Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Transfusion ; 62(3): 633-640, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35089597

RESUMO

BACKGROUND: To investigate the transmission of SARS-CoV-2 via blood, we conducted retrospective molecular screening in blood donated during the first pandemic peak in the two French regions with the highest community transmission. METHODS: Archived plasma samples randomly selected from donations collected between March 23 and 29, 2020, in Eastern and Northern regions of France were tested for SARS-CoV-2 RNA in minipools of 4 donations (MP4) using the Grifols ProcleixSARS-CoV-2 assay. Reactive MP4 and the four corresponding plasmas were further tested with alternative RT-PCRs and sequencing. Testing for SARS-CoV-2 antibodies and in vitro infectivity in cell culture were also performed. RESULTS: Among the 2818 MP4 (corresponding to 9672 donations) tested for viral RNA, 5 were weakly reactive. Among the 20 plasmas included in these five MP4, one presented low-level reactivity with RT-PCRs and Procleix SARS-CoV-2 and was confirmed on sequencing. The estimated prevalence was 1.03/10,000 (95% CI 0-3.1). The 20 plasmas were antibody nonreactive and none of them showed cytopathic effects in cell culture. When recalled, the index-donor declared having had symptoms compatible with SARS-CoV-2 infection a few days after donation. The two immunocompromised recipients transfused with red blood cells and an inactivated pooled platelet product did not develop COVID-19. CONCLUSION: Our results indicated a low prevalence of SARS-CoV-2 RNA in the plasma of asymptomatic blood donors during the pandemic peak and no evidence of infectivity in vivo and in vitro. The transfusion risk remains theoretical and does not justify the implementation of SARS-CoV-2 NAT for blood donations.


Assuntos
Doadores de Sangue , COVID-19 , COVID-19/epidemiologia , Humanos , RNA Viral , Estudos Retrospectivos , SARS-CoV-2
2.
Emerg Infect Dis ; 26(12): 2881-2886, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33219652

RESUMO

Hepatitis E has emerged as a major transfusion-transmitted infectious risk. Two recipients of plasma from 2 lots (A and B) of pooled solvent/detergent-treated plasma were found to be infected by hepatitis E virus (HEV) that was determined to have been transmitted by the solvent/detergent-treated plasma. HEV RNA viral loads were 433 IU in lot A and 55 IU in lot B. Retrospective studies found that 100% (13/13) of evaluable lot A recipients versus 18% (3/17) of evaluable lot B recipients had been infected by HEV (p<0.001), albeit not necessarily at time of transfusion. Among evaluable recipients, 86% with a transfused HEV RNA load >50,000 IU were infected, most likely by the HEV-containing solvent/detergent-treated plasma, versus only 7% with a transfused HEV RNA load <50,000 IU (p<0.001). Overall, solvent/detergent-treated plasma might harbor HEV. Such an occurrence might result in a dose-dependent risk for transfusion-transmitted hepatitis E.


Assuntos
Doadores de Sangue , Vírus da Hepatite E , Hepatite E , Plasma , Detergentes , Hepatite E/epidemiologia , Hepatite E/transmissão , Vírus da Hepatite E/genética , Humanos , RNA Viral , Estudos Retrospectivos , Solventes
3.
Transplantation ; 102(8): 1351-1357, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29561324

RESUMO

BACKGROUND: After observing a case of plasma exchange-mediated hepatitis E virus (HEV) infection in a kidney transplant recipient, we investigated the relationship between plasma exchange and HEV infection after kidney transplantation. METHODS: A cohort of 263 patients who underwent kidney transplantation from January 1, 2011, through December 31, 2012, was screened for HEV markers, including anti-HEV IgG and IgM antibodies and HEV ribonucleic acid (RNA), on 3 consecutive blood samples: 1 before, 1 with a mean (standard deviation) of 9.5 (9) months, and 1 with a mean (standard deviation) of 18.2 (6.6) months after transplantation, respectively. Transfusional investigation was performed in patients with detectable HEV RNA. We explored the relationships between plasma exchange, posttransplantation transaminase elevation and HEV markers acquisition. RESULTS: Overall, 24 (9.1%) patients had acquired HEV markers on the first posttransplantation sample, including 2 patients with detectable HEV RNA, and 7 (2.3%) patients had long-term persistent HEV markers on the second posttransplantation sample, including 3 patients with detectable HEV RNA without detectable anti-HEV antibodies. Plasma exchange was an independent risk factor for the acquisition of posttransplantation and long-term persistent HEV markers. Pathogen-reduced plasma-borne transmission of HEV was demonstrated. Plasma exchange and long-term persistent HEV markers were risk factors of posttransplantation transaminase elevation. CONCLUSIONS: Plasma exchange, including with pathogen-reduced plasma, is a risk factor for posttransplantation HEV infection and transaminase elevation. Screening for HEV RNA should be carried out in kidney transplant recipients treated with plasma exchange.


Assuntos
Vírus da Hepatite E , Hepatite E/transmissão , Falência Renal Crônica/cirurgia , Transplante de Rim/efeitos adversos , Troca Plasmática , Adulto , Idoso , Transfusão de Sangue , Estudos Transversais , Feminino , Anticorpos Anti-Hepatite/sangue , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Terapia de Imunossupressão , Falência Renal Crônica/virologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Filogenia , RNA Viral/análise , Estudos Retrospectivos , Fatores de Risco , Análise de Sequência de DNA , Transaminases/metabolismo , Transplantados
4.
Transfusion ; 56(6): 1311-1313, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27040329

RESUMO

BACKGROUND: Transfusion-transmitted bacterial infection (TTBI) is still one of the most feared complications of blood transfusion. CASE REPORT: We report a fatal case involving an 8-year-old child with congenital dyskeratosis complicated by severe aplastic anemia who was regularly transfused with platelet (PLT) concentrates for 5 years. The patient received an apheresis PLT concentrate (APC) on Day 0 due to thrombocytopenia complicated by mucocutaneous hemorrhage. Thirty minutes after the start of the transfusion, bradycardia and dyspnea appeared, quickly followed by chills, nausea, vomiting, headache, and hyperthermia. TTBI was suspected and the patient was immediately treated with intravascular antibiotherapy. On Day 3, the patient developed severe acute respiratory distress syndrome leading to death on Day 7. Patient blood cultures and APC cultures were both positive for Citrobacter koseri. RESULTS: The donor was a 19-year-old woman. She had previously given blood. No infectious symptom was reported during the medical interviews before and after the donation and no postdonation information was received. On the day of the donation (Day -2), her white blood cell count was 5.83 × 109 /L. She came back on Day 8 to undergo additional tests. The cultures from blood, stool, urine, the skin of the inside of the elbow at the point of needle insertion, and ear samples were all negative for C. koseri. However, a nasal sample was positive for C. koseri. CONCLUSION: The isolates from the donor's blood cultures, the APC bag, the attached tube, and the donor's nasal sample all gave identical profiles; they were thus identified as the same strain and the TTBI was confirmed.

7.
Transfus Med Hemother ; 35(2): 89-91, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-21512633

RESUMO

SUMMARY: The French Hemovigilance Network has been established in 1994 and records all adverse events associated with the transfusion of a labile blood products (LBP) regardless of their severity. From 1994 to 2006 35,423,172 LBP were issued, 85,812 adverse transfusion reactions notified, and 139 cases of transfusion related acute lung injury (TRALI) observed. The LBP most at risk is fresh frozen plasma (FFP), followed by platelets concentrates (PC) and packed red cells (PRC). However, because the use of FFP is not frequent in France, it only accounts for about 10% of TRALI, whereas PRC and PC are involved in the remaining cases. In no case, pooled FFP treated with solvent-detergent were involved. Patients' profiles are peculiar with a high disease burden. Therefore, targeting a prevention policy only on FFP would result in a marginal reduction of TRALI in France.

8.
Transfus Apher Sci ; 31(2): 145-53, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15501418

RESUMO

In 1993 by law, in France, haemovigilance became a national system of surveillance and alert, from blood collection to the follow-up of the recipients, gathering and analysing all adverse events of blood transfusion in order to prevent their recurrences. In 2003, 2911 incidents with strong imputability have been specially analysed, among them seven confirmed cases of bacterial contamination, 137 incorrect blood components transfused with 12 cases of ABO incompatibility, 15 adverse reactions diagnosed as TRALI and 12 deaths. The analysis of information provided by haemovigilance has led to the implementation of new guidelines.


Assuntos
Bancos de Sangue/normas , Coleta de Dados , Erros Médicos/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Gestão de Riscos/organização & administração , Reação Transfusional , Bancos de Sangue/legislação & jurisprudência , Bancos de Sangue/organização & administração , Doadores de Sangue/legislação & jurisprudência , Transfusão de Sangue/mortalidade , Transfusão de Sangue/normas , França , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...