RESUMO
Inducing immunogenic cell death (ICD) during cancer therapy is a major challenge that might significantly improve patient survival. The purpose of this study was to develop a theranostic nanocarrier, capable both of conveying a cytotoxic thermal dose when mediating photothermal therapy (PTT) after its intravenous delivery, and of consequently inducing ICD, improving survival. The nanocarrier consists of red blood cell membranes (RBCm) embedding the near-infrared dye IR-780 (IR) and camouflaging Mn-ferrite nanoparticles (RBCm-IR-Mn). The RBCm-IR-Mn nanocarriers were characterized by size, morphology, surface charge, magnetic, photophysical, and photothermal properties. Their photothermal conversion efficiency was found to be size- and concentration-dependent. Late apoptosis was observed as the cell death mechanism for PTT. Calreticulin and HMGB1 protein levels increased for in vitro PTT with temperature around 55 °C (ablative regime) but not for 44 °C (hyperthermia), suggesting ICD elicitation under ablation. RBCm-IR-Mn were then intravenously administered in sarcoma S180-bearing Swiss mice, and in vivo ablative PTT was performed five days later. Tumor volumes were monitored for the subsequent 120 days. RBCm-IR-Mn-mediated PTT promoted tumor regression in 11/12 animals, with an overall survival rate of 85% (11/13). Our results demonstrate that the RBCm-IR-Mn nanocarriers are great candidates for PTT-induced cancer immunotherapy.
RESUMO
Biomimetic nanoparticles hold great promise for photonic-mediated nanomedicine due to the association of the biological functionality of the membrane with the physical/chemical goals of organic/inorganic structures, but studies involving fluorescent biomimetic vesicles are still scarce. The purpose of this article is to determine how photothermal therapy (PTT) with theranostic IR-780-based nanoparticles depends on the dye content, cholesterol content, lipid bilayer phase and cell membrane type. The photophysical responses of synthetic liposomes, cell membrane vesicles and hybrid nanoparticles are compared. The samples were characterized by nanoparticle tracking analysis, photoluminescence, electron spin resonance, and photothermal- and heat-mediated drug release experiments, among other techniques. The photothermal conversion efficiency (PCE) was determined using Roper's method. All samples excited at 804 nm showed three fluorescence bands, two of them independent of the IR-780 content. Samples with a fluorescence band at around 850 nm showed photobleaching (PBL). Quenching was higher in cell membrane vesicles, while cholesterol inhibited quenching in synthetic liposomes with low dye content. PTT depended on the cell membrane and was more efficient for melanoma than erythrocyte vesicles. Synthetic liposomes containing cholesterol and a high amount of IR-780 presented superior performance in PTT experiments, with a 2.4-fold PCE increase in comparison with free IR-780, no PBL and the ability to heat-trigger doxorubicin release.
RESUMO
The development of rational therapies against complex diseases, such as cancer, has increased in the past few years due to the advances of 'omics' technologies. Concomitantly, several efforts have been made to design sophisticated drug delivery systems in order to increase specificity and drug accumulation in tumor sites. The complexity of these drug delivery systems highlights the need for suitable analytical methods to determine encapsulation/conjugation efficiency of drugs and molecules responsible for the targeted delivery. Therefore, this study focuses on the development and validation of a RP-HPLC-DAD methodology for concurrent quantification of paclitaxel (PTX) and cetuximab (CTX) in immunoliposomes. Chromatographic separation was achieved using a wide pore C8 column, and a gradient mobile phase consisting of 0.1% trifluoroacetic acid (TFA) in Milli-Q water/acetonitrile/isopropanol with a flow rate of 1 mL min-1. Drug peaks were fully separated and detected at 280 nm using UV detector. The method was validated according to ICH and FDA guidelines in terms of specificity and forced degradation studies, system suitability, linearity, limit of detection, limit of quantification, repeatability, intermediate precision, accuracy, robustness, and short-term stability. The developed method was linear over the concentration range of 37.5-150 µg mL-1 of PTX and 75-300 µg mL-1 of CTX. All parameters evaluated satisfied the acceptance criteria, according to both FDA and ICH guidelines. The applicability of the analytical method was assessed following the development of PTX-loaded immunoliposomes conjugated with CTX. Thus, the present study shows a novel, simple, stability-indicating and suitable method to quantify simultaneously PTX and CTX in immunoliposomes.