1.
Int J Mol Sci ; 21(14)2020 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-32660137

RESUMO

Temporal translational signalling cues modulate all forms of tissue morphogenesis. However, if the rules to obtain specific tissues rely upon specific ligands to be active or inactive, does this mean we can engineer any tissue from another? The present study focused on the temporal effect of "multiple" morphogen interactions on muscle tissue to figure out if chondrogenesis could be induced, opening up the way for new tissue models or therapies. Gene expression and histomorphometrical analysis of muscle tissue exposed to rat bone morphogenic protein 2 (rBMP-2), rat transforming growth factor beta 3 (rTGF-ß3), and/or rBMP-7, including different combinations applied briefly for 48 h or continuously for 30 days, revealed that a continuous rBMP-2 stimulation seems to be critical to initiate a chondrogenesis response that was limited to the first seven days of culture, but only in the absence of rBMP-7 and/or rTGF-ß3. After day 7, unknown modulatory effects retard rBMP-2s' effect where only through the paired-up addition of rBMP-7 and/or rTGF-ß3 a chondrogenesis-like reaction seemed to be maintained. This new tissue model, whilst still very crude in its design, is a world-first attempt to better understand how multiple morphogens affect tissue morphogenesis with time, with our goal being to one day predict the chronological order of what signals have to be applied, when, for how long, and with which other signals to induce and maintain a desired tissue morphogenesis.


Assuntos
Condrogênese/genética , Morfogênese/genética , Músculos/fisiologia , Transdução de Sinais/genética , Fator de Crescimento Transformador beta3/genética , Animais , Proteína Morfogenética Óssea 2/genética , Proteína Morfogenética Óssea 7/genética , Sinais (Psicologia) , Expressão Gênica/genética , Masculino , Ratos , Ratos Endogâmicos F344 , Transdução de Sinais/fisiologia
2.
BMC Biotechnol ; 20(1): 8, 2020 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-32005149

RESUMO

BACKGROUND: The translation from animal research into the clinical environment remains problematic, as animal systems do not adequately replicate the human in vivo environment. Bioreactors have emerged as a good alternative that can reproduce part of the human in vivo processes at an in vitro level. However, in vitro bone formation platforms primarily utilize stem cells only, with tissue based in vitro systems remaining poorly investigated. As such, the present pilot study explored the tissue behavior and cell survival capability within a new in vitro skeletal muscle tissue-based biomaterial organoid bioreactor system to maximize future bone tissue engineering prospects. RESULTS: Three dimensional printed ß-tricalcium phosphate/hydroxyapatite devices were either wrapped in a sheet of rat muscle tissue or first implanted in a heterotopic muscle pouch that was then excised and cultured in vitro for up to 30 days. Devices wrapped in muscle tissue showed cell death by day 15. Contrarily, devices in muscle pouches showed angiogenic and limited osteogenic gene expression tendencies with consistent TGF-ß1, COL4A1, VEGF-A, RUNX-2, and BMP-2 up-regulation, respectively. Histologically, muscle tissue degradation and fibrin release was seen being absorbed by devices acting possibly as a support for new tissue formation in the bioceramic scaffold that supports progenitor stem cell osteogenic differentiation. CONCLUSIONS: These results therefore demonstrate that the skeletal muscle pouch-based biomaterial culturing system can support tissue survival over a prolonged culture period and represents a novel organoid tissue model that with further adjustments could generate bone tissue for direct clinical transplantations.


Assuntos
Materiais Biocompatíveis/farmacologia , Músculo Esquelético/citologia , Organoides/citologia , Osteogênese , Células-Tronco/citologia , Engenharia Tecidual/métodos , Animais , Materiais Biocompatíveis/química , Biomarcadores/metabolismo , Reatores Biológicos , Fosfatos de Cálcio/química , Fosfatos de Cálcio/farmacologia , Diferenciação Celular/efeitos dos fármacos , Durapatita/química , Durapatita/farmacologia , Músculo Esquelético/metabolismo , Projetos Piloto , Impressão Tridimensional , Estudo de Prova de Conceito , Ratos , Células-Tronco/efeitos dos fármacos , Células-Tronco/metabolismo , Alicerces Teciduais , Sobrevivência de Tecidos
4.
Electromagn Biol Med ; 37(4): 175-183, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30183430

RESUMO

Rotator cuff (RC) tendinopathy is the most common cause of shoulder pain. The effectiveness of electromagnetic transduction therapy (EMTT), a high energetic pulsed electromagnetic field therapy in this field has not been tested yet in combination with extracorporeal shock wave therapy (ESWT). A total of 86 patients with RC tendinopathy were randomized to undergo three sessions of ESWT in combination with 8 sessions of EMTT or sham-EMTT. Both intervention groups experienced significant and clinical relevant decrease of pain at all follow-up visits, and the functionality of the shoulder evaluated by the Constant Murley score increased significantly as well. The combination of EMTT + ESWT produced significantly greater pain reduction in the visual analogue scale compared to ESWT with sham-EMTT after 24 weeks, during which the Constant Murley score improved significantly when the combination of ESWT and EMTT was employed. In patients with RC tendinopathy, electromagnetic transduction therapy combined with extracorporeal shock wave therapy significantly improves pain and function compared to ESWT with sham-EMTT.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Magnetoterapia , Manguito Rotador , Tendinopatia/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
5.
J Orthop ; 14(3): 410-415, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28736490

RESUMO

OBJECTIVES: A prospective randomised controlled trial to investigate the efficacy of electromagnetic transduction therapy (EMTT) for treatment of patients with non-specific low back pain. DESIGN: Two groups with non-specific low back pain were either treated with conventional therapy alone over 6 weeks or in combination with 8 sessions of EMTT. RESULTS: In both intervention groups the low back pain related pain and the degree of disability decreased significantly at follow-up visits. Combination of EMTT and conventional therapy proved significant superior to conventional therapy alone. CONCLUSION: EMTT is a promising treatment in patients with non-specific low back pain.

6.
J Biomater Appl ; 30(1): 30-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25627649

RESUMO

Polymethylmethacrylate-based bone cements are widely used for fixation of joint replacements. To improve the long-term outcome, bioactive bone cements are aspired to advance the bone-cement interface. This study evaluated the in vivo properties of a new polymethylmethacrylate-based bioactive bone cement with addition of amphiphilic phosphorylated 2-hydroxyethylmethacrylate. Previous in vitro studies confirmed bioactive properties in cell culture, as well as unchanged mechanical properties are tests according to ISO 5833:2002.Three different variations of the cement (polymethylmethacrylate + phosphorylated 2-hydroxyethylmethacrylate, polymethylmethacrylate + phosphorylated 2-hydroxyethylmethacrylate + CaCl2 and polymethylmethacrylate + phosphorylated 2-hydroxyethylmethacrylate + CaCl2 + Na2CO3) were compared to conventional polymethylmethacrylate cement. To evaluate the properties under load-bearing conditions, a spacer prosthesis was implanted into the femoral diaphysis of 24 rabbits. Additionally, a cement plug was installed into the proximal tibia. After three months, polished sections with Giemsa surface staining were prepared. The bioactivity was determined using the bone affinity index.The sections showed a good osseointegration of the bioactive bone cement without cement cracks under load-bearing conditions. Regarding the bone affinity index, the bioactive bone cement revealed a significantly higher value in the proximal tibia (25.9-37.7%) and around the spacer prosthesis (36.8-58.9%) compared to the conventional polymethylmethacrylate cement (12.8-17.0%).The results confirm the in vivo bioactivity of this bone cement. The absence of cement cracks indicates a sufficient mechanical stability to fix prostheses with this bioactive cement, but for a final assessment long-term tests are necessary.


Assuntos
Cimentos Ósseos/química , Metacrilatos/química , Osseointegração , Polimetil Metacrilato/química , Animais , Fêmur/anatomia & histologia , Fêmur/fisiologia , Fêmur/cirurgia , Teste de Materiais , Fosforilação , Próteses e Implantes , Coelhos , Estresse Mecânico , Tíbia/anatomia & histologia , Tíbia/fisiologia , Tíbia/cirurgia , Suporte de Carga
7.
Pain Physician ; 13(3): 263-71, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20495591

RESUMO

BACKGROUND: Radiofrequency (RF) and cryolesioning are established methods for the therapeutic interruption of sensory nerve supply to facet joints and other painful musculoskeletal structures. The varying clinical success rates of these treatments have - among other technical issues - been attributed to the small size of these lesions combined with the limited precision in placing them. Since there are 2 different physical methods for lesioning and a wide range of probes and lesion generators available, it is likely that the lesions generated by them may be of different size. OBJECTIVES: We sought to devise an experimental setup that would allow for the reproducible and comparable evaluation of the size of cryo and RF lesions as they are being used in interventional pain therapy. METHODS: A wide range of potential media was evaluated for this purpose. Based on technical specifications, as well as on preliminary testing, a specific agar agar gel with a gel point of between 32 degrees C and 35 degrees C and a melting point of between 80 degrees C and 85 degrees C was selected for these experiments. Two different testing containers were constructed from transparent acrylic: one with a volume of 1,500 mL and the other with a volume of 12 mL. Each of them allows for the introduction of a cryo or a RF probe and 2 bundles of thermoelements into the gel volume. A water bath was used to maintain the gels at 37 degrees C and bundled, ultrafine NiCr-Ni thermoelements type K were used for measuring the isotherms. A series of RF and cryolesions were performed within these experimental setups to evaluate their suitability for the comparative testing of cryo and RF probes and generators. RESULTS: Both testing setups generated reproducible results and proved to be suitable for measuring RF as well as cryolesions. Visual observation of the lesions was better with the small testing container and rewarming / recooling after performing a cryo / RF lesion was more rapid with the smaller gel volume. LIMITATIONS: Our setup allows for the comparative measurement of RF and cryolesions, but it cannot simulate the realities within living tissue. While convection as a confounding factor was excluded by use of a gel, capillary perfusion and the specific characteristics of different tissues cannot be simulated. CONCLUSIONS: The testing setup described in this manuscript can serve for the comparative and reproducible study of RF and cryolesions that are commonly used in interventional pain therapy.


Assuntos
Ablação por Cateter/normas , Criocirurgia/normas , Denervação/métodos , Teste de Materiais/instrumentação , Manejo da Dor , Cuidados Paliativos/métodos , Doenças da Coluna Vertebral/terapia , Coluna Vertebral/inervação , Desenho de Equipamento , Géis , Humanos , Teste de Materiais/normas , Reprodutibilidade dos Testes
8.
J Orthop Res ; 28(8): 1050-6, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20135673

RESUMO

The aim of this study was to determine if extracorporeal shock wave therapy (ESWT) in vivo affects the structural integrity of articular cartilage. A single bout of ESWT (1500 shock waves of 0.5 mJ/mm(2)) was applied to femoral heads of 18 adult Sprague-Dawley rats. Two sham-treated animals served as controls. Cartilage of each femoral head was harvested at 1, 4, or 10 weeks after ESWT (n = 6 per treatment group) and scored on safranin-O-stained sections. Expression of tenascin-C and chitinase 3-like protein 1 (Chi3L1) was analyzed by immunohistochemistry. Quantitative real-time polymerase chain reaction (PCR) was used to examine collagen (II)alpha(1) (COL2A1) expression and chondrocyte morphology was investigated by transmission electron microscopy no changes in Mankin scores were observed after ESWT. Positive immunostaining for tenascin-C and Chi3L1 was found up to 10 weeks after ESWT in experimental but not in control cartilage. COL2A1 mRNA was increased in samples 1 and 4 weeks after ESWT. Alterations found on the ultrastructural level showed expansion of the rough-surfaced endoplasmatic reticulum, detachment of the cell membrane and necrotic chondrocytes. Extracorporeal shock waves caused alterations of hyaline cartilage on a molecular and ultrastructural level that were distinctly different from control. Similar changes were described before in the very early phase of osteoarthritis (OA). High-energy ESWT might therefore cause degenerative changes in hyaline cartilage as they are found in initial OA.


