1.
J Environ Sci Health B ; 59(3): 81-87, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38179701

RESUMO

Ethylene oxide (EtO), although banned for use, is still being detected in foodstuffs that have been fumigated to eradicate pests during storage and transport. Residual levels over the European Union's (EU) maximum residue limit (MRL) pose severe health concerns. Recent detection of EtO and its by-product 2-chloroethanol (2-CE) at alarming levels have led to product recalls throughout the EU. Here, a simple, automated headspace (HS)-trap method for the simultaneous determination of EtO and its derivative 2-CE by gas chromatography-mass spectrometry (GC-MS) at the required MRL of ≤ 0.05 mg/kg has been implemented. Syringe-based HS combined with backflushed trapping technology provided enrichment of multiple extractions from the same sample vial (known as multi-step enrichment or MSE®) to increase sensitivity for EtO and 2-CE analysis by GC-MS using single-ion-monitoring (SIM) mode. Method detection limits (MDLs) of 0.00059 mg/kg and 0.00219 mg/kg for EtO and 2-CE, respectively, were obtained without the need for manual handling, solvent extraction or derivatization methods. Recoveries were shown to average (n = 5) at 98% and 107% for EtO and 2-CE, respectively, and the reproducibility was <10% for both compounds.


Assuntos
Óxido de Etileno , Praguicidas , Cromatografia Gasosa-Espectrometria de Massas/métodos , Reprodutibilidade dos Testes , Etilenocloroidrina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA