7%] vs. diastolic, 3.6% [2.4-4.8%], p â€‹= â€‹1.00), while 3-year mortality rates were higher in the diastolic group (Society of Thoracic Surgeons score adjusted hazard ratio, 1.25 [1.07-1.46], p â€‹< â€‹0.01). CONCLUSIONS: While the 30-day technical and clinical outcomes after TAVR are comparable between systolic and diastolic CT imaging, diastolic imaging was associated with higher long-term mortality. Therefore, the data support the guideline recommendation of systolic imaging.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Sopros Cardíacos/etiologia , Humanos , Masculino , Valor Preditivo dos Testes , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
17.
Clin Res Cardiol ; 111(12): 1325-1335, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35320407

RESUMO

OBJECTIVES: The study objective was to characterize different groups of low-flow low-gradient (LFLG) aortic stenosis (AS) and determine short-term outcomes and long-term mortality according to Valve Academic Research Consortium-3 (VARC-3) endpoint definitions. BACKGROUND: Characteristics and outcomes of patients with LFLG AS undergoing transcatheter aortic valve implantation (TAVI) are poorly understood. METHODS: All patients undergoing TAVI at our center between 2013 and 2019 were screened. Patients were divided into three groups according to mean pressure gradient (dPmean), ejection fraction (LVEF), and stroke volume index (SVi): high gradient (HG) AS (dPmean ≥ 40 mmHg), classical LFLG (cLFLG) AS (dPmean < 40 mmHg, LVEF < 50%), and paradoxical LFLG (pLFLG) AS (dPmean < 40 mmHg, LVEF ≥ 50%, SVi ≤ 35 ml/m2). RESULTS: We included 1776 patients (956 HG, 447 cLFLG, and 373 pLFLG patients). Most baseline characteristics differed significantly. Median Society of Thoracic Surgeons (STS) score was highest in cLFLG, followed by pLFLG and HG patients (5.0, 3.9 and 3.0, respectively, p < 0.01). Compared to HG patients, odds ratios for the short-term VARC-3 composite endpoints, technical failure (cLFLG, 0.76 [95% confidence interval, 0.40-1.36], pLFLG, 1.37 [0.79-2.31]) and device failure (cLFLG, 1.06 [0.74-1.49], pLFLG, 0.97 [0.66-1.41]) were similar, without relevant differences within LFLG patients. NYHA classes improved equally in all groups. Compared to HG, LFLG patients had a higher 3-year all-cause mortality (STS score-adjusted hazard ratios, cLFLG 2.16 [1.77-2.64], pLFLG 1.53 [1.22-193]), as well as cardiovascular mortality (cLFLG, 2.88 [2.15-3.84], pLFLG, 2.08 [1.50-2.87]). CONCLUSIONS: While 3-year mortality remains high after TAVI in LFLG compared to HG patients, symptoms improve in all subsets after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Índice de Gravidade de Doença , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...