Assuntos
Ondas de Choque de Alta Energia , Cartilagem Hialina/metabolismo , Animais , Proteína 1 Semelhante à Quitinase-3 , Colágeno Tipo II/biossíntese , Proteínas da Matriz Extracelular/biossíntese , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/ultraestrutura , Glicoproteínas/biossíntese , Masculino , Microscopia Eletrônica de Transmissão , Radiografia , Ratos , Ratos Sprague-Dawley , Tenascina/genética
9.
Brain Res ; 1207: 96-101, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18371941

RESUMO

Application of extracorporeal shockwaves to the musculoskeletal system can induce long-term analgesia in the treatment of chronic painful diseases such as calcifying tendonitis of the shoulder, tennis elbow and chronic plantar fasciitis. However, the molecular and cellular mechanisms underlying this phenomenon are largely unknown. Recently it was shown that application of extracorporeal shockwaves to the distal femur of rabbits can lead to reduced concentration of substance P in the shockwaves' focal zone. In the present study we investigated the impact of extracorporeal shockwaves on the production of substance P within dorsal root ganglia in vivo. High-energy shockwaves were applied to the ventral side of the right distal femur of rabbits. After six weeks, the dorsal root ganglia L5 to L7 were investigated with high-precision design-based stereology. The application of extracorporeal shockwaves caused a statistically significant decrease in the mean number of neurons immunoreactive for substance P within the dorsal root ganglion L5 of the treated side compared with the untreated side, without affecting the total number of neurons within this dorsal root ganglion. No effect was observed in the dorsal root ganglia L6 and L7, respectively. These data might further contribute to our understanding of the molecular and cellular mechanisms in the induction of long-term analgesia by extracorporeal shockwave application to the musculoskeletal system.


Assuntos
Eletrochoque/métodos , Fêmur/efeitos da radiação , Gânglios Espinais/citologia , Neurônios/efeitos da radiação , Substância P/metabolismo , Animais , Feminino , Região Lombossacral , Neurônios/metabolismo , Coelhos
10.
Knee Surg Sports Traumatol Arthrosc ; 16(5): 504-10, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18193198

RESUMO

Suture anchors are increasingly gaining importance in rotator cuff surgery. This means they will be gradually replacing transosseous sutures. The purpose of this study was to compare the stability of transosseous sutures with different suture anchors with regard to their pullout strength depending on bone density. By means of bone densitometry (CT scans), two groups of human humeral head specimens were determined: a healthy and a osteopenic bone group. Following anchor systems were being tested: SPIRALOK 5.0 mm (resorbable, DePuy Mitek), Super Revo 5 mm (titanium, Linvatec), UltraSorb (resorbable, Linvatec) and the double U-sutures with Orthocord USP 2 (partly resorbable, DePuy Mitek) and Ethibond Excel 2 (non-resorbable, Ethicon). The suture anchors/double U-sutures were inserted in the greater tuberosity 12 times. An electromechanical testing machine was used for cyclic loading with power increasing in stages. We recorded the ultimate failure loads, the system displacements and the modes of failure. The suture anchors tended to bring about higher ultimate failure loads than the transosseous double U-sutures. This difference was significant in the comparison of the Ethibond suture and the SPIRALOK 5.0 mm-both in healthy and osteopenic bone. Both the suture materials and the SPIRALOK 5.0 mm showed a significant difference in pullout strength on either healthy or osteopenic bone; the titanium anchor SuperRevo 5 mm and the tilting anchor UltraSorb did not show any significant difference in healthy or osteopenic bone. There was no significant difference concerning system displacement (healthy and osteopenic bone) between the five anchor systems tested. The pullout strength of transosseous sutures is neither on healthy nor on osteopenic bone higher than that of suture anchors. Therefore, even osteopenic bone does not constitute a valid reason for the surgeon to perform open surgery by means of transosseous sutures. The choice of sutures in osteopenic bone is of little consequence anyway since it is mostly the bone itself which is the limiting factor.


