Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(13): 132501, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38613302

RESUMO

Neutron dark decays have been suggested as a solution to the discrepancy between bottle and beam experiments, providing a dark matter candidate that can be searched for in halo nuclei. The free neutron in the final state following the decay of ^{6}He into ^{4}He+n+χ provides an exceptionally clean detection signature when combined with a high efficiency neutron detector. Using a high-intensity ^{6}He^{+} beam at Grand Accélérateur National d'Ions Lourds, a search for a coincident neutron signal resulted in an upper limit on a dark decay branching ratio of Br_{χ}≤4.0×10^{-10} (95% C.L.). Using the dark neutron decay model proposed originally by Fornal and Grinstein, we translate this into an upper bound on a dark neutron branching ratio of O(10^{-5}), improving over global constraints by one to several orders of magnitude depending on m_{χ}.

2.
Phys Rev Lett ; 131(8): 082502, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37683153

RESUMO

We present an apparatus for detection of cyclotron radiation yielding a frequency-based ß^{±} kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear ß decays. The cyclotron frequency of the radiating ß particles in a magnetic field is used to determine the ß energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of ß^{-}'s from ^{6}He and ß^{+}'s from ^{19}Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for ß spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic ß's in a waveguide. This work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision ß-decay measurements.

3.
Phys Rev Lett ; 127(16): 162501, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34723594

RESUMO

We report an improved measurement of the free neutron lifetime τ_{n} using the UCNτ apparatus at the Los Alamos Neutron Science Center. We count a total of approximately 38×10^{6} surviving ultracold neutrons (UCNs) after storing in UCNτ's magnetogravitational trap over two data acquisition campaigns in 2017 and 2018. We extract τ_{n} from three blinded, independent analyses by both pairing long and short storage time runs to find a set of replicate τ_{n} measurements and by performing a global likelihood fit to all data while self-consistently incorporating the ß-decay lifetime. Both techniques achieve consistent results and find a value τ_{n}=877.75±0.28_{stat}+0.22/-0.16_{syst} s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.

4.
Phys Rev Lett ; 124(8): 081803, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32167372

RESUMO

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons. Our measurement stands in the long history of EDM experiments probing physics violating time-reversal invariance. The salient features of this experiment were the use of a ^{199}Hg comagnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic-field changes. The statistical analysis was performed on blinded datasets by two separate groups, while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is d_{n}=(0.0±1.1_{stat}±0.2_{sys})×10^{-26} e.cm.

5.
Opt Express ; 23(17): 22108-15, 2015 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-26368184

RESUMO

We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 µT magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 µrad for integration times from 10 s up to 2000 s.

6.
Am J Dis Child ; 147(9): 971-4, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8362815

RESUMO

OBJECTIVE: To provide a descriptive summary of characteristics, including demographics, symptoms, risk factors, and outcome of acquired subglottic cysts identified in the neonatal period. DESIGN: Patient series. SETTING: A tertiary neonatal care unit and referral neonatal follow-up clinic. PARTICIPANTS: One hundred seventy-four preterm infants undergoing flexible bronchoscopy, 21 (12%) referred for airway evaluation because of symptoms and 153 (88%) examined consecutively following 7 days or more of endotracheal intubation. INTERVENTION: None. MEASUREMENTS/RESULTS: Subglottic cysts were identified in 11 (7.2%) of 153 preterm infants examined prospectively at discharge from the neonatal intensive care unit after prolonged intubation and two (10%) of 21 infants referred for airway evaluation. Infants with subglottic cysts were extremely preterm (mean +/- SEM gestation, 26.7 +/- 0.5 weeks) and very low birth weight (894.6 +/- 64.6 g). The mean duration of intubation was 28.5 +/- 5.0 days. Most infants, particularly those with large cysts, were symptomatic with stridor, hoarseness, or obstructive apnea. In two cases, airway symptoms began after discharge from the neonatal intensive care unit. Ten (91%) of the 11 patients were discharged receiving home oxygen. Generally, multiple cysts were present in the subglottic space, most prominently located in the posterior aspect of the trachea. Three of five patients with large cysts received a tracheostomy. Two additional patients had surgical marsupialization of the cysts, and six others experienced resolution without treatment. One patient with large cysts died of viral pneumonia 10 months after surgical intervention. An additional patient with large cysts died before surgical intervention secondary to chronic lung disease and cor pulmonale. All surviving infants had resolution of signs of airway obstruction and 10 of the 11 did not require supplemental oxygen or have symptoms of chronic pulmonary disease at age 1 year. CONCLUSION: Intubation-acquired subglottic mucous cysts in the neonate may occur more commonly than was previously recognized. Symptoms of this lesion may mimic features of chronic lung disease. Early identification of the cysts with flexible bronchoscopy is important since airway compromise may progress and surgical intervention may be lifesaving.


Assuntos
Cistos , Glote , Recém-Nascido de Baixo Peso , Doenças do Prematuro , Broncoscopia , Cistos/diagnóstico , Cistos/etiologia , Cistos/terapia , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/diagnóstico , Doenças do Prematuro/etiologia , Doenças do Prematuro/terapia , Intubação Intratraqueal/efeitos adversos , Doenças da Laringe/diagnóstico , Doenças da Laringe/etiologia , Doenças da Laringe/terapia , Pneumopatias Obstrutivas/diagnóstico , Estudos Prospectivos , Resultado do Tratamento
7.
J Pediatr ; 121(2): 275-9, 1992 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1640297

RESUMO

PURPOSE: To assess the frequency and pathogenesis of hyperkalemia in the very low birth weight infant. METHODS: Infants who weighed less than 1000 gm at birth were prospectively entered into the study within 12 hours of birth. Potential risk factors for hyperkalemia were assessed. Body weight, fluid and electrolyte balance, serum levels of sodium and potassium, creatinine clearance, fractional sodium excretion, and urine sodium/potassium ratio were measured every 8 hours for 72 hours. Measurements of plasma renin, serum aldosterone, and plasma atrial natriuretic factor were made at study entry and repeated when hyperkalemia (serum potassium greater than 6.5 mmol/L) occurred or at 72 hours. Infants in whom hyperkalemia developed were compared with those in whom it did not. RESULTS: Thirty-one infants completed the study; hyperkalemia developed in 16 (51.6%). The only difference in the occurrence of perinatal complications was the more frequent occurrence of pH less than 7.20 in infants with subsequent development of hyperkalemia. Creatinine clearance, urine output, and potassium excretion were significantly lower in the hyperkalemia group during the first 24 hours. Serum potassium concentration at 24 hours was inversely related to urine output in the prior 24 hours. Fractional sodium excretion, urine sodium/potassium ratio, and levels of renin, aldosterone, and atrial natriuretic factor did not differ between groups. CONCLUSIONS: Hyperkalemia is a frequent complication in very low birth weight infants. Infants with low urinary flow rates during the first few hours after birth are at greatest risk for the development of hyperkalemia.


Assuntos
Hiperpotassemia/etiologia , Recém-Nascido de Baixo Peso/metabolismo , Potássio/sangue , Aldosterona/sangue , Humanos , Hiperpotassemia/epidemiologia , Hiperpotassemia/metabolismo , Incidência , Recém-Nascido , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS