Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 128(7): 075001, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35244411

RESUMO

A new method for measuring the time-dependent drive flux at the hohlraum center is proposed as a better alternative to conventional wall-based techniques. The drive flux here is obtained by simultaneous measurement of the reemitted flux and shock velocity from a three-layered "cakelike" sample. With these two independent observables, the influence induced by the uncertainty of the material parameters of the sample can be effectively decreased. The influence from the closure of the laser entrance hole, which was the main challenge in conventional wall-based techniques, was avoided through localized reemitted flux measurement, facilitating drive flux measurement throughout the entire time history. These studies pave a new way for probing the time-dependent drive flux, for both cylindrical hohlraums and novel hohlraums with six laser entrance holes.

2.
Phys Rev Lett ; 127(24): 245001, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34951808

RESUMO

In inertial confinement approaches to fusion, the asymmetry of target implosion is a major obstacle to achieving high gain in the laboratory. A recently proposed octahedral spherical hohlraum makes it possible to naturally create spherical target irradiation without supplementary symmetry control. Before any decision is made to pursue an ignition-scale laser system based on the octahedral hohlraum, one needs to test the concept with the existing facilities. Here, we report a proof-of-concept experiment for the novel octahedral hohlraum geometry on the cylindrically configured SGIII laser facility without a symmetry control. All polar and equatorial self-emission images of the compressed target show a near round shape of convergence ratio 15 under both square and shaped laser pulses. The observed implosion performances agree well with the ideal spherical implosion simulation. It also shows limitations with using the existing facilities and adds further weight to the need to move to a spherical port geometry for future ignition laser facilities.

3.
Phys Rev Lett ; 111(15): 155003, 2013 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-24160607

RESUMO

The first observation of the K-shell photoabsorption edge of strongly coupled matter with an ion-ion coupling parameter of about 65 generated by intense x-ray radiation-driven shocks is reported. The soft x-ray radiation generated by laser interaction with a "dog bone" high-Z hohlraum is used to ablate two thick CH layers, which cover a KCl sample, to create symmetrical inward shocks. While the two shocks impact at the central KCl sample, a highly compressed KCl is obtained with a density of 3-5 times solid density and a temperature of about 2-4 eV. The photoabsorption spectra of chlorine near the K-shell edge are measured with a crystal spectrometer using a short x-ray backlighter. The redshift of the K edge up to 11.7 eV and broadening of 15.2 eV are obtained for the maximum compression. A comparison of the measured redshifts and broadenings with dense plasma calculations are made, and it indicates potential improvements in the theoretical description.

4.
Rev Sci Instrum ; 81(5): 056108, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20515185

RESUMO

X-ray streak cameras are extensively used to study transient x-ray processes in experiments carried out on various laser facilities at the Research Center of Laser Fusion. Precise calibration and clear description of the sweep speed of the x-ray streak camera are vital for obtaining precise temporal information to understand the fast physics phenomena. An x-ray streak camera named wide-slit x-ray streak camera has been calibrated using a small-scale laser facility with pulse duration of 8 ps. Sweep speeds on most part of the output screen (charge coupled device) are obtained. These calibration results can be used to correct the nonlinearity of sweep speed in measurement of temporal processes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...