Assuntos
Teste de Materiais , Manguito Rotador/cirurgia , Âncoras de Sutura , Suturas , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Desenho de Equipamento , Feminino , Humanos , Úmero/fisiopatologia , Úmero/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Lesões do Manguito Rotador , Estresse Mecânico
11.
Reg Anesth Pain Med ; 32(1): 27-33, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17196489

RESUMO

BACKGROUND AND OBJECTIVES: At many institutions, it is not practically feasible to perform a series of controlled or placebo-controlled medial branch blocks on several facet joints in order to select patients for facet joint rhizotomy. As for uncontrolled blocks, there is no proof that medial branch blocks are superior to other types of blocks. This study was performed to compare medial branch blocks to simple pericapsular blocks for the selection of patients for lumbar facet joint cryodenervation. METHODS: Patient selection was based on history, imaging, and physical examination. Diagnostic blocks were either medial branch blocks or pericapsular blocks. Percutaneous medial branch cryodenervation was performed by use of a Lloyd Neurostat 2000. Outcome parameters were low back pain (visual analog scale [VAS]), limitation of activity (Macnab), and overall satisfaction. A total of 26 patients were recruited, 13 for each group. Follow-up was 6 months. RESULTS: Patients who had been selected by medial branch blocks had better pain relief than did patients who had been diagnosed by use of pericapsular blocks. At 6 weeks and at 3 months after treatment, these results reached statistical significance (VAS 2.2 v 4.2, P < .05). CONCLUSIONS: Our results suggest that uncontrolled medial branch blocks are superior to pericapsular blocks in selecting patients for facet joint cryodenervation, but both blocks work. If serial controlled blocks cannot be used, lumbar facet joint pain remains a diagnostic dilemma.


Assuntos
Criocirurgia , Denervação , Bloqueio Nervoso , Articulação Zigapofisária/cirurgia , Algoritmos , Feminino , Humanos , Dor Lombar/cirurgia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Estudos Prospectivos , Resultado do Tratamento , Articulação Zigapofisária/inervação
13.
BMJ ; 327(7406): 75, 2003 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-12855524

RESUMO

OBJECTIVE: To determine the effectiveness of extracorporeal shock wave therapy compared with placebo in the treatment of chronic plantar fasciitis. DESIGN: Randomised, blinded, multicentre trial with parallel group design. SETTING: Nine hospitals and one outpatient clinic in Germany. PARTICIPANTS: 272 patients with chronic plantar fasciitis recalcitrant to conservative therapy for at least six months: 135 patients were allocated extracorporeal shock wave therapy and 137 were allocated placebo. MAIN OUTCOME MEASURES: Primary end point was the success rate 12 weeks after intervention based on the Roles and Maudsley score. Secondary end points encompassed subjective pain ratings and walking ability up to a year after the last intervention. RESULTS: The primary end point could be assessed in 94% (n=256) of patients. The success rate 12 weeks after intervention was 34% (n=43) in the extracorporeal shock wave therapy group and 30% (n=39) in the placebo group (95% confidence interval - 8.0% to 15.1%). No difference was found in the secondary end points. Few side effects were reported. CONCLUSIONS: Extracorporeal shock wave therapy is ineffective in the treatment of chronic plantar fasciitis.


Assuntos
Fasciíte Plantar/terapia , Litotripsia/métodos , Algoritmos , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Litotripsia/efeitos adversos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS