Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Sports Med ; 49(12): 3196-3201, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34528841

RESUMO

BACKGROUND: Arthroscopic treatment of calcifying tendinitis of the shoulder reveals good to excellent results. However, whether the tendon needs to be repaired after removal of the calcific deposit or simply debrided remains unclear. PURPOSE: To evaluate the structural and clinical results after arthroscopic calcific deposit removal with additional rotator cuff repair or rotator cuff debridement. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A total of 44 patients (46 shoulders) were enrolled in this retrospective cohort study with a mean follow-up of 58.4 months. Patients underwent arthroscopic removal of a calcific deposit and bursectomy after failed nonoperative treatment. A total of 22 patients received additional rotator cuff repair irrespective of the degree of debridement (the repair group), whereas 22 patients received a simple rotator cuff debridement without additional repair (the debridement group). Groups were comparable in sex, age, and size and consistency of the deposits according to the Gärtner and Bosworth classifications. Clinical evaluation was performed by the Constant score, Simple Shoulder Test, American Shoulder and Elbow Surgeons (ASES) score, and numerical rating scales for pain, function, and satisfaction. In 29 patients (14 in the debridement group and 15 in the repair group), additional magnetic resonance imaging at follow-up was performed to evaluate the structural results using the Sugaya classification. RESULTS: All patients were satisfied with the results of surgery; 100% of the repair group and 95.7% of the debridement group reported they would undergo the surgical procedure again. Comparison of the clinical results showed significantly better results in the repair group versus the debridement group for the Constant score (86.2 vs 80.6, respectively; P = .04), the ASES score (98.3 vs 88.9; P = .004), the Simple Shoulder Test (11.6 vs 10; P = .005), and the numerical rating scales for pain (0.1 vs 0.8; P = .007), function (9.6 vs 8.8; P = .008), and satisfaction (9.8 vs 9.1; P = .036). Comparison of the postoperative tendon integrity showed 80% Sugaya grade I in the rotator cuff repair group and 64% Sugaya grade II in the debridement group, with a statistically significant difference in favor of the repair group (P = .004). Postoperative clinical evaluation revealed no positive O'Brien tests in the repair group, whereas approximately one-third of the debridement group showed a positive O'Brien test during examination. CONCLUSION: Arthroscopic removal of calcific deposits with rotator cuff debridement or cuff repair showed good to excellent clinical and structural midterm results. However, patients who underwent additional repair of the tendon defect had significantly better clinical results as well as better structural results in terms of tendon integrity.


Assuntos
Lesões do Manguito Rotador , Tendinopatia , Artroscopia , Estudos de Coortes , Desbridamento , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Ombro , Tendinopatia/cirurgia , Resultado do Tratamento
2.
Orthop J Sports Med ; 9(2): 2325967120985106, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33738311

RESUMO

BACKGROUND: The best surgical treatment option for symptomatic moderate- to high-grade articular-sided partial-thickness rotator cuff tears (PTRCTs) is still controversial. PURPOSE/HYPOTHESIS: The purpose of this study was to evaluate patient-reported and clinical outcomes and tendon integrity after arthroscopic debridement or repair for PTRCTs at a minimum of 2 years postoperatively. We hypothesized that the overall outcomes would be positive, showing pain relief, good shoulder function, and high tendon integrity. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: We evaluated 30 patients (16 men, 14 women; mean age, 51 years) who underwent arthroscopic treatment for symptomatic PTRCTs (Ellman grades 2 and 3). Debridement was performed in 15 patients, and arthroscopic tendon repair was performed in the remaining 15 patients. Patients completed the Constant score; American Shoulder and Elbow Surgeons (ASES) shoulder score; Western Ontario Rotator Cuff Index; Simple Shoulder Test; and visual analog scale (VAS) for pain, function, and satisfaction. In addition, patients were examined clinically (range of motion, impingement tests, rotator cuff tests, and tests for the long head of the biceps tendon), and morphologic assessment of rotator cuff integrity was performed using direct magnetic resonance arthrography and was classified according to Sugaya. RESULTS: The mean follow-up period was 55 months. The patient-reported outcome measures showed high patient satisfaction, reduction in persistent pain, and good shoulder function. Linear regression analysis showed that the debridement group had significantly better results on the Constant (bias-corrected and accelerated [BCa] 95% CI, 4.20-26.30), ASES (BCa 95% CI, 5.24-39.26), and VAS (pain: BCa 95% CI, 0.13-3.62; function: BCa 95% CI, 1.04-4.84; satisfaction: BCa 95% CI, 0.14-6.28) scores than did the repair group. At follow-up, there was no significant difference between the groups in clinical testing results. Good supraspinatus tendon integrity was seen in most patients: Sugaya classification grade 1 in 13 patients, grade 2 in 11 patients, and grade 3 in 6 patients. CONCLUSION: Midterm results after arthroscopic debridement and repair for PTRCTs showed high patient satisfaction, good shoulder function, and high tendon integrity for both procedures. Patients who underwent arthroscopic debridement had higher Constant, ASES, and VAS scores compared with patients who underwent tendon repair.

3.
J Exp Orthop ; 5(1): 28, 2018 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-30091026

RESUMO

BACKGROUND: Many different fixation devices are used to maintain the correction angle after medial open wedge high tibial osteotomy (MOWHTO). Each device must provide at least sufficient mechanical stability to avoid loss of correction and unwanted fracture of the contralateral cortex until the bone heals. In the present study, the mechanical stability of following different implants was compared: the TomoFix small stature (sm), the TomoFix standard (std), the Contour Lock, the iBalance and the second generation PEEKPower. Simplified loading, usually consisting of a vertical load applied to the tibia plateau, is used for experimental testing of fixation devices and also in numerical studies. Therefore, this study additionally compared this simplified experimental loading with a more realistic loading that includes the muscle forces. METHOD: Two types of finite element models, according to the considered loading, were created. The first type numerically simulated the static tests of MOWHTO implants performed in a previous experimental biomechanical study, by applying a vertical compressive load perpendicularly to the plateau of the osteotomized tibia. The second type included muscle forces in finite element models of the lower limb with osteotomized tibiae and simulated the stance phase of normal gait. Section forces in the models were determined and compared. Stresses in the implants and contralateral cortex, and micromovements of the osteotomy wedge, were calculated. RESULTS: For both loading types, the stresses in the implants were lower than the threshold values defined by the material strength. The stresses in the lateral cortex were smaller than the ultimate tensile strength of the cortical bone. The implants iBalance and Contour Lock allowed the smallest micromovements of the wedge, while the PEEKPower allowed the highest. There was a correlation between the micromovements of the wedge, obtained for the simplified loading of the tibia, and the more realistic loading of the lower limb at 15% of the gait cycle (Pearson's value r = 0.982). CONCLUSIONS: An axial compressive load applied perpendicularly to the tibia plateau, with a magnitude equal to the first peak value of the knee joint contact forces, corresponds quite well to a realistic loading of the tibia during the stance phase of normal gait (at 15% of the gait cycle and a knee flexion of about 22 degrees). However, this magnitude of the knee joint contact forces overloads the tibia compared to more realistic calculations, where the muscle forces are considered. The iBalance and Contour Lock implants provide higher rigidity to the bone-implant constructs compared to the TomoFix and the PEEKPower plates.

4.
Arthroscopy ; 34(4): 1072-1082, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29305291

RESUMO

PURPOSE: Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. METHODS: Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. RESULTS: No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). CONCLUSIONS: The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. CLINICAL RELEVANCE: Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee.


Assuntos
Traumatismos do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Articulação Patelofemoral/cirurgia , Tendões/transplante , Fenômenos Biomecânicos/fisiologia , Cadáver , Fêmur/cirurgia , Músculo Grácil , Humanos , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Ligamentos Articulares/lesões , Ligamentos Articulares/fisiopatologia , Articulação Patelofemoral/fisiopatologia , Pressão , Amplitude de Movimento Articular
5.
Arch Orthop Trauma Surg ; 137(12): 1719-1724, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28942510

RESUMO

INTRODUCTION: The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. MATERIALS AND METHODS: 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. RESULTS: MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. CONCLUSIONS: The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. LEVEL OF EVIDENCE: Level II, Diagnostic study.


Assuntos
Imageamento por Ressonância Magnética , Exame Físico , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/classificação , Sensibilidade e Especificidade
6.
Knee Surg Sports Traumatol Arthrosc ; 25(8): 2502-2510, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26820966

RESUMO

PURPOSE: To evaluate the knee kinematics of the intact, MPFL-ruptured and MPFL-reconstructed knee and, moreover, to compare dynamic patellofemoral contact pressure of the gracilis tendon and the fascia lata as an alternative graft option for reconstruction of the MPFL. METHODS: Eight paired human cadaveric knees were fixed in a custom-made fixation device. Patellofemoral contact pressure was assessed during a dynamic flexion movement at 15°-30°-45°-60°-75° and 90° using a pressure-sensitive film (Tekscan). The medial patellofemoral ligament was cut, and measurements were repeated. Finally, reconstruction of the MPFL was performed using the gracilis tendon (group I) or a fascia lata graft (group II). Tunnel localization was performed under fluoroscopic control. Grafts were fixed at 30° of flexion, and pressure measurements were repeated. RESULTS: Incision of the medial patellofemoral ligament significantly reduced patellofemoral contact pressure at 15°, 30° and 45° of knee flexion compared to the intact knee (p < 0.05), whereas reconstruction of the MPFL using either gracilis tendon of the fascia lata was able to restore pressure distributions at 15° and 30° of knee flexion. However, in the hamstring group, reconstruction of the MPFL revealed a significantly reduced contact pressure at 45° of flexion (p = 0.038) compared to the intact knee. In the fascia lata group, a significant reduction in patellofemoral contact pressure was observed after MPFL reconstruction at 45°, 60°, 75° and 90° of knee flexion (p < 0.05). CONCLUSIONS: Anatomic reconstruction of the MPFL with either a gracilis or a fascia lata graft showed comparable patellofemoral pressure distributions which were closely restored compared to the native knee. Therefore, the fascia lata has shown to be a viable alternative to the gracilis tendon for reconstruction of the MPFL. However, anatomic reconstruction of the MPFL may lead to persistently altered patellofemoral contact pressure during knee flexion compared to the native knee independent of the tested graft.


Assuntos
Fascia Lata/transplante , Músculo Grácil/cirurgia , Ligamentos Articulares/cirurgia , Articulação Patelofemoral/cirurgia , Pressão , Amplitude de Movimento Articular , Tendões/transplante , Fenômenos Biomecânicos , Cadáver , Fluoroscopia , Músculos Isquiossurais , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Ligamentos Articulares/fisiopatologia , Articulação Patelofemoral/fisiopatologia , Procedimentos de Cirurgia Plástica
7.
Arthrosc Tech ; 5(6): e1419-e1424, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28149740

RESUMO

Chronic patellar tendinosis (jumper's knee) is a common problem among athletes. Conservative treatment is successful in most of the cases including, among others, the use of nonsteroidal anti-inflammatory drugs, local cryotherapy, eccentric muscle training, limitation of sports activity, and local infiltration. In approximately 10% of conservatively treated patients, conservative treatment fails and surgery is required. Different open and arthroscopic surgical techniques have been described in the literature. The presented all-arthroscopic surgical technique for the treatment of chronic patellar tendinosis includes debridement of soft tissue at the lower patellar pole and resection of the bony lower patellar pole. It leads to excellent clinical results comparable to described open treatment and provides the benefits of a minimally invasive and safe procedure with a faster recovery and return to sporting activities after surgery. An additional bony resection in case of a prominent lower patellar pole does not lead to a significant extension of the operation time and may avoid a relapse or treatment failure in selective cases. Therefore, arthroscopic treatment such as the presented technique may be the preferred method for surgical treatment of chronic patellar tendinosis.

8.
Arthrosc Tech ; 4(1): e57-63, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25973375

RESUMO

The medial patellofemoral ligament (MPFL) ensures stability of the patella against lateral forces. In cases of recurrent lateral patellar luxation, surgical reconstruction of the MPFL has an important role in treating lateral patellar instability. Several biomechanical studies have presented valuable pieces of information about various techniques for re-creating this medial patellofemoral complex mainly using the gracilis tendon as an autograft. However, with the increasing number of MPFL reconstructions, there are also an increasing number of patients requiring revision MPFL reconstruction. Therefore alternative graft options may become more relevant. Furthermore, the gracilis tendon as a tubular graft may not be able to fully restore patellofemoral kinematics compared with the native MPFL. This article introduces a surgical technique using the fascia lata as an alternative graft option for the anatomic reconstruction of the MPFL.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...